Home
Casablanca 84U73D Installation Guide
Contents
1. speed switch to HI set fastest fan speed with pull chain SAVING MONEY WITH YOUR CEILING FAN IN SUMMER the movement of air creates a cooling wind chill effect A room can actually feel several degrees cooler without set ting the thermostat lower IN WINTER hot air rises to the ceiling while cool air settles to the floor Trapped against the ceiling the warm air is wasted If you turn up the thermostat energy costs will rise RUNNING IN REVERSE your Casablanca fan can recirculate warm air near the ceiling down into the living area providing even heating and comfort with a pleas ant effect on heating bills 3 SPEED TROUBLESHOOTING BEFORE REQUESTING SERVICE Please follow this troubleshooting guide before contacting your dealer for assistance Caring for Finishes For cleaning a soft brush or lint free cloth Never Lubricate this Fan should be used to prevent scratching the finish A vacuum cleaner The precision motor at the heart of your Casablanca fan features brush nozzle can remove heavier dust Surface smudges or an accu sealed bearings that are lubricated for life Do not attempt to oil mulation of dirt and dust can easily be removed by using a mild the motor detergent and slightly dampened soft cloth An antistatic agent may be used but never use abrasive cleaning agents These will Changing Light Bulbs damage the finish Painted and high gloss blades may be
2. BLADE SCREW Pa 3 PER BLADE FLAT WASHER i e 3 PER BLADE Step 12 Attach the blades to the blade holders with the three blade screws and flat washers provided for each blade Hand tighten securely T Install the assembled blade and blade holder to the fan motor Hand tighten securely BLADE HOLDER Repete for each assembly SCREW 2 PER BLADE Step 13 Attach the pull chain fob HOLDER PROCEED TO YOUR FAN S CONTROL FEATURE SECTION ON THE PAGE 13 FOUR SEASONS III OUTSIDE USA INSTALLATION If you do not have an existing fixture located where you wish to place your Casablanca fan a new ceiling fixture outlet box must be installed use an outlet box marked acceptable for fan support and an electrical cable to run it This box must be secured to the ceiling according to the outlet box manufacturer s instructions It is recommended that this be done by a qualified electrician Vaulted or Cathedral Ceiling Installations Your Casablanca fan may be installed on a vaulted or cathedral ceiling in the same manner as described for a flat ceiling The Hang Tru mounting system makes it possible to hang your fan on sloped ceilings up to a 32 angle Using Existing Ceiling Fixture Outlet Box After turning electrical power off lower the old fixture to expose the wiring and the ceiling fixture outlet box Cut the fixture wires or if wire nuts have been used unscrew them and disconnect the wires T
3. SCREW 3 PER BLADE Step 20 Attach the pull chain fob PROCEED TO PAGE 13 FLAT WASHER e 3 PER BLADE BLADE HOLDER SCREW 2 PER BLADE HOLDER 3 SPEED 3 SPEED W 4 WALL CONTROL OF THE FAN The W 4 allows the choice of four 4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by the W 4 wall control CAUTI ON Failure to set the pull chain speed to HIGH can result in faulty operation of the fan and damage to the W 4 wall control To confirm fan is set to HIGH Turn W 4 fan speed switch to HI set fastest fan speed with pull chain WHITE 120V AC BLACK BLACK GREEN v GROUND a mM lity MN WIRE NUT 2 BLACKS gt gt 2 WHITES CAP BLUE D1 OPTION BLACK W 4 WALL CONTROL BLACK FAN PULL CHAIN SWITCH i CAPPED BLUE D1 OPTION CAPPED V N WHITE WHITE BLACK 3 SPEED W 8 WALL CONTROL OF THE FAN amp LIGHT S The fan may be turned ON and OFF by the W 8 wall control The lights may be turned ON and OFF by the W 8 and the intensity adjusted from low to high The fan must be supplied with two independent 120V AC supply wires Set the FAN pull chain switch to the HIGH speed setting Turn the lights ON at the fan The W 8 allows the ch
