Home

Dale Tiffany SGH11173 Instructions / Assembly

image

Contents

1. 5 SPRINGDALE ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires O The insulation on any of the wires must not be damaged during a installation No rough or sharp edges are in contact with any of the wires S G H 1 1 1 7 3 Fixture wires are connected to the proper house supply wires Un We recommend professional installation by a licensed electrician Do not use light bulb s with wattage greater than those APX WT 26 LBS specified for this fixture Power is off when installing light Listed bulb s into the fixture Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended O Read directions and follow steps 1 14 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Ceiling Outlet Box with Ceiling Screws 4 attach Threaded Rod 5 to Crossbar 3 Screw Nut 6 and Loop 7 to Threaded Rod 5 6 4 Raise Canopy 8 and tighten Loop Collar 9 connect fixture ra 7 chain 10 to the loop with desire length of chain 11 12 5 After connecting chain lo
2. SGH11173 bo Columna Central ADVERTENCIAS PARA EVITAR EL RIESGO DE DESCARGA 4 ELECTRICA ASEGURESE DE APAGAR LA ELECTRICIDAD 7 y aro Decor DURANTE LA INSTALACI N O SERVICIO DE ESTE APARATO j 9 Cuelgue la cadena del dosel superior al anillo de enganche del dosel inferior Asamblea de 10 Atornille la asamblea de la portal mpara a la columna central Portal mpara 11 Atornille la tuerca roscada a la asamblea de la portal mpara 12 Coloque la pantalla con el tapon sobre la tuerca roscada y apriete el remate A asegurando la pantalla en su lugar 13 Cuelgue los brazos decorativos del dosel inferior a los ganchos de la pantalla 14 Inserte bulbos en el z calo Tuerca Roscada Gancho de la pantalla Pantalla Remate Usars 6 maximo 40 Vatios Tipo B Bulbos Bulbosino incltdios Temas B y C estan conectados LISTA DE COMPONENTS Dise o Componentes Cantidad 701 40 1 pieza 1 pieza 1050 14 1 pieza 16 1 pieza 20 conjuntos 18 1pieza 24 1 pieza 1080 26 28 piezas 1080 20 56 piezas 1080 18 28 piezas 28 conjuntos 1080 16 112 piezas 1080 14 56 piezas PIEZAS DE REPUESTO Revision 09 01 11 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE LAS PIEZAS Made in China Hecho en China ANTES DE LA ASAMBLEA
3. y la espiga roscada Conectar las cables del suministra el ctrico a los cables de la lampara utilizando los conectores de cable 17 Vea por favor conexi n procedimientos abajo I Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 17 Rosque el conector en direcci n de las manecillas del reloj hasta que sienta firmeza 3 4 5 6 Il Conecte el cable estriado negativo de la l mpara con j gt 47 el cable de suministro blanco de la caja de distribuci n Y Conector de cables de la misma forma 111 Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar y apretar el conector firme a los cables IV Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos Envolviendo hasta una pulgada de largo los cables incluyendo el conectores V Si la caja el ctrica provee de cable de tierra color verde o color cobre conectrar el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando todos los cables y conectores 7 Asegure la base atornillando el enganche del anillo al anillo 8 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara A gt l SN
4. RINGDALE SGH11173 iy Center Column WARNING TO AVOID RISK OF ELECTRICAL SHOCK A N Decorative Arm BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE Socket Assembly 9 Attach chain from upper canopy to loop collar of the lower canopy 10 Screw socket assembly to the column 11 Screw threaded rod into socket assembly 12 Place shade with shade cap over the end of the threaded rod and tighten finial to secure shade in place 13 Attach decorative arms from lower canopy to shade hooks 14 Insert bulbs into the bulb sockets Threaded Rod PURPOSES L PACKAGING TO MINIMIZE DAMAGE Uses 6 maximum 40Watt Type A Bulbs Bulbs not included Components B and C are pre attached COMPONENT LIST Components 701 40 1 pc 1050 14 1 pc 16 1 pc 18 1 pc 24 1 pc 1080 26 28 pcs 20 56 pcs 18 28 pcs 16 112 pcs 14 56 pcs SPARE PARTS Revision 09 01 11 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China 5 SPRINGDALE H T INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes Se debe desconectar la alimentaci n en la caja de fusibles antes de instalar esta l mpara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro que lleven corriente Ninguno de los cables deb
5. e sufrir da o en el aislamiento durante la instalaci n No debe haber bordos rugosos o filosos en contacto a SGH11173 neS F y Los cables de la l mpara se deben conectar a los cables aproximada 26 libras de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado No utilice bombillas de un vataje mayor al especificado de P de las bombillas para esta l mpara El suministro debe O Lea las instrucciones y siga los pasos 1 14 estar cortado durante la instalaci n en la l mpara Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener 2 Desempaquete y presente cuidadosamente las piezas el peso de la l mpara El uso de una abazadera de montage a las indicaciones de la ilustraci n es recomendado Seguir los pasos en el diagrama atornille la abrazadera 3 a la caja el ctrica con los tornillos 4 colocar el espiga roscada 5 To a la abrazadera de montage 3 Colocar la tuerca 6 y el enganche de anillo 7 a la espiga 5 Levantar la base 8 para apretar el enganche de anillo 9 conectar la cadena de la l mpara 10 al enganche de anillo colocando la cadena al tama o que se desea 11 12 Despues de conectar la cadena suelta al enganche de anillo 9 y bajar la base 8 sobre la cadena Colocar las cables de la l mpara 13 atraves de la cadena elenganche de anillo la base el otro enganche de anillo
6. osen Loop Collar 9 and lower 2 Canopy 8 over chain 6 Thread Fixture Wires 13 through Chain pass Loop Collar an Canopy Loop and Threaded Rod Connect Supply Wire ow with Fixture Wire using Wire Nut Connectors 17 2 A Please see connection procedures below G Black supply wire with wire nut connector 17 Screw the connector clockwise until you feel a firmness II Connect the negative ribbed wire from the fixture to the white supply wire from the outlet box in the same manner 0 Y drabh Ill Try gently to pull the connector off the wires If you can pull Y S the connector off carefully re do the step above and check again s k for a firm connection E IV Separately wrap the wires connections using electrical tape one inch below and include the connector V If your outlet box is provided with a grounding wire green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Ceiling Outlet Box 7 Secure Canopy by screwing Loop Collar onto Loop 8 Follow Diagram on back side for fixture assembly instructions Po I Connect the positive smooth wire of the fixture with f A Of r A Conector Upper Canopy H T I N 5 SP

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - ADFWeb.com  Schneider Slider Edge  取扱説明書 SO903i    OPERATING INSTRUCTIONS MANUAL    

Copyright © All rights reserved.
Failed to retrieve file