Home
Hunter 59054 Installation Guide
Contents
1. Position the canopy so that when lifted into place the canopy fits into the hanging bracket as shown Screw Holes Insert the two canopy screws found in the hardware bag Note Fan style may vary www HunterFan com 1 888 830 1326 M3519 01 05 14 14 Hunter Fan Company Attach each blade to a blade iron using four blade washers found in the hardware bag and four blade assembly screws found in the hardware bag Blades Your blades are shielded with Dust Armor which is a nanotechnology coating that repels dust For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning agents may damage the finishes 11 www HunterFan com 1 888 830 1326 Feed the wire plug through the center hole of the upper switch housing then wrap keyhole slots around the screws and twist counterclockwise Screw two housing assembly screws from the hardware bag halfway into the motor housing It does not matter which two screw holes you choose Insert the third screw found in the hardware bag into place and then tighten all three screws Switch Housing Make sure the upper switch housing is securely attached to the mounting plate Failure to properly secure all 3 assembly screws could result in the switch housing fixture falling 12 M3519 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Connect the plugs from the upper and lower switch housings
2. I L I N G F R O M C E I L I N G B R A C K E T green yellow stripe grounding green yellow stripe green yellow stripe black blue yellow blue Note To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight Using the orange wire connectors from the remote control hardware bag connect the blue wire from the receiver to the blue wire or possibly black with white stripe wire from the fan Connect the yellow wire from the receiver to the black wire from the fan F R O M F A N F R O M F A N F R O M R E C E I V E R Using the orange wire connectors from the hardware bag connect the black wire ungrounded from the ceiling to the black wire from the receiver Connect the white wire grounded from the ceiling to both the white wire from the receiver and the white wire from the fan F R O M C E I L I N G black ungrounded white grounded black white F R O M F A N white 9 M3519 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 10 M3519 01 05 14 14 Hunter Fan Company Canopy Lift the canopy into place so that the screw holes are aligned
3. Make sure to line up the colored markings on the connectors Partially install two of the switch housing screws found in the bag Align the keyhole slots in the light kit housing with the housing assembly screws Make sure all the wires from the fan and the light kit are snug inside the center of the light kit not pinched in between the upper switch housing and the light kit or hanging out of the sides Light Kit Turn the light kit clockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws securely Switch Housing Screw Make sure the lower switch housing is securely attached to the upper switch housing Failure to properly secure all three assembly screws could result in the light fixture falling 13 M3519 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 Light Kit continued CONGRATULATIONS YOU RE DONE Align the notches in the glass bowl with the tabs in the light kit Attach the glass bowl to the light kit by twisting it clockwise until it snaps into place See next page for fan operation instructions Install the 18 Watt dimmable CFL bulb into the socket When necessary replace with bulbs of same wattage Tab Bulb Notch M3519 01 05 14 14 Hunter Fan Company 14 www HunterFan com 1 888 830 1326 Within 3 minutes of
4. 1326 M3519 01 05 14 14 Hunter Fan Company 16 For cleaning the fan use soft brushes or cloths to prevent scratching Cleaning products may damage the finishes Reverse Switch Operation Maintenance amp Cleaning continued To switch the direction of air flow move the reverse switch to the opposite position You will need to remove the light kit glass to do so Press the Fan Off button for at least three seconds to initiate the Safe Exit Mode The lights will flash for visual confirmation The lights will stay on 50 brightness for 15 seconds and then begin to dim After a total of 30 seconds the lights will be completely off Note For CFL lighting the lights will stay on 100 brightness for 30 seconds After a total of 30 seconds the lights will be completely off The Safe Exit Program gives you about thirty seconds of light when you turn the lights off to exit the room before the lights go out To use Safe Exit Safe Exit www HunterFan com 1 888 830 1326 M3519 01 05 14 14 Hunter Fan Company 17 Troubleshooting Fan doesn t work Make sure power switch is on Pull the pull chain to make sure it is on Push the motor reversing switch firmly left or right to ensure that it is engaged Check the circuit breaker to ensure the power is turned on Make sure the blades spin freely Turn off power from the
5. the downrod at least 4 5 full turns until it stops The wires can be cut but leave at least 8 extending from the top of the downrod Downrod continued 8 3 8 Use the Allen wrench to securely retighten the setscrew If the setscrew is not tightened securely the fan may fall 1 888 830 1326 www HunterFan com Note The adapter cover is not used for low profile mounting 7 M3519 01 05 14 14 Hunter Fan Company 1 888 830 1326 8 M3519 01 05 14 14 Hunter Fan Company www HunterFan com Downrod continued DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES Place the downrod ball into the slot in the ceiling bracket Install the adapter cover screws and tighten them securely Put the wires and downrod through the canopy Let the canopy sit loosely on top of the fan www HunterFan com 1 888 830 1326 Wiring Turn the splices upward and push them carefully back through the hanger bracket into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box Refer to CAUTION c 1 on pg 2 Using an orange wire connector from the hardware bag connect the 3 grounding wires green green yellow stripe or bare copper coming from the ceiling downrod and hanging bracket F R O M R E C E I V E R F R O M C E
6. circuit breaker then loosen the canopy and check all the connections according to the wiring diagram on page 9 Make sure the battery is working Check the plug connection in the switch housing Excessive wobbling Tighten all of the blade and blade iron screws until they are snug Turn the power off support the fan carefully and check that the hanger ball is properly seated Use the provided balancing kit and instructions to balance the fan Noisy operation Tighten the blade and blade iron screws until they are snug Check to see if any of the blades are cracked If so replace all of the blades Remote control of fan is erratic Make sure the battery is installed correctly Install a fresh battery Transmitter only works when held at close range Install a fresh battery CFL bulbs flicker or do not dim Turn the power switch off and back on Within three minutes hold down the Fan Off button while pressing the Light button twice If the problem is not corrected repeat the process up to three times If you have multiple remotes or multiple remote controlled fans installed on the same circuit breaker and you are experiencing interference or faulty operation of your remote controls please go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for information on how to correct this iss
7. e to the floor Select a downrod length Assess ceiling angle Read and Save These Instructions This product conforms to UL Standard 507 WARNINGS CAUTIONS Must be able to secure the fan to building structure or fan rated outlet box 1 2 3 Standard Downrod for ceilings 8 10 feet high Shorter Downrod for fans installed close to ceiling Longer Downrod for ceilings 10 feet or higher 2 Ceiling angles greater than 34 will require an Angled Mounting Kit See page 4 for details w 1 To reduce the risk of fire electrical shock or personal injury mount fan directly from building structure and or an outlet box marked acceptable for fan support of 70 lbs 31 8 kg and use the mounting screws provided with the outlet box w 2 To avoid possible electrical shock before installing or servicing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel w 3 To reduce the risk of fire electrical shock or motor damage use only Hunter Speed Controls w 4 To reduce the risk of personal injury do not bend the blade brackets when installing the blade brackets balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades c 1 All wiring must be in accordance w
8. eiling angle is greater than 34 you will also need an Angled Mounting Kit sold separately Guide Touches BOTH Ceiling amp Wall S I T U A T I O N 1 Guide Touches Wall but NOT Ceiling S I T U A T I O N 2 You need BOTH a Longer Downrod amp an Angled Mounting Kit You need ONLY a Longer Downrod most common If you have a flat ceiling Hang your fan by a standard downrod included Mounting Options Use Standard Mounting or Low Profile Mounting to hang the fan from a flat ceiling Use Angled Mounting to hang the fan from a vaulted or angled ceiling 4 34 O CEILING WALL OPTION 1 Standard Mounting OPTION 2 Angled Mounting 2 3 SLIDE toward ceiling PLACE against wall 1 FOLD on dotted line 34 Use the three steps below to determine if your ceiling angle is greater than 34 Support Structure Ceiling Outlet Box required Angled Mounting Style Standard Mounting Style Support Structure Ceiling Outlet Box required 1 888 830 1326 www HunterFan com Ceiling Bracket 5 M3519 01 05 14 14 Hunter Fan Company Refer to warning w 1 on pg 2 To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location For angled ceilings point open