4. Using Existing Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish After turning the power OFF at its source either circuit breaker to place your Casablanca fan an approved ceiling fixture or fuse box lower the old fixture and disconnect the wiring outlet box must be installed and wired Check the ceiling fixture outlet box to be sure that it is WARNING To reduce the risk of fire electrical shock marked Approved for ceiling fan mounting If it is not a new or personal injury mount to outlet box marked box must be installed acceptable for ceiling fan support using the TEE mounting hardware provided with the outlet box NOTE The fan weight is 17 pounds screw may cause the fan to separate from the downrod during normal operation FOR FAN INSTALLATION OUTSIDE THE EXCLUDING MODELS ENDING IN E Proceed with installation as follows Step 1 Route the wires from the ceiling outlet box through the crossbar mounting bracket center hole Attach the bracket with ground wire and ridges down to the ceiling fixture outlet box with the mounting hardware included with the outlet box Tighten the screws firmly by hand only being careful not to bend the bracket by over tightening CAUTION To reduce the risk of CEILING FAN USA GO TO PAGE 8 WIRING BOX APPROVED FLAT personal injury use only the WASHER Peri mounting hardware provided with WI
5. cleaned Be sure to turn power to the fan OFF at the wall switch or circuit in the same manner breaker before changing light bulbs Replace bulbs with same type as removed from the fixture Each fan is rated for a maximum TOTAL Blades Wood finish blades should be cleaned with a furniture pol wattage of lighting ishing cloth Occasionally a light coat of furniture polish may be Exceeding the rated maximum allowable wattage for the fan will applied for added protection and beauty burn out the fan electronics module and void the warranty PROBLEM POSSIBLE REMEDIES FAN WILL NOT START Check main circuit fuses circuit breakers or wall switch position Check all wire connections making sure the power is turned off during this inspection Check that reverse switch is not set in center of throw FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into the slot on the ball EXCESSIVELY Check the screws holding the blade holders to the flywheel or direct drive motor Tighten as necessary Check that bladeholders have not been bent during installation FAN NOISY DURING Check and tighten light fixture retaining screws glass shade screws and or the light bulb s as neccessary OPERATION Tighten the blade to bladeholder screws Tighten canopy screws and mounting plate assembly Check and tighten blade holders to flywheel or direct drive motor Make sure all screws in the motor housing are snug but not overly tight Check that the wire
6. details BE Note Fan may wobble or vibrate if EXAMPLE 1 pole length is not long enough and This slope is less than 32 It is OK to install your fan EXAMPLE 2 This slope is 32 This is the maximum slope that will allow the fan to hang straight down It is OK to install your fan EXAMPLE 3 This slope is more than 32 Your fan will not hang straight down an adaptor is necessary Contact your local Authorized Casablanca Dealer in regards to purchasing a Slope Ceiling Adaptor inside blade is too close to downslope or side wall Extending pole length will usually solve problem Calculation of 32 Use the tear off Ceiling Angle Template card inserted in the back of this manual it provides you with a simple go or no go for installing your fan on a sloped ceiling FOUR SEASONS III PREPARATION INSTRUCTIONS Unpacking Before assembling and installing your ceiling fan remove all parts from the shipping cartons and check them against the parts listed here Before discarding packaging material be certain that all parts have been removed GETTING STARTED Carton Contents The fan carton contains the fan body warranty card owner s Be sure to use only genuine Casablanca blades The blade manual and all the parts necessary to assemble and install shrink wrap holds 5 blades of matched weight If more than your Casablanca ceiling fan These parts are shown at the one fan is being i
