1. Installation And Safety Instructions HC 362 Saq Gull Lighting Line art shown may not exactly match the fixture enclosed However the installation instructions do apply to this fixture Fill in Item Number on Carton and File This Sheet For Future Reference ITEM ___ 123098 FOR YOUR SAFETY ASSEMBLY WARNING BE SURE THE ELECTRICITY TO THE WIRES YOU ARE Carefully remove the fixture from the carton and check that all parts WORKING ON IS SHUT OFF EITHER THE FUSE IS REMOVED OR are included as shown in Figures 1 and 2 Be careful not to misplace THE CIRCUIT BREAKER SET AT OFF any of the screws or parts which are needed to install this fixture GENERAL STEP 1 You don t need special tools to install this fixture Be sure to follow the Attach fixture loop H to top plate J if applicable steps in the order given Under no circumstances should a fixture be hung on house electrical wires nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system Read instructions carefully If you are unclear as to how to proceed consult a qualified electrician OUTLET BOX GROUNDING AND MOUNTING BAR LOCK UP GROUND WIRE PE WIRE CONNECTOR GROUND WIRE A OUTLET BOX SCREWS NUT B NIPPLE C lt GROUND WIRE M MOUNTING lt lt SCREW COLLAR E k iji A oX AN SCREWS lt CANOPY G GREEN GROUNDING Faaa TOP lt SCREW COLLAR RING F AC RENAN onan P FIGURE 2
2. ND amp SMOOTH PARALLEL WIRE SQUARE amp RIDGED WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER ee a ee BROWN GOLD OR BLACK WITHOUT TRACER BROWN GOLD OR BLACK WITH TRACER nee Note When parallel wire is used the tracer wire is square shaped or ridged and less tracer wire is round in shape or smooth Seen best when viewed from wire end To separate wires grasp the ends of each wire and pull apart B Take your fixture wire s from group A and place evenly against the black wire from the outlet box DO NOT twist wires together before using wire connectors C Fit a wire connector not supplied over the wires and screw the connector clockwise until you feel a firmness D Try gently to pull the connector off the wires If you can pull the connector off carefully re do steps B and C as above and check again for a firm connection E Connect the fixture wire from group B to the white wire from the outlet box in the same manner STEP 6 GROUNDING INSTRUCTIONS The green grounding screw D is to be inserted into the hole with two raised dimples provided on the mounting bar A Wrap the ground wire M from the fixture if supplied and the ground wire from the outlet box bare metal or green insulated wire around the green grounding screw D on the mounting bar A If uninsulated wire is on the mounting bar A connect the ground wire M from the fixture if Supplied and the outlet box to i
3. Wy NOT INCLUDED A FIXTURE LOOP H 1 la Sp lt TOP PLATE J r WZ DHII lt suPPonRT ARM Y RUBBER SUPPORT WASHER L i H J J SLAs 0 METAL WASHER Z FIGURE 1 NOT INCLUDED BALL NUT M INSTALLATION HC 362 IMPORTANT DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET OX us STEP 1 Secure mounting bar A to outlet box with outlet box screws not supplied Thread nut B on nipple C so that three threads are exposed above nut B Thread nipple C into mounting bar A and secure with nut B Attach screw collar E to nipple C STEP 2 Using two pairs of pliers open one link of chain P and connect it to the fixture loop H at the top of the fixture STEP 3 Slide the screw collar ring F and canopy G in that order over chain P Open one link on the other end of the chain P and attach it to the screw collar E which has been mounted to the ceiling nipple C BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY STEP 4 Lace wires up through chain P and pass wires through holes in screw collar E We recommend lacing wire up through every other link of chain P STEP 5 A Take note of the color of the wire s on your fixture Identify which group your fixture wire s falls into and connect the wires according to the directions below F GROUP A CONNECT TO BLACK GROUP B CONNECT TO WHITE HOUSE WIRE HOUSE WIRE BLACK WHITE cmm PARALLEL WIRE ROU
4. t using a small wire connector not supplied NOTE Underwriters Laboratories U L does not require all fixtures to have ground wires These fixtures still meet all U L specifications The listing mark of Underwriters on the product identifies products manu factured under its listing and Follow Up Service Programs NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES FINAL ASSEMBLY Make sure no bare wires can be seen outside wire connectors STEP 1 After wires are connected tuck them carefully inside outlet box Raise canopy G against ceiling and screw the screw collar ring F to the screw collar E STEP 2 Install lamps STEP 3 On support arm Y place rubber support washer L glass diffuser O metal washer Z and secure with ball nut M CLEANING To clean wipe fixture body with a soft cloth Clean glass with a mild soap Do not use abrasive materials such as scouring pads or powders steel wool or abrasive paper ORDERING PARTS Keep this sheet for future reference and in case you need to order replacement parts All parts for this fixture can be ordered from place of purchase Be sure to use exact wording from illustration when ordering parts
Download Pdf Manuals
Related Search
Related Contents
URGENTE: AVISO DE SEGURANÇA Infineon C164CM, C164SM User`s Manual Watlow de Samsung 70" LCD Touch SyncMaster 700TSN-2 LH70TCSMBG/EN Bruksanvisning User definable co User Manual - OMEGA Engineering Beurteilung von Bremsbelagausbrüchen 全文[PDF: 765KB] NETTOYEUR HAUTE PRESSION MAC 120 XTRA - Réf Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file