Home

Hunter 59000 Installation Guide

image

Contents

1. Problem Lights shut off suddenly but fan is still operating 1 Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the light socket 2 Turn the power to the fan off at the wall switch Wait 5 minutes then resume power to the fan Problem CFL bulbs flicker when controlled by a dimming remote or wall control 1 CFL light bulbs are not usually made for dimming Replace the CFL bulbs with dimmable light bulbs or install the fan in a location without a dimming control If you need parts or service assistance please call 888 830 1326 In Canada call 866 268 1936 or visit us at our website at http www HunterFan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 17 M0021 01 04 18 13 Hunter Fan Company
2. same manner as the fan finish In cold weather use upward air flow pattern To Change Airflow Direction Turn the fan off and let it come to a complete stop Unscrew the cap at the bottom of the glass globe and remove the cap finial and glass shade Slide the reversing switch on the fan to the opposite position Reversing BE se After reinstalling glass finial and cap restart fan NIER 16 M0021 01 04 18 13 Hunter Fan Company 10 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 Make sure the blades are securely attached to the blade irons according to the blade assembly instructions provided 2 After thoroughly verifying the blades are securely attached to the blade irons follow the instructions in the enclosed balancing kit to balance the fan 3 Turn power off support fan very carefully and check that the hanger ball is properly seated
3. For Your Records and Warranty Assistance gt a mM f e For reference also attach your receipt or a copy a A mi kml J Lt of your receipt to the manual Owner s Guide and Installation Manual SINCE 1886 8 Form M0021 01 20130418 2013 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings Table Of Contents 1 e Getting Ready 2 Installing the Ceiling Bracket 3 Assembling and Hanging the Fan 8 4 e Wiring the Fan 5 Installing the Canopy 6 Assembling the Blades 7 Completing Your Installation With a Bowl Light Fixture 8 Operating the Remote Control and Mounting the Holder 9 e Operating and Cleaning Your Ceiling 10 Troubleshooting 2013 Hunter Fan Company M0021 01 READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Use only Hunter replacement parts To reduce the risk of personal injur
4. ING Fan may fall if not assembled as directed in these installation instructions You can assemble your fan for standard or angled mounting as shown in steps below 3 1 Unbundle the wires from the fan 3 2 Feed the wires from the fan through the downrod Note Make sure all the wires are on the same side of the metal dowel pin inside the downrod 3 3 Loosen the square head setscrew on the adapter in order to install the downrod 3 4 Insert the downrod into the adapter Tighten by turning the downrod assembly at least 4 5 full turns until it stops Note When the downrod assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the setscrew with a wrench or pliers A WARNING If the setscrew is not tightened securely the fan may fall 3 5 Optional The wires can be cut shortened but leave at least 8 extending from the top of the downrod 3 6 Raise the fan and place the downrod ball into the ceiling bracket 8 Setscrew gt y lt m Downrod he vl Canopy Steps 3 1 3 4 lt Ceiling Bracket m Downrod Step 3 6 M0021 01 04 18 13 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician 4 1 Make sure the power is still off at the brea
5. ag LIVE IN 4 6 Check each connection to make sure no bare wire or wire strands are visible Turn wire connectors upward and push them up into the outlet box Be sure to separate the grounded wires from the ungrounded wires inside the outlet box 4 7 Position the receiver in the canopy so that the antenna is close to the edge of the ceiling bracket for clear reception 5 Installing the Canopy 5 1 Raise the canopy over the ceiling bracket and align the two holes of the canopy and the ceiling bracket 5 2 Insert and tighten the canopy screws securely Hanger Bracket Canopy Screw f A Steps 5 2 10 M0021 01 04 18 13 Hunter Fan Company 6 Assembling the Blades 6 1 Insert grommets into the holes in the blades Step 6 1 Detail 6 2 Install one blade onto a blade iron with three blade assembly screws 6 3 Repeat Steps 6 1 6 2 until all three blades are installed Steps 6 1 6 2 Blade Assembly Screw lI M0021 01 04 18 13 Hunter Fan Company 7 Completing Your Installation With a Bowl Light Fixture A WARNING Use only the light fixture supplied with this fan model 7 1 Partially install two housing assembly screws into the mounting plate on the bottom of the fan 7 2 Feed the upper plug connector from the motor through the center opening of the shroud 7 3 Slide the partially installed screws through the keyhole slots in the
6. d to the position BEFORE installation Do not use pull chain switch to change the fan speed after installation as damage to your fan or remote may result The speed of the fan should only be changed by the Hunter control Set the ceiling fan light kit to the ON position before installation The light level should only be changed by the Hunter control M0021 01 04 18 13 Hunter Fan Company 9 1 9 2 9 3 9 4 9 Operating and Cleaning Your Ceiling Fan The remote controls power to the fan The fan has four settings in sequence High Medium Low and Off Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You In warm weather use may use an artistic agent but never abrasive cleaning agents as downward air flow pattern they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the
7. e ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Keyhole saw e 2 x 4 support brace e UL approved octagonal 4 x 1 1 2 outlet box e Two 8 x 1 1 2 wood screws and washers Installing Multiple Fans e Approved connector for electrical wire If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 866 268 1936 6 M0021 01 04 18 13 Hunter Fan Company 2 Installing the Ceiling Bracket A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outle
8. ght fixture falling Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts its light output Exceeding the wattage limit marked on the MAX wattage sticker affixed to the light socket s may result in fire hazard or improper operation 13 M0021 01 04 18 13 Hunter Fan Company 7 10 7 11 7 12 7 13 7 Completing Your Installation With a Bowl Light Fixture Continued Install the included bulbs 40 W max Hold the glass bowl up so it fits in the shroud Hold the cover plate up to the bottom of the glass bowl and secure them both by screwing the finial into the threaded rod on the bottom of the light fixture Attach the extra pull chains with pendants included to the light and fan pull chains using the breakaway connector You may find the breakaway connector on the end of the extra chains a ni lt gt 75 IMIN D A 4 WANA IN z SNR T2 V9 N INA 4 UM TR as Y a a WW ay AP wt td A lt Gr P O49 a N Breakaway Connector Steps 7 10 7 11 14 M0021 01 04 18 13 Hunter Fan Company 8 Operating the Remote Control and Mounting the Holder The Safe Exit Program gives you about 30 seconds of light when you turn the lights off to exit the room before the lights go out To 8 1 Turn on electrical power to the fan 8 2 To install or replace the battery remove the door from the back of the transmitter I
9. holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor diameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to the support brace or joist with two 8 x 1 1 2 wood screws and washers The bottom of the outlet box must be recessed a minimum of 1 16 into the ceiling Step 5 Prepare the Wiring 5 1 Make sure the circuit breakers to the fan supply line leads and associated wall switch location are turned off If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 5 2 Thread the fan supply line through the outlet box so that the fan supply line extends at least 6 beyond the box 5 3 Attach the fan supply line to the outlet box with an approved connector available at any hardware store or electrical supply house 5 4 Make certain the wiring meets all national and local standards and ANSI NFPA 70 You have now successfully prepared your ceiling fan site For instructions to install A CAUTION All wiring must be in oe I l accordance with national and local your ceiling fan go to your fan manual and continue with Section 2 e Installing the oi at codes and ANSI NFPA 70 If Ceiling Plate you are unfamiliar with wiring use a qualified electrician 4 M0021 01 04 18 13 Hunter Fan Company Installer
10. ker box 4 2 To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all wire connections use the wire connector provided 6ulpunos6 1eq 10 uaasb green with A CAUTION Be sure no bare wire or wire strands are visible after em Gite ellow stripe making connections 20 25 a 57 D 4 3 Using a large orange wire connector connect the green or bare wire grounding wire from the ceiling to the green with yellow striped wire from the ceiling bracket and the green with yellow striped wire from the downrod 4 4 Using the small blue wire connector connect the wires from the fan as follows e The blue wire from the fan to the blue wire from the receiver marked on red tag LIGHT OUT e The black wire from the fan to the black wire from the receiver marked on red tag FAN OUT e The white wire from the fan to the white wire from the receiver marked on red tag COMMON OUT Wire Connector 9 M0021 01 04 18 13 Hunter Fan Company 4 Wiring the Fan continued 4 5 Using the large wire connectors connect the white wire grounded and the black wire ungrounded from the ceiling as follows e The white grounded wire from the ceiling to the white wire from the receiver marked on white tag NEUTRAL IN e The black ungrounded wire from the ceiling to the black wire from the receiver marked on white t
11. me in contact with the rotating fan blades during WDbstruction 7 Minimum Height normal operation Blades to ee FI e The fan blades are at least 7 feet above the floor and the ceiling is oor at least 8 feet high The fan blades have no obstructions to airflow such as walls or posts within 30 inches of the fan blade tips e The fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan Checklist for Existing Fan Site If you want to use an existing fan site complete the following checklist to determine Suitable Existing Fan Site if the site is acceptable and safe for your new Hunter fan If you cannot check off WS lt lt every item prepare a new fan site as described on this page Fan Support System Fan Support System e Fan attaches directly to building structure e Fan support system will hold full weight of the fan and light kit Ceiling Hole The outlet box clearance hole is directly below the joist or support brace Outlet Box e The outlet box is an UL approved octagonal 4 x 1 1 2 outlet box or as specified by the support brace manufacturer e The outlet box is secured to the joist or support brace by wood screws and washers through the inner holes of outlet box The outer holes of the outlet box are aligned with joist or support brace e The bottom of the outlet box is recessed a minimum of 1 16 into ceiling Fan Support Outlet B
