Casablanca 59065 Instructions / Assembly
Contents
1. Table of Contents www CasablancaFanCo com 1 888 227 2178 What to Expect with Congratulations on purchasing your new Your Installation Tools Needed Mounting Options Ceiling Bracket Casablanca ceiling fan It will provide gee comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating fan z your fan 5 We are proud of our work and appreciate the opportunity to supply you with the oe best ceiling fan available anywhere in the Wall Control world To register your fan please visit www CasablancaFanCo com register Save your receipt for proof of purchase Blades M8502 01 06 13 14 Casablanca Fan Company What to Expect with Your Installation Must be able to secure the fan to building structure or fan rated outlet box You may need a friend to help you Check box to see fan weight If you are unfamiliar with wiring use a qualified electrician D Know your wiring i Ceiling angles greater than 34 will require an Angled Mounting Kit See page 4 for details a Assess ceiling angle 30 inches from blade tip to nearest wall or obstruction 7 feet from bottom edge of blade to the floor A Assess location Standard Downrod for ceilings 8 10 feet h
2. 3 minutes of restoring power to the fan press both the Fan Off button and the 4 button for at least four seconds Your fan will turn on at the lowest speed to indicate successful syncing If it does not turn off power to your fan wait one minute then try again If using the transmitter with multiple fans repeat this process for each fan Operation continued Lights Down Reverse Battery Holder Quickly press the up or down arrow to turn the lights off and on Hold the up or down arrow to raise or dim the light level The reverse button changes the direction that the blades turn The power button turns the fan off and on Reverse Button The reverse button on the wall control changes the air flow pattern In warm weather use a downward air flow pattern In cold weather use b upward air flow pattern M8502 01 06 13 14 Casablanca Fan Company www CasablaneaFanEo com 1 888 227 2178 The Safe Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out To use Safe Exit e Press the fan power button off for at least three seconds to initiate the Safe Exit Mode The lights will flash for visual confirmation e The lights will stay on 50 brightness for 20 seconds and then begin to dim After a total of 30 seconds the lights will be completely off Note For CFL lighting the lights will stay on 100 brightness for
3. are attached M8502 01 MR 06 13 14 Casablanca Fan Company Light Kit www CasablancaFanCo com 1 888 227 2178 Install a halogen bulb in each socket When Position the indentations in the outer rim of necessary replace with bulbs of the same the globe so they line up with the tabs on type and wattage the inside of the fan light kit Carefully lift the globe up inside the light kit as far as it will go See next page for fan then rotate the globe clockwise until it is held operation instructions tightly in place by the four tabs M8502 01 06 13 14 Casablanca Fan Company Operation Battery Holder Battery Door Before operating the wall control press on the battery door to eject it Unscrew the battery holder Insert the battery found in the control hardware bag with the positive side facing downward Reinstall the battery holder and reinsert the battery door into the wall control If you are installing multiple remote controlled fans on the same circuit breaker you may need to perform a few extra steps to prevent interference or faulty operation of your remote controls Go to www CasablancaFanCo com FAQs and click How do I properly install multiple remote controlled fans for more information M8502 01 06 13 14 Casablanca Fan Company www CasablancaFanCo com 1 888 227 2178 Note The remote must be paired before the fan will operate Within
4. 30 seconds After a total of 30 seconds the lights will be completely off Maintenance amp Cleaning www CasablancaFanCo com 1 888 227 2178 Be sure to turn off power to the fan before performing any maintenance or relamping Changing the bulbs carefully rotate the globe Cleaning the fan use soft brushes or cloths counterclockwise until it comes loose from the to prevent scratching Cleaning products may tab and lower it from inside the light kit Unscrew damage the finishes the bulbs and replace them with bulbs of the same type and wattage Reinstall the globe M8502 01 06 13 14 Casablanca Fan Company Troubleshooting www CasablancaFanCo com EZA Fan doesn t work Excessive wobbling Noisy Operation Lights dim when turned on or Press a fan speed button 1 4 e Tighten all blade screws until e Tighten the blade screws until do not turn on at all they are snug they are snug e Make sure the wattage of the light bulbs installed matches the specifications on the light sockets see page 17 for instructions on changing the properly seated bulbs Check the circuit breaker to ensure the power is turned on e Turn the power off support e Check to see if any of the the fan carefully and check blades are cracked If so replace Check the wall control battery that the hanger ball is all of the blades Make sure that you have paired the wall control Use the provided balancing kit and i
