Home

Hunter 27181 Instructions / Assembly

image

Contents

1. Quiet Fan Control Ratings 120 VAC 1 6 A 60 Hz 4 Speed Slide Control Model 27181 Read and save these instructions Caution Risk of Electrical Shock All wiring must be performed in accordance with national and local electrical codes Use only to control a single paddle blade ceiling fan Notes 1 For use only with electrically reversible ceiling fans rated at 1 6 A or less Not for use with any other light ing fixtures or electrical appliances 2 Not for use with shaded pole or Installation Instructions 1 Set the ceiling fan s speed to the HIGH position before installing this control Do not change the ceil ing fan s speed setting after your speed control is installed as damage to your ceiling fan or All Fan control may result 2 Verify proper operation of the ceiling fan wall switch before installation Improper wiring can damage the control and will void the warranty 3 Disconnect power to ceiling fan at the main electric panel Remove fuse or switch circuit breaker to OFF position 4 Refer to the Installation Figure for your All Fan speed control Remove wallplate to expose the wiring and disconnect the existing switch Install in a metal or plastic wallbox non reversible motors Not recom mended for use with the Hunter Original For Hunter Original series fans use Hunter control model numbers 22691 26591 or 22798 3 Separate wiring is recommended for ceiling fan light kits
2. If the fan motor and light kit are connected together this fan speed control may be used only when the light kit is OFF To use the fan motor and light kit together this control must be set to HIGH speed only 4 MEDIUM and both LOW speeds may vary from the ceiling fan s factory set speeds because of motor variations 5 If 4 wall wires are visible connect each black wire lead to the All Fan speed control s black wire If 2 wires are visible connect each to an All Fan speed control lead Use the wire nuts supplied to make the connections Refer to the Wiring Diagram which shows the proper connections If a ground wire is provided in your electrical box attach it to the ground screw near the bottom of the mount ing plate 6 Gently push wires and speed con trol into switch box Attach the All Fan speed control to switch box with the two screws supplied 7 Mount wallplate over control with existing screws 8 Move slider to the OFF position 120VAC 60Hz Neutral Wiring Diagram 9 Restore power at main electrical panel 10 Operate ceiling fan moving slider to the desired speed For best operation select HIGH speed until motor starts then select desired speed Form 41312 6 98 Control deslizable para ventilador de 4 velocidades Lea y guarde estas instrucciones Cuidado Riesgo de choque el ctrico Todo el cableado y conexiones se deben hacer de acuerdo con los c
3. RESPECT TO ANY CONTROL IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL This warranty excludes malfunctions or failures which were caused by repairs by per sons not authorized by us mishandling improper installation modifications or damage to the Control while in your possession or unreasonable use This warranty does not apply j to batteries or to deterioration or damage to the re del control de velocidad All Fan a un alam re negro Si hay 2 alambres visibles conecte cada uno a un ambre del control de velocidadAll Fan Use las tuercas de alam res suministradas con el control para hacer las conexiones onsulte el Diagrama de Conexiones que muestra la forma cor recta de conectar los alambres Si su caja el ctrica contiene un alambre de tierra con ctelo al tomillo di tierra ubicado cerca de la placa de montaje inferior 6 Empuje los alambres y el control de velocidad con mucho cuidado dentro de la caja del interruptor Asegure el control de velocidad All Fan a la caja del interruptor con los dos tomillos suministrados OTWYUTTU product caused by the use of faulty batteries To obtain a replacement return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 2500 Frisco Avenue Memphis Tennessee 38114 IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SOME ST
4. ATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITA TIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE
5. digos el ctricos nacionales y locales Notas 1 Para uso solamente con ventiladores de cielo raso que sean el c tricamente reversibles y con capacidades de 1 6A o menores No se debe usar con ninguna otra l mpara ni aparato el ctrico 2 Se recomienda el uso de un circuito separado para los conjuntos de luces de los ventiladores de cielo raso Si el motor del ventilador y el conjunto de luces se conectan juntos el control de velocidad del motor solamente se podr usar cuando las luces est n apagadas Para usar el motor del ventilador y el conjunto de luces juntos este control se debe ajustar a alta 7 Monte la placa de la pared sobre el control con los tornillos existentes 8 Mueva la palanca deslizable a la posici n OFF apagada 9 Vuelva a conectar la energ a el ctrica en el panel el ctrico principal 10 Haga funcionar el ventilador de cielo raso moviendo la palanca deslizable a la velocidad deseada Para la mejor operaci n seleccione Alta Velocidad hasta que el motor arranque y entonces seleccione la velocidad deseada HUNTER FAN COMPANY ALL FAN CONTROL LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original purchaser of the ALL FAN Control Control Your Control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale If the Control malfunctions or fails velocidad solamente Instrucciones d
6. e instalaci n 1 Coloque el control de velocidad del ventilador de cielo raso en la posici n de Alta Velocidad antes de instalar este control No cambie el ajuste de velocidad de su ventilador de cielo luego de tener instalado el control de velocidad puesto que podr a da ar su ventilador de cielo o el control All Fan 2 Verifique que el interruptor de pared del venti lador trabaja correctamente antes de la insta laci n Las conexiones incorrectas pueden da ar el control y anular n la garant a 3 Desconecte la energla el ctrica del ventilador de cielo raso en el panel el ctrico principal Retire el fusible o coloque el disyuntor en la posici n OFF apagado 4 Vea la ilustraci n que muestra la instalaci n de su control de velocidad All Fan Retire la placa de la pared para exponer los cables y desconecte el interruptor existente Si hay 4 alambres visibles conecte cada alam G within the warranty period due to a defect in material or workmanship we will replace it free of charge IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL THIS WAR RANTY AND ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN