1. USE AND CARE GUIDE HOLLANDALE 52 INCH CEILING FAN Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 800 527 0998 HAMPTONBAY COM l Intertek THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Table of Contents Table Of Contents ccccccceseesesesesesesseeenesesesssssssssenseenenenes 2 Safety Information 2 ccceceeeeeesesseeeeeeeeeeeeeeeeeeensenneens 2 WANT AIMY seeccsiet cine feed spec states Gees np ecenan iad daaa daa aaaeaii 3 Pre inStallationy sisiccccsissscscscscccscecsscctccccsesssnasscdstsaececcessees 3 SDOCITICATIONS isisisi riranin tinna 3 Tools Required s sessssssesssssssnnnsnsusunensnsnsnnnsnnnonsnnanannnennnnnnnnnnn 3 Hardware included nsitanstimninananan 4 Package Contents ssssssssssssssrsrssnnssnnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 5 DS tallati OM seis scsi ccsctiencicccccsticasndessiadsanstusteatecscssicdesctsscacsass 6 Assembly ses cnc ssw amannan 7 Hanging the ReaMicessscesscfasecssste sates cecedersdacedesedstecesecassuenatetatntess 7 Attaching the Fan Blades uu 10 installing the Light Kit weccscccsciersseucveserset
2. for the wall control for the correct color and wire connections electricity is turned off at the circuit breaker or main fuse box i WARNING To avoid possible electrical shock be sure before wiring QQ Fan wall control RR Light wall control WARNING Check to see that all connections are tight SS Fan wall control output wire AN including ground and that no bare wire is visible at the wire TT Light wall control output wire nuts except for the ground wire Follow the steps below to connect the fan to your house supply wires Secure the wire nuts EE supplied with your fan by wrapping the connections with electrical tape Connect the black Il and blue JJ color wires from the fan to the hot wire black KK from ceiling Connect the white LL color wire from the fan to the neutral wire white MM from ceiling If there is a ground wire NN green color or bare copper color in your outlet box connect the green wire 00 from the fan to it If there is not a ground wire in your outlet box connect the green wire 00 from the fan to the green wire PP from the mounting bracket C Secure the wire connection with the plastic wire nuts EE Assembly Hanging the Fan continued 4 Attaching the fan motor assembly to the mounting plate After completing the electrical connections align the four screw holes between the mounting brack
3. up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box All setscrews must be checked and retightened where necessary before installation not use this fan with any solid state fan speed control device WARNING To reduce the risk of electrical shock or fire do It will permanently damage the electronic circuitry WARNING To reduce the risk of personal injury do not bend the blade arms also referred to as flanges when installing the brackets balancing the blades or cleaning the fan WARNING Do not insert foreign objects between rotating fan blades WARNING To reduce the risk of fire electric shock or personal injury mount the fan to the outlet box marked acceptable for fan support with the screws provided with the outlet box CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box Warranty We warrant the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser We also warrant that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a
4. e Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 800 527 0998 HAMPTONBAY COM Retain this manual for future use RM262 000001 HD
5. eecranctevecer stevens 11 Operati mM oo incicccdicecscachis ce nseccceceesteetannadecedecennens edeeeesazane 13 Care and Cleaning ccccccecssesseseeeneeeeeeeeeeeeeeseneeneees 13 Troubleshooting ii nsaccssncsececcisaansaansnneceencndescdvenndudbenuacadaue 14 Service Parts wisisitcccccssctesccssciececssstnecsearseneccscecsenicccanss 15 Safety Information Read and save these instructions To reduce the risk of electric shock ensure electricity has been turned off at the circuit breaker or fuse box before beginning All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 Ibs Use only UL Listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 ft clearance from the trailing edge of the blades to the floor To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning After making electrical connections spliced conductors should be turned upward and pushed carefully
6. et I and the mounting plate C Insert the mounting plate screws DD through the mounting bracket I and into the mounting plate C Tighten all screws securely 5 Finishing the fan installation Remove the two screws UU and loosen the two screws VV on the mounting plate C Install the fan housing E to the mounting plate C by aligning the key holes in the fan housing E with the two screws VV in the mounting plate C then lifting the fan housing E up and turning clockwise Re tighten the two screws VV and re install the two screws UU Tighten all screws securely HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Assembly Attaching the Fan Blades 6 Fastening the blade to the 7 Fastening the blade blade bracket assemblies to the motor Attach the fan blades A to the blade brackets B by Tighten the blade assemblies J onto the bottom of the using three blade screws AA and fiber washers BB motor by using the blade bracket screws CC Tighten screws AA and fiber washers BB securely Qab BB Oa CC 8 Attaching the light kit plate to the mounting ring Remove one of three mounting ring screws WW and loosen other two screws on the mounting ring K Place the key holes on the light kit plate F over the two mounting ring screws WW previously loosened from t
7. he mounting ring K and turn the light kit plate F until it locks in place at the narrow section of the key holes Secure the light kit plate F by tightening the two screws WW previously loosened and replacing the one previously removed Assembly Installing the Light Kit 9 Attaching the light kit to the light kit plate Remove the three screws XX on light kit plate F While holding the light kit assembly G under your fan firmly snap the wire connection plugs YY together Carefully push all wires back into the light kit G then install the light kit assembly G onto the light kit plate F with the three screws XX previously removed Be sure to tighten all screws securely XX lt lt 11 HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Assembly Installing the Light Kit continued 1 0 Installing the glass shades and bulbs To install the light kit glass shades H remove the socket rings ZZ on the light kit G and install the glass shades H to the light kit G Secure by tightening the socket rings ZZ previously removed Install the four 40W candelabra bulbs HH included Attach the pull chain fob FF to the chain on the light kit G Restore power and your light kit is ready for operations HH Operation Turn on the power and check the operation of your fan There are two p