7. e Black wire and blue wire from fan to black or red POWER wire in ceiling outlet box e Green leads from crossbar mounting bracket and fan to grounding conductor of power source Secure by threading on the wire nuts provided with the fan NOTE SEE PAGE 12 FOR ADDITIONAL WIRING INSTRUCTIONS OUTLET CANOPY FOUR SEASONS III OUTSIDE USA INSTALLATION OUTSIDE USA SECONDARY SUPPORT COMPLETING INSTALLATION Step 16 Attach the fan cable to outlet box cable with the spring lock hook Make sure the spring lock is tightly closed WIRE NUTS INSTALLED Step 17 Tuck the wires into the canopy with the wire nuts pointed upward so that the white and black wires are on opposite sides of the canopy and all wires are clear of the canopy opening Tuck the extra cable and screw lock hook into the canopy FAN AND OUTLET with plug and socket connectors Substitute these connectors CABLES SECURED BY for the wire nuts shown throughout this manual SPRING LOCK HOOK Qw Kc BLADE SCREW FLAT WASHER BLADE HOLDER SCREW 3 PER BLADE 3 PER BLADE 2 PER BLADE 0 SA BLADE amp BLADE HOLDER INSTALLATION Step 18 Attach the blades to the blade holders with the three blade screws and flat washers provided for each blade Hand tighten securely BLADE HOLDER Step 19 Install the assembled blade and blade holder to the fan motor Hand tighten securely Repete for each assembly BLADE
8. E wire and BLACK power wire from fan to BLACK power 3 GREE wire in ceiling outlet box Secure with wire nut Step 8c W 8 Wiring Connections GREEN leads it mounting plate and fan to GROUND W 8 CONNECTIONS conductor of power source Secure with wire nut BLUE amp YELLOW e WHITE wire from fan to white NEUTRAL wire in ceiling WIRES R fixture outlet box Secure with wire nut e BLACK power wire from fan to RED wire from W 8 in ceiling BLACK amp RED gt outlet box Secure with wire nut WIRES e BLUE wire from fan to YELLOW wire from W 8 in ceiling Z outlet box Secure with wire nut 2 WHITE WIRES NOTE SEE PAGE 12 FOR ADDITIONAL WIRING INFORMATION 3 GREEN WIRES CANOPY HATCH INSTALLATION Step 9 Tuck the wires into the canopy with the wire nuts pointed upwards so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires CANOPY are clear of the canopy opening HATCH Step 10 Install canopy hatch with the LOCK last canopy screw and lock washer To do WASHER this tilt the fan body away from the hatch TILT THE opening Tighten the screws firmly by hand only ety INSTALL Step 11 Straighten the fan then check SANGU to ensure that there is no movement between the canopy and ceiling or Hang Tru ball and top support shaft Mi SCREW Qw H BLADE SCREW FLAT WASHER BLADE HOLDER SCREW 3 PER BLADE 3 PER BLADE 2 PER BLADE BLADE HOLDER
9. Four SEASONSs III OWNERS MANUAL CONTENTS INTRODUCTION 55 aa ian ii sah a Sia nn dr Ala Gow ri SAHAN on a RR r all RR Ja A MA A A Ro WAN TA JE on Tag a RTR NAN 1 MOUNTING RECOMMENDATIONS suaran nan anan nn nan ara aa nan nan anna nn nana nn KKR Reds 2 PREPARATION INSTRUCTIONS ww ccc eee 3 FAN INSTALLATION USA ccc cette eee anana eee eee eee eee eee eee 4 FAN INSTALLATION OUTSIDE USA 1 cece eect anna anna ana eee eens 8 CONTROL FEATURES 3 SPEED CONTROL WIRING ccc ccc eee tee eee 12 3 SPEED OPERATIONS 557255 550 66 08 555 eh 06 SE ane s ren Gan TA SA a YEN aah a a SAR SAE Ti eT ek wae 13 TROUBLESHOOTING 5 5 iri ii dipuh sai or dg eae Jr dial aural ae mg JEN ah ah ae ace ne AGA aaa Ana A a JR 14 SAFETY FIRST Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation therefore before attempting to install and operate your Casablanca fan read this owner s manual completely and carefully Retain this manual for future reference CAUTION To avoid possible electrical shock make certain that electricity is turned off at the circuit breaker or fuse box before attempting any installation procedure BEFORE YOU START All wiring must be in accordance with the National Electric Code ANSI NFPA 70 1993 and the appropriate local electrical codes The National Electric Code requires proper grounding as a precaution against electrical shock A