5. Standard Downrod for ceilings 8 10 high Longer Downrod for angled ceilings or ceilings 10 or higher pre assembled O J O U S Sold Separately www CasablancaFanCo com 1 888 227 2178 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe M8502 01 06 13 14 Casablanca Fan Company Downrod continued www CasablancaFanCo com 1 888 227 2178 T U WY O O Remove the pre installed setscrew so that the downrod can be inserted Slide the adapter cover onto The wires can be cut but the downrod then hand leave at least 8 extending tighten the downrod at least from the top of the 4 5 full turns until it stops downrod Tighten the setscrew with pliers DO NOT HAND TIGHTEN If the setscrew is not tightened securely the fan may fall M8502 01 06 13 14 Casablanca Fan Company Downrod continued www CasablancaFanCo com EZA Lower the adapter cover Put the wires and downrod DO NOT PICK THE FAN UP BY until it rests flush against the through the canopy Let the THE CANOPY OR WIRES Place motor housing canopy sit loosely on top of the downrod ball into the slot the fan in the ceiling bracket M8502 01 06 13 14 Casablanca Fan Company C p l www CasablancaFanCo com 1 888 227 2178 Note To connect th
6. e undesired operation l e If you are using a outlet box for wall control installation the wires coming from the wall control must be grounded using the attached green wire If not placed in an outlet box cap the green wire coming from the wall control with an included wire nut l ho M8502 01 06 13 14 Casablanca Fan Company www CasablancaFanCo com 1 888 227 2178 Position the canopy so that when Lift the canopy into place so that Insert the two canopy screws lifted into place the canopy fits into the screw holes are aligned found in the hardware bag the hanging bracket as shown M8502 01 06 13 14 Casablanca Fan Company Blades To install each blade first insert the blade into the blade slot on the side of the fan the screw holes inside the fan Your blades are shielded with Dust Armor which is ananotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes 12 M8502 01 06 13 14 Casablanca Fan Company www CasablancaFanCo com 1 888 227 2178 Insert the blade screws found in the A hardware bag into the blade washers then the blade grommets both found in the W hardware bag Blades continued www CasablancaFanCo com 1 888 227 2178 Install the blade screws washers and grommets so the grommets fit snugly into the blade screw holes Securely tighten after all three screws
7. e wires green yellow stripe Using an orange wire connector from the W hardware bag connect the 3 grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and hanging bracket Buipuno16 d 1 S MOJ u 16 Q Q D D 5 SJ lt n an D D hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the blue wire connectors from the remote control hardware bag connect the white wire from the receiver marked common out to the white wire from fan Connect the black wire from the receiver marked fan out to the black wire from the fan Connect the blue wire from the receiver marked light out to the blue wire from the fan The red wire from the receiver will not be used it has a pre installed wire terminator JNO UOWWOD d I4YM Using an orange wire connector from the W hardware bag connect the black wire ungrounded from the ceiling to the black wire from the receiver marked live in Connect the white wire grounded from the ceiling to the white wire from the receiver marked neutral in or common in papunosb y ym Ul pea nau SYM 4 R AOM RECEN Turn the splices upward and push them carefully back through the hanger bracket into the outlet box Spread the wires apart with the grounded wires on one s
