1. Controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off Speed settings for warm or cool weather depend on factors such as the room size ceiling height and number of fans SLIDE SWITCH Controls directions forward switch down or reverse switch up NOTE Wait for fan to stop before changing the setting of the slide switch Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 12 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off the ceiling area as shown in Fig 13 This allows you to set your heating unit on a cooler setting without affecting your comfort WALL SWITCH OPTIONAL Your fan is also designed to operate with a wall switch sold separately Refer to wall switch instructions for installation and wiring information Page 6 ae ae NX UA FIGURE 12 7 ewe FIGURE 13 Nulone MODELS CFH52BS CFH52PB CFH52RB CFH52WH MAINTENANCE IMPORTANT MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT ANY REPAIRS REFER TO THE SECTION CONNECT WIRING Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove fan from ceiling Clean your fan peri
2. Deje pasar un per odo de 24 horas de adaptaci n La mayor a de los ruidos de un ventilador nuevo desaparecen con el tiempo Si utiliza un kit de iluminaci n opcional aseg rese de que los tornillos que sujetan la pieza de vidrio queden bien ajustados Verifique que la l mpara tambi n est firmemente colocada Los motores de algunos ventiladores son sensibles a las se ales de dispositivos de control de velocidad variable con semiconductores Si ha instalado este tipo de control elija e instale otro tipo de control Aseg rese de que la carcasa superior quede a poca distancia del techo No debe tocar el techo El ventilador se bambolea 1 2 Verifique que todas las paletas y los tornillos de los brazos de las paletas est n bien ajustados La mayor a de los problemas de bamboleo se debe a que las paletas est n desniveladas Para verificar los niveles seleccione un punto en el techo sobre la punta de una de las paletas Mida esta distancia Rote el ventilador hasta que la siguiente paleta quede posicionada en ese punto para medirla Repita esta operaci n con cada una de las paletas La desviaci n de distancia debe ser igual en un radio de 1 8 0 3 cm Utilice el kit de nivelaci n de paletas si el bamboleo de las paletas contin a Si a n percibe el bamboleo de las paletas puede intercambiar dos paletas adyacentes lado a lado para redistribuir el peso y obtener un funcionamiento m s suave ADVERTENCIA
3. FAN OPTIONAL LIGHT KIT style may vary 120 VAC OPTIONAL LINE IN WALL CONTROL BLK GREEN Tan T ba 1 GROUND WIRING BOX cau aaa dak GROUND TO MOUNTING BRACKET OR DOWNROD OPTIONAL LIGHT KIT style may vary FIGURE 8 Nutone MODELS CFH52BS CFH52PB CFH52RB CFH52WH FINISH INSTALLATION 1 Swing the motor assembly up into position under the mounting bracket Secure the bracket to the plate with the screws provided Fig 9 Carefully lift the motor housing onto the mounting bracket properly align the holes and tighten the motor housing with the 4 screws supplied Fig 10 ATTACH FAN BLADES Your fan is equipped with 2 sided reversible blades Select the finish and install the blade brackets over the side of the blades that will be visible 1 Attach the blade to the blade bracket using the screws and fiber washers as shown in Figure 11 Start screw into bracket Repeat for the two remaining screws Tighten each screw Make sure the blade is straight Fasten blade assembly to motor using the screws supplied Fig 11 Page 5 MOUNTING BRACKET ae 4 lt SCREWS MOTOR i HOUSING io x SCREWS FIGURE 10 oh J FIBER 4 i f washers SCREWS i BADE BLADE BRACKET x FIGURE 11 N U O l e MODELS CFH52BS CFH52PB CFH52RB CFH52WH OPERATION Turn on the power and check the operation of your fan 3 SPEED PULL CHAIN
4. PARA REDUCIR EL RIESGO DE LESIONES NO DOBLE LOS BRAZOS DE LAS PALETAS AL INSTALARLAS NIVELARLAS O AL LIMPIAR EL VENTILADOR NO INSERTE OBJETOS EXTRANOS ENTRE LAS PALETAS DEL VENTILADOR MIENTRAS ESTEN ROTANDO Pagina 15 CLAVE N DE PIEZA DESCRIPCI N 1 77000911 JUEGO DE PALETAS INCLUYE 5 CFH52WH 77000912 JUEGO DE PALETAS INCLUYE 5 CFH52BS 77000913 JUEGO DE PALETAS INCLUYE 5 CFH52PB S77000914 JUEGO DE PALETAS INCLUYE 5 CFH52RB 2 S77000921 INTERRUPTOR DE CADENILLA DE TIRO CADENA DE BRONCE PULIDO S77000922 INTERRUPTOR DE CADENILLA DE TIRO CADENA CROMADA S77000923 INTERRUPTOR DE CADENILLA DE TIRO CADENA DE BRONCE DE CA N 3 S77000926 CUENTAS DE MADERA C CADENA CADENA DE BRONCE PULIDO S77000927 CUENTAS DE MADERA C CADENA CADENA CROMADA S77000928 CUENTAS DE MADERA C CADENA CADENA DE BRONCE DE CANON 4 S77000919 INVERSOR 7 CABLES BLANCO S77000920 INVERSOR 7 CABLES NEGRO 5 S77000907 JUEGO DE SOPORTES DE PALETAS INCLUYE 5 CFH52WH S77000908 JUEGO DE SOPORTES DE PALETAS INCLUYE 5 CFH52BS S77000909 JUEGO DE SOPORTES DE PALETAS INCLUYE 5 CFH52PB S77000910 JUEGO DE SOPORTES DE PALETAS INCLUYE 5 CFH52RB 6 577000915 BOLSA DE PIEZAS CFH52WH 577000916 BOLSA DE PIEZAS CFH52BS S77000917 BOLSA DE PIEZAS CFH52PB 577000918 BOLSA DE PIEZAS CFH52RB il S77000925 CONDENSADOR 4 5uf300VCA 6 5uf 250VCA no hay ilustraci n cy 1 2 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH P