9. ing toward peak If you are unable to do this call Technical Support at 1 888 830 1326 Make sure all four bumpers are still attached Use wood screws included when securing to support structure with approved electrical outlet box Drill 9 64 pilot holes in support structure to aid in securing ceiling bracket with hardware found in the hardware bag Use machine screws provided with outlet box when securing to existing ceiling fan rated outlet box Make sure it is securely installed and is acceptable for fan support of 31 8 kg 70 lbs or less OFF Turn Power 1 888 830 1326 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Longer Downrod for angled ceilings or ceilings 10 or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for ceilings 8 10 high Option 1 Option 2 Option 3 skip to next page If you need a different downrod length follow these steps Steps 1 5 to remove standard downrod pipe Steps 6 10 to reassemble with new pipe Included pre assembled www HunterFan com Sold Separately 6 M3519 01 05 14 14 Hunter Fan Company 8 3 8 C U T amp S T R I P not to scale Using the provided Allen wrench loosen the setscrew on the adapter to install the pipe and ball assembly Insert the downrod through the adapter cover Hand tighten
10. ith national and local electrical codes ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician c 2 Use only Hunter replacement parts This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications www HunterFan com 1 888 830 1326 Tools Needed Ladder Screwdrivers Pliers Wire Strippers 3 M3519 01 05 14 14 Hunter Fan Company Power Drill optional 9 64 Drill Bit optional If mounting to a support structure you will also need these tools Allen Wrench included If you are installing multiple remote controlled fans on the same circuit breaker you may need to perform a few extra steps to prevent interference or faulty operation of your remote controls Go to www HunterFan com FAQs and click How do I properly install multiple remote controlled fans for more information www HunterFan com 1 888 830 1326 4 M3519 01 05 14 14 Hunter Fan Company Mounting Options continued If you have an angled ceiling 1 You will need a longer downrod sold separately 2 If your c
11. restoring power to the fan press both the Fan Off button and the High button for at least 4 seconds Your fan will turn on low to indicate successful syncing If it does not turn off power to your fan wait 1 minute then try again If using the transmitter with multiple fans repeat this process for each fan Note The remote must be paired before the fan will operate Fan Off High Rocker Style Plate Switch Cover Plate Removed Tabs To install the transmitter cradle remove the two screws holding the switch cover plate Do not remove the cover plate Orient the cradle by lining up the two mounting holes with those on the cover plate Insert and tighten the screws Do not over tighten Note For rocker style cover plates break off the tabs by pushing outward To turn on fan press a fan speed button Speeds range from off 0 to high 3 Quickly press the Light button to turn the lights off and on Medium Speed Light High Speed Fan Off Low Speed Operation Maintenance amp Cleaning ON Turn Power To access the battery compartment remove the small Phillips head screw that secures the battery door to the transmitter assembly The battery should be installed with the positive side up Replace with a CR2032 battery when necessary Phillips Head Screw Battery Door 15 M3519 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830
12. ue
13. www HunterFan com 1 888 830 1326 PAG E 12 PAG E 13 PAG E 5 PAG E 17 30 inches 7 feet PAG E 2 What to Expect with Your Installation Ceiling Bracket Ladder PAG E 3 Tools Needed Troubleshooting Switch Housing Light Kit Table of Contents Mounting Options PAG E 6 PAG E 9 Wiring Canopy Downrod PAG E 10 Blades PAG E 4 15 PAG E Congratulations on purchasing your new Hunter ceiling fan It will provide comfort and performance in your home or office for many years This installation and operation manual contains complete instructions for installing and operating your fan We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world To register your fan please visit www HunterFan com register Save your receipt for proof of purchase Operation Maintenance amp Cleaning PAG E 11 1 M3519 01 05 14 14 Hunter Fan Company www HunterFan com 1 888 830 1326 M3519 01 05 14 14 Hunter Fan Company 1 888 830 1326 1 888 830 1326 What to Expect with Your Installation Know your wiring If you are unfamiliar with wiring use a qualified electrician You may need a friend to help you Check box to see fan weight Assess location 30 inches from blade tip to nearest wall or obstruction 7 feet from bottom edge of blad
Download Pdf Manuals
Related Search
Related Contents
Benutzerhandbuch DOMOTESTA RDO3x4A... V5.xx 2ème Comité de pilotage du 13 octobre 2014 - SRI-SI MANUAL DE USUARIO - Intranet de la Asamblea Nacional Manual de Usuario Détecteur de fuites VAKUMATIK Type IVF R34 - ASF Samsung EcoGreen PM800 - 2.5" SATA 3.0Gb/s MLC SSD 256GB Instructions for use and installation Istruzioni per l`uso e l Copyright © All rights reserved.