10. RE the approved outlet box to install the crossbar mounting bracket APPROVED OUTLET BOX HARDWARE CANOPY HARDWARE TMM CANOPY SCREW 4 r CANOPY NG HATCH CANOPY INSTALLATI ON Step 2 Attach the canopy to the crossbar mounting bracket with three of the 8 32 x 21 4 long canopy screws and canopy lock washers Tighten the screw firmly by hand only NOTE On sloped ceilings align the canopy opening towards the top or room peak 0 CANOPY LOCK WASHER 4 CANOPY LOCK WASHER CANOPY SCREW A mn ma Gg CROSSBAR MOUNTI NG BRACKET FOUR SEASONS SWITCH HOUSING INSTALLATI ON SWITCH HOUSING TIP The packing styrofoam makes a handy work bench Remove the bottom foam from the box Step 3 Outside USA Excluding Models Ending in E Note If you have a fan with a secondary support steel cable running through your fan motor go to Page 8 CONNECTOR PLUG STEEL CABLE OUTSIDE USA SWITCH INSTALLATION HOUSING CONNECTOR MOUNTING Win SOCKET Step 4 Hold the switch housing close to the fan and connect the motor plug to the switch housing socket The connectors are keyed to ensure correct alignment during installation Do not force Step 5 Remove the three mounting screws from the switch housing plate ready for the next step O SWITCH HOUSING INSTALL Step 6 Position the switch housing assembly on the switch housing plate and a
11. es with a depth of 2 or greater Not for use with single pull chain fan light option wiring D To install a W 4 wall control in place of an existing wall switch follow the instructions on the W 4 package Note No rewiring is required if the fan is replacing an existing light fixture Operation of the fan from the wall switch is simple 1 Turn knob to obtain desired speed setting CAUTION Failure to set the pull chain speed to HIGH can result in faulty operation of the fan and damage to the W 4 wall control To confirm fan is set to HIGH Turn W 4 fan speed switch to HI set fastest fan speed with pull chain 3 SPEED OPTIONAL WALL CONTROL W 8 The W 8 wall control provides separate control of fan and light with two separate knobs from a convenient wall location The W 8 is designed to replace a standard wall switch and wall boxes with a depth of 2 or greater Requires two hot leads from wall box to ceiling wiring D box io pa en To install a W 8 wall control in place of an existing wall switch follow the instructions on or H the W 8 package Operation of the fan from the wall switch is simple 1 Turn the upper knob to the desired fan speed SA 2 Turn the lower knob to the desired light setting e CAUTION Failure to set the pull chain speed to HIGH can result in faulty operation of the fan and damage to the W 8 wall control To confirm fan is set to HIGH Turn W 8 fan
12. he fixture can then be removed After removing the old fixture check the outlet box to sure that it is supported by a joist or beam across its upper surface If not a 2 x 4 stud must be installed OUTSIDE USA SECONDARY SUPPORT I NSTALLATION PARTS OUTLET oF cm C5 ADAPTOR o Oe PLATE 2 2 6 OUTLET BOX CABLE 3 7 LAG SCREW 5 FENDER PRING LOCK i WASHER gt ock OUTSIDE USA MOUNTING SECONDARY SUPPORT PARTS TO OUTLET BOX WARNING MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT ADVERTI SSEMENT ASSEMBLER UNIQUEMENT A UNE BOITE DE SORTIE J UGEE ACCEPTABLE POUR RETENIR UN VENTILATEUR Before beginning Step 1 follow Steps A C on Page 3 Step 1 Remove the knockout plug in the center of the outlet box or drill a hole for the lag screw to pass through Then drill a guide hole into the joist or beam to a depth of 3 inches Step 2 Route the outlet box wires through the diameter outer hole of the outlet adaptor plate Step 3 Line up the slotted holes and four canopy screw holes in the crossbar mounting bracket and outlet adaptor plate with the 8 32 mounting holes in the outlet box Install the two 8 32 X 2 1 screws and flat washers in fan hardware kit and tighten securely by hand only Step 4 With fender washer and outlet box cable attached as shown pass lag screw through center hole of outlet adaptor plate and screw into pre drilled guide ho