12. nsert the battery into the use Safe Exit compartment observing proper polarity placement Press the Fan Off button for at least three seconds to initiate the Safe Exit Mode Note The remote must be paired before the fan will The lights will flash for visual confirmation operate e ie lights will stay on 50 rigning for 15 seconds and then begin to dim After a total of 30 seconds the lights will 8 3 Within 3 minutes of restoring power to the fan press be completely off both the Fan Off button and the High button for at Nesp ror gr Sane he iebes LTY a Oot the least 4 seconds Your fan will turn on low to indicate successful syncing If it does not turn off power to your fan wait 1 minute then try again If using the transmitter with multiple fans repeat this process for each fan lig ts will be completely off ooo i Fan Speed 8 4 The remote has individual buttons for setting the fan EE k Medium speed and light Refer to the figure on the right Note For best operation start the fan by pressing high then select your desired speed 8 5 The light button turns the light Push the light button again to turn off the light 8 6 When necessary replace the battery with a 12 V alkaline battery 8 7 You can mount the remote holder to any toggle switch plate with the screws already in the switch plate Or you can simply mount the remote holder on the wall Attention Use the pull chain switch to set the fan spee
13. ox System Wiring e The electrical cable is secured to outlet box by an approved connector e Six inches of lead wires extend from outlet box If your existing fan site is suitable skip ahead to Section 2 Installing the Ceiling Plate 3 M0021 01 04 18 13 Hunter Fan Company Preparing the Fan Site continued Step 2 Cut the Ceiling Hole 2 1 Locate the site for the ceiling hole directly below the joist or support brace that will hold the outlet box and fan 2 2 Cut a 4 diameter hole through the drywall or plaster of the ceiling You will use the hole to install the support brace and outlet box Step 3 Install a Support Brace If Necessary Determine if there is a ceiling joist directly above the ceiling hole If the joist is there determine if it is positioned to allow you to recess the outlet box a minimum of 1 16 into the ceiling If NOT install a support brace as follows 3 1 Attach a 2 x 4 support brace between two joists Position it to allow you to recess the bottom of the outlet box a minimum of 1 16 into the ceiling 3 2 Check the support brace to ensure it will support the full weight of the fan and light kit Step 4 Install the Outlet Box 4 1 Obtain a UL approved octagonal 4 x 1 1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer
14. s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 2 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of two ways depending on ceiling height and your preference Standard or Angled mounting The steps in this manual include instructions for both Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 5 M0021 01 04 18 13 Hunter Fan Company l Getting Ready To install a ceiling fan be sure you can do the following e Locate th
15. shroud Turn the shroud counter clockwise until the screws are nestled in the narrow ends of the keyhole slots 7 4 Install a third housing assembly screw into the remaining screw hole in the shroud Securely tighten all three screws 7 5 Install six 6 32 machine screws into the outer holes in the shroud 12 Housing Assembly Shroud Screw M0021 01 04 18 13 Hunter Fan Company 7 e Completing Your Installation With a Bowl Light Fixture Continued 7 6 Connect the upper plug connector from the fan to the lower plug connector in the light fixture Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product 7 7 Partially install two housing assembly screws into the shroud 7 8 Slide the keyhole slots in the light fixture into the partially installed screws Turn the light kit counter clockwise until the screws are nestled in the narrow ends of the keyhole slots 7 9 Install a third housing assembly screw into the remaining screw hole in the light fixture Securely tighten all three screws Step 7 7 A CAUTION Make sure the shroud is securely attached to the Peat switch housing mounting plate Failure to properly attach and oe y tighten all three assembly screws could result in the switch housing S and li
16. t box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 2 1 Note The ceiling bracket may be mounted to an existing ceiling fan rated outlet box If the outlet box is not ceiling fan rated Drill two pilot holes into the wood support structure The pilot holes should be 9 64 in diameter and through the outermost holes in the outlet box 2 2 Your fan comes with four neoprene noise isolators Position the isolators between the ceiling bracket and the ceiling by inserting the raised areas on each isolator into the holes in the ceiling bracket 2 3 Align the slotted holes in the ceiling bracket with the pilot holes you drilled in the wood support structure 2 4 Place a flat washer on each of the two 3 wood screws and pass the screws through the slotted holes in the ceiling bracket into the pilot holes you drilled 2 5 Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Note The isolators should be flush against the ceiling Flat Washer 3 Wood Screw ements FHENUNNUEDEDOUUNU RE be 7 Isolator co Q Ceiling Bracket NE Steps 2 3 2 5 For angled ceilings point opening toward peak M0021 01 04 18 13 Hunter Fan Company 3 Assembling and Hanging the Fan A WARN
17. y attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls which are solid state This product conforms to UL STD 507 and is certified to STD C22 2 No 113 Wash your hands after your fan installation is complete 2 04 18 13 Hunter Fan Company Preparing the Fan Site Step 1 Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings gt B0 From S _ Choose a fan site where all or 8 Minimum A l earest Ceiling e No object can co