8. he wood blades Optional Cover small scratches with a light application of shoe polish Do not Do not use water when cleaning Water could damage the motor or the wood or possibly cause an electrical shock Do not apply oil to your fan or motor The motor has permanently lubricated sealed ball bearings HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Troubleshooting WARNING Ensure the power is off at the electrical AN panel box before you attempt any repairs Refer to the section Making the Electrical Connections on page 8 Problem Solution Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing The fan will not start Check to ensure the dip switches from the remote control and receiver are set to the same frequency Ensure all motor housing screws are snug Ensure the screws that attach the fan blade arm to the motor hub are tight Ensure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time The fan sounds noisy If using the ceiling light kit ensure the screws securing the glassware are tight Check that the ligh
9. of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer Contact the Customer Service Team at 1 800 527 0998 or visit www hamptonbay com Pre Installation SPECIFICATIONS Fan size Speed Volts Amps Watts RPM CFM N W G W C F Low 0 25 14 8 79 2195 ee R 52in Medium 120 0 37 32 6 121 30 7 05 x oe 1 627 ft High 0 48 57 8 156 4491 NOTE These are approximate measures They do not include amps and wattage used by the light kit TOOLS REQUIRED Phillips Flat blade Step Wire Electrical i screwdriver x screwdriver ladder stripper Tape HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Pre Installation continued HARDWARE INCLUDED NOTE Hardware shown to actual size unless noted otherwise in the table below _ o e CO BB CC FF HH DD Part Description Quantity AA Blade screw 3 16 x8mm 16 BB Fiber washer not to scale 16 cc Blade b
10. period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident misuse improper installa tion or by affixing any accessories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty We hereby disclaim any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you The retailer shall not be liable for incidental consequential or special damages arising out
11. racket screw 1 4 x12 7mm 11 DD Mounting plate screw 1 4 x12 7mm 4 EE Plastic wire nut 3 FF Pull chain fob 2 GG Balancing kit not to scale 1 HH 40W candelabra bulb not to scale 4 Pre Installation continued PACKAGE CONTENTS A E F H B G Part Description Quantity Part Description Quantity A Blade 5 E Fan housing 1 B Blade bracket 5 F Light kit plate 1 C Mounting plate 1 G Light kit Socket ring preassembled 1 D Fan motor assembly 1 H Glass shade 4 HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Installation MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount the fan to an outlet box marked acceptable for fan support using the screws provided with the AN outlet box An outlet box commonly used for the support of lighting fixtures may not be acceptable for fan support and may need to be replaced If in doubt consult a qualified electrician If your ceiling fan does not have an existing UL listed mounting box then install one using the following instructions Disconnect the power by removing the fuses or turning off the circuit breakers Secure the outlet box 1 not included directly to the building structure Use appropriate fasteners and materials not included The outlet box and its bracing must be able to full
12. t bulb is also secure Ensure there is a short distance from the ceiling to the canopy It should not touch the ceiling Ensure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a The fan wobbles point on the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Measurements deviation should be within 1 8 in Run the fan for 10 minutes Use the enclosed blade balancing kit if the blade wobble is still noticeable 14 Service Parts F G H DD HH Part Description Part Description A Blade AA Blade screw 3 16 x8mm B Blade bracket BB Fiber washer C Mounting plate CC Blade bracket screw 1 4 x12 7mm D Fan motor assembly DD Mounting plate screw 1 4 x12 7mm E Fan housing EE Plastic wire nut F Light kit plate FF Pull chain fob G Light kit Socket ring preassemblde GG Balancing kit H Glass shade HH 40W candelabra bulb 15 HAMPTONBAY COM Please contact 1 800 527 0998 for further assistanc
13. ull chains used to operate your fan The 3 speed pull chain controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low and 4 pulls Off The light kit pull chain turns the light kit ON or OFF The reverse switch is located on the surface of the switch housing This switch controls directions forward switch left or reverse switch right NOTE Wait for the fan to stop before reversing the direction of the blade rotation Warm weather Counterclockwise Direction A downward air flow creates a cooling effect This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Clockwise Direction An upward air flow moves warm air off the ceiling This allows you to set your heating unit on a lower setting without affecting your comfort L le DAD IK Ae ae N Ta C C Care and Cleaning Do Check the support connections brackets and blade attachments twice a year Make sure they are secure Because of the fan s natural movement some connections may become loose over time It is not necessary to remove the fan from the ceiling Clean your fan periodically Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Optional Apply a light coat of furniture polish to t
14. y support the weight of the moving fan at least 35 Ibs Do not use a plastic outlet box The illustrations below show two different ways to mount the outlet box 1 not included Was 1 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar 2 not included as shown above Assembly Hanging the Fan Attaching the mounting plate to Hanging the fan motor assembly the electrical box from the mounting plate WARNING To reduce the risk of fire electric shock or Align the slot hole in the fan motor assembly mounting other personal injury mount the fan only to an outlet box or bracket to the J hook on the mounting plate C supponiig sea mansa CRE OBLIGE rorjranjsuppornana Lift the mounting bracket I onto the J hook making sure use thie mounting acre provided wiibitie ules BOX the slot hole is seated properly on the J hook and allow it to hang freely Attach the mounting plate C to the outlet box with two screws and washers provided with the outlet box Make sure the mounting plate C is tight and secured HAMPTONBAY COM Please contact 1 800 527 0998 for further assistance Assembly Hanging the Fan continued Making the electrical connections If you wish to install an optional wall control use this diagram as a guide but refer to the installation manual