1. 7 from the O outlet box 4 11 Fix the wire nut connector 6 over the ends of two wires and screw the connector clockwise until you feel a firmness 111 Try gently to pull the connector off the wires If you can pull the connector off carefully re do the step above and check again for a firm connection IV Connect the negative ribbed wire from the fixture to the white supply wire 8 from the outlet box 4 in the same manner V Separately wrap the wire connections using electrical tape one inch before and include the connector VI If your outlet box is provided with a grounding wire 9 green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw TAT and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Wall Outlet Box 5 Mount Fixture 10 to Crossbar and secure using Decorative Knobs 11 6 Follow Diagram on back side to attach Crystal Components A E SPRINGDALE H T I N SGH11135 WARNING TO AVOID RISK OF ELECTRICAL SHOCK BE SURE TO SHUT OFF POWER WHILE INSTALLING OR SERVICING THIS FIXTURE 7 Using the crossbar screws provided attach the plate A to the crossbar 8 Place fixture D onto plate A using decorative knobs E 9 Place sleeve cover C over sockets 10 Insta
2. o color cobre solamente conectrar el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando todos los cables y conectores o 5 Monte l mpara 10 a la abrazadera y segure usando las perillas decortivas 11 6 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara Pa Fa azar Paras E SPRINGDALE H T I N SGH11135 ADVERTENCIAS PARA EVITAR EL RIESGO DE DESCARGA ELECTRICA ASEGURESE DE APAGAR LA ELECTRICIDAD DURANTE LA INSTALACION O SERVICIO DE ESTE APARATO 7 Utilizando los torniHos de la abrazadera proporcionado conecte la placa de la abrazadera A 8 Coloque el l mpara D sobre la placa A y asegure con las tapas de tornillos E 9 Coloque la manga de candela C sobre el Z calo 10 Instale los bulbos en el z calo Usar maximo 2 40 vatios Tipo B Bulbos Bulbos no incluidos LISTA DE COMPONENTS C Manga de 2 piezas Candela PIEZAS DE REPUESTO op Revision 10 04 11 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE PIEZAS ANTES DE LA ASAMBLEA Made in China Hecho en China
3. E SPRINGDALE G H T ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires The insulation on any of the wires must not be damaged during installation No rough or sharp edges are in contact with any of the wires Fixture wires are connected to the proper house supply wires We recommend professional installation by a licensed electrician Do not use light bulb s with wattage greater than those specified for this fixture Power is off when installing light S G fe 1 1 1 3 5 bulb s into the fixture APX WT 5 LB Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended 2 WARNING 1 Read directions and follow steps 1 10 VN dee Electrical Danger Turn Power Off 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Wall Outlet Box 4 with appropriate Screws 5 a Screws not provided OT _ 4 Connect Supply Wire with Fixture Wire using oe Wire Nut Connectors 6 Please see connection procedures below R 1 Place the positive smooth wire from fixture 7 evenly against with Black supply wire
4. ciones y siga los pasos 1 10 2 Desempaquete y presente cuidadosamente las piezas a las indicaciones de la ilustraci n y lea las instrucciones 2 Rees antes de comenzar 3 Seguir los pasos en el diagrama Atornille la abrazadera 3 a la a caja el ctrica 4 con sus tornillos 5 los tornillos no estan inclui riesgo el ctrico ig gimentacion 4 Conecte alambre de suministro con alambre de instalaci n usand conectores de tuerca de alambre 6 Vea por favor conexi n procedimientos abajo 1 Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 7 de la caja el ctrica 4 11 Fije el conector de tuerca de alambre 6 sobre las puntas de los dos alambres y rosque el conector en direcci n de las ma necillas del reloj hasta que sienta firmeza 111 Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar y apretar el conector firme a los cables IV Conecte el cable estriado negativo de la l mpara con el cable de suministro blanco 8 de la caja el ctrica 4 de distribuci n de la misma forma V Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos Envolviendo hasta una pulgada de largo los cables incluyendo el conectores VI Si la caja el ctrica provee de cable de tierra 9 color verde
5. ll bulbs in the bulb socket FOR RETURN SHIPPING PURPOSES PLEASE RETAIN ORIGINAL PACKAGING TO Uses Maximum 2 40Watt Type B Bulbs MINIMIZE DAMAGE l Bulbs not included COMPONENT LIST Designa Component Qty SPARE PARTS o o Revision 10 04 11 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China SPRINGDALE INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes Se debe desconectar la alimentaci n en la caja de fusibles antes de instalar esta l mpara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro que lleven corriente C Ninguno de los cables debe sufrir da o en el aislamiento durante la instalaci n 1 1 1 Listed No debe haber bordos rugosos o filosos en contacto con alguno de los cables Los cables de la l mpara se deben conectar a los cables de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado No utilice bombillas de un vataje mayor al especificado de las bombillas para esta l mpara El suministro debe estar cortado durante la instalaci n en la l mpara Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener el peso de la l mpara El uso de una abrazadera de montage es recomendado aproximada 5 libras Q Lea las instruc