1. AcuityBrands Company Consumer Products Acuity Lighting Group Inc One Lithonia Way Conyers GA 30012 www lightahome com www lithonia com Page 6 VA LITHONIA LIGHTING INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION DIRECTIVES D INSTALLATION Crenelle Flush Mount Fixture 1 22W amp 1 32W 4100K T9 CirclineLamps Rasante L mparas Circular T9 4100K 1 22W amp 1 32W Affleur Lampes Circline T9 4100K 1 22W amp 1 32W Model Number N mero de Modelo Num ro des mod les 10512 Register your warranty on www lightahome com warranty Your prompt product registration confirms your right to the protection available under the terms and conditions of your Lithonia Lighting warranty Standard Ono Year Warranty applies to nonnergy Star rated or nonock items only Visit lightahome com to find complementary fixtures and much more e Customer Support Our Complete Product Catalog Product Instruction Sheets Energy Saving Tips Product Specifications Glossary of Lighting Terms Prot jase Antes de instalar lea estas Pour votre propre protection Avant de proc der Pinstallation veuillez lire attentivement ces directives et les conserver pour r f rence ult rieure Date de l installation Protect yourself Before installing read these instructions carefully and instrucciones cuidadosamente save them for future reference y gu rdelas para futura referencia Date
2. correctamente en el enchufe Reemplace la s l mpara s defectiva s m Verifique que el luminario este alambrado apropiadamente Verifique que el luminario este conectado tierra correctamente a El voltaje de la l nea en el luminario este correcto COMO LIMPIAR EL ACRILICO Para mayor resultado difusor de acrilico se debe lavar con jabon o detergents suaves Enjuague con agua y deje secar al aire Si requere ayuda adicional contacte Consumer ProductsTechnical Supportal 800 748 5070 Reemplazo del alastro tiene que ser hecho por un electricista calificado regado o polvos virutas de acero o papel abrasivo Para disponibilidad de piezas de repuesto p ngase en MLIGHTAHOME com Aprenda a iluminar su hogar como un profesional Page 5
3. de los tornillos anteriormente instalados en la caja de alambres levante el luminario g relo hacia su izquierda y apriete tornillos para asegurar el Ensamblaje de la Carcasa contra el techo Con puntas el ctricas en la L mpara 5 frente al enchufe inserte la l mpara en el Enchufe 6 y g rela suavemente en el sentido horario PRECAUCION El tap n en la s lampara s circular es estan dise adas para rotar libremente dentro de loslimites mecanicos 8 Si a s l mpara s son proporcionadas pero no estan instaladas enchufe los conectores de fuente de suministro el ctrico al recept culo suministro el ctrico de la l mpara Comenzar la instalaci n con la l mpara m s peque a luminaria de dos l mparas colocando la l mpara sobre dos de los tres clips sujetadores de lal mpara 3 Empuje suavemente la l mpara sobre el tercer sujetador mientras retrocede el sujetador ligeramente Repita el proceso con la segunda l mpara 9 Introduzca el borde superior del difusor entre el borde de la luminaria y la Aldaba sujetador del difusor 9 gire el difusor hacia arriba y empuje el clip sujetador del difusor hacia adentro como se encontr por el difusor du rante la instalaci n Gu a de Localizaci n de Aver as Si este luminario falla de operar apropiadamente use la siguiente gu a para diagnosticar y corregir el problema Verifique que la L mpara usada es la correcta m Asegure que la l mpara este asentada
4. debe ser instalada seg n c digos del NEC y locales de construcci n ADVERTENCIA E RIESGO DE DESCARGA ELECTRICA La corriente el ctrica de su casa puede causarle una descarga el ctrica dolorosa o una lesi n seria a menos que se use adecuadamente Para su seguridad siempre recuerde lo siguiente Desconecte la corriente el ctrica en la caja de fusibles o de cortacircuito antes de instalar la luminaria Desconecte la corriente el ctrica cada vez que cambie las l mparas O para darle mantenimiento en el futuro Conecte a tierra la luminaria para evitar posible descarga el ctrica y asegurar que funcione aecuadamente Revise dos veces todas las conexiones para asegurarse que est n bien apretadas y correctamente instaladas Esta luminaria est dise ada para ser usada en un circuito protegido por un fusi ble o cortacircuitos e instalada de acuerdo con los c digos de electricidad locales Si no est seguro de su alambrado consulte con un electricista calificado o al inspector de electricidad local y verifique su c digo de electricidad local ADVERTENCIA RIESGO DE LESION Algnas partes de metal de esta luminaria pueden tener bordes muy afilados Para prevenir cortaduras y raspaduras use guantes al instalar las piezas e Recoja todas las piezas peque as sobrantes y destruyalas junto con el material de embalaje ya que stos pueden ser peligrosos a los ni os PRECAUCI N RIESGO DE FUEGO Conduc
5. est con ue de fa on bouger librement l int rieur des limites m caniques Ne pas forcer par del ces points 8 R tablir le courant lectrique au fusible ou au disjoncteur et v rifier si l installation est r ussie 9 Faire basculer l extr mit des fermoirs 9 vers l ext rieur de l appareil placer la bride du diffuseur dans le bo tier de l appareil puis basculer les fermoirs vers l int rieur afin de saisir le diffuseur Guide de d pannage Si l appareil ne fonctionne pas ad quatement veuillez vous servir du guide ci dessous afin d identifier et corriger le probl me Vous assurer qu une lampe ad quate est employ e Vous assurer que la lampe est bien install e dans la douille Remplacer toute lampe d fectueuse V rifier si le c blage de l appareil est bien fait V rifier si la mise la terre de l appareil est ad quate V rifier la tension de secteur de l appareil Le remplacement du ballast doit tre effectu par un lectricien comp tent Pour toute autre assistance veuillez contacter nos services de support technique Consumer Products Technical Support 800 748 5070 Nettoyer l aide d un linge doux Nettoyer le diffuseur avec un savon doux et de l eau Ne pas utiliser de produits abrasifs tels les tampons ou poudres r curer la laine d acier ou les papiers abrasifs ALIGHTAHOME com Apprenez clairer votre int rieur comme un pro VA LITHONIA LIGHTING An
6. fuse or circuit breaker box 2 With the power turned off thread two Screws 1 into junction box Note screws must be the same distance apart as keyholes in back of housing assembly Assistance may be required to support fixture during installa tion 3 Hold the fixture Housing Assembly 3 firmly and connect the green ground wire from the fixture to the bare copper ground wire from the junction box using a Wirenut 2 f house wiring does not include a ground wire consult your local electrical code for approved grounding methods FOR PROPER CONNECTION PLACE WIRENUT OVER WIRES TWIST CLOCKWISE UNTIL TIGHT 4 Use Wirenuts 2 to connect black fixture wire to the black power supply wire and white fixture wire to the white power supply wire Tuck wires into junction box 5 Hold Housing Assembly in one hand and with the other hand position wires up and into outlet box 6 Align keyholes on back of Housing Assembly with screws previously installed in junction box Lift fixture up rotate clockwise and tighten screws to secure Housing Assembly against ceiling 7 If Lamp s are provided but not installed plug power connectors into the Lamp power receptacles Begin installation with the smallest Lamp 4 by positioning lamp over two of the three Lamp Clips 5 Gently push the lamp over the third clip while pulling the clip back slightly Repeat the process with the second Lamp 6 CAUTION The Lamp power receptacle is de
7. qualified electrician or local electrical inspector and check your local electrical code WARNING RISK OF INJURY Some metal parts in the fixture may have sharp edges To prevent cuts and scrapes wear gloves when handling the parts Account for small parts and destroy packing material as these may be hazardous to children CAUTION RISK OF FIRE Minimum 90 C supply conductors LAMP CONTAINS MERCURY Hg LA LAMPE CONTIENT DU MERCURE L MPARA CONTIENE MERCURIO Manage in Accordance with Disposal Laws En disposer conform ment aux lois sur l limination de d chets Maneje de Acuerdo con las Leyes de Deshace www lamprecycle org or call1 800 748 5070 DE SEGURIDAD El montaje no se puede utilizar con reductor de intensidad de luz sensor de movimiento fotocelula u otro dispositive de conmutacion electrrico a menos que se especifique lo contrario Este luminario esta dise ado para uso al interior SOLAMENTE y no debe ser utilizado en reas con ventilaci n limitada ni temperaturas altas Luminario debe ser conectado a una fuente el ctrica nominal de 120 Voltios 60 Hz Cualquier otra conexi n invalidara la garant a Siempre utilice el mismo vataje y el tipo de l mpara incluida o specificada para el luminario Incumplimiento invalidara la garant a Este luminario esta destinado para ser conectado a una caja de ensambladura no proporcionada correctamente instalada listada UL puesta a tierra y
