1. If any parts are missing contact your loca retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly LOOSE HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET COUPLING COVER How to Put Your Ceiling Fan Together 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 1 Remove the pin from the cownrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in step 5 C 5 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 3 Figure 1 2 Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downred 3 Remove the setscrew Figure 2 from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the cle vis pin and secure with the hairpin clip Figure 2 The clevis pin must go through the holes in the motor coupling and the holes in the downrod
2. GREEN WIRE BLACK SUPPLY GROUND FROM HOT HANGER BALL Figura 12 length optional Connect the wood pendant sup plied to the 3 speed switch pull chain by sliding the wooden pendant small hole first onto the pull chain Attach the chain coupling to the end of the chain and allow the wooden pendant to fall down over the coupling Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the pull chain switch a 3 All fans are shipped from the factory with the reversing switch positioned to the left circulate air downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades to stop turning then slide the reversing switch to the right position and turn fan on again el 4 The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows Three Speed 1st Pull HIGH 2nd Pull Mecium ome So 3rd Pull Low REVERSING CHAIN 4th Puli OFF i Reverse Switch Information Season Rotation Direction Switch Position Summer Counter Clockwise Left Winter Clockwise Right Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan H
3. could result in personal Injury or property damage WARNING To reduce the risk of personal Injury do not hend the blade flange when Installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan NOTE All setscrews must be checked and re tlghtened where necessary before installation DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder One 1 4 blade screwdriver One wire stripper Three wire connectors supplied MATERIALS Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of following size l j Wire Size A W G Up to 50 ft 14 50 100 ft 12 A WARNING Before assembly your ceiling fan refer to section on proper method of wiring your fan page 7 If you feel you do not have enough wiring knowledge or experi ence have your fan installed by a licensed electrician Unpacking Instructions Fo
4. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed 44 WARNING It Is critica that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling MOTOR COUPLING SETSCREW gt DR 4 Reinstall the setscrew in the motor coupling While pulling up on the hanger bail securely tighten the setscrew NOTE The setscrew must be properly installed as described above or fan wobble could result Figure 2 gt f 8 Oo Figure 3 6 Reinstall the hanger bail Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble A WARNING It is critical that the pin In the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pln and setscrew are prop
5. E SCREW 2 i 7 Lh a Figure 6 i J a 11 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws in a clockwise sequence If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again Figure 7 Figure 8 Engage the connector of the switch housing assembly with the motor connector Figure 7 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the con nector latch closes properly L Saf he SWITCH HOUSING ASSEMBLY N J SZ JA f ay Gs 476 1 EQS 2 AS Lomas SWITCH HOUSING mea ky CONNECTOR SB gt SWITCH HOUSING GE MOUNTING SCREW 3 ee SIR AON Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three mounting screws Figure 8 NOTE Do not pinch wires between the switch housing assembly and the switch housing plate SWITCH HOUSING ASSEMBLY You have now completed the assembly of your new ceiling fan You can now proceed with hang ing and wiring your fan El
6. READ AND SAVE THESE INSTRUCTIONS Ceiling Fan Owner s Manual Net Weight 21 1 Lbs READ AND SAVE THESE INSTRUCTIONS Safety Instructions 4 WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOW ING a Use this unit only in a manner intended by the man ufacturer If you have questions contact the manu facturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnect ing means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and keep it for future reference 2 Be careful of the fan and blades when cleaning paint ing or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades whlle they are turning 4 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2011 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceillng fan must be grounded as a p
7. all connections are tight including lf you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 4 WARNING To avoid possible electrical shock be sure electricity Is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electriclan for advice as it must be grounded for safe operation C 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 13 C 1 Connect the green grounding lead from the hanger bail and the green grounding lead from the hanger 5 bracket to the grounding conductor of supply this O may be a bare wire or wire with green colored insulation Securely connect wires with wire con nectors supplied Figure 12 NOTE f you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual Secure the ceiling cover in place by sliding lock washers over the threaded studs and installing the two knurled knobs supplied Figure 13 Tighten the knurled knobs securely until the ceiling cover fits snugly against t
8. ectrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptabie for fan support and may need to be replaced Consult a qualified electrician If in doubt The outlet box must be securely anchored and capa ble of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 4 WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instruc tions should be done or approved by a licensed electrician How to Hang Your Ceiling Fan 4 WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 9 PER Trane AT ST Figure 9 a FLOOR cep 44 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7kg 50 Ibs or less 44 WARNING To reduce the risk of fire electric shock or personal injury mount fan t
9. er ly installed could result in the fan falling PIN DOWNROD CEILING COVER 7 The fan comes with blue black and white leads that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads Mount blade flanges to fan blades using three MS x 6 washer head screws and three blade washers Figure 5 a warned To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades M5 x 6 WASHER HEAD SCREWS igs BLADE WASHERS 3 a FAN BLADE X q SNY AN Figure 5 BLADE FLANGE NOTE Take care not to scratch fan housing when installing blades E 13 9 Turn the fan assembly upside down in preparation for mounting the fan blade assemblies NOTE Remove and discard the four shipping spacers and screws from the motor hub 10 Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate Loosely attach one blade assembly to the motor hub using two M6 x 14 flange screws preassem bled in flange Make sure the screws are NOT tightened Figure 6 Repeat this procedure for the other four blade assemblies J YS BLADE U DN z e I SWITCH N Rn aa FLANGE aa 14 J FLANG
10. ere are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and i8 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Retailer for optional mounting accessories Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In ihe winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or tint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and s
11. he ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan for wiring switch 4 WARNING CEILING This product Is designed to use only those parts COVER supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces THREADED sories not designated for use with this product by STUD LOCKWASHERS 2 Emerson Electric Co could result in persona injury Figure 13 CS KNURLED KNOB or property damage WARNING 2 Securely connect the fan motor white wire to the To avoid possible fire or shock make sure that the elec supply white neutral wire using wire connector supplied Figure 12 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 42 After connections have been made turn leads trical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 6 Cut the 3 speed switch pull chain to a desired upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box NOTE CEILING COVER OMITTED FOR CLARITY BLACK AND BLUE eRoUND FANWIRES _ yer WIRE WHITE SUPPLY NEUTRAL GREEN WIRE GROUND FROM ANGER BRAGKET MTE FAN
12. hould be avoided to prevent damage to finish A WARNING Do not use water when cleaning your celling fan It could damage the motor or the blades and create the possibility of an electrical shock
13. o outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 4 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall OUTLET BOX TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET Figure 10 7 gt TAB 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 11 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 10 44 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard alee NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED De FOR CLARITY HANGER BRACKET Figure 11 HANGER BALL DOWNROD ASSEMBLY 4 WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket How to Wire Your Ceiling Fan 4 WARNING Check to see that
14. r your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will Insure that all steps have been completed and will be helpful in finding your place should you be interrupted 44 WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 4 WARNING This product Is deslgned to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or acces sories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage Es 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration Fan motor assembly One switch housing assembly Five fan blades One ceiling cover Five blade flanges One hanger ball downrod assembly One hanger bracket One coupling cover One loose parts bag containing 1 Sixteen M5 x 6 washer head blade screws 2 Sixteen blade washers One M6 x 14 flange screw One wood pendant One coupling Three wire connectors Two threaded studs Two lockwashers Two knurled knobs One clevis pin One hairpin clip Toe oacnryw DOMNDORW l l NOTE Place the parts from the loose parts bags in a small container to keep them from being lost
15. recaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and Jolst must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7kg 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceillng fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be Installed with an isolating wall control swltch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson