Home
Heath Zenith SL-6015-WH5 Instructions / Assembly
Contents
1. N Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage Adjusting Indoor Motion Sensor Coverage gt Aim Sensor Down Aim Sensor Higher for Short Coverage for Long Coverage Adjusting Outdoor Motion Sensor Coverage 598 1135 10 ADD A SWITCH Installation 1 Remove Tab from Battery Chamber Remove cover from front of Add A Switch transmitter Gently pull tab out of battery chamber Slide cover onto Add A Switch transmitter a DE o f 77 Battery Chamber Type CR2032 Access Door Removing Battery Tab 2 Selectmounting location foradd a switch transmitter Note Trans mitter should be located within 100 feet 30 m of receiver Note Transmitter should be mounted approximately 4 feet from the floor and in the vertical position 3 Before mounting hold transmitter in selected location and verify operation see Operation Note If transmitter does not operate correctly see Troubleshooting Guide 4 With transmitter held in place mark the mounting holes with a pencil or pointed object 5 Remove transmitter and drill two 3 16 holes Tap drywall anchors provided into holes with a hammer 6 Attach transmitter to wall using two screws provided Operation 1 Verify that receiver has been properly installed See Receiver Information page 10 2 Push the ON top button and release The light should turn on full bright 3 Push the OFF bottom button an
2. Tornillo de montaje Tuerca Tornillo de la abrazadera Montura giratoria de bola m y gt zZ je Detector Instalaci n del detector de movimiento Continuaci n 598 1135 10 19 Detector de movimiento para uso exterior Control de y DURACI N A as s or pal aS Indicador gt LED Control de alcance zm CE rA eA Rasan Detector de movimiento para uso interior Controles del detector de movimiento 150 ngulo m ximo de cobertura Alcance m ximo rea de cobertura del detector de movimiento para uso interior ath 24m D 21m Alcance m ximo ngulo m ximo de cobertura rea de cobertura del detector de movimiento para uso exterior Movimiento Movimiento Lf Detector Detector Sensibilidad m nima Sensibilidad m xima El detector es m s sensible a movimientos transversales a su campo de mira Sensibilidad del detector de movimiento para uso interior y exterior Fe E Apunte el detector hacia m s arriba para una cobertura mayor Apunte el detector hacia abajo para una cobertura menor Regulaci n de la cobertura del detector de movimiento para uso interior gt Apunte el detector hacia abajo para una cobertura menor Apunte el detector hacia m s arriba para una cobe
3. pleine puissance Appuyez sur le bouton de mise hors tension OFF partie du bas puis rel chez le L clairage devrait s teindre Appuyez sur le bouton DIM puis rel chez le L clairage devrait s allumer l intensit pr r gl e Bouton de mise sous hors tension Couvercle d acc s Interrupteur d appoint 5 Continuez d appuyez sur le bouton DIM jusqu ce que vous obteniez le degr d clairage d sir Note Le r cepteur conserve la derni re intensit d clairage utilis e Pour rappeler ce r glage appuyez sur le bouton DIM puis rel chez le Note En cas de panne de courant le r glage par d faut du rh ostat est fix 50 de l intensit lumineuse IMPORTANT Attendez une ou deux secondes apr s avoir appuy sur un bouton du transmetteur avant d appuyer de nouveau dessus pour permettre la transmission de s effectuer Note Si l clairage ne s allume pas ou s il s allume par intermittence lorsque vous appuyez sur un bouton du transmetteur consultez le Guide de d pannage Remplacement de la pile Le transmetteur mural exige une pile au lithium 3 V de type CR2032 Lorsqu il est exp di le transmetteur comprend une pile En condition d utilisation normale la pile devrait durer environ 5 ans Retirez la pile si vous ne pr voyez pas utiliser le transmetteur pour une p riode prolong e 1 Appuyez sur la porte d acc s au moyen du pouce puis faites la glisser pour l ouvrir 2 Re
4. rotule sur le d tecteur dans la douille du support de montage Note Vous devriez entendre un claquement Dirigez le d tecteur vers la zone o vous voulez d tecter le mouvement Serrez la vis de serrage IMPORTANT Le d tecteur doit tre mont avec le couvercle inf rieur vers le bas afin d assurer l tanch it Douille de support Support de montage Vis de serrage ae ad Monture a rotule D tecteur Installation du d tecteur de mouvement V rification du fonctionnement et du r glage Note Lorsque l appareil est mis en circuit ou chang de mode attendre 1 2 minute Localisez les commandes RANGE et ON TIME sur le d tecteur de mouvements D tecteur de mouvements int rieur Les commandes RANGE et ON TIME sont situ es l int rieur du compartiment des piles sur le devant de d tecteur Pour r gler ces commandes retirez le couvercle du compartiment des piles en le faisant glisser vers le bas D tecteur de mouvements ext rieur Les commandes RANGE port e et ON TIME dur e de marche sont situ es dans le bas du d tecteur A l aide de vos ongles ou d un petit tournevis t te plate soulevez doucement le couvercle jusqu ce qu il s ouvre 1 V rifiez le fonctionnement Mettez la commande ON TIME au mode TEST Marchezdevantle d tecteur Le voyantindicateur DEL devrait clignoter lorsqu un mouvementest d cel consultez la figure pour conna tre l emplaceme
5. Heati Zenith Remote Controlled Products This manual includes operating instructions for a variety of remote controlled products All products work on the same principle and use the same code setting information Please read all instructional information and note any specific information pertaining to your particular product This manual applies to the following products Transmitters Remote Control Indoor Wireless Motion Sensor Outdoor Wireless Motion Sensor Add A Switch Kid s Remote Control 3 Way Wall Switch Receivers Wall Switch Receiver Receptacle Receiver CODE SETTINGS Note Most single system installations will not require any change to the code setting Transmitter s and receiver s must have the same code and group setting to work together Switches 1 through 3 set the code Switch 4 sets the Group A or B See page 2 for switch locations Example 1 Code Settings System 1 Factory Setting Left Side Controls gt Right Side Controls Controls One Set of E NA a Controls One Set of Group A or Group Group A or Group B Receiver s nae a B Receiver s l le erent Transmitter s Receiver s Code 1 Transmitter s Receiver s Code XIXIX X xxx Group A a Group B Indicates Position of Switch 2009 HeathCo LLC FEA
6. autre de ses composanis fournis invalidera totalement la pr sente garantie Cette garantie n inclut pas le remboursement pour le d rangement l installation le r glage la perte d utilisation le service non autoris ou les frais d exp dition pour le renvoi de la marchandise La garantie ne couvre que les produits assembl s HeathCo LLC et ne s tend pas aux autres quipements et composants que le client pourrait utiliser conjointement avec nos produits CETTE GARANTIE TIENT EXPRESSEMENT LIEU DE TOUTES AUTRES GARANTIES EXPLICITES OU IMPLICITES Y COMPRIS DE TOUTE GARANTIE DE REPRESENTATION OU DE CONDITION DE CONVENANCE A LA COMMERCIA LISATION OU A LEFFET QUE LES PRODUITS CONVIENNENT A UN BUT OU A UNE UTILISATION PARTICULIERE ET SPECIFIQUEMENT DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES LE REMPLACEMENT OU LA R PARATION CONSTITUENT LE SEUL RECOURS DU CLIENT ET HEATHCO LLC NE POURRA ETRE TENUE RESPONSABLE DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES Y COMPRIS SANS S Y LIMITER LES PERTES COMMERCIALES ET PERTES DE PROFIT QU ELLES SOIENT PREVISIBLES OU NON Certaines provinces n autorisent pas l exclusion ou la limitation des dommages indirects ou secondaires et la limitation ou l exclusion ci dessus pourrait ne pas s appliquer vous Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos demandes li es la garantie HeathCo LLC se r serve le droit de mettre fin la
7. tre install e pour plus de commodit 1 Pour attacher la pince de pare soleil la t l commande si d sir poussez la dans la fente l arri re de lat l commande jusqu ce qu elle se mette en place avec un bruit sec Pour enlever la pince de pare soleil ins rez un petit tournevis t te plate dans la fente l arri re de la t l commande Enfoncez doucement la partie de la pince qui est l int rieur de la fente l aide du tournevis tout en tirant la pince hors de la t l commande partir du haut Tournevis t te plate Pince de pare soleil facultative Enl vement de la pince de pare soleil Vue arri re SIVONVHS DETECTEURS DE MOUVEMENT SANS FIL INTERIEURS ET EXTERIEURS D tecteur de mouvements sans fil ext rieur D tecteur de mouvements sans fil int rieur Caract ristiques Aucun c blage n cessaire Jusqu 21 m tres de port e de d tection 180 de couverture Ext rieur Jusqu 9 1 m tres de port e de d tection 150 de couverture Int rieur Sensibilit r glable Fonctionnement Jour Nuit ou Nuit seulement Mode d essai Utilise 2 piles AA Montage sur mur ou avant toit Ext rieur Peut tre fix directement au mur ou au moyen d un support de montage fourni Int rieur Commande le r cepteur sur une distance maximum de 30 m tres S lection du mode de nuit ou du mode 24 heures Ces d tecteurs sont en mesure de d celer l
8. la caja Monte la placa de pared en el receptor de pared con interruptor usando los tornillos cortos provistos Encienda la energ a al circuito del interruptor de la l mpara H galo en su disyuntor o en la caja de fusibles Operaci n Verifique que el desconectador de energ a est en la posici n ON lado derecho Pulse y suelte el bot n ON parte superior La luz deber a encenderse con luminosidad total Nota Si est controlando una l mpara aseg rese que est conectada a un tomacorriente con interruptor y que la l mpara est encendida Pulse y suelte el bot n OFF parte inferior La luz deber a apagarse Pulse y suelte la parte superior o inferior del bot n atenuador La luz deber a encenderse al 50 de su luminosidad o seg n la ltima calibraci n Pulse y suelte la parte superior del bot n atenuador DIM para aumentar la luminosidad Pulse y suelte la parte inferior del bot n atenuadorparadisminuirlaluminosidad Nota Hay 5 calibraciones del atenuador que van del 15 al 90 de la luminosidad Fije el nivel deseado en el atenuador DIM Nota El atenuador memoriza la ltima calibraci n usada Para volver a la ltima calibraci n del atenuador ON u OFF pulse y suelte la parte superior o inferior del bot n atenuador Nota En caso de una falla de energ a la calibraci n del atenuador se fija en el ajuste hecho en f brica del 50 AVISO Cuando el bot n de encendido del receptor del inte rruptor de par
9. piz o con un punz n de marcar las ubicaciones de los orificios Con una broca de 2 5 mm 0 1 pulgadas taladre dos orificios gu a para los tornillos de montaje Si no lo instala directamente a la madera o al esp rrago de la madera taladre orificios gu a de 5mm 0 2 pulgadas y utilice las anclas de pared que se incluyen Usando los dos tornillos provistos fije el detector de movi miento para uso interior a un objeto s lido y firme ejemplo pared armario poste etc Aseg rese que la unidad no tenga obstrucciones en su l nea de mira IMPORTANTE Apriete a mano solamente No apriete demasiado 2 Detector de 2 Superficie movimiento superior del mostrador Tornillo de montaje Fijacion del detector de movimiento directamente a la pared 598 1135 10 Instalaci n del detector de movimiento para uso exterior Instale la consola de montaje del detector en donde se nece site detectar movimiento Acople esta consola de montaje a un objeto robusto ejemplo arbol poste casa etc usando los dos tornillos provistos Asegurese que la unidad no tenga obstrucciones en su linea de mira Nota Sujete la consola de montaje verticalmente si lo instala a una superficie curva como un poste Instale el detector de movimiento a la consola de montaje Usando un destornillador cabeza Philips afloje el tornillo de la abrazadera en la consola de montaje Inserte la montura giratoria de bola del detector en el z calo de la co
10. sur le transmetteur et sur le r cepteur voir R glage des codes 2 Branchez le luminaire commander dans la prise du haut Note Si la prise est install e correctement l appellation CONTROLED devrait tre inscrite sous la prise du haut 3 Activezlesboutons ON OFF sous horstension delat l commande pour v rifier le fonctionnement Le luminaire devrait s allumer et s teindre lorsque vous appuyez sur le bouton appropri Note Cette commande ne comprend pas de fonction rh ostat SIVONVHS SYMPTOME GUIDE DE DEPANNAGE CAUSE POSSIBLE SOLUTION Le dispositif ne s allume pas 1 2 Le disjoncteur ou le fusible sont teints L interrupteur sur le dispositif est teint Le dispositif estinterrompu parun autre dispositif Le dispositif ne r pond pas imm dia tement apr s l installation Les signaux du transmetteur sont bloqu s ou le transmetteur est hors de port e Les piles du transmetteur sont fai bles Les micro interrupteurs sur le transmet teur et le r cepteur ne correspondent pas les uns aux autres Le dispositif est d fectueux 1 2 V rifiez que le disjoncteur ou le fusible sont allum s V rifiez que l interrupteur sur le dispositif est allum Modifiez les codes du transmetteur et du r cepteur Attendez 90 secondes de p riode d initialisation d tecteur de mouve ment distance V rifiez s il y a des objets m talliques pouvant bloquer le sign
11. 9045 ATTN Technical Service If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product Please keep your dated sales receipt it is required for all warranty requests REGULATORY INFORMATION This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The user is cautioned that changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s authority to operate the equipment 12 598 1135 10 TWO YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of two years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in
12. Figure 1 R f rez vous la Figure 2 ci dessous pour savoir comment connecter les fils du r cepteur de l interrupteur mural aux fils existants R tablissez le courant au niveau du panneau de disjoncteurs ou de la bo te fusibles Note Si l clairage s allume imm diatement et demeure allum inversez le raccordement du fil de connexion de l un des interrupteurs 12 Fils de connexion AU FIL SOUS TENSION O AU LUMINAIRE AU FIL SOUS TENSION OU AU LUMINAIRE NOIR NOIR z a o o Transmetteur R cepteur VERT terre Figure 2 C blage de l interrupteur mural trois voies Fil de terre vert nu Fil rouge typique Fil de terre vert de l interrupteur R cepteur Interrupteur mural Vis de _ ON OFF fixation Boite de connexion Ve Fil noir is de plaque murale Plaque murale Bouton du rh ostat Interrupteur d alimentation Figure 3 Installation d un interrupteur mural tripolaire transmetteur illustr 598 1135 10 Fonctionnement INFORMATIONS SUR LE RECEPTEUR 1 V rifiez que le sectionneur sur l metteur et sur le r cepteur Tous les r cepteurs ont les caract ristiques et valeurs nominales est la position ON c t droit suivantes 2 Appuyez sur le bouton ON partie du haut puis rel chez le L clai Valeur nominale pour une tension de 120 VCA 60 Hz rage devraits allumerapleine intensit Note Po
13. al sliding it upward until it locks in place Removing Access Door and Battery KID S REMOTE CONTROL Operation 1 Verify that receiver has been properly installed See Receiver Information page 10 Remote Control ae Back Philips Head Screw Access Door Removing Access Door Continued JOERIE 2 To remove tab from battery chamber remove screw in access door of remote with a small phillips head screwdriver Gently pull tab out of battery chamber Reassemble access door in reverse order Tab am Removing Tab In Battery Chamber 3 Push and release the ON button left button to turn light on or the OFF button right button to turn light off Note Red light on remote should come on while button is depressed IMPORTANT Wait 1 to 2 seconds after you press a transmitter button before you press it again to allow the transmission to be completed Note If light does not turn on or intermittently turns on and off when remote buttons are pushed see Troubleshooting Guide Battery Replacement The remote control requires a type A23 12 Volt alkaline battery to operate The remote control is shipped with the battery installed With typical use the battery will last approximately one year Remove battery when remote will not be used for an extended period of time To replace the battery follow the instructions below 1 Turn remote control
14. bille l arri re du d tecteur de mouvements Ce support est con u pour tre fix de trois fa ons l arri re du d tecteur en fonction des besoins de l utilisateur Suivez les tapes ci apr s pour proc der l installation D terminez d abord le meilleur emplacement en fonction de la couverture souhait e D terminez le meilleur endroit pour installer le support mural Ins rez ensuite les onglets du support pivotant bille dans les rainures l arri re du d tecteur qui correspondent la position souhait e par rapport au support mural Vis de fixation du Arri re du d tecteur support pivotant Onglet Monture Support pivotant bille rotule Fixation du support pivotant bille au d tecteur de mouve ments int rieur installation la verticale 598 1135 10 2 Douille de support Support de montage se Couvercle du compartiment Retirez les piles Au moyen d un tournevis Phillips ins rez la vis de montage dans Porifice du compartiment des piles qui s aligne avec l orifice l arri re du support pivotant bille Serrez compl tement Placer le support de montage du capteur sur le mur l endroit o vous d sirez l installer puis marquer l emplacement des orifices au moyen d un crayon ou d un pointeau Au moyen d un foret de 2 5 mm 0 1 po percer deux trous pour les vis de fixation Si les vis ne sont pas fix es directement dans le bois ou dans un montant mural
15. de 7 30 AM a 4 30 PM CST L V Usted puede tambi n escribir a HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Servicio T cnico Si se llama al Servicio T cnico por favor tener lista la siguiente informaci n Numero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garantia 598 1135 10 27 TONVdSA INFORMACION REGULATORIA Este aparato cumple con la Parte 15 de las Reglas de la FCC Comisi n Federal de Comunicaciones y con la RSS 210 de las Industrias del Canad El funcionamiento est sujeto a las dos siguientes condiciones 1 este aparato no puede causar interferencias da inas y 2 este aparato debe aceptar cualquier interferencia recibida incluyendo una interferencia que pueda causar un funcionamiento indeseable Se advierte al usuario que cambios o modificaciones no aprobadas expresamente por la parte responsable de cumplir con los regla mentos podr a invalidar la autoridad del usuario para el uso de este equipo GARANT A LIMITADA A 2 A OS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 2 a os desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas
16. de la caja de empalme y la pared Inserte la antena en la cavidad de la pared mientras coloca el interruptor en la caja de empalme IMPORTANTE Identifique los conductores del interruptor tridireccional seg n el diagrama de la Figura 1 Vea la figura 2 de abajo cuando conecte los conductores del receptor de pared con interruptor a los conductores existentes 12 Encienda la energ a al circuito del interruptor de la l mpara H galo en su disyuntor o en la caja de fusibles Nota Si la luz se enciende inmediatamente y permanece encendida invierta las conexiones de los conductores retorno vueltas en uno de los interruptores 598 1135 10 Conductores retorno AL CONDUCTOR i VIVO O ALA ALCONDUCTOR J poso LAMPARA VIVO O ALA LAMPARA NEGRO NEGRO gt 7 a o Transmisor Receptor VERDE Tierra Figura 2 Conexi n del conmutador tridireccional de pared Conductor verde o desnudo de conexi n a tierra Conductor verde de conexi n a tierra del conmutador Conductor A rojo t pico Bot n ON OFF Encen Interruptor did d ido apagado de pared Tornillo del interruptor de pared la Pared S Caja de empalme Conductor Tornillo de la placa de pea pared bot n atenuador DIM Desconectador Placa de pared de energia Figura 3 Instalacion del interruptor tridireccional de pared se muestra el transmisor Continuaci n Operaci
17. its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Please keep your dated sales receipt it is required for all warranty requests JOERIE HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold 598 1135 10 13 Heati Zenith Productos a control remoto Este manual incluye las instrucciones de operaci n pa
18. small flat head screwdriver into slot on back of remote Gently push down on portion of visor clip inside slot with screwdriver while pulling clip out of remote from top Flat Head Screwdriver Optional Visor Clip Removing Visor Clip Rear View m zZ O a 72 E INDOOR AND OUTDOOR WIRELESS MOTION SENSOR Features No wiring required Upto 70 feet sensing range 180 Coverage Outdoor Upto 30 feet sensing range 150 Coverage Indoor Adjustable sensitivity Day Night or Night only operation Test mode Uses 2 AA batteries Wall or eave mount Outdoor Can be mounted directly to wall or with mounting bracket included Indoor Controls receivers up to 100 feet away Indoor Wireless Motion Sensor Outdoor Wireless Motion Sensor Select Night or 24 Hour Mode These sensors are able to detect motion day and night or night only To set the detection mode remove battery compartment cover by sliding the cover down Remove batteries if necessary Slide the DETECT switch to either the DAY NIGHT or NIGHT ONLY position Replace battery compartment cover by reversing the above instructions Installing Batteries Before mounting outdoor motion sensor remove battery compart ment cover by sliding the cover down For indoor motion sensor install batteries after sensor is in stalled Install 2 AA batteries according to polarity markings inside the battery compartment Replace battery compa
19. 30m del receptor Nota El transmisor debe montarse aproximadamente a 4 pies del piso y en posici n vertical 3 Antes del montaje sostenga el transmisor en la posici n seleccionada y verifique su operaci n vea Operaci n Nota Si el transmisor no opera correctamente vea Gu a del An lisis de Aver as 4 Sostenga el transmisor en el sitio y marque los orificios de montaje con un l piz o con un objeto punzante 5 Retire el transmisor y taladre orificios de 3 16 pulgadas Usando un martillo inserte en los orificios las anclas para pared provistas 6 Fije el transmisor a la pared usando los dos tornillos provis m y gt zZ je Reemplazo de la bater a El transmisor del interruptor de pared requiere para operar una bater a de litio de 3 voltios tipo CR2032 El transmisor se lo env a con la bater a instalada Con uso normal la bater a dura aproxi madamente 5 a os Retire la bater a cuando no se vaya a utilizar el transmisor por un per odo de tiempo extenso tos 1 Coloque el pulgar en la tapa de acceso y deslicela hacia abajo Operaci n para abrirla 1 Verifique que el receptor haya sido instalado correctamente 2 Doble hacia fuera y con Aleta de Vea Informaci n del receptor en la p gina 24 suavidad la aleta de traba traba de la Pulse y suelte el bot n ON parte superior La luz deber a La bater a saltar bater a encenderse con luminosidad total 3 Retire la bater
20. CODES Note La plupart des installations simples n exige pas la mo dification des codes pr r gl s Les codes et les groupes des transmetteurs et des r cepteurs doivent tre r gl s de fa on identique pour fonctionner ensemble Les micro interrupteurs 1 3 servent r gler le code Le micro interrupteur 4 sert s lectionner le groupe A ou B Consultez la page 29 pour conna tre l emplacement des micro interrupteurs Exemple 1 R glage des codes System 1 r glage en usine Commandes du c t Commandes du c t iG DA gauche Commande oni a droit Commande un un ensemble de E l K ensemble de r cep r cepteurs du groupe on fl on teurs du groupe A A ou du groupe ou du groupe B B f for l a Code des transmetteurs r Code des transmetteurs cepteurs r cepteurs 1 1 Groupe A Groupe B Indique la position du micro interrupteur 2009 HeathCo LLC 29 Exemple 2 R glage des codes syst me 2 Note Lors de l utilisation ind pendante de plus d un syst me tablissez un code diff rent pour chaque syst me Vous pouvez avoir jusqu 8 codes distincts en r glant les 3 micro interrupteurs Code des R cepteurs 1 X XIXIX Groupe A Code des Trans metteurs 1 X XIXIX T Mic
21. R D APPOINT Installation 1 Retrait de l onglet du compartiment de la pile Retirez le couvercle avant du transmetteur d appoint Tirez doucement sur l onglet pour le retirer du compartiment de la pile Replacez le couvercle sur le transmetteur d appoint Lemm J gt a Compartiment de la pile Type CR2032 Couvercle d acc s Retrait de l onglet de la pile S lectionnezl emplacemento serainstall letransmetteur Note Le transmetteur doit tre situ tout au plus 30 m tres 100 pieds du r cepteur Note Le transmetteur doit tre install environ 4 pieds au dessus du plancher en position verticale Avant de l installer placez le transmetteur l endroit pr vu de son installation etv rifiez en le fonctionnement voir Fonctionne ment Note Siletransmetteurne fonctionne pas correctement consultez la section Guide de d pannage En maintenant le transmetteur en place marquez les orifices de montage au moyen d un crayon ou d un objet pointu Enlevez le transmetteur puis percez deux orifices de 3 16 po Enfoncez les ancrages a placopl tre fournis dans les orifices au moyen d un marteau Fixez le transmetteur au mur au moyen des deux vis four nies Fonctionnement Assurez vous que le r cepteur est bien install Consultez la section nformations sur le r cepteur la page 38 Appuyez sur le bouton de mise sous tension ON partie sup rieure puis rel chez le L clairage devrait s allumer
22. RTANTE Luego de presionar un bot n del transmisor espere de 1 a 2 segundos para presionarlo de nuevo y permitir que se complete la transmisi n Nota Si al presionar los botones del transmisor la luz no se enciende ni lo hace en forma intermitente vea Gu a de An lisis de Aver as Reemplazo de la bater a El control remoto requiere para operar una bater a alcalina de 12 voltios tipo A23 El control remoto viene con la bater a instalada Con uso normal la bater a dura aproximadamente un a o Retire la bater a cuando no se vaya a utilizar el transmisor por un per odo de tiempo extenso Para cambiar la bater a siga las siguientes instrucciones 1 Voltee el control remoto 2 Retire el tornillo de la tapa de acceso del control remoto utilizando un destornillador tipo Phillips 3 Retire la tapa de acceso y p ngala a un lado 4 Retire la bater a Instale la bater a de repuesto Aseg rese instalar la bater a con la orientaci n correcta vea la ilustraci n 5 Vuelva a colocar la tapa de acceso en el orden inverso Compartimiento Il pi te de la bateria Tipo A23 Interior del control remoto TRANSMISOR DE PARED CON CONMUTADOR TRIDIRECCIONAL IMPORTANTE Este producto debe usarse junto con un receptor de pared con interruptor Para instalar y usar este producto se necesita que haya una instalaci n con circuito conmutado Nota Sino esta familiarizado con este cableado el ctrico consulte con un el