5. choose and install another type of control 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling Fan wobbles 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance Rotate the fan until the next blade is positioned for measurement Repeat for each blade The distance deviation should be equal within 1 8 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable 4 If the blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation WARNING TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE ARM WHILE INSTALLING BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES Page 7 SERVICE PARTS KEY PART NO DESCRIPTION 4 S77000911 BLADE SET CONTAINS 5 CFH52WH S77000912 BLADE SET CONTAINS 5 CFH52BS S77000913 BLADE SET CONTAINS 5 CFH52PB 577000914 BLADE SET CONTAINS 5 CFH52RB S77000921 PULL CHAIN SWITCH POLISHED BRASS CHAIN S77000922 PULL CHAIN SWITCH CHROME CHAIN S77000923 PULL CHAIN SWITCH GUNMETAL CHAIN 577000926 WOOD BEAD W CHAIN POLISHED BRASS CHAIN S77000927 WOOD BEAD W CHAIN CHROME CHAIN S77000928 WOOD BEAD
6. gina 16 GARANT A Ventiladores de techo y accesorios NuTone Garant a limitada PERIODO DE GARANT A NuTone garantiza al consumidor comprador original de sus ventiladores de techo y accesorios NuTone que estar n libres de defectos en materiales o mano de obra durante un per odo de un 1 a o a partir de la fecha de la compra original Esta garant a no cubre los globos de vidrio ni las bombillas incluidos con los juegos de luces El periodo de garant a limitada para las piezas de repuesto y para los ventiladores reparados o reemplazados bajo esta garant a limitada continuar durante el resto del periodo de garant a original NO HAY OTRAS GARANT AS LAS GARANT AS ANTERIORES SON EXCLUSIVAS Y EN LUGAR DE CUALQUIER OTRA GARANT A EXPRESA O IMPL CITA NUTONE NIEGA Y EXCLUYE CUALQUIER OTRA GARANT A EXPRESA Y NIEGA Y EXCLUYE TODAS LAS GARANT AS IMPL CITAS POR LEY INCLUYENDO SIN LIMITACIONES LAS DE COMERCIALIZACI N Y APTITUD PARA UN PROP SITO EN PARTICULAR HASTA EL GRADO QUE LA LEY APLICABLE PROH BA LA EXCLUSI N DE GARANT AS LIMITADAS LA DURACI N DE CUALQUIER GARANT A IMPL CITA APLICABLE EST LIMITADA AL PERIODO ESPECIFICADO PARA LA GARANT A EXPRESA Algunos estados no permiten limitaciones en la duraci n de una garant a impl cita as que la limitaci n anterior tal vez no aplique en su caso Cualquier descripci n verbal o escrita del ventilador es para el nico prop sito de identificarlo y no deber considerarse c
7. O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH CABLEADO DE CONEXI N Recuerde desconectar la alimentaci n el ctrica Siga los pasos que se indican a continuaci n para conectar el ventilador a la instalaci n el ctrica de su hogar Utilice las tuercas para alambre suministradas con el ventilador Sujete los conectores con cinta aislante Aseg rese de que no haya hilos ni conexiones sueltos SI INSTALA UN KIT DE ILUMINACI N OPCIONAL CONSULTE LAS INSTRUCCIONES INCLUIDAS CON EL KIT 1 Conecte el cable de alimentaci n del ventilador negro y el cable de alimentaci n de luz azul al cable de alimentaci n de color negro de su instalaci n el ctrica como se muestra en la figura 6 2 Conecte el cable neutro del ventilador blanco al cable neutro de color blanco de su instalaci n el ctrica 3 Conecte el cable a tierra del ventilador verde con el cable a tierra de su instalaci n el ctrica 4 Gire las tuercas de conexi n hacia arriba e introduzca los cables en la caja de distribuci n 5 Sujete la tapa de la carcasa del interruptor a la carcasa del interruptor con los tornillos suministrados Las figuras 7 y 8 ilustran las conexiones de los cables para un control de pared opcional el color de los cables fuera del control de pared podr variar lea el manual de instalaci n del control de pared para conocer las conexiones correctas de los cables ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESC
8. OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR WARRANTY NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY WITH RESPECT TO THE FAN OR NUTONE S ACTS OR OMISSIONS OR OTHERWISE This warranty covers only replacement or repair of defective fans or parts at NuTone s main facility and does not include the cost of field service travel and living expenses Any assistance NuTone provides to or procures for you outside the terms limitations or exclusions of this limited warranty will not constitute a waiver of such terms limitations or exclusions nor will such assistance extend or revive the warranty NuTone will not reimburse you for any expenses incurred by you in repairing or replacing any defective Fan except for those incurred with NuTone s prior written permission HOW TO OBTAIN WARRANTY SERVICE To qualify for warranty service you must a notify NuTone at the address or telephone number stated below within seven 7 days of discovering the covered defect b give the model number and part identification and c describe the nature of any defect in the fan or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 888 336 6151 If you must send the fan or part to NuTone as instructed by NuTone you must properly pack the fan or part NuTone is not responsible for damage in transit 79040059A
9. U OMISIONES DE NUTONE O DE CUALQUIER OTRA NDOLE Esta garant a cubre nicamente el reemplazo o la reparaci n de ventiladores o piezas defectuosas en la planta principal de NuTone y no incluye el costo del viaje para el servicio de campo ni los vi ticos Cualquier asistencia que proporcione o procure NuTone para usted fuera de los t rminos limitaciones o exclusiones de esta garant a limitada no constituir una renuncia a dichos t rminos limitaciones o exclusiones ni dicha asistencia extender o renovar la garant a NuTone no le reembolsar ning n gasto en el que usted haya incurrido al reparar o reemplazar cualquier ventilador defectuoso excepto los incurridos con el permiso previo por escrito de NuTone COMO OBTENER EL SERVICIO CUBIERTO POR LA GARANT A Para tener derecho al servicio cubierto por la garant a usted debe a notificar a NuTone a la direcci n o n mero de tel fono que aparecen abajo en un plazo de siete 7 d as despu s de descubrir el defecto cubierto b proporcionar el n mero de modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el ventilador O la pieza En el momento de solicitar el servicio cubierto por la garant a debe presentar un comprobante de la fecha original de compra Broan NuTone LLC 926 West State Street Hartford WI 53027 888 336 6151 Si debe enviar el ventilador o la pieza a NuTone tal como lo indique NuTone debe empaquetar adecuadamente el
10. cajas de distribuci n utilizadas para aparatos de luz no son admisibles para ventiladores y probablemente deban ser reemplazadas En caso de duda consulte a un electricista calificado S lo utilice cajas de distribuci n homologadas por UL y que indiquen FOR FAN SUPPORT Para ventiladores La caja de distribuci n y la estructura de soporte deben quedar firmemente instaladas y deben soportar un peso m nimo de 50 libras 22 7 kg S lo utilice los dos tornillos de acero y las arandelas de seguridad incluidos con la caja de distribuci n para instalar el ventilador de techo a la caja de distribuci n La caja de distribuci n no debe quedar torcida ni suelta al estar en funcionamiento NO UTILICE CAJAS DE DISTRIBUCI N DE PL STICO 8 Despu s de realizar las conexiones el ctricas debe girar los conductores empalmados hacia arriba e introducirlos con cuidado en la caja de distribuci n Deber separar los cables con el conductor a tierra y el conductor de conexi n a tierra del equipo a un costado de la caja de distribuci n 9 Los planos el ctricos se ofrecen s lo a modo de referencia Los kits de iluminaci n que no est n incluidos en el paquete del ventilador deben estar homologados por UL y deben indicar que son aptos para utilizarlos con el modelo de ventilador que est instalando Los interruptores deben ser de uso general homologados por UL Consulte las instrucciones incluidas con el kit de iluminaci n y los interruptores pa
11. ventilador o la pieza NuTone no se hace responsable por los da os en tr nsito 79040059A
12. 50 pounds Use only the two steel screws and lock washers provided with the outlet box for mounting the ceiling fan to the outlet box The outlet box must not twist or work loose DO NOT USE PLASTIC OUTLET BOXES After marking electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL Listed and marked suitable for use with the model fan you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly After installation is complete make sure that all connections are secure to prevent the fan from falling Make sure all wire connections are secure and that there are no exposed conductor strands Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning CAUTION A TO REDUCE THE RISK OF PERSONAL INJURY OBSERVE THE FOLLOWING 1 2 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit The fan must be mounted with at least 7 feet of clearance between fan blades and floor Make sure that your insta
