Leviton R02-IPHS5-0LW Instructions / Assembly
Contents
1. receiver is connected e Consult the dealer or an experienced radio tv technician for help FCC CAUTION Any changes or modifications not expressly approved by Leviton Manufacturing Co Inc could void the user s authority to operate the equipment FOR CANADA ONLY For warranty information and or product returns residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department 165 Hymus Blvd Pointe Claire Quebec Canada H9R 1E9 or by telephone at 1 800 405 5320 DI 000 IPHS5 02A
2. time is set by manually turning ON the load fan with the push pad the device will provide continuous ON OFF time every hour The length of time that the device will remain ON is determined by the Time dial setting To set the device to operate in this mode A Manually turn the device OFF with the push pad if it is ON or wait for the device to time out automatically B Remove the face of the device to access the adjustment dials Refer to Section E on the front page of these instructions Rotate the Humidistat dial clockwise to the Cycle setting Rotate the Sensitivity dial to the OFF position Rotate the Time dial to the number 1 for the default time out of 10 minutes or to the number corresponding to the minimum desired length of time you wish the load fan to stay ON each time it cycles Re attach the face of the device Refer to Section E on the front page of these instructions Press the push pad to manually turn the load fan ON and set the initial ON time The device will cycle ON every hour after the initial ON time is set and remain ON for the length of time set with the Time dial NOTE pressing the push pad while the load fan is ON in this mode will manually turn OFF the load fan and deactivate the Air Cycle mode To re activate Air Cycle mode manually turn ON the load fan with the push pad which sets a new initial ON time Dials Sensitivity Low Med or High Modes of Operation Humidistat Auto ON Auto OFF OFF
3. Auto ON Auto OFF Between 20 and 80 W Humidity Set Points Low Med or High Air Cycle Cycle OFF MANUAL OPERATION At any time the device can be manually controlled with the push pad on the front of the device just below the Locator Light 1 Manual Operation in Auto ON Auto OFF Manual ON When manually turned ON with the push pad in this mode and unless the device enters automatic operation by detecting excess humidity thereafter the device will time out and turn OFF based on the time out setting If the device has been manually turned on and excess humidity is detected before the time out period has lapsed the device will override manual operation and assume control in automatic mode turning the load fan OFF after the humidity level declines to an acceptable level Manual OFF At any time the push pad can be pressed to manually turn the load fan OFF Manual Operation in Auto ON Auto OFF with humidity set points Manual ON When manually turned ON with the push pad in this mode and unless the device enters automatic operation by detecting excess humidity above the humidity set point thereafter the device will time out and turn OFF based on the time out setting If the device has been manually turned on and excess humidity is detected above the humidity set point before the time out period has lapsed the device will override manual operation and assume control in automatic mode turning the load fan OFF after the hu
4. SIDE WIRE Side wire terminals accept 14 12 AWG solid and stranded copper wire TO BACK WIRE Back wire openings use 14 12 AWG solid copper wire only 3 4 1 9 cm f 5 8 1 6 cm Wire aa Wire Paella E o e Make sure that the ends of the wires from the wall box are straight cut if necessary _f e Strip conductors 3 4 1 9 cm for side wire STZ applications or 5 8 1 6 cm for back wire applications Cut e Go to Step 4 for wiring instructions if necessary Bow Installation Terminal Screw Marked White WH Sensor Terminal Screw marked Black BK Ground Green Screw Terminal Screw marked LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date Leviton s only obligation is to correct such defects by repair or replacement at its option For details visit www leviton com or call 1 800 824 3005 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordan
5. ce with any labels or instructions There are no other or implied warranties of any kind including merchantability and fitness for a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warranty including merchantability and fitness for a particular purpose is limited to five years Leviton is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of any equipment lost sales or profits or delay or failure to perform this warranty obligation The remedies provided herein are the exclusive remedies under this warranty whether based on contract tort or otherwise Sensor Hot Black jot Blac de Line 120 VAC 60Hz Neutral White WIRING SENSOR Connect wires per WIRING DIAGRAM as follows Green or bare copper wire in wall box to Green terminal screw Line Hot wall box wire to terminal screw marked BK Load fan wall box wire to terminal screw marked RD Neutral wall box wire to terminal screw marked WH Proceed to Step 5 Testing your Device prior to Mounting in Wall Box NOTE Dress wires with a bend as shown in diagram in order to relieve stress when mounting device Position all wires to provide room in outlet wall box for device Ensure the word TOP is facing up on the device strap Partially screw in mounting screws in the wall b
6. decora WARNINGS AND CAUTIONS Single Pole Humidity Sensor and Fan Controller Cat No IPHS5 INDOOR USE ONLY 120VAC 60Hz Single Pole Only Incandescent 600W MLV Fluorescent 400VA LED CFL 150W Fan 1 6Hp INSTALLATION INSTRUCTIONS WARNINGS AND CAUTIONS LEVITON DI 000 IPHS5 02A TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING e Clean outer surface gently with damp cloth only DO NOT use soaps or cleaning liquids TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE DO NOT install to control a receptacle or a load in excess of the specified rating To be installed and or used in accordance with electrical codes and regulations If you are not sure about any part of these instructions consult an electrician A TOOLS NEEDED TO INSTALL YOUR DEVICE Slotted Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler B ff DESCRIPTION The IPHS5 is a humidity sensor and switch for control of bath fans and combination bath fan lights The IPHS5 detects changes in humidity for control of condensation in bathroom application or house ventilation It is compatible with bath fans rated at 1 6th HP and fan light combinations with single switched load e Compatible with Incandescent LED CFL and Fluorescent loads when used with combination fan amp light fixtures e Sensitivity adjustment e Built in countdown timer feature for manual operation e Aut
7. for the default time out of 10 minutes or to the number corresponding to the minimum desired length of time you wish the load fan to stay ON once it is turned on in any mode of operation Refer to Sensors Dials chart for available time out options E Re attach the face of the device Refer to Section E on the front page of these instructions 2 Automatic ON Automatic OFF Mode with humidity set points The device will automatically turn ON the load fan only upon detection of excess humidity above the minimum relative humidity set point A Remove the face of the device to access the adjustment dials Refer to Section E on the front page of these instructions B Rotate the Humidistat dial between 20 and 80 to set the minimum relative humidity set point C Rotate the Sensitivity dial to Hi Md or Lo Set to Hi in large rooms or to increase the sensitivity of the device Set to Md in mid sized rooms Set to Lo in small rooms or to minimize false activation Rotate the Time dial to the number 1 for the default time out of 10 minutes or to the number corresponding to the minimum desired length of time you wish the load fan to stay ON once it is turned on in any mode of operation Refer to Sensors Dials chart for available time out options E Re attach the face of the device Refer to Section E on the front page of these instructions 3 Air Cycle Mode Provides pre set ventilation ON time for meeting ventilation codes After the initial ON
8. midity level declines to an acceptable level Manual OFF At any time the push pad can be pressed to manually turn the load fan OFF Manual Operation in Air Cycle Mode Manual ON When manually turned ON with the push pad in this mode setting the initial ON time the device will time out and turn OFF based on the time out setting and continue to cycle ON every hour until it is shut OFF Manual OFF Pressing the push pad when the load fan is ON will disable the Air Cycle Mode until the load fan is manually turned back ON Step 6 Device Mounting TURN OFF POWER AT CIRCUIT BREAKER OR FUSE Installation may now be completed by tightening mounting screws into wall box Attach wallplate Restore Power Restore power at circuit breaker or fuse Installation is complete TROUBLESHOOTING Load fan does not turn ON in the presence of humidity e g after a shower e If the sensor is installed in a high humidity area it may be necessary to adjust the humidistat settings Load fan turns ON throughout the day e Change sensor s mode of operation to desired setting Load fan turns ON and OFF during a shower e This is normal operation for rooms with good ventilation NOTE DO NOT use to control a fan light combination where this is the only means of illumination NOTE The Leviton humidity sensor and fan control will not eliminate condensation and must be used with a properly sized ve
