Home

Dale Tiffany TH12323 Installation Guide

image

Contents

1. Dale Tiffany ne ASSEMBLY INSTRUCTIONS Important Safety Instructions Power at the Fuse Box should be disconected before installing this fixture The Fixture ground wire bare or green installed wire is NOT connected to current carrying supply wires The insulation on any of the wires must not be damaged during installation No rough or sharp edges are in contact with any of the wires Fixture wires are connected to the proper house supply wires We recommend professional installation by a licensed electrician Do not use light bulb s with wattage greater than those APX WT 10 6 LBS specified for this fixture Power is off when installing light bulb s into the fixture Insure the outlet box is well mounted to the building structure and will be able to support the weight of the fixture The use of a crossbar is recommended O Read directions and follow steps 1 11 2 Carefully unpack and layout the parts as shown in illustration and read all instructions before starting 3 Follow numbered steps on diagram Screw Crossbar 3 to Ceiling Outlet Box with Ceiling Screws 4 attach Threaded Rod 5 to Crossbar 3 Screw Nut 6 and Loop 7 to Threaded Rod 5 4 Raise Canopy 8 and tighten Loop Collar 9 connect fixture chain 10 to the loop with desire length of chain 11 12 G 5 After connecting chain loosen Loop Collar 9 and lower 8 gt Canopy 8
2. OR SERVICING THIS FIXTURE Fixture 9 Screw the threaded rod into the socket assembly Adjust the knurl nut to leave enough room for the shade bi 10 Place the shade over the end of threaded rod pr E Fr and tighten with the finial securing the shade in place 5 SDE 11 Install 3 60W bulbs into the sockets Threaded Rod Shade FOR RETURN SHIPPING PURPOSES PLEASE RETAIN ORIGINAL PACKAGING TO MINIMIZE DAMAGE Uses 3 maximum 60Watt bulbs or 3 maximum 13Watt CFL bulbs Bulbs not included COMPONENT LIST Item Design Component Qty Ci I Chai A etter otal TP B Shade 1 pe Cc Threaded Rod 1pe D O Finial 1 pc SPARE PARTS Revision 12 18 12 LAYOUT ALL COMPONENTS AND REVIEW PARTS BEFORE ASSEMBLY Made in China Hecho en China Dale Thery Mnc INSTRUCCIONES DE ASAMBLEA Instrucciones de seguridad importantes Se debe desconectar la alimentaci n en la caja de fusibles O 4 antes de instalar esta lampara El conductor de tierra de la l mpara desnudo o verde instalado NO debe estar conectado a conductores de suministro SERIO E J que lleven corriente J Ninguno de los cables debe sufrir da o en el aislamiento durante la instalaci n T H 4 232 3 No debe haber bordos rugosos o filosos en contacto con alguno de los cables 4 Los cables de la l mpara se deben conectar a lo
3. a 9 Atornille la varilla roscada en la asamblea de bombilla Ajuste la tuerca moleteada de dejar espacio suficiente para la pantalla Asamblea Pron 10 Coloque la pantalla sobre el extremo de la varilla roscada de Bampa y apriete con el remate asegurar la pantalla en su lugar cai APRA 11 Instale 3 bombillas de 60W en los portal mparas Pantalla Usar 3 bombillas de 60 vatios m ximos o 3 m ximo bombillas CFL 13Watt Bombillas no incluidas Component Qty Dosel Cadena 1 pi L mpara Z calo pieza Pantalla varilla roscada 1 pieza Remate 1 pieza PIEZAS DE REPUESTO a Revision 12 18 12 DESEMPAQUETE TODOS LOS COMPONENTES Y REVISE PIEZAS ANTES DE LA ASAMBLEA Made in China Hecho en China
4. os conectores de cable 17 Vea por favor conexi n procedimientos abajo I Conecte el cable liso positivo de la l mpara con el cable de suministro negro con conector de empalme pl stico 17 Rosque el conector en direcci n de las manecillas del reloj hasta que sienta firmeza Il Conecte el cable estriado negativo de la l mpara con 47 el cable de suministro blanco de la caja de distribuci n Conector de cables de la misma forma 111 Tratar de jalar un poco las conexi nes de los cables para asegurar que estan bien colocadas Si se salen los cables al jalar el conector se devera cuidadosamente volver a conectar y apretar