13. ALETAS El ventilador incluye paletas de doble faz reversibles Seleccione el acabado e instale los soportes de las paletas sobre el lado de las paletas que quedar visible 1 Sujete la paleta al soporte de la paleta con los tornillos y las arandelas de fibra tal como se muestra en la figura 11 Comience a atornillar el soporte Repita la operaci n con los dos tornillos restantes 2 Ajuste firmemente cada tornillo Aseg rese de que la paleta quede derecha 3 Sujete el conjunto de paletas al motor con los tornillos suministrados Fig 11 P gina 13 SOPORTE DE MOTOR EA MONTAJE E NOS ATA AAA SOPORTE DE CARCASA DEL MOTOR Sy TORNILLOS FIGURA 10 TORNILLOS ARANDELAS DE FIBRA a TORNILLOS PALETA SOPORTE DE LAS PALETAS 4 FIGURA 11 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH FUNCIONAMIENTO Encienda la alimentaci n y verifique el funcionamiento de su ventilador CADENILLA DE TIRO DE 3 VELOCIDADES Controla la velocidad del ventilador de la siguiente manera 1 tir n alta 2 tirones intermedia 3 tirones baja y 4 tirones apagado La configuraci n de las velocidades para temperaturas c lidas o fr as depende de diversos factores como el tama o de la habitaci n la altura del techo y la cantidad de ventiladores INTERRUPTOR DESLIZANTE Controla las direcciones adelante interruptor hacia abajo o reversa interruptor ha
14. ARGA EL CTRICA O LESIONES SOLO INSTALE EL VENTILADOR EN UNA CAJA DE DISTRIBUCI N O EN UN SISTEMA DE SOPORTE APTO PARA VENTILADOR P gina 12 ENTRADA DE LINEA 120 VCA CABLE A TIERRA VERDE l CAJA DE CONEXIONES CABLE A TIERRA A SOPORTE DE MONTAJE O BARRA DESCENDENTE VENTILADOR KIT DE ILUMINACION OPCIONAL el estilo podra variar FIGURA 6 ENTRADA DE LINEA 120 VCA CONTROL DE PARED CABLE A TIERRA VERDE OPCIONAL E 1 24 INTERRUP TOR DELUZ NEG asta acne Tees ata a 7 CABLE A TIERRA A SOPORTE DE MONTAJE O BARRA DESCENDENTE VENTILADOR AZUL BCO NEG BCO KIT DE ILUMINACI N OPCIONAL el estilo podr variar FIGURA 7 ENTRADA DE CONTROL L NEA 120 VCA DE PARED g OPCIONAL z 4 CABLE A A a ea TIERRA VERDE TE i LUZ 4 CAJA DE HIHI 1 CONEXIONES Al le CABLE A TIERRA A SOPORTE DE MONTAJE O BARRA DESCENDENTE VENTILADOR KIT DE ILUMINACION OPCIONAL el estilo podra variar FIGURA 8 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH TERMINACI N DE LA INSTALACION 1 Lleve hacia arriba el conjunto del motor hasta su posici n debajo del soporte de montaje Asegure el soporte a la placa con los tornillos suministrados Fig 9 2 Con cuidado levante la carcasa del motor sobre el soporte de montaje alinee los orificios correctamente y ajuste la carcasa con los 4 tornillos suministrados Fig 10 CONEXI N DE LAS P
15. ITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT THAT APPLICABLE LAW PROHIBITS THE EXCLUSION OF IMPLIED WARRANTIES THE DURATION OF ANY APPLICABLE IMPLIED WARRANTY IS LIMITEDTO THE PERIOD SPECIFIED FOR THE EXPRESS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Any oral or written description of the fan is for the sole purpose of identifying it and shall not be construed as an express warranty REMEDY During the applicable limited warranty period NuTone will at its option provide replacement parts for or repair or replace without charge any fan or part to the extent NuTone finds it to be covered by and in breach of this limited warranty NuTone will ship the repaired or replaced fan or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the fan or part to NuTone This warranty does not cover a normal maintenance and service b normal wear and tear c any fans or parts which have been subject to misuse abuse abnormal usage negligence accident improper or insufficient maintenance storage or repair other than repair by NuTone d damage caused by faulty installation or installation or use contrary to recommendations or instructions e any fan that has been moved from its original point of installation f damage caused by en