23. TURES Products are UL cUL and or FCC IC tested and approved Operational range of up to 100 feet Heath Zenith wireless lighting controls are designed to work together Simply determine which transmitter s you would like to have control which receiver s and set the code setting to match Example 2 Code Settings System 2 Note When operating more than one system independently ofeach other set each system to a different code There are 8 codes avail able by changing the settings of switches 1 through 3 Receiver s Transmitter Code Code 1 XIXIX lt XIXIX Group A 2 Group Switch Group A Selection Shown Example 3 Code Settings with Single Transmitter When using a single group transmitter i e Door Transmitter Add A Switch Remote Motion Sensor the code and group settings must match receiver s for the system to function properly Receiver s Remote Motion Code Sensor Code 1 1 X X XIX XIX Group A Group A Note This setting will work independently of examples 1 and 2 because the code setting is different Note The code can also be changed to reduce interference problems from other wireless products i e wireless phones garage door open ers etc See Troubleshooting Guide for more information 598 1135 10 m Z a 7 I Left Side il Right Side B
24. a del z calo A Pulse y suelte el bot n OFF parte inferior La luz deber a 4 Instale en el z calo la bater a AA apagarse de repuesto con el lado Pulse y suelte el bot n atenuador La luz deber a encenderse hacia arriba vea la ilustraci n Tapa de r al nivel ATENUADOR Presione la bater a hasta que acceso Bater a la aleta de traba se cierre a de litio presi n en su sitio CR2032 5 Vuelvaa colocarla puerta de EJ 598 1135 10 acceso desliz ndola hacia arriba hasta que se fije en su sitio Retiro de la tapa de acceso y la bater a CONTROL REMOTO PARA NINOS Operacion 1 Verifique que el receptor haya sido instalado correctamente Vea Informaci n del receptor en la p gina 24 Parte posterior del control remoto Tornillo cabeza Phillips Tapa de acceso Retiro de la puerta de acceso Para retirar la aleta del compartimiento de la bater a retire el tornillo de la puerta de acceso del control remoto usando un destornillador tipo Phillips Hale con suavidad la aleta hacia fuera del compartimiento de la bater a Vuelva a colocar la tapa de acceso siguiendo el orden inverso o gt Retiro de la aleta del compartimiento de la bateria Pulse y suelte el bot n ON bot n izquierdo para encender o el bot n OFF bot n derecho para apagar la luz Nota La luz roja en el control remoto debe encenderse cuando se presiona el bot n IMPO
25. a segunda unidad recep tora usando un nico control remoto aseg rese que el segundo juego de interruptores de c digo del lado derecho emparejen con los interruptores de c digo de cada receptor Ver la secci n Calibraciones del C digo Lado izquierdo Para calibrar los interruptores de c digo del lado izquierdo Lado derecho Para calibrar los interruptores de c digo del lado derecho e dE derecho DIM Lado izquierdo rs ysl Cade derecho Lado izquierdo P A tato sereno ees 14 Ido derecho Lado izquierdo 2 OFF APAGADO OFF APAGADO Controles de las funciones IMPORTANTE Espere de 1 a 2 segundos despu s de pulsar el bot n de un transmisor antes de pulsarlo de nuevo para permitir que la transmisi n se complete Nota Si la luz no se prende o si se prende y apaga intermitente mente cuando se pulsan los botones del transmisor vea la Gu a de An lisis de Aver as Presilla opcional del visor del carro incluida Para mayor conveniencia en el control remoto se incluye una presilla opcional del visor del carro que puede ser instalada 1 Para unir si se desea la presilla del visor del carro al control remoto emp jela contra la ranura de la parte posterior del control hasta que se cierre a presi n en su lugar Para retirar esta presilla inserte un destornillador plano peque o en la ranura de la parte posterior del control Con el destornillador empuje suavemente la porci n de la presilla del viso
26. al ou reposi tionnez le transmetteur V rifiez si les piles sont charg es et remplacez les si n cessaire Assurez vous que les commutateurs du transmetteur et du r cepteur sont r gl s aux m me positions V rifiez si c est le cas en utilisant un dispositif diff rent Le dispositif ne s teint pas M mes cause qu en 5 6 et 7 ci des sus M mes solutions qu en 5 6 et 7 ci dessus Le dispositif s allume au hasard Panne d lectricit de courte de du r e Un autre transmetteur est r gl la m me fr quence SERVICE TECHNIQUE Lors de la prochaine mission le transmetteur replacera le r cepteur l tat appropri Modifiez les codes du transmetteur et du r cepteur Veuillez faire le 1 800 858 8501 service en anglais seulement pour obtenir de l aide avant de retourner Particle au magasin En cas de probl me suivez ce guide Vous pouvez aussi visiter notre site Web www hzsupport com Si le probl me persiste composez le 1 800 858 8501 service en anglais seulement entre 7 h 30 et 16 h 30 HNC du lundi au vendredi Vous pouvez aussi crire au HeathCo LLC P O Box 90045 Bowling Green KY 42102 9045 ATTN Technical Service Service technique Lors d un appel au service technique veuillez avoir les renseignements suivants port e de main num ro du mod le date d achat et endroit de l achat Aucune pi ce de rechange n est disponible pour ce pr
27. ch into junction box IMPORTANT Label wires on existing 3 way switch according to the diagram in Figure 1 Refer to Figure 2 below when con necting wall switch receiver wires to existing wires 12 Turn on the powerto the light switch circuit Do this at your circuit breaker or fuse box Note If the light turns on immediately and remains on reverse the travel wire connections on one of the switches Travel Wires TO HOT Ui TO HOT OR LIGHT BLACK nal Transmitter Receiver GREEN Ground Figure 2 Wiring 3 Way Wall Switch 598 1135 10 Green or Bare Ground Wire Red Wire Typical Green Ground Wire From Switch Wall ON OFF Switch Wall Switch Junction Box Disconnect Switch Figure 3 Installing 3 Way Wall Switch Transmitter Shown Wall Plate Operation 1 Verify the power disconnect switch on the transmitter and receiver is in the ON right side position 2 Push the ON top button and release The light should turn on full bright Note If you are controlling a lamp make sure it is connected to the switched outlet and the lamp is switched on 3 Push the OFF bottom button and release The light should turn off 4 Push the DIM button and release The light should turn on at 50 brightness or last setting Note Receiver remembers the last DIM setting used To recall last DIM setting push and release the DIM bu
28. conductor de energ a que retiro del interruptor viejo Use uno de los conectores de alambre provistos para asegurar los conductores vea la ilustraci n Conecte el conductor verde de conexi n a tierra del receptor al conductor de conexi n a tierra retirado del interruptor viejo Use uno de los conectores de alambre provistos para asegurar los conductores vea la ilustraci n Conductor de conexi n a tierra Bot n ON OFF desnudo o verde Encendido f apagado Interruptor de Caja de pared empalme Tornillo del interruptor de pared Blanco Tornillo de Neutro la placa de pared y Pared Antena Placa de pared Bot n atenuador DIM Desconectador de energ a Instalaci n del receptor de pared con interruptor 598 1135 10 25 8 9 10 11 Revise lasconexiones delos conductores paraasegurarse queest n bien hechas y que no haya conductores desnudos a la vista Guie la antena entre la parte inferior de la caja de empalme y la pared Inserte la antena en la cavidad de la pared mientras coloca el interruptor en la caja de empalme Coloque el receptor de pared con interruptor en la caja de empalme con el bot n atenuador ubicado a la derecha Use los dos tornillos provistos largos del interruptor de pared para montar el receptor a la caja vea la ilustraci n Mientras hace esto empuje el exceso de cables hacia la caja Pueda que necesite doblar los conductores para que se acomoden en
29. d release The light should turn off 4 Push the DIM button and release The light should turn on at a DIM level Add A Switch DIM Button ON OFF Button Access Door Add A Switch 598 1135 10 5 Continue to press the DIM button until the desired dim level is reached Note Receiver remembers last DIM setting used To recall last DIM setting push and release the DIM button Note The DIM setting defaults to 50 in the event of a power failure IMPORTANT Wait 1 to 2 seconds after you press a transmitter button before you press it again to allow the transmission to be completed Note If light does not turn on or intermittently turns on and off when transmitter buttons are pushed see Troubleshooting Guide Battery Replacement The wall switch transmitter requires a type CR2032 3 volt lithium battery to operate The transmitter is shipped with the battery installed With typical use the battery will last approximately 5 years Remove battery when transmitter will not be used for an extended period of time 1 Place thumb on access door and slide down to open 2 Carefully bend locking tab outward Battery will pop up 3 Remove battery from socket 4 Install replacement battery in socket plus side up see Battery y Locking Tab A y Access I illustration Press down on CR2032 battery until locking tab snaps Door Lithium into place Battery 5 Reinstall access door by
30. de f brica o mano de obra ser corregido sin cargo para Ud No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por HeathCo LLC y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A EST EXPRESAMENTE EN LUGAR DE OTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACI N O CONDICI N DE COMERCIABILIDAD O QUE LOS PRO DUCTOS SE ADAPTEN PARA CUALQUIER PROP SITO O USO EN PARTICULAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILI DAD POR PARTE DE HEATHCO LLC POR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUALQUIER P RDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuente
31. de la consola de montaje para pared Parte posterior del Tornillo del soporte detector de montaje tipo bola pa Ranuras para la aleta Aleta Montura giratoria de bola Consola de montaje tipo bola Sujeci n de la consola de montaje tipo bola al detector de movimiento para uso interior se muestra la instalaci n vertical Continuaci n m y gt zZ je Inserte las aletas de la consola de montaje tipo bola en las ranuras de la parte posterior del detector que mejor alineen este detector con la consola de montaje de pared Retire las bater as Con un destornillador cabeza Phillips inserte el tornillo de montaje en el orificio del compartimiento de la bater a que alinee con el orificio posterior de la consola de montaje tipo bola Apriete bien Coloque el soporte de montaje del detector sobre la superficie que lo va a instalar y con un l piz o un punz n de marcar marque la ubicaci n del orificio Con una broca de 2 5 mm 0 1 pulgadas taladre dos orificios gu a para los tornillos de montaje Si no lo instala directamente ala madera o al esp rrago de la madera taladre orificios gu a de 5mm 0 2 pulgadas y utilice las anclas de pared que se incluyen Usando los dos tornillos provistos fije el detector de movimiento para uso interior a un objeto s lido y firme ejemplo pared armario poste etc Aseg rese que la unidad no tenga obstrucciones en su l nea de mira Nota Sujete la cons
32. eceptor de pared con interruptor Vista ampliada de un interruptor t pico del c digo la calibraci n hecha en Receptor con tomacorriente f brica es OFF apagado 15 598 1135 10 CONTROL REMOTO Nota Un control remoto puede operar independientemente dos unidades receptoras Si se desea operar independien temente mas de dos receptores se necesitaran comprar controles remotos adicionales 1 Retire laaletadel compartimento dela bater a Retirela tapa posterior del transmisor Hale la aletacon suavidad fuera del compartimento de la bater a Deslice la tapa en el transmisor Compartimento de la bater a F Fesi tipo A23 MD Tapa de la bater a Aleta Vista posterior del control remoto Funciones del control remoto Los tres botones del lado izquier do del control remoto hacen funcionar a una o m s unidades receptoras que tienen la misma calibraci n del c digo Los tres botones de la derecha har n funcionar un segundo juego de uno o m s receptores ON Enciende cualquier unidad receptora del mismo c digo que este control remoto OFF Apaga cualquier unidad receptora del mismo c digo que este control remoto DIM Activa la caracter stica REDUCTORA de cualquier unidad receptora del mismo c digo que este control remoto Nota Al pulsar el bot n DIM se pasa por los cinco niveles de luminosidad 16 Nota Para operar independientemente un
33. ectricista para su instalaci n Adem s algunos c digos locales sobre edificios pueden exigir que la instalaci n la realice un electricista calificado Instalaci n Seleccione el interruptor de luz que ser reemplazado por el transmisor de pared con conmutador tridireccional ADVERTENCIA Apaguelaenerg aal circuito delinterruptor de la l mpara antes de proceder Haga esto en su disyuntor o en la caja de fusibles P a i AL CONDUCTOR Terminal com n tornillo oscuro necro OA LA L MPARA 059 959 Sol AL conpucToR lt Interruptor tridireccional tridireccional Conductor retorno o vuelta Conductor retorno o vuelta VERDE Tierra Figura 1 Cableado de un circuito conmutado t pico 22 598 1135 10 3 Retire la placa y el interruptor de pared existentes Identifique a los conductores del interruptor existente seg n el diagrama de la Figura 1 Nota Aqu se muestra el cableado de un circuito conmutadot pico El cableado real y los colores de los conductores pueden variar 4 Desconecte los dos conductores retornos el conductor conec tado al terminal com n y el conductor de conexi n a tierra 5 Retire la placa de pared del transmisor con conmutador tridireccional A ADVERTENCIA Los conductores neutros color blanco del circuito conmutado tridireccional deben recorrer por todo el circuito sin interrupci n Si se presenta este conductor no lo conecte a ningu
34. ed se usa para encender las luces los comandos de OFF apagado enviados por cualquier transmisor ser n ignorados Cuando se presiona el bot n de apagado OFF del receptor la luces se apagar n y el receptor otra vez aceptar los comandos de encendido y apagado ON OFF Reemplazo de la bombilla Mueva el desconectador de energ a a la posici n OFF lado izquierdo Reemplace la s bombilla s A CUIDADO No exceda los l mites de carga m ximos listados arriba m y gt zZ je RECEPTOR CON TOMACORRIENTE Caracteristicas y potencia nominal Controla una carga incandescente maxima de hasta 1800 vatios e Controla las funciones encendido apagado de la iluminaci n Controla cargas hasta de 15 Amperios Instalaci n 1 Retire el tomacorriente existente de la caja de empalme si es necesario Conecte el conductor verde del tomacorriente al conductor verde de conexi n a tierra de la caja de empalme Conecte el conductor negro del tomacorriente al conductor de carga de la caja de empalme y el conductor blanco del tomacorriente al conductor neutro de la caja de empalme Las conexiones deber an aparecer como se muestra en la ilustraci n Antes de instalar el artefacto de luz aseg rese que en las conexiones no haya conductores expuestos Coloque el tomacorriente en la caja de empalme utilizando los dos tomillos largos provistos Nota Verifique que el tomacorriente con la indicaci n CONTROLADO est hacia ar
35. el detector remoto de movimiento 1 X XIX x Grupo A 4 Grupo A Nota Esta calibraci n funcionar independientemente de los ejemplos uno y dos porque la calibraci n del c digo es diferente Nota El c digo puede tambi n cambiarse para reducirlos problemas de interferencia que vienen de otros productos inal mbricos ejem plo Tel fonos inal mbricos abridores de puertas de garajes etc Para m s informaci n vea Gu a de An lisis de Aver as 598 1135 10 S UBICACIONES DE LOS INTERRUPTORES DE CIRCUITO IMPRESO Interruptores Interruptores de c digo l de c digo i ue SR meme a de circuito Tapa de a Impreso Interruptores fae ea N J de circuito Serna v impreso Control remoto Detector inal mbrico de movimiento Detector inal mbrico de movimiento para uso interior para uso exterior Interruptores x de circuito O impreso Interruptores de circuito PIT impreso a O Tapade Interruptores de Seno circuito impreso Conmutador tridireccional de pared ON Interruptor A a adible Nota La X ha sido colocada en los Interruptores de circuito impreso TX interruptores para ayudar a aclarar las calibraciones del c digo de la p gina anterior Interruptores en de circuito ites impreso j R
36. ent e correctement voir l illustration 5 Remettez la porte d acc s en place Vis Philips Porte Compartiment a d acc s pile type A23 m Retrait de la porte d acc s 2 Pour enlever l onglet du compartiment pile retirez la vis de la porte d acc s de la t l commande au moyen d un petit tournevis Philips Tirez doucement sur l onglet Remettez la porte d acc s en place Int rieur de la t l commande METTEUR D INTERRUPTEUR MURAL TROIS VOIES IMPORTANT Ce produit doit tre utilis avec le r cepteur d interrupteur mural Un c blage de circuit a trois voies est n cessaire pour installer et utiliser ce produit Note Si vous n tes pas familier avec le c blage lectrique consultez un lectricien avant d effectuer l installation De plus le code de l lectricit local pourrait exiger Retrait de l onglet du compartiment pile que l installation soit confi e un lectricien qualifi Installation 3 Appuyez sur le bouton ON bouton de gauche pour allumer 4 Choisissez l interrupteur d clairage qui doit tre remplac par l clairage ou sur le bouton OFF bouton de droite pour le l metteur d interrupteur mural a trois voies fermer Note Le voyant rouge de la t l commande devrait s allumer au moment o vous appuyez sur le bouton IMPORTANT Attendez une ou deux secondes apr s avoir appuy Sur um bouton avant da ppuy
37. er de nouveau dessus pour permettre 3 Retirez la plaque murale et l interrupteur existant Etiquetez les fils la transmission de s effectuer 3 a sur l interrupteur existant selon le sch ma de la Figure 1 Note Le Note Sil clairage ne s allume pas ou s ils allume par intermittence c blage trois voies typique est illustr Le c blage et la couleur lorsque vous appuyez sur un bouton du transmetteur consultez des fils peuvent varier le Guide de d pannage 2 AVERTISSEMENT Coupez l alimentation de l interrup teur avant de commencer Pour ce faire coupez le courant au panneau de disjoncteurs ou la bo te fusibles 598 1135 10 37 Suite SIVONVHS Borne commune vis fonc e nor AUFILSOUS TENSION OU 059 039 AU LUMINAIRE Interrupteur tripolaire AU FIL SOUS TENSION OU AU LUMINAIRE Interrupteur tripolaire NOIR Fil de connexion Fil de connexion VERT terre Y Figure 1 C blage a trois voies typique 4 D branchez les deux fils de connexion le fil raccord a la borne commune et le fil de mise a la terre 5 Enlevez la plaque murale de l metteur d interrupteur mural trois voies A AVERTISSEMENT Les fils blancs du neutre d un circuittripolaire doivent former un circuit continu Lorsque le circuit comprend un tel fil il ne faut pas le raccorder aucun des fils du circuit tripolaire Connectez les f
38. er device Does not respond immediately after installation Signals from transmitter are being blocked or transmitter is out of range Weak battery in the transmitter Dip switches on transmitter and receiver units do not match Device is defective t Verify circuit breaker or fuse is turned on Verify switched device is turned on Change codes on transmitter and receiver units Wait for 90 second initialization period remote motion sensor Check for metal objects that could block the signal or reposition the transmitter Check battery charge and replace if necessary Verify code settings on transmitter and receiver units are set the same Test using different device Device does not turn off Same as 5 6 and 7 above Same as 5 6 and 7 above Device comes on randomly Short term power line failure Another transmitter on the same frequency TECHNICAL SERVICE Next transmission from transmitter will reset receiver to correct state Change codes on transmitter and receiver units Please call 1 800 858 8501 English speaking only for assistance before returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www hzsupport com If the problem persists call for assistance at 1 800 858 8501 English speaking only 7 30 AM to 4 30 PM CST M F You may also write to HeathCo LLC P O Box 90045 Bowling Green KY 42102
39. es receptor es 1 C digo del transmisor es receptor es fi Xx XIXIXIX XXIX Grupo B 4 Grupo A Indica la posici n del interruptor O 2009 HeathCo LLC CARACTER STICAS Productos probados y aprobados por laboratorios UL CUL y o FCC IC Distancia de operaci n hasta 100 pies Los controles inal mbricos Heath Zenith para el alumbrado est n dise ados para trabajar juntos Simplemente determine cual transmisor es le gustar a que controlen tal es receptor es y fije la calibraci n del c digo para emparejar Ejemplo 2 Calibraciones del c digo sistema 2 Nota Cuando opere m s de un sistema independientemente el uno del otro fije cada sistema con un c digo diferente Hay 8 c digos disponi bles al cambiar las calibraciones de los interruptores del 1 al 3 C digo del C digo del receptor es transmisor es 1 X X XXIX XIXIX Grupo A Interruptor del grupo Selecci n Grupo A mostrada Ejemplo 3 Calibraciones del c digo con un nico transmisor Cuando se use un transmisor de s lo un grupo ejemplo Transmisor de puerta interruptor A a adible detector remoto de movimiento las calibraciones de c digo y grupo deben emparejar con los receptor es para que el sistema funcione correctamente C digo del receptor es 1 C digo d
40. es endroits o les animaux domestiques ou le traffic peuvent d clencher la commande Les gros objets de couleur claire situ s proximit et qui refl tent la lumi re peuvent d clencher la fermeture Ne pointez pas d autres lumi res vers le d tecteur D tecteur de mouvements ext rieur Commande j ON TIME ES AO D tecteur de mouve ments int rieur Commandes du d tecteur de mouvement 598 1135 10 150 OO ME T Sin Dirigez le d tecteur Dirigez le d tecteur vers le bas pour une plus haut pour une couverture courte couverture longue Port e maximale Angle de couverture maximal a F R glage de la couverture du d tecteur de mouvements Zone de couverture du d tecteur de mouvements int rieur int rieur A 180 2 4m Y Y Dirigez le d tecteur Dirigez le d tecteur vers le bas pour une plus haut pour une 21m couverture courte couverture longue Port e maximale Angle de couverture maximal R glage de la couverture du d tecteur de mouvements ext rieur Zone de couverture du d tecteur de mouvements ext rieur O D tecteur D tecteur Le moins sensible Le plus sensible Le d tecteur est plus sensible au mouvement travers son champ de vision Sensibilit des d tecteurs de mouvements int rieur et ext rieur SIVONVHS 598 1135 10 35 INTERRUPTEU
41. es mouvements de jour comme de nuit ou de nuit seulement Pour r gler le mode de d tection retirez le couvercle du compartiment des piles en le faisant glisser vers le bas Enlevez les piles si n cessaire Glissez l interrupteur DETECT soit la position DAY NIGHT jour nuit ou a la position NIGHT ONLY nuit seulement Remettez le couvercle du compartiment des piles en place en le faisant glisser vers le haut Installation des piles Avant d installer le d tecteur de mouvements ext rieur retirez le couvercle du compartiment pile en le faisant glisser vers le bas S il s agit du d tecteur de mouvements int rieur mettez les piles en place une fois le d tecteur install Installez 2 piles AA en fonction des rep res de polarit se trouvant a l int rieur du compartiment des piles Remettez le couvercle du com partiment des piles en place en le faisant glisser vers le haut Commande de d tection sey Frans elo 4 l D tecteur de mouvements ext rieur arri re D tecteur de mouvements int rieur avant Compartiment des piles Installation du d tecteur de mouvements int rieur au moyen du support de montage facultatif Note Installer le d tecteur de mouvements de fa on pouvoir le pointer vers le haut ou vers le bas pour obtenir la zone de couverture d sir e 1 Fixez le support pivotant
42. ground wire in junction box Connect the black wire on receptacle to the load wire in junction box and connect the white wire on receptacle to the neutral wire in the junction box Connections should appear as shown in illustration Before installing fixture make sure there is no wire exposed at connections 3 Mount receptacle in junction box with the two screws long provided Note Verify the receptacle marked CONTROLLED is on top 4 Screw on cover plate with the two screws short provided Junction Box Receptacle Receptacle Wall Plate Screw Ground Wire Bare or Green Wall Plate Controlled Outlet Installing Receptacle Receiver Testing and Operation Follow the steps below to operate and test the receptacle receiver using a remote control device 1 Set the proper channel codes on both the transmitter and receiver modules see Code Settings 2 Plugin the light fixture to be controlled in the top receptacle Note If installed properly the top receptacle will be marked with the word CONTROLLED below it 3 Operate the ON OFF buttons on the remote to verify operation Light should turn ON and OFF as the appropriate button is pressed Note DIM is not available on this switch JOERIE SYMPTOM TROUBLESHOOTING GUIDE POSSIBLE CAUSE SOLUTION Device does not come on i 2 3 Circuit breaker or fuse is turned off Switch on device is turned off Interrupted by anoth
43. i n cuando el LED empiece a destellar Afloje el tornillo de la abrazadera y mueva el detector para cambiar el rea de cobertura Cuando termine apriete el tornillo de la abrazadera No apriete excesivamente este tornillo Regule el control de alcance Para incrementar la sensibilidad gire el control de ALCANCE hacia MAX Para disminuir la sensibilidad g relo hacia MIN Nota En algunos ambientes si el ALCANCE se calibra demasiado alto puede ocurrir una falsa activaci n Nota Cuando use el modo de prueba Test para comprobar el funcionamiento durante el d a A Ponga el interruptor del control DETECT DETECTAR a DAY NIGHT NOCHE D A y B Ponga el control ON TIME DURACI N a TEST Fije el control de DURACI N Determine la cantidad de tiempo que desea que el dispositivo conectado permanezca encendido luego que se detecta movimiento 1 5 minutos Mueva el control de DURACI N a la configuraci n correspondiente IMPORTANTE Evite apuntar el control Objetos que cambian r pidamente latemperatura como sopladeros de la calefacci n ventiladores y acondicionadores de aire Estas fuentes de calor podr an ocasionar una activaci n falsa A reas en donde las mascotas o el tr fico pueden activar el control En las cercan as de objetos grandes pintados con colores claros cuyo reflejo puede activar el apagado No enfoque otras luces al detector Z calo de la consola Consola de montaje de montaje
44. ies 2 Place indoor motion sensor against surface to be mounted on Using two of the holes on the rear of the battery compartment mark hole locations with pencil or center punch 3 Using a 2 5 mm 0 1 drill bit drill two pilot holes for mounting screws If not mounting directly to wood or wood stud drill 5 mm 0 2 pilot holes and use the included wall anchors 4 Attach indoor motion sensor to a sturdy object i e wall cabinet post etc using two screws provided Make sure unit has an unobstructed view IMPORTANT Hand tighten only do not overtighten Za A Counter Motion Sensor Mounting Screw Le Attaching Indoor Motion Sensor Directly to Wall 598 1135 10 Installing Outdoor Motion Sensor 1 Install sensormounting bracketwhere motion detection is desired Attach sensor mounting bracket to a sturdy object i e tree post house etc using two screws provided Make sure unit has an unobstructed view Note Attach mounting bracket vertically if connecting to a curved surface such as a post 2 Install motion sensor to mounting bracket Using a Philips head screwdriver loosen the clamp screw on the mounting bracket Insert swivel ball mount on sensor into mounting bracket socket Note You should hear a snap Aim sensor toward area where detection is desired Tighten clamp screw IMPORTANT The sensor must be mounted with the bottom cover facing down in order
45. ieure ce qui est inscrit dans les caract ristiques plus haut 598 1135 10 PRISE RECEPTRICE Fonctions et caract ristiques Commande d une ampoule incandescente de puis sance de 1800 W Commande l allumage extension de l clairage Peut convenir des charges maximum de 15 A Installation 1 Retirez la prise existante de la bo te de connexion au besoin 2 Raccordezle fil vert de la prise r ceptrice au fil vert de la bo te de connexion Raccordezle fil noir dela prise aufil d alimentation de la bo te de connexion puis raccordez le fil blanc de la prise au fil neutre de la bo te de connexion Respectez l ordre de connexion indiqu dans l illustration Avant d installer l appareil assurez vous qu aucun fil d nud n est expos 3 Installez la prise dans la bo te de connexion au moyen des deux grandes vis fournies Note Assurez vous que la prise portant l appellation CONTROLED est situ e en haut 4 Installez la plaque murale au moyen des deux petites vis fournies Boite de connexion Prise r ceptrice Vis de la prise Vis de plaque murale y Plaque A murale Fil de mise a la terre d nud ou vert Prise command e Installation de la prise r ceptrice 598 1135 10 41 Essai et fonctionnement Suivez les tapes ci dessous pour faire l essai et l utilisation de la prise r ceptrice au moyen d une t l commande 1 Programmez le code de canal appropri
46. ils de l metteur de l interrupteur mural trois voies aux fils dans la bo te de jonction tel qu indiqu la Figure 2 Utilisez les connecteurs de fils fournis pour fixer les fils voir Figure 2 Note Lun ou l autre des fils noirs du transmetteur peut tre raccord au fil sous tension luminaire ou au fil de connexion Connectez le fil vert de mise la terre de l metteur au fil de mise la terre enlev de l ancien interrupteur Servez vous des connecteurs fournis pour fixer les fils ensemble voir Figure 3 Assurez vous queles fils sont solidement branch s et qu aucune partie d nud e n est expos e Placezl metteur de l interrupteur mural dans la bo te de jonction avec le bouton gradateur situ droite Utilisez les deux vis d interrupteur mural longues fournies pour fixer l metteur la bo te de jonction voir Figure 3 Ce faisant poussez le c blage en exc s dans la bo te de jonction en pliant les fils au besoin Montez la plaque murale l metteur de l interrupteur mural l aide des vis courtes fournies Pour installer le r cepteur de l interrupteur mural r p tez les tapes 5 10 ci dessus Note Faites passer l antenne entre le bas de la bo te de connexion et le mur Ins rez l antenne dans la cavit murale en repla ant le transmetteur dans la bo te de connexion 10 11 38 IMPORTANT Identifiez les fils de l interrupteur tripolaire existant conform ment au diagramme de la
47. interrupteurs Micro interrupteurs Prise r ceptrice murale 30 Micro interrupteurs D tecteur de mouvements sans fil ext rieur Micro interrupteurs Interrupteur mural a trois voies On K X R Note Le X plac sur les micro inter rupteurs vise pr ciser la position la page pr c dente Vue rapproch e d un micro interrup teur r glage en usine la position OFF 598 1135 10 TELECOMMANDE Note Une t l commande peut commander ind pendam ment deux r cepteurs S il l on veut faire fonctionner plus de deux r cepteurs de fa on ind pendante il estn cessaire de se procurer des t l commandes additionnelles 1 Enlevez la languette du compartiment des piles Enlevez le couvercle l arri re du transmetteur Tirez douce ment la languette hors du compartiment des piles Glissez le couvercle sur le transmetteur Compartiment des Roos Pos piles Type A23 HE cm GH Languette Couvercle des piles Vue arri re de la t l commande 2 Fonctions de la t l commande Les trois boutons du c t gauche de la t l commande peuvent commander au moins un r cepteur dot des m mes r glages de code Les trois boutons du c t droit de la t l commande font fonctionner un deuxi me ensemble d un ou de plusieurs r cepteur s ON Active tout r cepteur dot de
48. ior retire la tapa del compartimiento de la bater a desliz ndola hacia abajo Endetectores de movimiento para uso interior instale las bater as luego de colocar el detector Coloque las dos bater as AA seg n la polaridad marcada dentro del compartimento de la bater a Vuelva a colocar el compartimiento de la bater a siguiendo a la inversa las instrucciones indicadas 598 1135 10 17 Control detector E mo Pele ln o fl p Detector de movimiento para uso exterior Vista posterior Detector de movimiento para uso interior Vista frontal Compartimento de la bateria Instalaci n del detector de movimiento para uso interior usando el soporte opcional de montaje Nota Instale el detector de movimiento para uso interior de modo que pueda girar hacia arriba o hacia abajo y asi darle la cobertura deseada por encima del nivel del suelo 1 Fije la consola de montaje tipo bola a la parte posterior del detector de movimiento La consola de montaje tipo bola est dise ada para instalarse en la parte posterior del detector en tres direcciones posibles dependiendo de lo requerido por la instalaci n Para sujetar la consola de montaje tipo bola siga los pasos que se indican Determine la posici n ptima de montaje del detector para obtener la cobertura deseada Determine el sitio ptimo
49. llum e 3 Appuyez sur le bouton OFF partie du bas puis rel chez le L clairage devrait s teindre 4 Appuyez sur la partie sup rieure ou inf rieure du bouton DIM puis relachez le L clairage devrait s allumer 50 de l intensit maximum ou en fonction du dernier r glage utilis 5 Appuyez sur la partie sup rieure du bouton DIM pour augmenter l intensit Appuyezsurla partie inf rieure du bouton DIM pour diminuer l intensit de l clairage Note Le bouton DIM comprend cinq degr s de r glage de l intensit qui varie de 15 90 6 R glez l clairage l intensit d sir e Note Le rh ostat m morise le dernier r glage utilis Pour le rappeler au moyen de l interrupteur appuyez sur la partie sup rieure ou inf rieure du bouton DIM puis rel chez le Note En cas de panne de courant le r glage de l intensit revient automatiquement 50 NOTICE Lorsque le bouton de MARCHE du r cepteur d interrupteur mural est utilis pour mettre les luminaires en marche les commandes d ARR T envoy es par tout transmetteur seront ignor es Lorsque le bouton d ARR T du r cepteur est enfonc les luminaires s teindront et le r cepteur acceptera nouveau des commandes MARCHE ARR T du transmetteur Remplacement de l ampoule Placez l interrupteur d alimentation en position OFF du c t gauche Remplacez l ampoule AR ATTENTION Evitezd utiliser une ampoule de puissance sup r
50. me suit 300W 300W 300 W 300 W 500 W 500 W 450 W 400 W 598 1135 10 39 Suite SIVONVHS Installation 1 S lectionnez l interrupteur remplacer 2 AVERTISSEMENT Coupez alimentation de l interrup teur avant de commencer Pour ce faire coupez le courant au panneau de disjoncteurs ou la bo te fusibles 3 Retirez la plaque murale et l interrupteur existant D branchez les deux fils d alimentation et le fil de mise la terre Note S il y a plus de deux fils d alimentation raccord s l inter rupteur consultez un lectricien pour proc der l installation De plus le code de l lectricit local pourrait exiger que l installation soit confi e un lectricien qualifi ATTENTION Ne raccordez pas le fil neutre blanc interrupteur 4 Si n cessaire d nudez 1 2 po d isolant l extr mit des fils 5 Raccordez l un des fils noirs d alimentation du transmetteur lun des fils d alimentation d branch s de l ancien interrupteur Servez vous des connecteurs fournis pour fixer les fils ensemble voir l illustration 6 Raccordez le second fil noir du transmetteur l autre fil d ali mentation d branch de l ancien interrupteur Servez vous des connecteurs fournis pour fixer les fils ensemble voir l illustration 7 Raccordez le fil vert de mise terre du transmetteur au fil de mise la terre de l ancien interrupteur Servez vous des connecteurs fournis pour fixer les fil
51. mon terminal and the ground wire 5 Remove the wall plate from the 3 way wall switch transmitter A WARNING The white neutral wires in a 3 way circuit must run continuously through the entire circuit If pres ent do not connect a white neutral wire to either of the 3 way switch wires 598 1135 10 6 Connect the wires of the 3 way wall switch transmitter to the wires in the junction box as shown in Figure 2 Use the supplied wire connectors to secure the wires see Figure 2 Note Either black wire on the transmitter can be used to connect to the hot wire light or traveler wire 7 Connect the green ground wire from transmitter to the ground wire removed from old switch Use one of the supplied wire connectors to secure the wires see Figure 3 8 Check wire connections to make sure they are secure and that no bare wires are exposed 9 Position the wall switch transmitter in the junction box with the DIM button located to the right Use the two wall switch screws long supplied to mount the transmitter to the junction box see Figure 3 Push excess wiring into junction box while you do this bending the wires to fit if necessary 10 Mount the wall plate to the wall switch transmitter with the screws short provided 11 To install the wall switch receiver repeat steps 5 through 10 above Note Route antenna between the bottom of the junction box and the wall Feed antenna into wall cavity while placing wall swit
52. n 1 Verifique que el desconectador de energ a del transmisor y receptor est n en la posici n ON lado derecho Pulse y suelte el bot n ON parte superior La luz deber a encenderse con luminosidad total Nota Si est controlando una l mpara aseg rese que est conectada a untomacorriente con interruptor y que la l mpara est encendida Pulse y suelte el bot n OFF parte inferior La luz deber a apagarse Pulse y suelte el bot n REDUCTOR DIM La luz deber a encen derse al 50 de su luminosidad o seg n la ltima calibraci n Nota El receptor memoriza el ultimo ajuste del REDUCTOR usado Para mostrar el ultimo ajuste del REDUCTOR pulse y suelte el bot n REDUCTOR Siga presionando el bot n REDUCTOR hasta alcanzar el nivel REDUCTOR deseado Nota Hay 5 calibraciones del atenuador que van del 15 al 90 de la luminosidad Nota En caso de una falla de energ a la calibraci n del atenuador se fija en el ajuste hecho en f brica del 50 IMPORTANTE Espere de 1 a 2 segundos despu s de pulsar el bot n de un transmisor antes de pulsarlo de nuevo para permitir que la transmisi n se complete Nota Si la luz no se prende o si se prende y apaga intermitente mente cuando se pulsan los botones del transmisor vea la Gu a de An lisis de Aver as Reemplazo de la bombilla Mueva el desconectador de alimentaci n del transmisor y del receptor a la posici n APAGADO lado izquierdo Reemplace la s bombilla s Nota el desconec
53. ng Bracket to Indoor Motion Sensor Vertical Installation Shown 2 Place sensor mounting bracket against surface to be mounted on and mark hole locations with pencil or center punch 3 Using a 2 5 mm 0 1 drill bit drill two pilot holes for mounting screws If not mounting directly to wood or wood stud drill 5 mm 0 2 pilot holes and use the included wall anchors 4 Attach indoor motion sensor mounting bracket to a sturdy object i e wall ceiling post etc using two screws provided Make sure unit has an unobstructed view Note Attach mounting bracket vertically if connecting to a curved surface such as a post Install motion sensor to mounting bracket Using a Philips head screwdriver loosen the clamp screw on the mounting bracket Insert swivel ball mount on sensor into mounting bracket socket 598 1135 10 Note You should hear a snap Aim sensor toward area where detection is desired Tighten clamp screw Mounting Screw Mounting Bracket Socket Mounting Bracket f Clamp A Screw y Swivel Ball Mount Battery Compartment Sensor Cover Attaching Indoor Motion Sensor to Mounting Bracket Installing Indoor Motion Sensor Directly To Wall Note Mount the indoor motion sensor so that it is approximately between waist and shoulder level above the floor Example Level with light switch under counter top etc 1 Determine the best mounting position of the sensor for the coverage desired Remove the batter
54. no de los conductores que van al interruptor tridireccional 6 Conecte los conductores del transmisor con conmutador tridi reccional a los conductores de la caja de empalmes como se muestra en la figura 2 Para empalmar estos conductores use los conectores para conductores que se provee vea la Figura 2 Nota Cualquiera de los conductores negros del transmisor pueden usarse para conectar al conductor vivo o fase o a la l mpara o al conductor retorno 7 Conecte el conductor verde de conexi n a tierra del transmisor al conductor de conexi n a tierra que se retir del interruptor viejo Use uno de los conectores de alambre provistos para asegurar los conductores vea la Figura 3 8 Reviselasconexiones delosconductores paraasegurarse queest n bien hechas y que no haya conductores desnudos a la vista 9 Coloque en la caja de empalme el transmisor de pared con interruptor con el bot n REDUCTOR a la derecha Use los dos tornillos provistos largos del interruptor de pared para montar el transmisor a la caja de empalme vea la Figura 3 Empuje los conductores excedentes hacia la caja de empalme Mientras hace esto y si es necesario doble los conductores para que encajen 10 Coloque la placa de pared en el transmisor de pared con interruptor usando los tornillos provistos cortos 11 Para instalar el receptor de pared con interruptor repita los pasos de arriba del 5 al 10 Nota Gu e la antena entre la parte inferior
55. nsola de montaje Nota Usted deberia oir un chasquido un clic Apunte el detector hacia el area que se requiere detectar Apriete el tornillo de la abrazadera Revisi n de la operaci n y de la regulaci n Nota Cuando lo prenda por primera vez o cuando cambie de modalidad espere 1 2 minutos Localice en el detector de movimiento los controles de ALCANCE y DURACI N Detector de movimiento para uso interior Los controles de ALCANCE y DURACI N est n dentro del compartimiento de la bater a en la parte frontal del detector Para fijar el control de ALCANCE o el de DURACI N retire la tapa del compartimiento de la bater a desliz ndola hacia abajo Detector de movimiento para uso exterior Los controles de ALCANCE y DURACI N est n ubicados en la parte inferior del detector Usando las u as de los dedos o un destornillador peque o de cabeza plana haga suavemente palanca en la tapa hasta que se abra Revise la operaci n Ponga el control de DURACI N en el modo IMPORTANTE El detector debe estar montado con la tapa inferior hacia abajo con el fin de mantener la hermeticidad contra el agua TEST PRUEBA Camine frente a la unidad detectora La luz indicadora LED debe destellar cuando se detecta movimiento vea la ilustraci n de la p gina 20 para ubicar la luz LED Regule el detector Gire el control de ALCANCE a la posici n media y el de DURACI N a la posici n TEST Camine por el rea de cobertura y note su posic
56. nt du voyant DEL 34 2 R glezled tecteur Tournezlacommande RANGE la position centrale et la commande ON TIME a la position TEST Marchez dans la zone de couverture en notant l endroit o vous tes lorsque le voyant DEL commence clignoter Desserrez la vis de serrage et d placez le d tecteur pour changer la zone de couverture Serrez la vis de serrage lorsque vous avez termin Ne serrez pas trop la vis de serrage R glez la commande dela port e Pour augmenter la sensibilit tournez la commande RANGE vers MAX Pour diminuer la sensibilit tourner la commande RANGE MIN Note Si la commande RANGE estr gl e trop haut ceci pourrait causer un faux d clenchement dans certains environnements Note Lors de l utilisation du mode Test pour v rifier le fonc tionnement pendant le jour A R gler le commutateur DETECT DAY NIGHT puis B R gler la commande ON TIME TEST R glez la commande ON TIME D terminez pendant combien de temps vous voulez que le dispositif connect reste allum apr s que le mouvement ait t d tect 1 ou 5 minutes Glissez la commande ON TIME vers le r glage correspondant IMPORTANT vitez de diriger la commande vers Des objets qui changent rapidement de temp rature notamment vents de chauffage ventilateurs appareil de conditionnement de Pair Ces sources de chaleur peuvent causer un faux d clen chement L
57. oduit Veuillez conserver le re u portant la date d achat vous en aurez besoin pour toutes vos demandes li es la garantie 42 598 1135 10 RENSEIGNEMENTS DE REGLEMENTS Ce dispositif est conforme aux exigences de la partie 15 des r gles FCC et RSS 210 d Industrie Canada Son fonctionnement est sujet aux deux conditions suivantes 1 Ce dispositif ne doit pas causer de parasites nuisibles et 2 ce dispositif doit endurer tous les parasites re us y compris ceux susceptibles de provoquer un fonctionnement intempestif Avis l utilisateur Les changements ou modifications qui n ont pas t explicitement approuv s par l organisme charg d assurer la conformit aux r glements pourraient invalider le droit de l utilisateur faire fonctionner cet appareil GARANTIE LIMIT E DE 2 ANS Il s agit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits variables d une province l autre Pendant une p riode de 2 ans compter de la date d achat toute anomalie de fonctionnement imputable un vice de mat riau ou de main d oeuvre sera corrig e gratuitement Exclusions de la garantie R parations r glage et calibrage dus une mauvaise utilisation un mauvais traitement ou la n gligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autoris ou la modification du produit ou d un ou l
58. ola de montaje verticalmente si lo instala a una superficie curva como un poste Instale el detector de movimiento a la consola de montaje Usando un destornillador cabeza Philips afloje el tornillo de la abrazadera en la consola de montaje Inserte la montura giratoria de bola del detector en el z calo de la consola de montaje Nota Usted deber a o r un chasquido un clic Apunte el detector hacia el rea que se requiere detectar Apriete el tornillo de la abrazadera Z calo de la consola Tuerca Tornillo de la abrazadera Tornillo de montaje de montaje A es acl Consola de 7 a montaje S3 gt 9 2 oi a Montura giratoria de bola i Tapa del compartimiento Detector de la bateria Sujeci n del detector de movimiento para uso interior a la consola de montaje 18 Instalaci n del detector de movimiento para uso interior directamente en la pared Nota Instale el detector de movimiento para uso interior de modo que quede aproximadamente a una altura sobre el suelo entre la cintura y los hombros Ejemplo Al mismo nivel o altura que un interruptor de luz debajo de la superficie superior del mostrador etc 1 Determine la posici n ptima de montaje del detector para obtener la cobertura deseada Retire las bater as Coloque el detector de movimiento para uso interior sobre la su perficie que lo va a instalar Usando dos de los orificios posteriores del compartimiento de la bater a marque con un l
59. ons on the right side of the remote will operate a second set of one or more receiver units ON Turns on any receiver unit set to the same code as this remote control OFF Turns off any receiver unit set to the same code as this remote control DIM Activates the DIM feature for any receiver unit set to the same code as this remote control Note Pressing the DIM button steps through five brightness levels 598 1135 10 Note To independently operate a second receiver unit using a single remote control make sure the second set of code switches Right Side and the code switches on each receiver match see Code Settings section Left Side Set left side code switches Right Side Set right side code switches ENX Right Side DIM a Left Side DIM ee J Nd Right Side ON Left Side ON E eItsido LIIV right Side OFF Left Side OFF U Function Controls IMPORTANT Wait 1 to 2 seconds after you press a transmitter button before you press it again to allow the transmission to be completed Note If light does not turn on or intermittently turns on and off when transmitter buttons are pushed see Troubleshooting Guide Optional Car Visor Clip Included The remote control includes an optional car visor clip for added convenience that may be installed 1 To attach car visor clip to remote control if desired push it into slot on rear of remote unit until it snaps into place 2 To remove car visor clip insert a
60. oo witches witches A Battery Cover eae Remote Control Code Br Smitones gt le o A Access Door Add A Switch Code Switches Wall Switch Receiver CODE SWITCH LOCATIONS Code i lt Switches Indoor Wireless Motion Sensor Code o Switches ls a lt ix jI ae elo Kid s Remote Control Code Switches N al S Receptacle Receiver Code Switches Outdoor Wireless Motion Sensor Code Switches 3 Way Wall Switch Transmitter ON Note The X has been placed on the switches to help clarify the code settings on the previous page Close Up of Typical Code Switch Factory Default Setting is Off 598 1135 10 REMOTE CONTROL Note One remote control is able to independently operate two receiver units If more than two receiver units operating independently are desired additional remote controls will need to be purchased de Remove Tab from Battery Chamber Remove cover from back of transmitter Gently pull tab out of battery chamber Slide cover onto transmitter A x Battery Chamber Tab Type A23 Sa Battery Cover Rear View of Remote Control 2 Remote Control Functions The three buttons on the left side of the remote will operate one or more receiver units with matching code settings The three butt
61. percer deux trous de 5 mm 0 2 po et utiliser les ancrages muraux fournis Fixer le support de montage du d tecteur de mouvements int rieur un objet solide p ex mur plafond poteau etc au moyen des deux vis fournies Assurez vous que le d tecteur n a pas la vue obstru e Note Fixez le support de montage la verticale lorsqu il s agit d une surface incurv e par exemple d un poteau Installez le d tecteur de mouvement au support de montage l aide d un tournevis pointe cruciforme desserrez la vis de serrage sur le support de montage Ins rez la monture rotule sur le d tecteur dans la douille du support de montage Note Vous devriez entendre un claquement Dirigez le d tecteur vers la zone o vous voulez d tecter le mouvement Serrez la vis de serrage DE de montage de montage Vis de serrage 3 Monture rotule D tecteur des piles Installation du d tecteur de mouvements int rieur sur le support de montage 598 1135 10 33 Installation du d tecteur de mouvements int rieur directement au mur Note Installer le d tecteur de mouvements int rieur une hauteur situ e entre la taille et les paules p ex A la hauteur des interrup teurs d clairage sous la ligne du dessus de comptoir etc 2 D terminer le meilleur endroit pour le capteur compte tenu de la couverture d sir e Retirer les piles Placer le d tecteur de mouvementes int rieurs sur la
62. pliez doucement l on glet de verrouillage vers u ee l ext rieur La pile sortira de della le son logement m pi 3 Retirez la pile du socle ly e 4 Installez la pile de rempla A cement dans le socle le signe plus surle dessus Couvercle Pile au voir l illustration Appuyez d acc s lithium doucementsur la pile jusqu CR2032 ce que l ongletde verrouillage s enclenche 5 Replacez la porte d acc s Retrait de la porte d acc s en la faisant glisser vers le de la pile haut jusqu ce qu elle se verrouille 598 1135 10 TELECOMMANDE POUR ENFANT Remplacement de la pile Fonctionnement La t l commande exige une pile alcaline 12 V de type A23 Lors de 1 Assurez vous que le r cepteur est bien ins son exp dition la t l commande comprend une pile En condition tall Consultez la section Informations sur le d utilisation normale la pile devrait durer environ un an Retirez r cepteur la page 38 la pile si vous ne pr voyez pas utiliser la t l commande pour une p riode prolong e Suivez les directives ci dessous pour remplacer la pile Arri re de la 1 Retournez la t l commande l envers L t l commande 2 Retirezlavis de la porte d acc s de la t l commande au moyen ee d un petit tournevis Philips 3 Retirez la porte d acc s et mettez la de c t 4 Retirez la pile puis installez la pile de remplacement Assurez vous qu elle est ori
63. production de ses produits ou d en modifier les sp cifications tout moment et elle n est pas tenue d incorporer les nouvelles caract ristiques de ses produits aux produits vendus ant rieurement SIVONVHS 598 1135 10 43 Heat Zemth Purchase Information Informaci n de la compra Renseignements d achat Model Date of Purchase N de modelo N de mod le Fecha de compra Date d achat Staple Purchase Receipt Here Engrape aqui el recibo de compra Agrafez le re u d achat ici PLEASE KEEP YOUR DATED SALES RECEIPT IT IS REQUIRED FOR ALL WARRANTY REQUESTS POR FAVOR GUARDE SU RECIBO DE VENTA FECHADO SE LO REQUIERE PARA CUALQUIER SOLICITUD DE GARANTIA VEUILLEZ CONSERVER LE RE U PORTANT LA DATE D ACHAT VOUS EN AUREZ BESOIN POUR TOUTES VOS DEMANDES LIEES A LA GARANTIE 44 598 1135 10
64. r que est dentro de la ranura mientras desde arriba hala la presilla hacia fuera del control Presilla opcional del visor Destornillador plano Retiro de la presilla del visor Vista posterior 598 1135 10 DETECTOR INALAMBRICO DE MOVIMIENTO PARA USO INTERIOR Y EXTERIOR Detector inalambrico de movimiento para uso exterior Detector inalambrico de movimiento para uso interior Caracteristicas No se requiere cableado Margen de sensibilidad hasta 21 m 180 de cobertura Exterior Margen de sensibilidad hasta 9 1 m 150 de cobertura Interior Sensibilidad ajustable Operaci n diurna nocturna o s lo nocturna Modo prueba Usa dos bater as AA Montaje en pared o alero Exterior Puede instalarse directamente en la pared o usando un soporte de montaje incluido Interior Controla los receptores hasta 30 m de distancia Seleccione modo nocturno o modo de 24 horas Estos detectores pueden detectar movimiento durante el d a o la noche o s lo por la noche Para fijar el modo de detecci n retire la tapa del compartimiento de la bater a desliz ndola hacia abajo Si es necesario retire las bater as Mueva el interruptor DETECT DETECTAR ya sea ala posici n DAY NIGHT ala posici n NIGHT ONLY S LO NOCHE Vuelva a colocar el compartimiento de la bater a siguiendo a la inversa las instrucciones indicadas Instalaci n de las bater as Antes de montar el detector de movimiento para uso exter
65. ra una variedad de productos a control remoto Todos los productos funcionan bas ndose en el mismo principio y usan la misma informaci n para la calibraci n del c digo Por favor lea todas las instrucciones y tome en cuenta cualquier informaci n espec fica relativa a su producto en particular Este manual sirve para los siguientes productos Transmisores Receptores Control remoto Receptor de pared con Detectorinal mbrico de movimiento interruptor para uso interior Receptor con tomaco Detector inal mbrico de movi rriente miento para uso exterior Interruptor A a adible Control remoto para ni os Conmutador tridireccional de pared CALIBRACIONES DEL C DIGO Nota La mayor a de instalaciones de s lo un sistema no reque rir n ning n cambio en la calibraci n del c digo Para que fun cionen juntos los transmisor es y los receptor es deben tener la misma calibraci n de c digo y de grupo Los interruptores del 1 al 3 fijan el c digo El interruptor 4 fija el grupo A o B Vea en la p gina 15 la ubicaci n de los interruptores Ejemplo 1 Calibraciones del c digo sistema 1 calibraci n de f brica Controles del E Controles del lado lado izquierdo 2 SA derecho Controla un Controla un juego de E K juego de receptores receptor es del gru on on del grupo A o grupo po A o grupo B Br ale l Los 4 C digo del transmisor
66. re it is connected to the switched outlet and the lamp is switched on 3 Push the OFF bottom button and release The light should turn off 4 Push either the top or bottom of DIM button and release The light should turn on at 50 brightness or last setting 5 Push and release top of DIM button to increase brightness Push and release bottom of DIM button to decrease bright ness Note There are 5 DIM settings ranging from 15 to 90 brightness 6 Set desired DIM level Note DIM setting remembers last set ting used To recall last DIM setting from ON or OFF push and release either the top or bottom of DIM button Note The DIM setting defaults to 50 in the event of a power failure NOTICE When the wall switch receiver s ON button is used to turn the lights on OFF commands sent by any transmitter will be ignored When the receiver s OFF button is pushed the lights will go off and the receiver will once again accept a transmitter s ON OFF commands Bulb Replacement Move the power disconnect switch to the OFF left side position Replace bulb s CAUTION Do not exceed the maximum load limits listed above 598 1135 10 11 RECEPTACLE RECEIVER Features and Ratings Control up to 1800 Watts of incandescent load e Controls the ON OFF function in lighting Controls up to 15A loads Installation 1 Remove existing receptacle from junction box if necessary Connect green wire from receptacle to
67. riba Atornille la placa cubertora usando los dos tornillos cortos provistos Caja de empalme Tomacorriente Tornillo del tomacorriente Tornillo de la placa de pared P Cable de conexi n a tierra desnudo o verde 9 Tomacorriente controlado Instalaci n del receptor con tomacorriente 26 Prueba y operaci n Siga los pasos siguientes para operar y probar el receptor con tomacorriente usando el dispositivo a control remoto 1 Fije los c digos de canal apropiados tanto en el m dulo transmisor como receptor vea Calibraciones del C digo 2 Enchufe al tomacorriente superior el artefacto de luz que va a controlarse Nota Sise instala adecuadamente eltomacorriente superior tendr debajo la marca CONTROLADO 3 Opere los botones ON OFF en el control remoto para verificar la operaci n La luz deber a encenderse y apagarse al presionar los botones correspondientes Nota La ATENUACI N no est disponible en este interruptor 598 1135 10 S NTOMA GU A DE AN LISIS DE AVER AS CAUSA PROBABLE SOLUCI N El dispositivo no se enciende 1 Eldisyuntoro el fusible est desconec tado 2 El interruptor del dispositivo est desconectado Interrumpido por otro dispositivo Noresponde inmediatamente luego de la instalaci n Las se ales desde el transmisor est n siendo bloqueadas 0 el transmisor esta fuera de alcance Bateria desgastada en el transmisor Los inte
68. risk of overheating and pos sible damage to other equipment do not install to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance Important Information Regarding 3 Way Switch Installations In order to use this product where two switches are being used to control the light the 3 Way Wall Switch transmitter will also have to be installed Refer to the 3 Way Wall Switch Installation section for details Important When ganging these units they must be derated as follows Installation 1 Select light switch to be replaced by wall switch receiver WARNING Turn off the power to the light switch circuit before you proceed Do this at your circuit breaker or fuse box Remove the existing wall plate and switch Disconnect the two power wires and the ground wire Note If there are more than two power wires attached to the switch consultan electrician about installation In addition some local build ing codes may require installation by a qualified electrician 3 CAUTION Do not connect neutral white wire to switch 10 If necessary strip away 1 2 of insulation from end of wires Connect one of the black power wires from receiver to one of the power wires you removed from the old switch Use one of the supplied wire connectors to secure the wires see illustration Connect the second black power wire from receiver to the other power wire you remo
69. ro interrupteur de groupe S lection du groupe A illustr e Exemple 3 R glage des codes avec un seul transmetteur Lors de l utilisation d un seultransmetteurde groupe p ex transmetteur la porte interrupteur d appoint d tecteur de mouvement distance les r glages du code et du groupe doivent tre identiques ceux des r cepteurs pour que le syst me fonctionne correctement Code des Code du d tecteur de R cepteurs mouvement distance 1 1 XIX XIX Groupe A Groupe A Note Le syst me ne fonctionne pas comme dans les exemples 1 et 2 parce que le r glage des codes est diff rent Note Il est possible de modifier le code pour r duire les interf ren ces provenant d autres produits sans fil p ex t l phone sans fil t l commande d ouverture des portes de garage etc Consultez le Guide de d pannage pour plus de d tails 598 1135 10 F SIVONVHS EMPLACEMENT DES MICRO INTERRUPTEURS Commuta L J Commuta teurs des Tees Fer teurs des codes du codes du c t gauche El c t droit Couvercle des piles T l commande pa Couvercle Micro d acc s interrupteurs Transmetteur d appoint Micro al interrupteurs magi Interrupteur r cepteur mural Micro interrupteurs D tecteur de mouvements sans fil int rieur Micro o
70. rruptores de circuito impreso en el transmisor y los receptores no emparejan El dispositivo esta defectuoso 2 Verifique que el disyuntor o el fusible est conectado Verifique que el dispositivo controlado con interruptor est encendido Cambie los c digos en las unidades trasmisora y receptora Espere los 90 segundos del per odo de iniciaci n detector remoto de movimiento Revise objetos met licos que podr an bloquear la se al o vuelva a poner el transmisor en posici n Revise la carga de la bater a y reemplace si es necesario Verifique que la calibraci n del c digo de las unidades transmisora y receptora sean iguales Pruebe usando un dispositivo dife rente El dispositivo no se apaga Igual que el 5 6 y 7 anteriores Igual que el 5 6 y 7 anteriores El dispositivo se enciende al azar Falla de corta duraci n en la l nea de alimentaci n Otro transmisor en la misma frecuencia SERVICIO T CNICO La siguiente transmisi n desde el transmisor reconfigurar al receptor a su estado correcto Cambie los c digos en las unidades transmisora y receptora Favor de llamar al 1 800 858 8501 s lo para hablar en ingl s para pedir ayuda antes de devolver el Si tiene alg n problema siga esta gu a Usted puede tambi n visitar nuestro sitio Web www hzsupport com Si el problema contin a producto a la tienda llame al 1 800 858 8501 s lo para hablar en ingl s
71. rtment cover by reversing the above instructions Detect Control gt p gt lt e fla Sa Ere HET o Aay Eren a el 4 En la El p Outdoor Motion Sensor Indoor Motion Sensor Rear View Front View Battery Compartment Installing Indoor Motion Sensor Using Optional Mounting Bracket Note Mount the indoor motion sensor so that it can be angled up or down to give you the desired coverage above the floor level Attach ball mounting bracket to rear of motion sensor The ball mounting bracket is designed to mount to the rear of the sensor in three possible directions depending upon the installation requirements To attach the ball mounting bracket follow the steps shown below Determine the best mounting position of the sensor for the coverage desired Determine the best location of the wall mounting bracket Insertthe tabs on the ball mounting bracket into the tab slots on the rear of the sensor that best align the sensor with the wall mounting bracket Remove the batteries Using aphilips head screwdriver insert mounting screw into the hole in the battery compartment that aligns with the hole on the rear of the ball mounting bracket Tighten securely R f Si Ball Mounting ear of Sensor Bracket Screw L Tab Slots Tab Swivel Ball Mount Ball Mounting Bracket Attaching Ball Mounti
72. rtura mayor Regulaci n de la cobertura del detector de movimiento para uso exterior 598 1135 10 INTERRUPTOR A ANADIBLE Instalaci n 1 Retire la aleta del compartimiento de la bater a Retire la tapa de la parte frontal del transmisor con interruptor A a adible Retire con suavidad la aleta del compartimiento de la bater a Deslice la tapa en el transmisor interruptor A a adible CT Aleta Compartimiento de la bateria Tipo CR2032 Interruptor A a adible Bot n A L lt atenuador Bot n ON OFF E DIM encendido apagado Tapa de acceso Interruptor A a adible Tapa de acceso 5 Contin e presionando el bot n atenuador DIM hasta alcanzar el nivel de atenuaci n deseado Nota El receptor memoriza la ltima calibraci n de ATENUACI N usada Para volver a la ltima calibraci n pulse y suelte el bot n atenuador DIM Nota En caso de una falla de energ a la calibraci n del atenuador se fija en el ajuste hecho en f brica del 50 Importante Luego de presionar un bot n del transmisor espere de 1 a 2 segundos para presionarlo de nuevo y permitir que se complete la transmisi n Nota Si al presionar los botones del transmisor la luz no se enciende ni lo hace en forma intermitente vea Gu a de An lisis de Aver as Retiro de la aleta de la bater a 2 Seleccione un lugar para instalar el transmisor con interruptor A a adible Nota El transmisor deber a ubicarse hasta 100 pies
73. s de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Por favor guarde su recibo de venta fechado se lo requiere para cualquier solicitud de garant a HeathCo LLC se reserva el derecho de descontinuar productos y de cambiar especificaciones cuando desee sin incurrir en ninguna obligaci n de incorporar las nuevas caracter sticas en los productos vendidos anteriormente 28 598 1135 10 Heati Zenith Produits T l command s Ce guide comprenddes directives d utilisation pour diff rents produitst l command s Tous ces produits fonctionnentselonlesm meprincipesetutilisent les m mes types de codes Veuillez lire toutes les instructions et noter les informations se rapportant sp cifiquement votre produit Ce manuel s applique aux produits suivants Transmetteurs R cepteurs T l commande Interrupteur r cepteur D tecteur de mouvements mural sans fil int rieur Prise r ceptrice murale D tecteur de mouvements sans fil ext rieur Interrupteur d appoint T l commande pour enfant Interrupteur mural trois voies CARACT RISTIQUES Les produits sont test s et approuv s par UL cUL et FCC IC La port e op rationnelle est de 30 m tres Les commandes d clairage Heath Zenith sont con ues pour fonctionner ensemble Il suffit de d terminer queltransmetteur doit commander quel r cepteur puis de r gler les codes correspondants R GLAGE DES
74. s ensemble voir l illustration 8 Assurez vous quelesfils sontsolidement branch s et qu aucune partie d nud e n est expos e Fil de mise la terre d nud ou vert Bo te de connexion Interrupteur ON OFF R cepteur Vis de fixation Vis de plaque murale f Plaque murale Installation de l interrupteur transmetteur mural 9 Faites passer l antenne entre le bas de la bo te de connexion et le mur Ins rez l antenne dans la cavit murale en repla ant le transmetteur dans la bo te de connexion 10 Ins rezl interrupteurtransmetteur mural dans la bo te de connexion en vous assurant que le bouton du rh ostat DIM est situ droite Servez vous des deux grandes vis fournies pourfixerletransmetteur la bo te de connexion voir l illustration Repoussez es fils dans la bo te pendant l op ration Vous pourriez avoir les replier pour les ins rer dans la bo te Installez la plaque murale sur le transmetteur au moyen des petites vis fournies 11 R tablissez le courant au niveau du panneau de disjoncteurs ou de la bo te fusibles Fonctionnement 1 Assurez vous que l interrupteur d alimentation est en position ON plac du c t droit 2 Appuyez surle bouton ON partie du haut puis rel chez le L clai rage devraits allumer pleineintensit Note Pour commanderle fonctionnement d une lampe assurez vous qu elle est branch e la bonne prise de courant et qu elle est a
75. s m mes r glages de code que la t l commande OFF D sactive tout r cepteur dot des m mes r glages de code que la t l commande DIM Active la fonction RH OSTAT de tout r cepteur dot des m mes r glages de code que la t l commande Note En appuyant sur le bouton DIM vous avez acc s cinq degr s distincts de luminosit 598 1135 10 31 Note Pour commander ind pendamment un second r cepteur au moyen d une seule t l commande s assurer que le second groupe de commutateurs c t droit et que les commutateurs de chaque r cepteur sont r gl s aux m me positions consultez la section R glages des codes C t gauche Identique aux commutateurs du c t gauche C t droit Identique aux commutateurs du c t droit C t gauche DIM C t gauche ON d LL FA Cot droit OFF C t gauche OFF wa ED C t droit DIM y S C t droit ON i t Commandes des fonctions IMPORTANT Attendez 1 ou 2 secondes apr s avoir appuy sur un bouton du transmetteur avant d appuyer de nouveau dessus pour permettre la transmission de s effectuer Note Si le voyant ne s allume pas ou s il s allume par intermittence lorsque vous appuyez sur un bouton du transmetteur consultez le Guide de d pannage Pince de pare soleil d automobile facultative comprise La t l commande comprend une pince de pare soleil d automobile facultative pouvant
