Home

Hunter 28784 Installation Guide

image

Contents

1. Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 3 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of three ways depending on ceiling height and your preference Low Profile Standard or Angled mounting The steps in this manual include instructions for all three Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance Support Brace Low Profile ad Mounting Style Outlet Box Low Profile Mounting fits close to the ceiling recommended for ceilings less than 8 feet high 5 45039 01 12 17 10 Hunter Fan Company A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied l Getting Ready To install a ceiling fan be sure
2. 4 4 Connect the white wire grounded from the ceiling to the white wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring e The black wire ungrounded from the ceiling to the black wire ungrounded from the fan e The black white wire ungrounded from the fan to the wire qc ss ungrounded for the wall switch Single Switch Wiring r ve e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan E nem Single Switch Wiring A CAUTION Be sure no bare wire or wire strands are visible after making connections 4 6 Turn the splices upward and push them carefully back through the ceiling plate into the outlet box 4 7 Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box p O ll 9 45039 01 12 17 10 Hunter Fan Company 5 Installing the Canopy and Canopy Trim Ring A WARNING Failure to complete the following steps could cause the fan to fall Note It is recommended you use a magnetic tip screwdriver for the following steps 5 1 Rotate the hanger ball so the tab in the canopy is secure in the hanger ball groove Note Your fan may have multiple tabs and grooves that must be aligned 5 2 Swing the
3. P IS Owner s Guide and Installation Manual For reference also attach your receipt or a copy of your receipt to the manual Warrenty Assistonre Type 2 Mode SINCE 1886 Form 45039 01 20101217 2010 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the Preparing the Fan Site support structure of the building according to these instructions 1 e Getting Ready and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock 4 Wiring the Fan the circuit breakers in the off position securely fasten a prominent
4. Hanging the Fan Note To hang the fan you must tilt the canopy to an almost vertical position so that the canopy slots sit on the ceiling plate hooks 3 7 Raise the fan and align the slots in the canopy with the hooks on the ceiling plate 3 8 Place the slots over the hooks to hang the fan 8 Steps 3 2 3 3 Downrod Canopy gt g E i Adapter mee Cover gt Grommet P N Adapter Cover Canopy Trim Ring ee gt uu Low Profile Washer Steps 3 5 3 6 8 32 x 3 4 Screw 45039 01 12 17 10 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 Before attempting installation make sure the power is still off 4 2 To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided 4 3 Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the green ground wire grounding from the fan EA Wire Connector Dual Switch Wiring
5. 45039 01 12 17 10 Hunter Fan Company Ceiling Height Preparing the Fan Site continued Step 2 Cut the Ceiling Hole 2 1 Locate the site for the ceiling hole directly below the joist or support brace that will hold the outlet box and fan 2 2 Cut a 4 diameter hole through the drywall or plaster of the ceiling You will use the hole to install the support brace and outlet box Step 3 Install a Support Brace If Necessary Determine if there is a ceiling joist directly above the ceiling hole If the joist is there determine if it is positioned to allow you to recess the outlet box a minimum of 1 16 into the ceiling If NOT install a support brace as follows 3 1 Attach a 2 x 4 support brace between two joists Position it to allow you to recess the bottom of the outlet box a minimum of 1 16 into the ceiling 3 2 Check the support brace to ensure it will support the full weight of the fan and light kit Step 4 Install the Outlet Box 4 1 Obtain a UL approved octagonal 4 x 1 1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor diameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to
6. 5 Installing the Canopy and Canopy warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls Table Of Contents 2 Installing the Ceiling Plate 3 e Assembling and Hanging the Fan 8 Trim Ring 6 Assembling the Blades 7 Completing Your Installation With or Without a Bowl Light Fixture 8 Operating and Cleaning Your Ceiling 2010 Hunter Fan Company 2 45039 01 12 17 10 Hunter Fan Company Preparing the Fan Site Step 1 Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings Choose a fan site where e No object can come in contact with the rotating fan blades during normal operation e The fan blades are at least 7 feet above the floor and the ceiling is at least 8 feet high The fan blades have no obstructions to airflow such as walls or posts within 30 inches of the fan blade
7. fan up to align the canopy screw holes with the mounting holes on the ceiling plate A WARNING The slots in the canopy must remain engaged while swinging the canopy for alignment 5 3 Holding the canopy up with the screw holes aligned partially install two canopy screws into the holes opposite the ceiling plate tabs 5 4 Partially install a canopy screw into the hole between the two ceiling plate tabs When all the holes are properly aligned securely tighten all three canopy screws 5 5 Verify that the tabs in the canopy are still in the grooves of the hanger ball 5 6 Align the tabs on the trim ring opposite the grooves in the hanger ball Using both hands push the canopy trim ring up to the top of the canopy The canopy trim ring will snap and lock into place Note Should you need to remove the trim ring press firmly on opposite sides of the trim ring directly above the groove in the hanger ball The tabs will flex out releasing the canopy trim ring Step 5 1 Step 5 2 Step 5 3 Canopy gt Canopy Trim Canopy Screw 10 45039 01 12 17 10 Hunter Fan Company 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 6 2 6 4 Your fan may include blade grommets If your fan has grommets insert them by hand into the holes on the blades Attach each blade to a blade iron