el conector firme a los cables IV Envolver por separado las conexi nes de los cables utilizando cinta adhesiva para conductos el ctricos Envolviendo hasta una pulgada de largo los cables incluyendo el conectores V Si la caja el ctrica provee de cable de tierra color verde o color cobre conectrar el cable de tierra de la caja el ctricia y el cable de tierra de la l mpara al tornillo verde de la abrazadera de montage juntando todos los cables y conectores 7 Asegure la base atornillando el enganche del anillo al anillo 8 Seguir el diagrama del lado de atras para seguir las instrucciones del ensamblado de la l mpara A gt TH12323 ADVERTENCIAS PARA EVITAR EL RIESGO DE DESCARGA EL CTRICA ASEG RESE DE APAGAR DURANTE LA INSTALACI N O SERVICIO DE ESTE APARATO L mpar
5. over chain 6 Thread Fixture Wires 13 through Chain pass Loop Collar Canopy Loop and Threaded Rod Connect Supply Wire with Fixture Wire using Wire Nut Connectors 17 Please see connection procedures below I Connect the positive smooth wire of the fixture with Black supply wire with wire nut connector 17 Screw the connector clockwise until you feel a firmness gt 3 A II Connect the negative ribbed wire from the fixture to the 12 AU white supply wire from the outlet box in the same manner Y Uh as 111 Try gently to pull the connector off the wires If you can pull J HASTY the connector off carefully re do the step above and check again 7 My for a firm connection IV Separately wrap the wires connections using electrical tape one inch below and include the connector V If your outlet box is provided with a grounding wire green or bare copper only attach this wire and the bare copper wire from the fixture to the green ground screw by wrapping both wires under the head of the screw and tightening screw If outlet box is not provided with grounding wire attach only the bare copper wire from the fixture to the green grounding screw Tuck all wires into Ceiling Outlet Box 7 Secure Canopy by screwing Loop Collar onto Loop 8 Follow Diagram on back side for fixture assembly instructions Po V Canopy TH12323 WARNING TO AVOID RISK OF ELECTRICAL SHOCK BE SURE TO SHUT OFF POWER WHILE INSTALLING
6. s cables aproximada 10 6 libras de suministro correctos de la casa Recomendamos instalaci n profesional por un electricista licenciado 3 5 6 2 Desempaquete y presente cuidadosamente las piezas No utilice bombillas de un vataje mayor al especificado de las bombillas para esta l mpara El suministro debe O Lea las instrucciones y siga los pasos 1 11 estar cortado durante la instalaci n en la l mpara Aseg rese de que la caja de salida est bien montada en la estructura de la construcci n y de que pueda sostener AO P fs 4 el peso de la l mpara El uso de una abrazadera de montage a las indicaciones de la ilustraci n es recomendado Seguir los pasos en el diagrama atornille la abrazadera 3 a la caja el ctrica con los tornillos 4 colocar la tuerca roscada 5 To a la abrazadera de montage 3 colocar la tuerca 6 y el enganche de anillo 7 a la tuerca roscada 5 Levantar la base 8 para apretar el enganche de anillo 9 conectar la cadena de la l mpara 10 al enganche de anillo colocando la cadena al tama o que se desea 11 12 Despues de conectar la cadena suelta al enganche de anillo 9 y bajar la base 8 sobre la cadena Colocar las cables de la l mpara 13 atraves de la cadena el enganche de anillo la base el otro enganche de anillo y la tuerca roscada Conectar las cables del suministra el ctrico a los cables de la lampara utilizando l

Download Pdf Manuals

image

Related Search

Related Contents

STM32-P407 development board USER'S MANUAL  para seleccionar  AN5122, Using Freescale`s LIN Driver with the MagniV Family  EXSYS 10/100/1000 PCI Ethernet Card  Muvit MUUSC0079 USB cable  Fujitsu LIFEBOOK E8310  SMART Brailler User Manual  神戸市下水道条例施行規則の一部を改正する規則をここに公布する    LOEWE Individual Sound Universal Speaker  

Copyright © All rights reserved.
Failed to retrieve file