8. IMPORTANT SAFETY INFORMACI N IMPORTANTE IMPORTANTES MESURES INSTRUCTIONS e Fixture cannot be used with a dimmer switch motion sensor photocell or other electronic switching device unless other wise designated e This fixture is designed for indoor use ONLY and should not be used in areas with limited ventilation or high ambient temperatures e Fixture must be connected to a nominal 120Volt 60 Hz power source Any other connection voids warranty Always use the same wattage and type of lamp included or specified for the fixture Failure to do so will void warranty e This fixture is intended to be connected to a properly installed and grounded UL listed junction box not provided and should be installed according to NEC and local building codes WARNING RISK OF SHOCK Electric current can cause painful shock or serious injury unless handled properly For your safety always Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the power when you change lamps or perform other maintenance Ground the fixture to avoid potential electric shocks and to ensure reliable starting Double check all connections to be sure they are tight and correct This fixture is designed for use in a circuit protected by a fuse or circuit breaker and to be installed in accordance with national and local electrical codes lf you are unsure about your wiring consult a
9. Installed Fecha Instalada Page 1 U212125T 7 10 FIXTURE PARTS LIST Description Quantity 1 Screws 2 Wirenuts 3 Housing Assembly 4 22W Lamp Lamp Clip 32W Lamp Diffuser Ballast 9 Diffuser Latc Contained in Part Packs 5 6 7 8 po 20 20m Lamps amp Mounting Hardware Included LISTA DE EMBALAJE Descripci 1 Tornillos pa 2 Capuchones de 3 3 Ennsamblaje de la Carcasa dl 4 L mpara de 22W A 5 Grapa de la L mpara 6 6 L mpara de 32W EA 7 Difusor iA 8 Balastro Es 3 9 Aldaba del Difusor Contenido en el Paquete de Piezas L mparas y Herraje para Montaje Incluidas LISTE DES PIECES Description Quantit 1 Vis 2 Capuchons de connexion 3 Bo tier de l appareil 4 Lampe de 22 W 5 Agrafes de lampe 6 Lampe de 32W 7 Diffuseur 8 9 Fermoir du diffuseur Compris dans les sacs d emballage valo Lampes et Quincaillerie de Montage Incluses REQUIRED TOOLS HERRAMIENTAS REQUERIDAS OUTILS REQUIS D a So 9 Diffuser Latch 2 Wirenuts 5 Lamp Clip 8 Ballast Figure 2 STEP BY STEP GUIDE 1 Remove fixture components and parts pack s Check that all parts are included See page 2 WIRING AND FIXTURE OPERATION CAUTION Connect fixture to supply wires rated for at least 90 C 194 F Do not use fixture on dimming circuits NOTE Turn off power at
10. MINARIO Y EL ALAMBRADO Conecte el luminario a alambres de suministros que est n clasificados a por lo menos 90 C 194 F No use el luminario en circuitos con atenuador de intensidad NOTA Apague la electricidad en la caja de cortacircuitos 2 Con la electricidad apagada rosque dos Tornillos 1 en la caja de ensambladura Nota los tornillos deben estar a la misma distancia aparte que las bocallaves en la parte trasera del ensamblaje de la carcasa Sostenga el ensamblaje de la Carcasa del luminario 3 firmemente y conecte el alambre verde de conexi n a tierra del luminario al alambre de cobre descubierto de conexi n a tierra de la caja de ensambladura usando una Tuerca de Alambre 2 Si el alambrado de la casa no incluye un alambre de conexi n a tierra consulte su c digo el ctrico local para m todos aprobados de hacer tierra PARA UNA CONEXI N APROPIADA COLOQUE EL CAPUCH N DE ALAMBRES SOBRE LOS ALAMBRES GIRE HACIA SU DERECHA HASTA QUE QUEDE APRETADO Use Capuchones de Alambres 2 para conectar el alambre negro del luminario al alambre negro de suministro de electricidad y el alambre blanco del luminario al alambre blanco de suministro de electricidad Meta los alambres en la caja de ensambladura Sostenga el Ensamblaje de la Carcasa con una mano y con la otra estire los cables dentro del la caja de conexiones Alinee los keyholes en el Ensamblaje de la Carcasa sobre las cabezas
11. d quates et solides Cet appareil est destin un circuit d ali mentation prot g par un fusible ou un dis joncteur Il doit tre install selon le code de l lectricit applicable En cas de dou tes faire appel un lectricien ou un ins pecteur en lectricit et v rifier le code de l lectricit en vigueur AVERTISSEMENT DANGER DE COUPURES Certaines pi ces de m tal pourraient pr senter des rebords coupants pour viter toute blessure porter des gants lorsqu on manipule le luminaire Garder les petites pi ces hors de la port e des enfants et d truire le mat riel d emballage MISE EN GARDE RISQUE D INCENDIE Les fils d alimentation doivent convener pour 90 C GUIDE D TAILL 1 Retirer les composants de l appareil et tout sac de pi ces fourni S assurer que toutes les pi ces sont comprises Voir la page 2 MISE EN GARDE SUR LE C BLAGE ET LE MODE D EMPLOI DE L APPAREIL Connecter l appareil des fils d alimentation calibr s pour au moins 90 C 194 F Ne pas utiliser cet appareil sur un circuit de gradation de l clairage NOTE Couper l alimentation au disjoncteur du circuit lectrique De l aide pourrait tre n cessaire pour supporter l appareil pendant l installation 2 L alimentation lectrique coup e visser deux vis 1 dans la bo te de jonction note les vis doivent tre loign es l une de l autre la m me distance que les fentes en trou d
12. e serrure l arri re du bloc bo tier 3 Tenir solidement le bloc bo tier 3 et connecter le fil vert de mise la terre de l appareil au fil de cuivre nu de mise la terre de la bo te de jonction l aide d un capuchon de connexion 2 Si le c blage d alimentation ne comprend pas de fil de mise la terre consulter votre code d lectricit local et v rifier la m thode d installation conforme 4 Utiliser des capuchons de connexion 2 pour connecter le fil noir de l appareil au fil d alimentation noir et le fil blanc de l appareil au fil d alimentation blanc Ranger les fils dans la bo te de jonction 5 Tenir le bloc bo tier d une main et de l autre placer les fils dans la bo te de raccordement 6 Aligner les fentes en trou de serrure du bloc bo tier de l appareil sur les t tes de vis d j install es dans la bo te de jonction soulever l appareil le tourner dans le sens oppos aux aiguilles d une montre et serrer les vis pour fixer solidement le bloc bo tier au plafond 7 Si les lampes sont fournies mais non install es brancher les connecteurs dans la douille d alimentation des lampes D buter l installation par la plus petite lampe pour les mod les 2 lampes Placer au dessus de 2 des 3 pinces lampe 6 Pousser doucement la lampe sur la troisi me pince tout en tirant l g rement la pince vers l arri re R p ter pourla seconde lampe Mise en garde La prise des lampes circline
13. signed to rotate freely within the limits of mechanical stops Do not force beyond the limits of easy movement or the lamp may fail to operate 8 Turn on electricity at fuse or circuit breaker box and verify success of installation 9 Pivot end of Diffuser Latches 9 outward away from fixture housing position diffuser flange inside fixture housing pivot Latches inward to captivate diffuser Trouble Shooting Guide If this fixture fails to operate properly use the guide below to diagnose and correct the problem Verify that correct lamp is used Make sure lamp is properly seated in socket Replace defective lamp s Verify that fixture is wired properly Verify that fixture is grounded correctly The line voltage at the fixture is correct To replace Ballast Ballast replacement if required to be completed by a qualified electrician If further assistance is required contact Consumer Products Technical Support at 800 748 5070 Cleaning Diffuser For best results diffusers should be washed with soap or mild detergent Rinse with clear wa ter and allow to air dry For availability of replacement parts contact Technical Support or visit A LIGHTAHOME com Learn to light your home like a pro LIGHTAHOME com Page 4 GU A DE PASO A PASO 1 Remueva los componentes del luminario y paquete s de pieza s Asegure que todas las piezas est n incluidas Vea la Pagina 2 CUIDADO DE LA OPERACI N DEL LU
14. tores de suministrode m nimo de 90 C Page 3 DE S CURIT Cette fixation nest pas compatible avec les dispositifs de gradation les capteurs de mouvement les photocellules ni tout autre dispositif lectronique a commuta tion sauf indication contraire e Cet appareil est con u pour un usage l int rieur SEULEMENT et ne doit pas tre utilis dans un lieu mal a r ou soumis une temp rature ambiante lev e L appareil doit tre connect une tension d alimentation nominale de 120 V 60 Hz e Toujours employer une lampe du m me type et de la m me puissance que celle incluse ou sp cifi e pour l appareil d faut de quoi la garantie sera annul e e Cet appareil est pr vu pour un raccordement une bo te de jonction homologu e UL non fournie install e correctement avec mise la terre et doit tre install conform ment aux codes du b timent locaux et NEC AVERTISSEMENT DANGER DE CHOC ELECTRIQUE Afin d viter les blessures caus es par une d charge lectrique il faut prendre les pr cautions suivantes avant d installer un lu minaire Couper le courant au bo tier disjoncteurs ou fusibles avant l installation Toujours couper le courant pour le changement des lampes ou l entretien Effectuer la mise la terre du luminaire pour viter tout choc lectrique ventuel et assurer Pallumage Toujours v rifier les connexions afin qu elles soient a