8. tips e The fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan 30 From Wall or Nearest Obstruction 7 Minimum Blades to Floor 8 Minimum Checklist for Existing Fan Site If you want to use an existing fan site complete the following checklist to Fan Support determine if the site is acceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System e Fan attaches directly to building structure e Fan support system will hold full weight of the fan and light kit Ceiling Hole The outlet box clearance hole is directly below the joist or support brace Outlet Box e The outlet box is an UL approved octagonal 4 x 1 1 2 outlet box or as specified by the support brace manufacturer The outlet box is secured to the joist or support brace by wood screws and washers through the inner holes of outlet box The outer holes of the outlet box are aligned with joist or support brace e The bottom of the outlet box is recessed a minimum of 1 16 into ceiling Wiring e The electrical cable is secured to outlet box by an approved connector e Six inches of lead wires extend from outlet box Suitable Existing Fan Site Fan Support Outlet Box If your existing fan site is suitable skip ahead to Section 2 Installing the Ceiling Plate 3
9. you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 6 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 45039 01 12 17 10 Hunter Fan Company 2 Installing the Ceiling Plate A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a p
10. 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws Steps 7 1 7 3 Housing 7 4 Turn the housing counterclockwise until the housing assembly Assembly Upper Screw Switch screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws firmly Housing A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling 7 5 If you want to install the light fixture proceed with step 7 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 7 14 Once you have uninstalled the light fixture continue with step 7 6 12 45039 01 12 17 10 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued 7 6 To attach the lower switch housing connect the upper plug Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switc
11. h housing to the upper switch housing with three housing assembly screws connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Connector Steps 7 6 7 7 Lower Switch Housing Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts its light output Plug TT Exceeding the wattage limit marked on the MAX wattage a sticker affixed to the light socket s may result in fire hazard or improper operation Housing Assembly Screw 13 45039 01 12 17 10 Hunter Fan Company lt ___ Plug 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Installing the Glass Bowl 7 8 First install B10 candelabra bulbs 60 Watt Maximum into the sockets 7 9 Thread the light and fan pull chains through the hole in the center of the glass bowl Then thread the light pull chain through the hole in the center of the cover plate 7 10 Thread the fan pull chain through the grommet hole in the side of the cover plate 7 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 7 12 Thread the light
12. ing and Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Unbundle the wires from the fan and remove the paper caution tag Do not discard the tag until your installation is complete For Standard or Angled mounting 3 2 To assemble fan to hang down from a flat or angled ceiling insert the downrod through the canopy adapter cover grommet adapter cover and canopy trim ring The adapter cover and adapter cover grommet may already be attached to make one piece Feed the wires from the fan through the downrod 3 3 Loosen the square head setscrew on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the setscrew with a wrench or pliers Skip to Step 4 7 A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer The adapter cover and adapter cover grommet are not used for low profile mounting 3 4 Remove the set screw from the adapter 3 5 Place the low profile washer into the canopy 3 6 Align the holes in the washer with the holes in the adapter Assemble securely with three low profile screws
13. ing cap and plug button to the lower switch housing Once you have uninstalled the light fixture continue with step 7 6 Male Dummy Terminal Cap Female Dummy Terminal Plug Button 15 Y j 4 Lower Switch TT Steps 7 16 7 18 Threaded Rod TE Step 7 20 45039 01 12 17 10 Hunter Fan Company 8 1 8 2 8 3 8 5 8 6 8 Operating and Cleaning Your Ceiling Fan Turn on electrical power to the fan The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector The light pull chain controls power to the light The pull chain has two settings On and Off Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dir