16. N u O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH VENTILADORES DE TECHO DE LA SERIE HUGGER P gina 9 LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA da A PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES SIGA LAS INDICACIONES QUE SE ENUMERAN A CONTINUACION 1 Utilice esta unidad s lo de la forma indicada por el fabricante Si desea realizar consultas comun quese con el fabricante a la direcci n o al n mero de tel fono que aparece en la garant a 2 Antes de realizar tareas de mantenimiento limpiar la unidad o instalar un kit de iluminaci n apague el interruptor de electricidad desde el panel de servicio y bloquee el panel de servicio para evitar que alguien conecte la electricidad por accidente Cuando el sistema de desconexi n de servicio no se pueda bloquear coloque en el panel de servicio un elemento de advertencia que se destaque como por ejemplo una etiqueta 3 El trabajo de instalaci n y cableado el ctrico deber hacerlo una persona calificada conforme a todos los c digos y est ndares vigentes incluidos los c digos y los est ndares de clasificaci n ign fuga para construcciones 4 Al cortar o perforar en una pared o techo no da e el cableado el ctrico ni otros servicios no visibles 5 Esta unidad debe estar conectada a tierra 6 No utilice este ventilador con ning n dispositivo de control de velocidad de ventiladores con semiconductores 7 La mayor a de las
17. Nulone MODELS CFH52BS CFH52PB CFH52RB CFH52WH HUGGER SERIES CEILING FANS lt READ AND SAVE THESE INSTRUCTIONS WARNING da A TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 NO Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit or installing a light kit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities This unit must be grounded Do not use this fan with any solid state fan speed control device Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced consult a qualified electrician if in doubt Use only UL Listed outlet boxes marked FOR FAN SUPPORT The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of
18. W CHAIN GUNMETAL CHAIN S77000919 REVERSING SWITCH 7 WIRES WHITE 77000920 REVERSING SWITCH 7 WIRES BLACK S77000907 BLADE BRACKET SET CONTAINS 5 CFH52WH S77000908 BLADE BRACKET SET CONTAINS 5 CFH52BS S77000909 BLADE BRACKET SET CONTAINS 5 CFH52PB S77000910 BLADE BRACKET SET CONTAINS 5 CFH52RB S77000915 PARTS BAG CFH52WH S77000916 PARTS BAG CFH52BS S77000917 PARTS BAG CFH52PB 77000918 PARTS BAG CFH52RB S77000925 CAPACITOR 4 5uf300VAC 6 5uf 250VAC Not Shown 4 2 4 3 E 4 Yo ES E N U O l e MODELS CFH52BS CFH52PB CFH52RB CFH52WH Page 8 WARRANTY NuTone Ceiling Fans and Accessories Limited Warranty WARRANTY PERIOD NuTone warrants to the original consumer purchaser of its NuTone Ceiling Fans and Accessories will be materially free from defects in materials or workmanship for a period of one 1 year from the date of original purchase This warranty does not cover glass globes or light bulbs provided with the light kits The limited warranty period for replacement parts and for fans repaired or replaced under this limited warranty shall continue for the remainder of the original warranty period NO OTHER WARRANTIES THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED NUTONE DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND DISCLAIMS AND EXCLUDES ALL WARRANTIES IMPLIED BY LAW INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABIL
19. buidores de EE UU autorizados por NuTone EXCLUSION DE DA OS LA OBLIGACI N DE NUTONE DE SUMINISTRAR PIEZAS DE REPUESTO O DE REPARAR O REEMPLAZAR A OPCI N DE NUTONE SER SU NICO Y EXCLUSIVO REMEDIO BAJO ESTA GARANT A LIMITADA Y LA NICA Y EXCLUSIVA OBLIGACI N DE NUTONE NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES INDIRECTOS RESULTANTES O ESPECIALES QUE SURJAN POR EL USO O DESEMPENO DEL VENTILADOR O EN RELACI N CON EL MISMO Los da os incidentales incluyen entre otros da os como la p rdida de tiempo y la p rdida de uso Los da os resultantes incluyen entre otros el costo de reparar o reemplazar otros bienes que fueran da ados si el ventilador no funcionara adecuadamente Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o resultantes por lo que la limitaci n antes mencionada podr a no aplicarse a usted Esta garant a le otorga derechos legales espec ficos y usted podr a tener otros derechos que var an de un estado a otro Esta garant a sustituye todas las garant as anteriores y no es transferible del comprador consumidor original NUTONE NO SER RESPONSABLE ANTE USTED O ANTE NADIE QUE RECLAME POR USTED DE NINGUNA OTRA OBLIGACI N O RESPONSABILIDAD QUE INCLUYEN ENTRE OTRAS OBLIGACIONES O RESPONSABILIDADES QUE SURJAN POR INCUMPLIMIENTO DE CONTRATO O GARANT A NEGLIGENCIA U OTRO ACTO IL CITO O CUALQUIER TEOR A DE RESPONSABILIDAD ESTRICTA CON RESPECTO AL VENTILADOR O A LOS ACTOS