13. ith the holes in the plate Secure the switch housing assembly by reinstalling the three screws removed in the previous step CAUTION Do not pinch wires between the switch housing assembly and the plate SWITCH HOUSING SWITCH HOUSING CONNECTOR CABLE SOCKET CLAMP amp SCREW MOTOR CONNECTOR SECONDARY PLUG Q 7 SUPPORT CABLE SD SWITCH HOUSING MOUNTING SCREW Step 12 Attach the canopy to the crossbar mounting bracket behind the installed outlet adaptor plate with three of the 8 32 x 21 2 long canopy screws and lock washers provided with your Casablanca fan Hand tighten until snug against the ceiling NOTE On sloped ceilings align the canopy opening toward the top or peak of the room Step 13 Attach the spring lock hook to the fan cable by depressing the spring lock and clipping onto the loop at the end SPRING LOCK HOOK FEED OUTLET BOX CABLE AND OUTLET BOX WIRES THROUGH CANOPY OPENING OUTSIDE USA SECONDARY SUPPORT HANGING THE FAN Step 14 To hang the fan body in the canopy hold the fan body firmly and insert the nylon ball into the canopy opening Rotate fan body until slot on nylon ball fits into pin opposite canopy opening Step 15 Attach the fan wires to the ceiling outlet box wiring by twisting the bare ends of the wiring together e White wire from fan to white NEUTRAL wire in ceiling outlet box
14. le of joist Tighten until outlet box is firmly mounted TIP Threading two of the canopy screws into the crossbar mounting bracket will help everything stay aligned as you tighten the lag screw Remove them before starting Step 12 y GUIDE wa NG o a AN BOK CROSSBAR MOUNTING BRACKET OUTLET ADAPTOR PLATE 8 32 X 27 1 SCREW FENDER 6 OUTLET BOX WASHER CABLE FOUR SEASONS III OUTSIDE USA INSTALLATION i SECONDARY SUPPORT PREPARING THE SWITCH HOUSING OUTSIDE USA Step 5 Hold the switch housing close to the fan and connect the motor plug to the switch housing socket The connectors are keyed to ensure correct alignment during installation Do not force Step 6 Locate the blue and white LIGHT wires in the switch housing Make sure they are NOT connected Step 7 Check the tightness of the Cable Clamp amp Screw The clamp should not slip along the cable Step 8 Tape completely over the end of the Cable Clamp and the end of the Secondary Support Cable with electrical tape TAPED OVER CABLE CLAMP amp SCREW Step 9 Pull the cable through the other side of the fan to snug the cable clamp This makes it easier to install the switch housing Step 10 Remove the three mounting screws from the switch housing plate Keep them for the next step Step 11 Position the switch housing assembly on the switch housing plate and align the holes in the switch housing w
15. lign the holes in the switch housing with the holes in the plate Secure the switch housing assembly by reinstalling the three screws removed in the previous step CAUTION Do not pinch wires between the switch housing assembly and the plate g MOUNTI NG 3 ATION Step 7 To hang the fan body in the canopy hold the fan body firmly and insert the ball into the canopy opening Check that no wires were pinched Rotate the fan body until the slot in the nylon ball fits into the pin opposite the canopy opening NOTE The fan weight is 17 pounds NOTE Independent control of the light fixture using a W 8 requires an additional power wire run from the wall switch to the fan See Page 12 for wiring CAPPED BLUE D1 OPTION WIRE ON 3 SPEED ONLY FOR INDEPENDENT W 8 LIGHT CONTROL CANOPY ELECTRICAL CONNECTIONS Step 8a Attach the fan wires to the ceiling fixture outlet WIRE NUT PULL CHAIN OR box wiring by twisting the bare ends of the wires together W 4 CONNECTIONS and then securing with a wire nut Test that the connection is secure by pulling on the wire nut Connect in this order 2 BLACK amp BLUE Step 8b Pull Chain or W 4 Wiring Connections D1 OPTION WIRES e GREEN leads from mounting plate and fan to GROUND WITHOUT W S IN conductor of power source Secure with wire nut e WHITE wire from fan to white NEUTRAL wire in ceiling fixture 2 WHITE WIRES outlet box Secure with wire nut e BLU