14. pull chain through the finial and screw the finial onto the threaded rod end until tight 7 13 Attach the extra pull chains included to the light and fan pull chains using the breakaway connector You may find the ie Light Bulbs breakaway connector on the TR S B10 gt end of the extra chain _ Ss oe l ase att Maximum R _ _ Metal Rod r a Metal Disk Glass Bowl Breakaway Connector a Cover Plate pone a Finial 14 45039 01 12 17 10 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 7 14 To uninstall the light fixture first disconnect the plug connectors 7 15 between the black wire and the red wire Disconnect the plug connectors between the two white wires Uninstall the connector and washer from the end of the light fixture inside the lower switch housing Unscrew the threaded rod of the light fixture from the lower switch housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the hole Install the dummy terminals included in the sack parts on the two disconnected wires in the lower switch housing Install the switch hous
15. rominent warning device such as a tag to the service panel 2 1 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 in diameter For Angled Ceilings Be sure to orient the ceiling plate so that the two tabs are pointing toward the ceiling peak 2 2 Your fan comes with four preinstalled noise isolators Check to make sure all four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the hole in the center of the ceiling plate 2 5 Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure For proper alignment use slotted holes directly across from each other Note The isolators should be flush against the ceiling 2 6 Pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Flat Washer 3 Wood Screw a 7 45039 01 12 17 10 Hunter Fan Company Toward Ceiling Peak For Angled Ceilings Be sure to orient the ceiling plate so that the two tabs are pointing toward the ceiling peak Se hee Ceiling Plate E P Steps 2 3 2 6 3 Assembl
16. t and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish The blades on this fan have been treated with Hunter s Dust Armor protection making the blades less likely to attract dust and dirt Use a dry or slightly damp lint free cloth to clean the blades Do not use a furniture polish or any other cleaners that leave any residue as they will damage the protective To Change Airflow Direction Dust Armor on the Turn the fan off and let it come to a complete blades stop Slide the reversing switch on the fan to the opposite position Restart fan 16 45039 01 12 17 10 Hunter Fan Company In warm weather use downward air flow pattern In cold weather use upward air flow pattern 9 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive
17. the support brace or joist with two 8 x 1 1 2 wood screws and washers Th e bottom of the outlet box must be recessed a minimum of 1 16 into the ceiling Step 5 Prepare the Wiring 5 1 Make sure the circuit breakers to the fan supply line leads and associated wall switch location are turned off If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 5 2 Thread the fan supply line through the outlet box so that the fan supply line extends at least 6 beyond the box 5 3 Attach the fan supply line to the outlet box with an approved connector available at any hardware store or electrical supply house 5 4 Make certain the wiring meets all national and local standards and ANSI NFPA 70 You have now successfully prepared your ceiling fan site For instructions to install your ceiling fan go to your fan manual and continue with Section 2 Installing the Ceiling Plate 4 45039 01 12 17 10 Hunter Fan Company A CAUTION All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included
18. using three blade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened This is normal Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Note The blades on this fan have been treated with Hunter s Dust Armor protection making the blades less likely to attract dust and dirt Use a dry or slightly damp lint free cloth to clean the blades Do not use a furniture polish or any other cleaners that leave any residue as they will damage the protective Dust Armor on the blades Use with grommet Blade Assembly Screws Use without grommet lI 45039 01 12 17 10 Hunter Fan Company Step 6 1 Detail Steps 6 1 6 2 7 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the included light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model
19. wobbling 1 Make sure the blades are securely attached to the blade irons according to the blade assembly instructions provided 2 After thoroughly verifying the blades are securely attached to the blade irons follow the instructions in the enclosed balancing kit to balance the fan 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights shut off suddenly but fan is still operating 1 Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the light socket 2 Turn the power to the fan off at the wall switch Wait 5 minutes then resume power to the fan Problem CFL bulbs flicker when controlled by a dimming remote or wall control 1 CFL light bulbs are not usually made for dimming Replace the CFL bulbs with dimmable light bulbs or install the fan in a location without a dimming control If you need parts or service assistance please call 888 830 1326 In Canada call 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 17 45039 01 12 17 10 Hunter Fan Company

Download Pdf Manuals

image

Related Search

Related Contents

CR3000 Copy Reader - Maine`s Public Universities  VLSI - nexp  Corrections of "RX63T Group User`s Manual: HardwareRev.2.10"  USER'S GUIDE  Peavey Electronics Spider-man Rockmaster  manual de instruções do multímetro analógico ma-60  Samsung Микроволновая печь 23 литров 850 Вт CE283DNR Инструкция по использованию    Dashboard User Manual - Oracle Documentation  EUROLITE Neon-Tube Complete Set User Manual  

Copyright © All rights reserved.
Failed to retrieve file