Hampton Bay 24816-021 Instructions / Assembly

image

Contents

1. Decorative nut HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM Retain this manual for future use EURO6000001 Y
2. balancing the blades G i WARNING To reduce the risk of personal injury do not or cleaning the fan WARNING Do not insert foreign objects between rotating fan blades G Insert the blade G through the slot in the housing Align the holes in the blade G and the fan motor assembly F and secure with a blade attachment screw and fiber washer CC Repeat this procedure with the remaining blades G 13 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Installing the Light Kit 1 Attaching the light kit mounting plate to the mounting ring Remove one of the three mounting plate screws JJ from the mounting ring SS and loosen the other two screws Do not remove Place the key holes in the light kit mounting plate H over the two screws JJ previously loosened from the mounting ring SS Turn the light kit mounting plate H until it locks in place at the narrow section of the key holes Secure by tightening the two mounting plate screws JJ previously loosened and the one JJ previously removed 14 Attaching the light kit to the mounting plate Remove one of the three light kit mounting screws KK from the mounting plate H and loosen the other two screws KK Do not remove While holding the light kit I under your fan F snap together the wire connectio
3. above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Rotate the fan until the next blade is positioned for measurement Repeat for each blade Measurements deviation should be within 1 8 in Run the fan for 10 minutes Use the enclosed blade balancing kit if the blade wobble is still noticeable 18 Service Parts eg 5 E Description Mounting bracket preassembled Canopy Canopy bottom cover Hanger ball downrod assembly Coupling cover Fan motor assembly Blades Mounting plate Light kit Glass shade Glass frame Receiver Remote control o z zrixc ci jmrmieimimjocoj o 12V MN21 A23 battery Remote control holder 19 DD O FF GG m B HH 3 li JJ fh AA B KK gp FEN LL CC i V g Part Description P 40 Watt candelabra bulb AA Plastic wire nut BB Mounting bracket screw preassembled CC Blade attachment screw and fiber washer Balance kit EE Remote control holder mounting screw FF Remote control holder plug preassembled GG Clevis pin preassembled HH Cotter pin preassembled Collar setscrew preassembled JJ Mounting plate screw preassembled KK Light kit mounting screw preassembled LL Metal nut preassembled to the light kit MM
4. and hold the button to set the desired brightness The light button has an auto resume it will stay at the same brightness as the last time it was turned off INSTALLING THE REMOTE CONTROL HOLDER Remove the two remote control holder plugs FF from the remote control holder 0 Note that the plugs have unique tabs that allow them to fit only in one hole Attach the remote control holder 0 with the two remote control holder mounting screws EE Replace the two remote control holder plugs FF each into its own hole 16 Operation continued REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the light kit Slide the switch to the left for warm weather operation Slide the switch to the right for cool weather operation NOTE Wait for the fan to stop before reversing the direction of the blade rotation Warm weather Counterclockwise Direction A downward air flow creates a cooling effect This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Clockwise Direction An upward air flow moves warm air off the ceiling This allows you to set your heating unit on a cooler setting without affecting your comfort oe Se Ne Care and Cleaning Do Check the support connections brackets and blade attachments twice a year Make sure they are secure Because of the
5. Item 597 730 Model 24816 021 USE AND CARE GUIDE SENZE 52 INCH CEILING FAN ASSEMBLY Questions problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 6 p m EST Monday Friday 1 877 527 0313 HAMPTONBAY COM THANK YOU We appreciate the trust and confidence you have placed in Hampton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay Assembly Assembling the Fan Body 1 Preparing the canopy Remove the canopy bottom cover C from the canopy B by turning the canopy bottom cover C counter clockwise Remove the mounting bracket A from the canopy B by removing the non slotted mounting bracket screw BB from the bottom of the canopy B and loosening the slotted mounting bracket screw BB a half turn from the screw head Next turn the canopy B counterclockwise to remove the mounting bracket A from the canopy B A BB eS ML N BB Assembling the fan WARNING Failure to properly install the cotter pin HH could result in the fan loosening and possibly falling NOTE If a longer downrod not included is needed take out the screw located in the hanger ball lower the hanger ball an