8. ide of Refer to CAUTION c 1 on pg 2 the outlet box and the ungrounded wires on the other side of the outlet box M8502 01 06 13 14 Casablanca Fan Company Wall Control www CasablancaFanCo com 1 888 227 2178 D Drill Holes lt o Drywall Anchors Painter s Tape Template 1 Tape the provided wall control 1 Using a 9 64 drill bit drill a hole 1 Using a drywall punch saw 1 Insert the wall control into the template with painter s tape at in each screw cut out on the wall i cut out the interior shape of R dry wall cut out 2 the desired installation area control template the template using one of Align the screw holes in the wall control with the drywall anchors 2 Drill holes inside the four 2 Using a hammer tap a drywall the four drilled corners as a corners of the template anchor found in the wall control starting point 3 D eae plate E Note Make sure the wall hardware bag into each hole 2 Remove the template and the a ae a are control template is level before until the drywall anchor is flush cut out section of drywall SOTA a S ernie proceeding to the next step with the wall hardware bag through the wall control and into the drywall anchors This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may caus
9. igh 2 Longer Downrod for ceilings 10 feet or higher LA Select a downrod length 2 M8502 01 06 13 14 Casablanca Fan Company www CasablancaFanCo com 1 888 227 2178 Read and Save These Instructions This product conforms to UL Standard 507 A WARNINGS w 1 To reduce the risk of fire electrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 70 Ibs 31 8 kg and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Casablanca Solid State Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades CAUTIONS c 1 All wiring must be in accordance with national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Casablanca replacement parts This equipment has been tested and fo
10. ngled 2 required also need an Angled Mounting Kit sold separately Mounting N Outlet Box required Mounting Use the three steps below to determine if your ceiling angle is greater than 34 Use Standard Mounting Use Angled Mounting to hang the fan to hang the fan from a from a flat ceiling vaulted or angled ceiling Guide Touches BOTH Ceiling amp Wall You need ONLY a Longer Downrod most common Mounting Kit M8502 01 06 13 14 Casablanca Fan Company Ceiling Bracket www CasablancaFanCo com 1 888 227 2178 For angled ceilings point opening toward peak Use wood screws Use machine screws included when securing provided with outlet to support structure with box when securing to approved electrical outlet existing ceiling fan rated box Drill 9 64 pilot holes outlet box Make sure in support structure to aid it is securely installed in securing ceiling bracket and is acceptable for fan with hardware foundin support of 31 8 kg 70 Ibs the hardware bag or less Make sure all four bumpers are If you are unable to do this still attached call Technical Support at To avoid possible electrical shock before 1 888 227 2178 installing your fan disconnect the power by Refer to warning w 1 on pg 2 turning oi ine aai breakers to the outlet box associated with the wall switch location e M8502 01 06 13 14 Casablanca Fan Company Downrod
11. nstructions to balance Make sure the blades spin freely term Turn off power from the circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 9 e Install a fresh battery in the wall control Remote doesn t work If you have multiple remotes or multiple remote controlled fans AUTHORIZED SERVICE installed on the same circuit CENTERS breaker and you are experiencing For the most updated list of e Make sure you have paired the interference or faulty operation of Casablanca Authorized Service remote your remote controls please go to Centers visit www CasablancaFanCo com FAQs www CasablancaFanCo com or and click How do properly install call toll free 1 888 227 2178 multiple remote controlled fans for information on how to correct this issue M8502 01 06 13 14 Casablanca Fan Company
12. und to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Tools Needed www CasablancaFanCo com 1 888 227 2178 a amp L Ladder LI Pliers a Wire Strippers lf Screwdrivers If you are installing multiple remote controlled fans on the same circuit breaker you may need to perform a few extra steps to prevent interference or faulty operation of your remote controls Go to www CasablancaFanco com FAQs and click How do properly install multiple remote controlled fans for more information Power Drill 9 64 Drill Bit optional optional If mounting to a support structure you will also need these tools M8502 01 06 13 14 Casablanca Fan Company VO Mounting Options 1 888 227 2178 R A l O i egoe U p If you have a flat ceiling Hang your fan by a standard downrod included Standard Support Support Mounting Structure Tae O If you have an angled ceiling SAN D 1 You will need a longer downrod sold separately Outlet Box 2 If your ceiling angle is greater than 34 you will A