Home
Monte Carlo 3CLYR52BSD Instructions / Assembly
Contents
1. q xs Mounting plate mM Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Use metal outlet box suitable for fan Support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting plate with the holes of the outlet box Reinstall the 2 outlet box screws securely Loosen 2 screws across from each other and remove the other 2 preassembled screws from mounting plate Corresponding to installation step 8 Save screws for later use Set dip switches on the Remote Tra
2. 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing CAUTION Make sure main power is turned off 3 If this fan uses manual forward reverse switch make sure the switch is pushed firmly either way Fan will not operate when switch is in the middle 4 If this fan uses remote controller make sure dip switches are setting properly and make sure battery is effective 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Check to be sure light bulb is tight in socket and not touching the glass shade 5 Some fan motors are sensitive to signals from Solid State variable speed controls 6 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 If this is a downrod mount fan make sure the ridge on mounting bracket engages the notch in the downrod ball 2 Make sure that canopy mounting bracket or mounting plate are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 3 Check that all blades are screwed firmly into blade holders
3. 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check blue wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulb and make sure bulb is tight in socket 5 Remove light kit and check the plug connections if they are present 6 If this fan uses remote controller make sure dip switches are setting properly and make Sure battery is effective CAUTION Make sure main power is turned
4. aligning the keyhole slots on the light plate with the preassembled screws on the plate Twist clockwise till lock Reinstall the screw removed in step 12 Tighten all screws securely Remove battery cover Install 12V battery into wall remote Duracell MN21 Evereday A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the battery cover in place 16 HAND HELD INSTALL 17 WALL MOUNT INSTALL Place battery cover over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and Snapping into place Install wall control unit to outlet box using machine screws provided Attach front cover to wall control unit with screws provided Snap battery cover in place 2013 Monte Carlo Fan Company 4 25 2013 Remote Control Transmitter Features MEDIUM SPEED FAN REVERSE Press once to change direction LED LIGHT of the fan Fan must be running to reverse LOW SPEED HIGH SPEED LIGHT ON OFF SETTING 5 AND DIMMER Press and FAN OFF SETTING 5 hold to dim light infinitely Turn fan off only FAN SPEED Depress 1 dot for low speed 2 dots for medium or 3 dots for high To turn fan off press square LIGHT DIMMER To turn light on press light dimmer once quickly To turn off press once quickly while light is on To dim light hold down
5. button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress reverse button with fan running Allow a few seconds for fan to slow down and change rotation direction Clicking noise may be heard after depressing button Note If not using for long periods of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity O 2013 Monte Carlo Fan Company 4 25 2013 Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work Suggested Remedy
6. from house to White from remote mounting plate and twist clockwise till screws from side of mounting plate receiver marked AC N Black from house lock Reinstall the screws removed in corresponding to installation step 10 to Black from remote marked AC L Step 4 Tighten all screws securely Save screws for later use Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wire connector Attach housing onto mounting plate Install blade with screws provided Loosen 2 and remove 1 preassembled aligning the keyhole slots on the housing aligning each of the holes as shown and screw from the plate on motor Save with the screws on mounting plate and tighten all screws securely Repeat this screw for later use twist clockwise till tight Reinstall the process for remaining blades screw removed in step 9 Tighten all screws securely 2013 Monte Carlo Fan Company 4 25 2013 13 14 Blue lt ___4 it LED ts Battery cover Battery sp Connect white wire from fan to white wire from LED light kit and then connect blue wire from fan to black wire from LED light kit Attach LED light kit to light pan by locating dimples tn light pan with grooves on the LED light kit and twist clockwise until tight Attach light pan onto the plate on motor
7. MONTE CARLO CEILING FAN COMPANY Owner s Guide and Installation Manual MONTE CARLO N 3CLYR52 42XXD Series Fan UL Model NO MC1213 52 MC1213 42 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE RETAILER NAME MODEL NUMBER RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 3CLYR52XXD 7 7 kgs 16 94 lbs c US 3CLYR42XXD 6 7 kgs 14 74 lbs LISTED Total fan weight with light kit Cautions and Warnings WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box WARNING Before you begin installing the fan servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent pow
8. er from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade WARNING To Reduce The Risk Of Fire Electric Shock or Personal Injury Mount To Outlet Box Marked Acceptable for Fan Support of 15 9 kg 35 Ibs or less And Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be insta
9. lled with an isolating wall control switch WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control part no O83R manufactured by Rhine Electronic Co Ltd WARNING To reduce the risk of fire or electric shock do not use this fan with any other solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application Never place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities CAUTION To Reduce the Risk of Electric Shock Disconnect the electrical supply circuit to the fan before installing the light kit All set screws must be checked and tightened where necessary before installation Tools Required for Assembly not included Electrical Tape Phillips Screwdriver Pliers Safety Glasses Stepladder and Wire Strippers Customer Service 800 969 3347 Customer Service Center 7400 Linder Ave Skokie IL 60077 www montecarlofans com 2013 Monte Carlo Fan Company 4 25 2013
10. nsmitter and Remote Receiver to the same settings This must be done so the units will communicate properly If you have other fans you can set to control from one Transmitter by setting receivers the same as the Transmitter If you have more than one fan with remote you can set the dip switches to different positions to have separate control Note Remote receiver is located on the top plate of motor assembly as shown in the graphic of installation step 7 O 2013 Monte Carlo Fan Company Hang motor assembly onto the hook on mounting plate for hands free wiring and safety cable installation For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the Safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box 4 25 2013 7 8 Power Ground Green source Wall switch Driver Make wiring connections using wire Lift motor assembly aligning the keyhole Loosen 2 screws across from each other connectors provided as indicated above slots with the preassembled screws on and remove the other 2 preassembled White
11. off before entering switch housing and or canopy 2013 Monte Carlo Fan Company 4 25 2013 Apr 2013