20. cia arriba NOTA Espere a que el ventilador se detenga antes de cambiar la configuraci n del interruptor deslizante Clima c lido adelante una corriente de aire descendente crea un efecto de enfriamiento como se muestra en la fig 12 De esta forma puede configurar el aire acondicionado en un valor m s alto sin alterar su comodidad Clima fr o reversa una corriente de aire ascendente mueve el aire caliente lejos del rea del techo como se muestra en la fig 13 De esta forma puede configurar el calefactor en un valor m s bajo sin alterar su comodidad INTERRUPTOR DE PARED OPCIONAL Su ventilador tambi n est dise ado para funcionar con un interruptor de pared vendido por separado Consulte las instrucciones del interruptor de pared para su instalaci n y la informaci n de cableado MANTENIMIENTO IMPORTANTE ANTES DE INTENTAR HACER ALGUNA REPARACION ASEGURESE DE QUE LA ALIMENTACION ELECTRICA ESTE APAGADA EN LA CAJA DEL TABLERO DE ELECTRICIDAD CONSULTE LA SECCI N CABLEADO DE CONEXION Debido al movimiento natural del ventilador es probable que algunas conexiones se aflojen Verifique las conexiones de sost n los soportes y las sujeciones de las paletas dos veces al a o Aseg rese de que est n bien sujetas No es necesario retirar el ventilador del techo Limpie el ventilador de forma peri dica para que se mantenga como nuevo con el paso de los a os S lo utilice un cepillo suave o un trapo sin hilac
21. es de armado correspondientes La caja de distribuci n y su soporte deben soportar el peso total del ventilador en movimiento por lo menos 50 libras 22 kg No utilice cajas de distribuci n de pl stico Las figuras 1 y 2 son ejemplos de las distintas formas de instalar la caja de distribuci n Para colgar el ventilador donde haya un aparato de luz existente pero no haya una viga de techo necesitar instalar una barra de suspensi n como se muestra en la figura 3 P gina 10 FIGURA 1 CAJA DE DISTRIBUCI N FIGURA 2 CAJA DE DISTRIBUCI N FIGURA 3 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH INSTALACI N DEL VENTILADOR 1 Sujete el soporte de montaje a la caja de distribuci n con los dos tornillos y las arandelas suministrados con la caja de distribuci n Fig 4 Para un mejor rendimiento aseg rese de que el soporte de montaje est nivelado y firmemente sujeto al techo Probablemente deba agregar m s arandelas no incluidas entre la caja de distribuci n y el soporte de montaje para nivelarlo 2 Con cuidado eleve el conjunto del motor del ventilador sin las paletas e inserte la secci n T de la placa de la carcasa del motor en la ranura del soporte de montaje tal como se muestra en la fig 5 P gina 11 CAJA DE DISTRIBUCI N SOPORTE DE MONTAJE t te TORNILLOS FIGURA 4 Uot CAJA DE DISTRIBUCI N KA gt MOTOR DEL Ce VENTILADOR y SE N FIGURA 5 N U
22. hos para no rayar el acabado El recubrimiento est sellado con laca para minimizar la decoloraci n o el cambio de color No use agua para limpiarlo Esto podr a da ar el motor o la madera o producir una descarga el ctrica Puede aplicar una ligera capa de lustramuebles a las paletas de madera para protegerlas y aumentar su belleza Cubra los peque os rayones con una ligera aplicaci n de lustre para zapatos No hay necesidad de engrasar el ventilador El motor tienen cojinetes lubricados permanentemente P gina 14 gt e s SZ US FIGURA 12 ey Gee FIGURA 13 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH SOLUCI N DE PROBLEMAS El ventilador no se enciende J 2 Verifique los fusibles o los disyuntores Verifique las conexiones de los cables al ventilador y las conexiones del cable del interruptor en la carcasa de interruptores PRECAUCI N Aseg rese de que el interruptor principal de alimentaci n est apagado El ventilador hace mucho ruido 1 2 3 Aseg rese de que todos los tornillos de la carcasa del motor est n bien ajustados Aseg rese de que los tornillos que sujetan los soportes de las paletas al cubo del motor est n bien ajustados Aseg rese de que no haya fricci n entre las conexiones de las tuercas para alambres o con la pared interior de la carcasa de interruptores PRECAUCI N Aseg rese de que el interruptor principal de alimentaci n est apagado
23. ing fuses or turning off circuit breakers Secure the outlet box directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 50 Ibs Do not use plastic outlet boxes Figures 1 and 2 are examples of different ways to mount the outlet box To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 3 Page 2 OUTLET BOX FIGURE 1 OUTLET BOX FIGURE 2 OUTLET BOX FIGURE 3 N U O l e MODELS CFH52BS CFH52PB CFH52RB CFH52WH Page 3 INSTALL THE FAN 1 Attach the mounting bracket to the outlet box using the two screws and washers provided with the outlet box Fig 4 For best performance be sure the mounting bracket is level and secured firmly against the ceiling You may need to insert additional washers not provided between the outlet box and mounting bracket to make it level e Ld oo y 202297 5 ats ah 5 ogo og 0o o 0 po o o o o ors 0 Po K E OUTLET BOX 2 Carefully lift the fan motor assembly without the blades and insert the T section of the motor housing plate into the slot in the mounting bracket as shown in Fig 5 MOUNTING BRACKET t SCREWS FIGURE 4 FIGURE 5 N U O l e MODELS CFH52BS CFH52PB CFH52RB CFH52WH CONNECT WIRING Re
