1. with the holes in the coupling on top of the motor housing Figure 6 Carefully insert the clevis pin through the holes in the collar and downrod Be careful not to jam the clevis pin against the wiring inside the downrod Insert Pin in Locked the cotter pin through the hole near the end of Positioon the clevis pin until it snaps into its locked position as noted in the circle inset of Fig 6 FAILURE TO PROPERLY INSTALL COTTER PIN AS NOTED IN STEP 5 COULD RESULT IN FAN LOOSENING AND POSSIBLY FALLING 6 Tighten two set screws at top of the fan motor collar firmly and evenly Fig 6 Ceiling Mounting Bracket Canopy Bottom Cover Figure 5 Bottom Cover Re Cotter Installing Fan to the Electrical Box TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY TO AN OUTLET BOX OR SUPPORTING SYSTEM MARKED ACCEPTABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OUTLET BOX Pass the 120 volt supply wires through the center hole in the ceiling mounting bracket as shown in Figure 7 Install the ceiling mounting bracket on the outlet box with the screws and washers provided with your outlet box Figure 7 Security tighten the two mounting screws Carefully lift the fan assembly up to the ceiling mounting bracket and seat the hanger ball in the mounting bracket socket Make sure the tab on the mounting bracket socket is properly seated in the groove in th
2. and 4 pulls Off Speed settings for warm or cool weather depend on factors such as the room size ceiling height number of fans and so on 2 Light kit pull chain it controls the light kit in ON or OFF The slide switch controls directions forward switch left or reverse switch right 12 Warm weather Counter Clockwise direction A downward air flow creates a cooling effect as shown in Figure 19 This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Clockwise direction An upward air flow moves warm air off the ceiling are as shown in Figure 20 This allows you to set your heating unit on a lower setting without affecting your comfort Care of Your Fan Here are some suggestions to help you maintain your fan l Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure It is not necessary to remove fan from ceiling Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly cause an electrical shock You can apply a
3. conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather conditions A certain amount of wobble is normal and should not be considered a defect Servicing performed by unauthorized persons shall render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to Those r a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you The Hampton Bay shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance except as may otherwise be accorded by law Some states do not allow the exclusion of incidental or consequential damages so the above exclusion or limitation may not apply to you This warranty gives specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties Shipping costs for any return of product as part of a claim on the warranty must be paid by the customer IMPORTANT NOTE To ensure warranty service if ever ne
4. to your ceiling fan and continue normal operation MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPY ANY REPAIRS REFER TO THE SECTION MAKING ELECTRICAL CONNECTIONS Specifications FAN SIZE SPEED VOLTS AMPS WATTS RPM CFM 10 8 kgs 23 76 lbs These are approximate measures They do not include Amps and Wattage used by the light kit 14 12 3 kgs 27 06 lbs Hampton Bay Lifetime Limited Warranty lifetime warranty on motor The Hampton Bay warrants the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser Hampton Bay also warrants that all other fan parts excluding any glass or acrylic blades to be free from defects in workmanship and material at the time of shipment from the factory for a period of one year after the date of purchase by the original purchaser We agree to correct such defects without charge or at our option replace with a comparable or superior model if the product is returned to Hampton Bay To obtain warranty service you must present a copy of the receipt as proof of purchase All costs of removing and reinstalling the product are your responsibility Damage to any part such as by accident or misuse or improper installation or by affixing any accessories is not covered by this warranty Because of varying climatic
5. 325 475 Beverley Il 52 in Ceiling Fan Owner s Manual Beverley Il Ventilador de Techo de 1 32m Manual del Propietario th 1 115 A x ongratulations on your C purchase of a Hampton Bay ceiling fan Your new fan will be a beautiful addition to your home and will keep you comfortable throughout the year The Hampton Bay Fan Company offers a wide variety of ceiling fans We offer combinations of wood and brass finishes solid designer colors and our unique glass and crystal designs A large selection of light fixtures and light kits is also available Ask your dealer about other accessories that will allow you to further customize your fan We re certain that your Hampton Bay fan will provide you with many years of comfort energy savings and satisfaction To ensure your personal safety and to maximize the performance of your fan please read this manual thoroughly Beverley ll by Hampton Bay 52 Beverleyll Ceiling Fan by Hampton Bay Date Purchased Store Purchased Model No 325475 S Serial No Vendor No __ 219032 UPC 792145356097 Thank you for purchasing our ceiling fan This product has been manufactured with the highest standards of safety and quality Table of Contents Safety Rules sorc sireeni presidia 1 Unpacking Your Fan 2 Installing Your Fad 3 Installing the Light Kit 10 Operating Your Fan 12 Care
6. MBLY AND DISCARD PRIOR TO ATTACH ING BLADE ARMS FIG 11 Attach blades to blade arm using the screws with fiber washers provided Fig 12 Start a screw into the blade arm do not tighten Repeat for the 2 remaining screws and washers Rubber Packing Screws 8 amp Mounts Figure 11 2 Tighten each screw securely starting with the center screw Make sure the blade is straight Repeat steps for the remaining blades Screws E with Fiber j 3 Fasten the blade assemblies to the motor Washer housing by lining up the slots of the blade arms with the tabs on the motor housing then tighten the two screws and washers already installed in the blade arms Figure 13 Figure 13 TO REDUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE ARMS WHILE INSTALLING BALANCING THE BLADES OR CLEANING THE FAN DO NO INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES Figure 12 Blade Balancing The following procedure should correct most fan wobble Check after each step 1 Check that all blade and blade bracket screws are secure 2 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Measure this distance as shown in Figure 14 Rotate the fan until the next blade is positioned for measurement Repeat for each blade Measurement
7. SEE THAT ALL CONNECTIONS ARE TIGHT INCLUDING GROUND AND THAT NO BARE WIRE IS VISIBLE AT THE WIRE NUTS EXCEPT FOR THE GROUND WIRE ELECTRICAL DIAGRAMS ARE FOR REFER ENCE ONLY OPTIONAL USE OF ANY LIGHT KIT SHALL BE UL LISTED AND MARKED SUITABLE FOR USE WITH THIS FAN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE SUPPLY a hie E Ground Conductor Outlet Box Ground Lead Ground to Downrod Figure 9 Finishing the Fan Installation M Outlet Box Tuck connections neatly into ceiling outlet box 2 Slide the canopy up to mounting bracket and place the key hole on the canopy over the screw on the la y Mounting mounting bracket turn canopy until 1t locks in place at the narrow section of the key holes Fig 10 i i Bracket 3 Align the circular hole on canopy with the remaining hole on the mounting bracket secure by i Canopy tightening the two set screws Note Adjust the canopy screws as necessary until the canopy and canopy cover are snug Screws Fa 1 N e Bottom MAKE SURE THE TAB ON THE HANGER BRACKET PROPERLY SITS IN THE GROOVE IN THE HANGER BALL BEFORE ATTACHING THE CANOPY TO THE BRACKET BY TURNING THE HOUSING UNTIL IT DROPS INTO PLACE Figure 10 Attaching the Fan Blades MOTOR IS SHIPPED WITH RUBBER PACKING MOUNTS TO PREVENT MOVEMENT DURING TRANSPORTATION REMOVE 5 RUBBER PACKING MOUNTS FROM FAN MOTOR ASSE
8. canopy touches downrod remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to the mounting plate er Outlet Box Figure 4 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 available at any Home Depot store 3 Hanging the Fan REMEMBER to turn off the power Follow the steps below to hang your fan properly 1 Remove the decorative canopy bottom cover from the canopy by turning the cover counter clockwise Figure 5 2 Remove the mounting bracket from the canopy by removing the 1 of 2 screws from the bottom of the mounting bracket and loosening the other one a half turn from the screw head Next turn the canopy counter clockwise to removing the mounting bracket from the canopy Figure 5 3 Remove the clevis pin cotter pin and set screws from the top of the motor assembly Figure 6 NOTE Ifa longer downrod is needed take out the screw located in the hanger ball lower the hanger ball and remove the pin remove all 3 pieces from the downrod and assemble them onto the new longer downrod before proceeding step 4 The longer downrod is available at any Home Depot store 4 Route wires exiting from the top of the fan motor through the coupling cover canopy cover canopy and then through the ball downrod Figure 6 5 Align the holes at the bottom of the downrod
9. d fobs 2 Blade Attachment Hardware 16 Screws with Fiber Washers Electrical Hardware 3 Plastic Wire Nuts Balancing Kit Provide Strong lt Support Installing Your Fan Figures 1 3 are examples of different ways to mount the outlet box Tools Required Phillips screwdriver straight slot screwdriver step ladder and wire cutters de o Y Mounting Options Tf there isn t an existing UL listed mounting box then read the following instructions Disconnect the power by removing fuses or turning off circuit breakers Secure the outlet box directly to the building structure Use appropriate fasteners and building materials The outlet box and its support must be able to fully support the moving weight of the fan at least 35 lbs Do not use plastic outlet boxes TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN ONLY TO AN OULET BOX MARKED ACCEPT ABLE FOR FAN SUPPORT AND USE THE MOUNTING SCREWS PROVIDED WITH THE OULET BOX OUTLET BOX COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURE MAY NOT BE ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT l Outlet Box r1 a Outlet Box Figure 1 Figure 2 Recessed Outlet Box Figure 3 Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling The maximum angle allowable is 17 If the
10. e for most cleaning 11 upward and pushed carefully up into outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box All set screws must be checked and retightened where necessary before installation TO REDUCE THE RISK OF PERSONALL INJURY DO NOT BEND THE BLADE ARMS ALSO REFERRED TO AS FLANGES INSTALLING WHEN THE BRACKETS BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS IN BETWEEN ROTATING FAN BLADES TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT FAN TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT WITH THE SCREWS PROVIDED WITH THE OUTLET BOX FAN INCLUDES A DEPARTMENT OF ENERGY 2009 REGULATION LAMPING THIS PRODUCT OVER 190W WILL CAUSE THIS FAN TO NOT LIGHT PLEASE USE BULBS WITH A TOTAL WATTAGE UNDER THE 190W REGULATION 190W LIMITER TO COMPLY WITH THE e Unp acking Your Fan Unpack your fan and check the contents You should have the following items Set of blades 5 Canopy assembly Ball downrod assembly Coupling cover pw 2 pers Fan motor assembly WARNING DO NOT INSTALL OR USE FAN IF ANY PART IS DAMAGED OR MISSING CALL TOLL FREE 1 877 902 5588 Set of blade arms 5 Mounting plate Switch housing Light kit Glass shades 3 60 Watt candelabra bulbs 3 Pull chains an
11. e hanger ball Figure 8 This will help to balance the ceiling fan UL Listed Outlet Box Ceiling Mounting Bracket Mounting Screws Supplied with Electrical Box Figure 7 Figure 8 THE TAB IN THE RING MUST REST IN THE GROOVE OF THE HANGER BALL AS FIGURE 8 FAILURE TO PROPERLY SEAT THE TAB IN THE GROOVE COULD CAUSE DAMAGE TO WIRING Making the Electrical Connections REMEMBER to disconnect the power If you feel you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician Follow the steps below to connect the fan to your household wiring Use the wire nuts supplied with your fan Secure the wire nuts with electrical tape Make sure there are no loose strands or connections 1 Connect the ground conductor of the 120V supply this may be a bare wire or a wire with green colored insulation to the green ground lead s of the fan Figure 9 Connect the fan motor white wire to the supply white neutral wire using a wire nut Figure 9 Connect the fan motor black wire to the supply black hot wire using a wire nut Figure 9 Connect the blue wire for light kit to the black household supply wire 5 Turn wire nut connections upward spreading them apart so the green ground will be on one side of the outlet box and the white black and blue wire will be on the other side and push carefully up into the outlet box CHECK TO
12. eded please register your fan at www tal usa com registration You must present a copy of the original purchase receipt to obtain warranty service Ceiling Fan Parts amp Service Department 2919 E Philadelphia Street Ontario CA 91761 U S A Attach receipt here for easy location