76. surface de montage Au moyen des deux trous l arri re du compartiment des piles marquer l emplacement des orifices au moyen d un crayon ou d un pointeau Au moyen d un foret de 2 5 mm 0 1 po percer deux trous pour les vis de fixation Si les vis ne sont pas fix es directement dans le bois ou dans un montant mural percer deux trous de 5 mm 0 2 po et utiliser les ancrages muraux fournis Fixer le d tecteur de mouvements int rieur un objet solide p ex mur plafond poteau etc au moyen des deux vis fournies Assurez vous que le d tecteur n a pas la vue obstru e IMPORTANT Serrer la main seulement ne pas trop serrer lt Dessus de D tecteur de comptoir mouvement Vis de montage ESS Installation du d tecteur de mouvements int rieur directe ment au mur Suite SIVONVHS Installation du d tecteur de mouvements ext rieur 1 Installez le support de montage du d tecteur l o vous d sirez d tecter le mouvement Fixez le support de montage a un objet robuste p ex un arbre un poteau une maison etc al aide des deux vis fournies Assurez vous que le d tecteur n a pas la vue obstru e Note Fixezle support de montage la verticale lorsqu il s agit d une surface incurv e par exemple d un poteau Installez le d tecteur de mouvement au support de montage l aide d un tournevis pointe cruciforme desserrez la vis de serrage sur le support de montage Ins rez la monture
77. tador de alimentaci n del transmisor evita que la unidad env e cualquier se al al receptor El desconectador de alimentaci n en el receptor evita que este imparta energ a a la carga que controla INFORMACI N DEL RECEPTOR Todos los receptores tienen las siguientes caracter sticas y potencias nominales Clasificado para un voltaje de alimentaci n de 120 V CA 60Hz Usa el cableado existente Se adapta a una caja de empalme simple est ndar Alcance t pico de transmisi n hasta 100 pies 30m Cuando lo prenda por primera vez espere 15 segundos RECEPTOR DE PARED CON INTERRUPTOR Caracter sticas y potencia nominal Hasta una carga incandescente m xima de 500 vatios dependiendo del interruptor comprado Vea en la placa de valores nominales del interruptor la potencia nominal exacta de la carga No se usa con tubos fluorescentes compactos A ADVERTENCIA PARA USO SOLO con bombillas incan descentes o hal genas de 120 voltios A CUIDADO Para reducir el riesgo de sobrecalentamiento y posible dafo a otros equipos no lo instale para controlar un receptaculo un artefacto motorizado un conjunto de luz fluorescente o un artefacto que usa un transformador Informaci n importante sobre instalaci n de conmutadores tridireccional Con el fin de usar este producto donde se est usando dos conmutadores para controlar un punto de luz se tendr tambi n que instalar un transmisor de pared con conmutador
78. tiquement a 50 ATTENTION Pour r duire les risques de surchauffe et de IMPORTANT Attendez 1 ou 2 secondes apr s avoir appuy sur dommage l quipement n installez pas cet appareil pour un bouton du transmetteur avant d appuyer de nouveau dessus contr ler un bo tier de commande un appareil avec moteur pour permettre la transmission de s effectuer lectrique un luminaire fluorescent ou un dispositif dot Note Si le voyant ne s allume pas ou s il s allume par intermittence d un transformateur lorsque vous appuyez sur un bouton du transmetteur consultez le Guide de d pannage Infomations Importantes Concernant L installation De L In Remplacement de l ampoule terrupteur Trois Voies Afin d utiliser ce produit l o deux Placez le sectionneur sur l metteur et sur le r cepteur la position interrupteurs sont utilis s pour contr ler l clairage l metteur OFF c t gauche Remplacez le s ampoule s Note Le sec de l interrupteur mural trois voies doit galement tre install tionneur sur l metteur emp che l unit d envoyer des signaux au R f rez vous ala section sur l installation de l interrupteur mural r cepteur Le sectionneur sur le r cepteur l emp che d appliquer trois voies pour de plus amples d tails de l leciricit la charge qu il contr le IMPORTANT Lors de l installation de multiples interrupteurs il faut en r duire graduellement la puissance com
79. to maintain water tightness Mounting Bracket Mounting Bracket Socket Mounting Screw PLA 2 Nut Clamp A Screw Swivel Ball Mount Sensor Installing Motion Sensor Check Operation and Adjustment Note When first turned on or when switching modes wait 30 seconds Locate the RANGE control and ON TIME control on the motion sensor Indoor Motion Sensor The RANGE control and ON TIME control are located inside the battery compartment on the front of the sensor To set the RANGE or ON TIME control remove battery compartment cover by sliding the cover down Outdoor Motion Sensor The RANGE control and ON TIME control are located on the bottom of the sensor Using your fingernails or a small flat head screwdriver gently pry the cover until it opens 1 Check Operation Set the ON TIME control to TEST mode Walk in frontof sensor unit The LED indicator light should flash when motion is detected see illustration page 6 for location of LED light 2 Adjust Sensor Turn the RANGE control to the mid position and ON TIME control to the TEST position Walk through coverage area noting where youare when the LED begins toflash Loosenthe clamp screw and move the sensor to change the coverage area Tighten clamp screw when finished Do not overtighten clamp screw Continued m zZ O o 72 I Adjust RANGE Control To increase sensitivity turn the RANGE control toward MAX To decrease sensitivit
80. tridireccional Para mayor detalle vea la secci n instalaci n del transmisor de pared con conmutador tridireccional IMPORTANTE Cuando estas unidades funcionen en grupo debe reducirse la potencia como sigue 300 Vatios 300 Vatios 300 Vatios 300 Vatios 450 Vatios 400 Vatios 500 Vatios 500 Vatios 24 598 1135 10 3 INSTALACION Seleccione el interruptor de la lampara que sera reemplazado por el receptor de pared con interruptor ADVERTENCIA Apague la energia al circuito del interruptor de la lampara antes de proceder Haga esto en su disyuntor o en la caja de fusibles Retire la placa y el interruptor de pared existentes Desconecte los dos conductores de energ a y el conductor de conexi n a tierra Nota Si hay m s de dos conductores de energ a conectados al interruptor consulte con un electricista sobre esta instalaci n Adem s algunos c digos locales sobre edificios pueden exigir que la instalaci n la realice un electricista calificado CUIDADO No conecte el neutro alambre blanco al interruptor 4 5 Si es necesario pelar 1 2 de pulgada de aislamiento desde el extremo de los cables Conecte uno de los conductores negros de energ a del receptor a uno de los conductores de energ a que retir del interruptor viejo Use uno de los conectores de alambre provistos para asegurar los conductores vea la ilustraci n Conecte el segundo conductor negro de energ a del receptor al otro
81. tton 5 Continue to press the DIM button until the desired dim level is reached Note There are 5 DIM settings ranging from 15 to 90 brightness Note The DIM setting defaults to 50 in the event of a power failure IMPORTANT Wait 1 to 2 seconds after you press a transmitter button before you press it again to allow the transmission to be completed Note If light does not turn on or intermittently turns on and off when transmitter buttons are pushed see Troubleshooting Guide Bulb Replacement Move the power disconnectswitch on the transmitter and receivertothe OFF left side position Replace bulb s Note The power disconnect switch on the transmitter prevents the unit from sending any signals tothe receiver The power disconnect switch on the receiver prevents it from applying power to the load that it controls m Z O E 72 ae RECEIVER INFORMATION All receivers have the following features and ratings Rated for 120VAC 60Hz supply voltage Uses existing wiring Fits standard single gang junction box Up to 100 feet 30 m typical transmission range When first turned on wait 15 seconds WALL SWITCH RECEIVER Features and Ratings Upto 500 Watt maximum incandescent load depend ing upon switch purchased See rating label on switch for exact load rating Not for use with Compact Fluorescent bulbs A maruno FOR USE ONLY with 120 volt incandescent or halogen bulbs A CAUTION To reduce the
82. upside down 2 Remove screw in access door of remote with a small phillips head screwdriver 3 Remove access door and lay aside 4 Remove battery Install replacement battery Make sure battery is oriented properly see illustration 5 Reassemble access door in reverse order Battery fo Compartment Type A23 LE jt Inside of Remote Control 3 WAY WALL SWITCH TRANSMITTER Important This product must be used in conjunction with the Wall Switch Receiver 3 way circuit wiring is required to install and use this product Note If you are not familiar with electrical wiring consult an electrician about installation In addition some local building codes may require installation by a qualified electrician Installation 1 Select light switch to be replaced by 3 way wall switch transmit ter 2 A WARNING Turn off the power to the light switch circuit before you proceed Do this at your circuit breaker or fuse box 3 Remove the existing wall plate and switch Label the wires on the existing switch according to the diagram in Figure 1 Note Typical 3 way wiring is shown Actual wiring and wire colors may vary Common Terminal Dark Screw Sto or LIGNT 059 Sel 3 Way tonor Switch OR LIGHT BLACK me 3 Way Switch Travel Travel Wire ve GREEN Ground Figure 1 Typical 3 Way Wiring 4 Disconnect the two travel wires wire connected to com
83. ur commander le Servez vous des fils en place fonctionnement d une lampe assurez vous qu elle est branch e Convient une bo te de connexion standard la bonne prise de courant et qu elle est allum e Port e de r ception maximum de 30 m tres 100 pieds 3 Appuyez sur le bouton OFF partie du bas puis rel chez le e Lorsque l appareil est mis en circuit attendre 15 secondes L clairage devrait s teindre 4 Appuyez sur le bouton gradateur puis relachez L clairage z devrait s allumer 50 de l intensit maximum ou en fonction INTERRUPTEUR RECEPTEUR MURAL du dernier r glage utilis Note Le r cepteur se souvient du dernier r glage du bouton gradateur utilis Pour rappeler le dernier r glage du bouton gradateur appuyez sur le bouton gradateur puis relachez 5 Continuez d appuyer sur le bouton gradateur jusqu ce que le niveau d intensit d sir soit atteint Note Le bouton DIM comprend cing degr s de r glage de l intensit qui varie de Fonctions et caract ristiques Puissance maximum d clairage incandescent de 500 W compte tenu du type d interrupteur achet Consultez l tiquette appos e sur l interrupteur pour connaitre la charge exacte Non con u pour les ampoules fluorescentes compactes 15 90 A AVERTISSEMENT UTILISER SEULEMENT avec des am Note En cas de panne de courant le r glage de l intensit revient Poules 120 V de type incandescent ou halog ne automa
84. ved from the old switch Use one of the supplied wire connectors to secure the wires see illustration Connect the green ground wire from receiver to the ground wire removed from old switch Use one of the supplied wire connectors to secure the wires see illustration Check wire connections to make sure they are secure and that no bare wires are exposed Route antenna between the bottom of the junction box and the wall Feed antenna into wall cavity while placing wall switch into junction box Position the wall switch receiver in the junction box with the DIM button located to the right Use the two wall switch screws long supplied to mount the receiver to the wall box see illustration Push excess wiring into wall box while you do this You may need to bend the wires to fit inside the box Mount wall plate on wall switch receiver with screws short provided 11 Turn on the power to the light switch circuit Do this at your circuit breaker or fuse box 10 Ground Wire Bare or Green Junction Box Wall ON OFF Button Switch Wall Switch Screw lf White Wall Plate a Neutral Screw r x Z Vial DIM Button Wall Plate Antenna Power Disconnect Switch Installing Wall Switch Receiver 598 1135 10 Operation 1 Verify the power disconnect switch is in the ON right side position 2 Push the ON top button and release The light should turn on full bright Note If you are controlling a lamp make su
85. y turn the RANGE control toward MIN Note If the RANGE is set too high false triggering may result in some environments Note When using test mode to check operation in the day time A Set the DETECT control switch to DAY NIGHT and B Set the ON TIME control to TEST Set ON TIME Control Determine the amount of time you want the connected device to stay on after motion is detected 1 or 5 minutes Slide the ON TIME control to the corresponding setting IMPORTANT Avoid Aiming Control At Objects that change temperature rapidly such as heating vents fans and air conditioners These air sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Outdoor Motion Sensor ON TIME Control d b Indicator EE Pl Range Control Indoor Motion Sensor Motion Sensor Controls 150 30 ft 9 1 m Maximum Range Maximum Coverage Angle Indoor Motion Sensor Coverage Area a 70 ft 21 m Maximum Range Maximum Coverage Angle Outdoor Motion Sensor Coverage Area Sensor Sensor Least Sensitive Most Sensitive The detector is most sensitive to motion across its field of view Indoor and Outdoor Motion Sensor Sensitivity 00
Download Pdf Manuals
Related Search
Related Contents
Kenwood - R-5000 User Manual Multiport User Manual - Honeywell Process Solutions Digitus DK-1641-PH-305 networking cable GE JES1133 User's Manual Manuale Utente - Oregon Scientific テレコンポーネントライブラリ (形式:TL2COM) 取扱説明書 - M Version intégrale NI-FBUS Offline Configurator User Manual AS-i/PROFIBUS-Gateways Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file