9. nt humidity threshold below which the load fan must be operated manually and or above which the load fan will be operated according to one of the automatic modes of operation 3 Cycle Only used in Air Cycle Mode SENSOR DIALS Sensitivity Or ate Stop Mark Time Humidistat 20 min 30 min 80 J Very 10 min 45 min NOTE DO NOT rotate the adjustment dials past the stop marks shown in the figure above LOCATOR LIGHT STATUS Locator Light Status Chart LED Status ON Fan load OFF OFF Fan load ON Blinking 2 sec ON 2 sec OFF Air Cycle Mode is active Blinking 2 sec ON 1 10 sec OFF Manual override 2014 Leviton Mfg Co Inc MODES OF OPERATION 1 Automatic ON Automatic OFF Factory Default Mode The device is pre set at the factory to turn ON the load fan when excess humidity is detected The load fan will turn OFF after the humidity level declines to an acceptable level and the time out has expired To set the device back to this factory default mode A Remove the face of the device to access the adjustment dials Refer to Section E on the front page of these instructions B Rotate the Humidistat dial counter clockwise to OFF C Rotate the Sensitivity dial to Hi default setting Set to Hi in large rooms or to increase the sensitivity of the device Set to Lo in small rooms or to minimize false activation Rotate the Time dial to the number 1
10. ntilation fan in an enclosed space For additional information contact Leviton s Techline at 1 800 824 3005 or visit Leviton s website at www leviton com FCC COMPLIANCE STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation of the device This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving Antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the
11. omatic ventilation air circulate mode for continuous operation with hourly pre set time outs B ff LOCATION MOUNTING For bathroom applications the device should be placed at a level to detect steam Placing the detector directly above a heater or near drafts is not recommended NOTE DO NOT use to control a fan light combination where this is the only means of illumination JE CHANGING THE COLOR OF YOUR DEVICE Your device may include color options To change color of the face proceed as follows Push down tabs per diagram one at a time and rotate forward to release Attach new face by inserting bottom hinge tabs then pivot and snap the color change kit to attach INSTALLING YOUR DEVICE NOTE Use check boxes v when Steps are completed WARNING TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring Identifying your wiring application most common NOTE If the wiring in the wall box does not resemble this configuration consult an electrician Single Pole 1 Line Hot 2 Neutral 3 Ground 4 Load e No user serviceable components DO NOT attempt to service or repair e Use this device WITH COPPER OR COPPER CLAD WIRE ONLY Step 3 Preparing and connecting wires This device can be wired using side wire terminal screws or back wire openings Choose appropriate wire stripping specifications accordingly TO
12. ox mounting holes Restore power at the circuit breaker or fuse The Locator LED in the center of the push pad should be illuminated and not blinking Refer to Locator Light Status Chart to confirm operational state of device Press and release push pad This will turn ON the load fan and activate the internal countdown timer The load fan will turn OFF after the set time out expires Press and release the push pad again to manually turn OFF the load fan DIAL SETTINGS With the power restored and the wallplate removed remove the face of the device to expose the setting controls see Color Change Kit removal on page 1 Use a small screwdriver to make adjustments to the device as required for the application Time factory default is 10 minutes 1 1 Adjust the time selector to set the time out duration which is the minimum desired length of time the load fan will remain ON after being turned on in any mode of operation 2 Refer to Sensors Dials chart for available time period options 3 For use with all three Automatic Modes of Operation Sensitivity To reduce false activation reduce sensitivity 1 Hi Default Setting 2 Medium 3 Low 4 OFF used in Air Cycle mode Humidistat factory default is OFF off 1 OFF device ignores the humidity set point and controls load fan based on detection of excess humidity 2 Minimum relative humidity set point may be set between 20 and 80 sets the ambie