24. llation will not allow the fan to come into contact with any adjacent obstacles such as doors hanging lamps etc If you are installing more than one ceiling fan do not mix the blade sets Do not bend the blade brackets Do not operate reversing switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction Do not insert objects in between rotating fan blades Be careful when working around or cleaning the fan Please read specification label on product for further information and requirements WEIGHT OF FAN The weight of your fan is 15 2 Ibs The weights of light kits down rods and ceiling adapters are listed in the instructions packed with those accessories INSTALLER Leave this manual with the homeowner HOMEOWNER Use and care instructions on pages 6 amp 7 N U O l e MODELS CFH52BS CFH52PB CFH52RB CFH52WH CONTENTS Unpack your fan and check the contents You should have the following items A Blade set 5 B Mounting bracket A ara c C Fan motor assembly mnm D Motor housing 7 E Blade bracket set 5 E F Package hardware D Pull chain and fob Sey ud I TOOLS amp MATERIALS REQUIRED PHILLIPS BLADE SCREW SCREW LADDER CUTTER DRIVER DRIVER MOUNTING OPTIONS If there isn t an existing UL listed mounting box then read the following instructions Disconnect the power by remov
25. member to disconnect the power Follow the steps below to connect the fan to your household wiring Use the wire nuts supplied with your fan Secure the connectors with electrical tape Make sure there are no loose strands or connections IF INSTALLING OPTIONAL LIGHT KIT REFER TO INSTRUCTIONS INCLUDED WITH LIGHT KIT 1 Connect the fan supply black wire and light supply blue wire to the black household supply wire as shown in Figure 6 2 Connect the neutral fan white wire to the white neutral household wire 3 Connect the fan ground wire green to the household ground wire 4 Turn the connecting nuts upward and push the wiring into the outlet box 5 Attach the switch housing cover to the switch housing with the screws provided Figures 7 and 8 illustrate the wiring connections for optional wall control The wire color out of wall control may vary see wall control s installation manual for correct wire connections WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY ON AN OUTLET BOX OR SUPPORTING SYSTEM MARKED ACCEPTABLE FOR FAN SUPPORT OPTIONAL W Page 4 120 VAC LINE IN GREEN GROUND WIRING BOX GROUND TO MOUNTING BRACKET OR DOWNROD OPTIONAL LIGHT KIT style may vary FIGURE 6 120 VAC LINE IN ALL GREEN GROUND BLK CONTROL LA lt WIRING i BOX GROUND TO MOUNTING BRACKET OR DOWNROD
26. odically to help maintain its new appearance over the years Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly cause an electrical shock You can apply a light coat of furniture polish to the wood blades for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish There is no need to oil your fan The motor has permanently lubricated bearings TROUBLESHOOTING Fan will not start 1 Check circuit fuses or breakers 2 Check line wire connections to the fan and switch wire connections in the switch housing CAUTION Make sure main power is off Fan sounds noisy 1 Make sure all motor housing screws are snug 2 Make sure the screws that attach the fan blade bracket to the motor hub is tight 3 Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing CAUTION Make sure main power is off 4 Allow a 24 hour breaking in period Most noise associated with a new fan disappear during this time 5 If using an optional light kit make sure the screws securing the glassware are tight Check that the light bulb is also secure 6 Some fan motors are sensitive to signals from solid state variable speed controls If you have installed this type of control
27. omo una garant a expresa REMEDIO Durante el periodo de garant a limitada aplicable NuTone a su opci n suministrar piezas de repuesto o reparar o reemplazar sin cargo alguno cualquier ventilador o pieza hasta el grado en que NuTone lo encuentre cubierto bajo esta garant a limitada y en incumplimiento de la misma NuTone le enviar el ventilador reparado o reemplazado o las piezas de repuesto sin cargo Usted es responsable de todos los costos de retiro reinstalaci n y env o seguro u otros cargos de flete incurridos en el env o del ventilador o la pieza a NuTone Esta garant a no cubre a mantenimiento y servicio normal b uso y desgaste normal c ventiladores o piezas sujetos a mal uso abuso uso anormal negligencia accidente mantenimiento inadecuado o insuficiente almacenamiento o reparaci n que no sea reparaci n por parte de NuTone d da os causados por instalaci n defectuosa o bien instalaci n o uso contrario a las recomendaciones o instrucciones e cualquier ventilador que se haya movido de su punto de instalaci n original f da os ocasionados por el medio ambiente o los elementos naturales g da os en tr nsito h el acabado de cualquier parte met lica del ventilador o el accesorio i ventiladores en uso comercial o no residencial o j da os ocasionados por incendio inundaci n u otro caso fortuito Esta garant a cubre nicamente los ventiladores vendidos en Estados Unidos o a trav s de distri
28. r del ventilador o al limpiarlo 9 Lea la etiqueta de especificaciones del producto para obtener m s informaci n y requisitos PESO DEL VENTILADOR El peso de su ventilador es de 15 2 libras 6 89 kg Los pesos de los kits de iluminaci n las barras descendentes y los adaptadores de techo se encuentran en las instrucciones incluidas con dichos accesorios INSTALADOR Deje este manual con el propietario PROPIETARIO Instrucciones de utilizaci n y cuidados en la p ginas 14 y 15 N U O l e MODELOS CFH52BS CFH52PB CFH52RB CFH52WH CONTENIDO Desempaque su ventilador y verifique que el contenido est completo El paquete debe incluir lo siguiente A IATA B A Juego de paletas 5 A B Soporte de montaje sn c C Conjunto del motor SS del ventilador D Carcasa del motor EN E Juego de soportes de paletas 5 D 5 F Herrajes del paquete Cadenilla de tiro y dispositivo de ee seguridad HERRAMIENTAS Y MATERIALES REQUERIDOS NON AN DESTORNILLADOR DESTORNILLADOR ESCALERA ALICATE PARA PHILLIPS PLANO DE TIJERA CORTAR ALAMBRE OPCIONES DE MONTAJE Si no hay una caja de montaje homologada por UL entonces lea las siguientes instrucciones Desconecte la corriente el ctrica retirando los fusibles o apagando los disyuntores Asegure la caja de distribuci n directamente a la estructura de la edificaci n Utilice las abrazaderas y los material
29. ra su correcto ensamblaje 10 Despu s de terminar la instalaci n aseg rese de que todas las conexiones queden bien sujetas para evitar que el ventilador se caiga Aseg rese de que todas las conexiones de los cables est n firmemente sujetas y que no haya hilos conductores expuestos 11 No use agua ni detergentes al limpiar el ventilador y las paletas del ventilador Para la limpieza un trapo seco o ligeramente humedecido ser suficiente PRECAUCI N A PARA REDUCIR EL RIESGO DE LESIONES SIGALAS INDICACIONES QUE SE ENUMERAN A CONTINUACION 1 Para evitar da os a los cojinetes del motor e impulsores ruidosos y o desnivelados mantenga la unidad de alimentaci n el ctrica protegida del roc o de yeso el polvo de construcci n etc 2 El ventilador debe quedar instalado con un espacio m nimo de 7 pies 2 metros aproximadamente entre las paletas del ventilador y el piso 3 Al instalar el ventilador aseg rese de que no quede en contacto con otros obst culos adyacentes como puertas l mparas colgantes etc 4 Siva a instalar m s de un ventilador de techo no mezcle los juegos de paletas 5 No doble los soportes de las paletas 6 No haga funcionar el inversor mientras las paletas est n en movimiento Debe apagar el ventilador y las paletas deben quedar inm viles antes de invertir su direcci n 7 No inserte objetos entre las paletas del ventilador mientras est n rotando 8 Tenga cuidado al trabajar alrededo
30. vironmental or natural elements g damage in transit h finish on any metal portion of the fan or accessory i fans in commercial or nonresidential use or j damage caused by fire flood or other act of God This warranty covers only fans sold in the United States or through U S distributors authorized by NuTone EXCLUSION OF DAMAGES NUTONE S OBLIGATION TO PROVIDE REPLACEMENT PARTS OR REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND NUTONE S SOLE AND EXCLUSIVE OBLIGATION NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL INDIRECT CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE FAN ITS USE OR PERFORMANCE Incidental damages include but are not limited to such damages as loss of time and loss of use Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if the fan does not work properly Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties and is not transferable from the original consumer purchaser NUTONE SHALL NOT BE LIABLE TO YOU OR TO ANYONE CLAIMING UNDER YOU FOR ANY OTHER OBLIGATIONS OR LIABILITIES INCLUDING BUT NOT LIMITED TO

Download Pdf Manuals

image

Related Search

Related Contents

attention  ダウンロード  Lenovo W770 User's Manual  installation instructions for m503me stand alone micro module  PINTURA    TP-Link TL-WN321G User's Manual  

Copyright © All rights reserved.
Failed to retrieve file