16. nstalled be sure not to mix blade sets start of each installation section Before you start go through this Owner s Manual and confirm that you have all the parts CAUTION When removing the shrink wrap shown in each section be careful not to scratch the blades PERMA LOCK HARDWARE DOWNROD amp BALL ASSEMBLY ALLEN SET SCREW Y4 20 x Ya 3mm PRE INSTALLED ALLEN WRENCH FAN PREPARATION IMPORTANT SAFETY INFORMATION BEFORE STARTING THE INSTALLATION OF YOUR CEILING FAN INSTALL THE THREADED DOWNROD INTO THE MOTOR COUPLING AND LOCK THE ASSEMBLY MOTOR WIRES Prepare for fan installation as follows Step A Route the wires from the motor through the GROUND PermaeLock downrod and ball assembly WIRE Tip The downrod has a tapered thread that is designed to lock completely when DOWNROD correctly installed amp BALL ASSEMBLY Step B Using the provided allen wrench loosen the set screw several turns to allow installation of the downrod Thread TAPERED the downrod into the motor coupling until it stops turning THREAD this will take at least four and a half full turns Step C Securely tighten the set screw with the provided allen ALLEN wrench to ensure safe operation of your fan SET SCREW CAUTION Failure to fully lock in the down 4 MOTOR rod before securely tightening the allen set NG J C GETTI NG STARTED Installing a New Ceiling Fixture Outlet Box
17. nuts inside the canopy and switch housing are not touching the metal parts or have fallen off the wire splices Tighten or adjust as necessary BREAK IN PERIOD Let fan run at high speed for two 2 hours DOES NOT RUN ON If new break in may be required run at higher speed for several days LOW SPEED FAN RUNS SLOWLY IN EITHER DIRECTION IF ROTATION IS STARTED BY HAND WILL NOT REVERSE Defective reverse switch defective capacitor or open motor winding Replace reverse switch assembly replace PCB assembly or replace motor unit FAN WILL NOT OPERATE AT PROPER SPEEDS OR WILL NOT OPERATE AT ANY SPEED Defective three speed pull chain switch assembly or defective capacitor Replace three speed pull chain switch assembly or replace PCB assembly For questions or to locate the nearest Casablanca Authorized Service Center call toll free 1 888 227 2178 or visit us on the web at www CasablancaFanCo com FAN COMPANY 761 Corporate CENTER DRIVE Pomona CA 91768 ToLL Free 888 CASA 1ST 227 2178 www CasablancaFanCo com CopyriGHt 1999 CASABLANCA Fan Company U S PATENT PENDING PRINTED INROC
18. oice of four 4 different speed settings CAUTION Failure to set the pull chain speed to HIGH can result in faulty operation of the fan and damage to the W 8 wall control To confirm fan is set to HIGH Turn W 8 fan speed switch to HI set fastest fan speed with pull chain BLACK SWITCH BLUE amp BLUE D1 OPTION W 8 WALL CANOPY BLACK WHITE 120V AC Ball v GROUND Mm dih ULN i 4 WIRE NUT RED YELLOW amp RED 2 WHITES lt YELLOW amp BLUE RED YELLOW P1 OPTION N CONTROL FAN PULL CHAIN SWITCH a 3 SPEED 3 SPEED OPERATION Pull chain switches on the fan control the fan and lights Using the fan control pull chain switch Fan off at start e First pull fan ON low speed OPTIONAL LIGHT FAN amp SPEED PULL CHAIN CONTROL e Second pull medium speed SWITCH PULL CHAIN SWITCH Third pull high speed e Fourth pull fan OFF Using the optional light pull chain switch Light off at start e First pull light ON e Second pull light OFF Direction of blade rotation is controlled by the reverse slide switch on the side of the switch housing REVERSE No changes in household wiring are required SWITCH 3 SPEED OPTIONAL WALL CONTROL W 4 The W 4 wall control provides four speed control of fan from a convenient wall location The W 4 is designed to replace a standard wall switch and will fit wall box