13. he switch housing then install the light kit assembly onto the mounting plate with 3 screws provided Be sure to tighten all screws Fig 17 Remove the lock ring from the socket by turning the lock ring clockwise until it unlocks Insert the glass into the glass holder and turn the lock ring counter clockwise to tighten the glass Repeat for the remaining glass Fig 17 Install 3 x 60 Watt candelabra bulbs included Restore power and your light kit is ready for operation Nut Lock Washer gt 0 Switch Housing Figure 16 Fan without Light Kit Optional BEFORE STARTING INSTALLATION DISCON NECT THE POWER BY TURNING OFF THE CIRCUIT BREAKER OR REMOVING THE FUSE AT FUSE BOX TURNING POWER OFF USING THE FAN SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRIC SHOCK q 4 Wire Connection 1 Holding the switch housing under your fan snap the wire connection plugs together 2 Install the switch housing to the mounting plate with screws provided Fig 18 Switch Housing Light Kit Y Assembly bs Shade Gm Lock Ring Bulbs Figure 18 Figure 17 11 Operating Your Fan WAIT FOR FAN TO STOP BEFORE REVERSING THE DIRECTION OF THE BLADE ROTATION Turn on the power and check the operation of your fan There are two pull chains available in your fan 1 3 speed pull chain it controls the fan speed as follows 1 pull High 2 pulls Medium 3 pulls Low
14. light coat of furniture polish to the wood blades for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish There is no need to oil your fan The motor has permanently lubricated sealed ball bearings Troubleshooting SOLUTION PROBLEM Fan will not start Fan sounds noisy Lights shut off and will not come back on 1 2 Check main and branch circuit fuses or breakers Check line wire connections to the fan and switch wire connections in the switch housing Make sure all motor housing screws are snug Make sure the screws that attach the fan blade bracket to the motor hub is tight Make sure wire nut connections are not rattling against each other or the interior wall of the switch housing Allow a 24 hour breaking in period Most noises associated with a new fan disappear during this time If using ceiling fan light kit make sure the screws securing the glassware are tight Check that the light bulb is also secure Make sure there is a short distance from the ceiling to the canopy It should not touch the ceiling Make sure your ceiling box is secure and rubber isolator pads are used between mounting bracket and outlet box This unit is equipped with a wattage limiting device Lamping in excess of 190 watts will disable your ceiling fan s light kit To reset your light kit you must turn the power off and relamp keeping the wattage under 190 watts Restore power
15. of Your Fan 13 Troubleshooting 13 Specifications soms e ova REX Ya 14 Warranty Information 15 Safety Rules Read and Save These Instructions To reduce the risk of electric shock insure electricity has been turned off 10 After making electrical connections spliced conductors should be turned at the circuit breaker or fuse box before beginning All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 1999 and local electrical codes Electrical installation should be performed by a qualified licensed electrician WARNING To reduce the risk of electrical shock or fire do not use this fan with any solid state fan speed control device It will permanently damage the electronic circuitry CAUTION To reduce the risk of personal injury use only the screws provided with the outlet box The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds Use only UL Listed outlet boxes marked FOR FAN SUPPORT The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor Avoid placing objects in path of the blades To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitabl
16. s deviation should be within 1 8 Run the fan for 10 Minutes 3 Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable Touching Ceiling Figure 14 Installing the Mounting Plate l Remove 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the 2 screws previously loosened and the one previously removed Fig 15 je Screws Figure 15 10 Installing the Light Kit A A BEFORE STARTING INSTALLATION DISCON NECT THE POWER BY TURNING OFF THE CIRCUIT BREAKER OR REMOVING THE FUSE AT FUSE BOX TURNING POWER OFF USING THE FAN SWITCH IS NOT SUFFICIENT TO PREVENT ELECTRIC SHOCK TF YOU DO NOT PLAN TO INSTALL THE LIGHT KIT WITH YOUR FAN AT THIS TIME SKIP STEP 1 6 Remove the plug from the switch housing Attach the light kit to the switch housing by feeding the light kit wires black and white through the hole of switch housing and then screw it onto the switch housing by nut amp lock washer Be sure it is tight enough to prevent light kit from vibrating loose Fig 16 While holding the light kit assembly under your fan snap together the wire connection plugs Fig 17 Carefully push all wires back into t
Download Pdf Manuals
Related Search
Related Contents
ESCET Version 0.7 User Manual C-21T.commu 取扱説明書 T。SHーBA 東芝ネオペ-ルブラケッ ト取扱説明書 保管用 "取扱説明書" General Fair Wear & Tear Missing Service Manual FX4 Fluid Pump Assemblies Manuel d`utilisation GT-8500 1 comportamiento poblacional de insectos plagas en el cultivo de Bedienungsanleitung testo 316-EX Paxar TC6039OH User's Manual Copyright © All rights reserved.