6. an only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of AN the hanger ball downrod assembly D Failure to properly seat the tab in the groove could cause damage to the wiring Pass the 120 volt supply wires through the center hole in the mounting bracket A Attach the mounting bracket A to the outlet box NN with the screws and washers provided with your outlet box NN Securely tighten the two mounting screws Carefully lift the fan motor assembly F up to the mounting bracket A and seat the hanger ball downrod assembly D in the mounting bracket A socket Make sure the tab on the mounting bracket A socket is properly seated in the groove in the hanger ball downrod assembly D This will help to balance the ceiling fan HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Assembly Preparing the Remote Control Preparing the receiver and remote control WARNING To avoid possible electrical shock ensure electricity is turned off at the main fuse box before connecting the wiring CAUTION The frequency switches on the receiving unit are covered with a rubber cover Remove the rubber cover and then replace it after making any changes to the frequency switches CAUTION Do n
7. d remove the pin Remove all three pieces from the downrod and assemble them onto the new longer downrod before proceeding to the downrod installation Route the wires exiting from the top of the fan motor assembly F through the coupling cover E and the canopy bottom cover C Ensure the slot openings are on top Route the wires through the canopy B and then through the hanger ball downrod assembly D Align the holes at the bottom of the hanger ball downrod assembly D with the holes in the collar on top of the fan motor assembly F Carefully insert the clevis pin GG through the holes in the collar and the hanger ball downrod assembly D Be careful not to jam the clevis pin GG against the wiring inside the hanger ball downrod assembly D 2 Preparing the motor Remove the clevis pin GG and cotter pin HH and loosen the two collar setscrews Il from the fan motor assembly F collar Insert the cotter pin HH through the hole near the end of the clevis pin GG until it snaps into the locked position Firmly tighten the two collar setscrews Il on top of the fan motor assembly F Assembly Hanging the Fan Attaching the mounting bracket to the electrical box Hanging the fan from the mounting bracket A WARNING To reduce the risk of fire electric shock or other personal injury mount the f
8. fan s natural movement some connections may become loose over time It is not necessary to remove the fan from the ceiling Clean your fan periodically Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Optional Apply a light coat of furniture polish to the wood blades Optional Cover small scratches with a light application of shoe polish Do not Use water when cleaning Water could damage the motor or the wood or possibly cause an electrical shock Apply oil to your fan or motor The motor has permanently lubricated sealed ball bearings HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Troubleshooting box before you attempt any repairs Refer to step 8 Making WARNING Ensure the power is off at the electrical panel the Electrical Connections on page 11 Problem Solution The fan will not start Check the main and branch circuit fuses or breakers Check the line wire connections to the fan and switch wire connections in the switch housing Check to make sure the dip switches from the remote control and receiver are set to the same frequency The fan sounds noisy Make sure all motor housing screws are snug Make sure the screws that attach the
9. fan blade arm to the motor hub are tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If using the ceiling light kit make sure the metal nut securing the glassware is tight Check that the light bulb is also secure Make sure there is a short distance from the ceiling to the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between the mounting bracket and outlet box The lights turn off and will not come back on This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power off and relamp keeping the wattage under 190 watts Restore power to your ceiling fan and continue normal operation The remote control is not working Do not connect the fan with wall mounted variable speed control s Check to make sure the dip switches from the remote control and receiver are set to the same frequency The fan wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling
10. n plugs TT Place the key holes in the light kit I over the two mounting screws KK previously loosened from the mounting plate H Turn the light kit I until it locks in place at the narrow section of the key holes Secure by tightening the two light kit mounting screws KK previously loosened and the one KK previously removed Assembly Installing the Light Kit continued 1 3 Installing the glass shade Remove the decorative nut MM from the light kit I Install the three 40 watt candelabra bulbs P included Place the glass shade J over the light kit I stem Secure the glass shade J with the metal nut LL rubber side on the top Do not overtighten Place the glass frame K onto the light kit I stem Secure the glass frame K with the decorative nut MM 15 HAMPTONBAY COM Please contact 1 877 527 0313 for further assistance Operation REMOTE CONTROL OPERATING INSTRUCTIONS Install a 12V MN21 A23 battery N included into the remote control M To prevent damage to the remote control M remove the battery if not used for long periods Restore power to the ceiling fan and test for proper operation HI MED LOW buttons set the fan speed OFF button turns the fan off AF button turns the light ON or OFF and also controls the brightness setting Press and release the button to turn the light ON or OFF Press
11. ot use with a wall light dimmer switch If you feel you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician This remote control unit is equipped with 16 code combinations to prevent possible interference from or to other remote units The frequency switches on your receiver L and remote control M have been preset at the factory Please recheck to make sure the switches on the remote control M and the receiver L are set to the same position Any combination of settings will operate the fan as long as the switches in the remote control M and receiver L are set to the same position After checking the switches insert the receiver L into the mounting bracket A with the flat side of the receiver L facing the ceiling 10 Assembly Making Electrical Connections T Making the electrical connections including the ground and that no bare wire is visible at the i WARNING Check to see that all connections are tight wire nuts except for the ground wire CAUTION Do not use with a wall light dimmer switch 20 feet from the remote control for proper signal transmission NOTE The fan must be installed at a maximum distance of A between the remote control and the fan s receiving unit Follow the steps below to connect the fan to your household wiring Use the plastic wire nuts AA with your fan Secure the wire nut
12. r assistance Assembly Completing the Fan Body 8 Installing the canopy A WARNING Make sure the tab on the mounting bracket A properly sits in the groove in the hanger ball downrod assembly D before attaching the canopy B to the mounting bracket A by turning the canopy housing until it drops into place Attaching the canopy bottom cover Attach the canopy bottom cover C to the mounting bracket screw BB heads on the bottom of the canopy B by inserting the screw heads into the key slots in the canopy bottom cover C and rotating the canopy bottom cover C clockwise Make sure connections are neatly tucked in the ceiling outlet box NN Slide the canopy B up to the mounting bracket A and place the key hole on the canopy B over the loose mounting bracket screw BB on the mounting bracket A Turn the canopy B clockwise until it locks in place at the narrow section of the key holes Align the circular hole on the canopy B with the remaining hole on the mounting bracket A Secure the mounting bracket screw BB previously removed in the hole and tighten the two mounting bracket screws BB NOTE Adjust the mounting bracket screws BB as necessary until the canopy B and canopy bottom cover C are snug A Assembly Attaching the Fan Blades 1 0 Attaching the Fan Blades bend the blades G while installing
13. s AA with electrical tape Make sure there are no loose strands or connections Motor to receiver electrical connections Connect the black wire PP from the fan to the black wire AAA marked TO MOTOR L from the receiver L Connect the white wire RR from the fan to the white wire BBB marked TO MOTOR N from the receiver L Connect the blue wire QQ from the fan to the blue wire CCC marked For Light from the receiver L Receiver to house supply wires electrical connections Connect the black hot wire FFF from the ceiling to the black wire DDD marked AC in L from the receiver L Connect the white neutral wire GGG from the ceiling to the white wire EEE marked AC in N from the receiver L 11 If your outlet box NN has a ground wire HHH green or bare copper connect it to the fan ground wire III otherwise connect the hanger ball downrod assembly D ground wire to the mounting bracket A Secure each wire connection with a plastic wire nut AA provided with the electrical hardware After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box NN and the black and blue wires are on the other side Carefully tuck the wire connections up into the outlet box NN FFF GGG HHH HAMPTONBAY COM Please contact 1 877 527 0313 for furthe