19. qualified electri cian should be consulted if you are unsure e This fan is designed to be installed on an existing electrical outlet box The outlet box must be UL Listed for ceiling fan installations if it is not a new box must be installed Casablanca extension poles are available for sloped or high ceiling installations This ceiling fan requires a grounded electrical supply of 120 VAC 60 Hz and a minimum 15 amp circuit The maximum current requirement for the fan with light fixture is 3 8 amps The fan uses about 1 amp or 100 watts Maximum light current is 2 8 amps or 340 watts of lighting Where wire nuts are employed be sure all bare wires are within the connectors When installing the canopy hatch make sure all wires are within the canopy and that no wires are being pinched For best performance and for your warranty to be valid use only genuine Casablanca blades light fixtures and accessories The blades in each pack are matched for equal FUSE BOX weight to assure smooth fan operation If REMOVE FUSE FOR THE more than one fan is being installed be CIRCUIT YOU WILL BE careful not to mix blades from different WORKING ON cartons Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer It is always a good idea to have an assistant to help with the installation When cleaning painting or working near your fan be ve
20. ry careful of the fan and blades CIRCUIT BREAKER 84 Always turn the power OFF to the ceiling fan TRIP BREAKER FOR THE before servicing it working on it or replacing CIRCUIT YOU WILL BE 00000 light bulbs WORKING ON e Never insert anything into the path of the fan blades while the fan is in operation FH e Never install a fan over a pool or spa SE ME Never operate a fan that has been damaged in any way Contact Casablanca Fan Company by calling toll free 1 888 227 2178 or contact your local authorized Casablanca dealer for assistance in obtaining service P N 8943150 REV B P D MAROOPDG MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan read the following helpful recommendations The location of the fan air circulation and fan size are all important factors to consider before installation Location Ceiling fans have practical uses in almost every room in your home We suggest you follow these mounting recommendations as you decide where to install your Casablanca fan e For safety reasons the fan blades must be a minimum of 7 above the floor e Do not locate the fan in a doorway or above a swinging door e In any installation the tips of the blades must be at least 18 from the wall in order to provide sufficient clearance for the blades In bedrooms fans work best when mounted abo
21. ve the foot of the bed Over pool tables be sure to provide plenty of clearance to avoid damage from pool cues e In low ceiling locations our optional Low Ceiling Adaptor LCA available at f extra cost can be used to gain 31 4 9 e In kitchens be sure to allow for open cupboard doors to clear the fan blades DINING ROOM Do not install a fan close to or over a pool or spa High humidity combined FawiSizeorrosive fee will destroy the finish and warp the blades Variable fan speed capability permits the use of a full size 52 fan even in smaller rooms For very large rooms two fans may be needed SLOPED CEILING INSTALLATI ONS MAXI MUM HANG TRUQ ANGLE 322 Suggested Extension Pole Lengths Ceiling Height Pole Length 8 Standard Standard BLADES MUST BE A MINIMUM OF 7 ABOVE THE FLOOR When to Use Extension Poles 7 MINIMUM For best performance and best appearance an extension pole should be used with your Casablanca fan when installing on YNZ high cathedral ceilings or sloped ceilings Casablanca offers standard poles Cs in increments of 6 up to 5 Custom poles are available in lengths up to 10 See your ZI Authorized Casablanca Dealer for
Download Pdf Manuals
Related Search
Related Contents
Samsung RS277ACRS User Manual Bosch MON170CL User's Manual Philips 30PW8869 Flat Panel Television User Manual Junio - INIFAP Zacatecas - Instituto Nacional de Investigaciones Light 2eーt pass`formation 2014 Enterovirus Real Time RT-PCR Kit User Manual For In Vitro Philips SMARTSPOT Recessed spot light 59663/17/16 Copyright © All rights reserved.