Home
Lithonia Lighting AFST 2 32 MVOLT GEB10IS Instructions / Assembly
Contents
1. be replaced e fthe lamp is marked Hg it contains Mercury Follow all disposal laws See www lamprecycle org e These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s or owner s purposes this matter should be referred to Acuity Brands Lighting Inc WARNING RISK OF ELECTRIC SHOCK Disconnect or turn off power before installation or servicing Verify that supply voltage is correct by comparing it with the luminaire label information Make all electrical and grounded connections in accordance with the National Electrical Code NEC and any applicable local code requirements All wiring connections should be capped with UL approved recognized wire connectors CAUTION RISK OF INJURY Wear gloves and safety glasses at all times when removing luminaire from carton installing servicing or performing maintenance Avoid direct eye exposure to the light source while it is on WARNING RISK OF BURN Allow lamp fixture to cool before handling Do not touch hot lens lamp guard or enclosure Do not exceed maximum wattage marked on luminaire label Follow all lamp manufacturer s warnings recommendations and restrictions on lamp operation including but not limited
2. to ballast type burning position replacement and recycling Use only lamps that comply with ANSI standards CAUTION RISK OF FIRE Keep combustible and other materials that can burn away from lamp lens Do not operate in close proximity to persons combustible materials or substances affected by heat or drying Please see product specific installation instructions for additional warnings or any applicable FCC or Our Brands other regulatory statements For a complete listing of product Terms and Conditions please visit www acuitybrands com Indoor Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT SunOptics Carandini Mark Architectural Lighting Antique Street Lamps LC amp D Holophane Peerless Hydrel ROAM RELOC Renaissance Lighting Tersen Sensor Switch Light Concepts Winona Lighting Synergy Acuity Brands Lighting Inc assumes no responsibility for claims arising out of improper or careless installation or handling of its products 2010 Acuity Brands Lighting Inc All rights reserved 12 01 10 ABL General Warnings Form No 503 204 Lamp Replacement Fluorescent lamps typically have an average rated life of 20 000 hours Under normal operating conditions group relamping is recommended every 48 to 52 months Some lamp failure will occur before this recommended interval and single lamp replacement should be considered where necessary Lamps are r
3. READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION e To reduce the risk of death personal injury or property damage from fire electric shock falling parts cuts abrasions and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels e Before installing servicing or performing routine maintenance upon this equipment follow these general precautions e Installation and service of luminaires should be performed by a qualified licensed electrician e Maintenance of the luminaires should be performed by person s familiar with the luminaires construction and operation and any hazards involved Regular fixture maintenance programs are recommended e It will occasionally be necessary to clean the outside of the refractor lens Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user Refractor lens should be washed in a solution of warm water and any mild non abrasive household detergent rinsed with clean water and wiped dry Should optical assembly become dirty on the inside wipe refractor lens and clean in above manner replacing damaged gaskets as necessary e DO NOT INSTALL DAMAGED PRODUCT This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm Any part damaged or broken during or after assembly should
4. emoved by turn Use care when removing or installing lamps and do not work above others Ballast Replacement Before replacing ballasts first try replacing the lamps If that fails to solve the problem then the appropriate ballast should be replaced Before attempting to verify and replace a ballast the affected luminarie module must be taken off line To isolate power from the unit disconnect all circuits Most fluorescent luminaires ship with factory installed disconnects at each ballast location Although the ballast disconnect provides an additional safeguard when servicing fluorescent lamp luminaires it does NOT replace the need for turning off power to the circuit Once the ballast is replaced ensure all fasteners are reattached and all applicable plugs are solidly reconnected especially the grounding wire Note A ballast replacement should only be performed by a qualified technician Ballast warranties are offered by the ballast manufacturer and not by Lithonia Contact Lithonia for a ballast breakout by project if required or for ballast manufacturer service information Ballast information can also be found on the ballast label Inspection lt is recommended that lenses and lamp holders should be periodically inspected for cracks or damage from exposure to corrosive airborne chemicals and or to impact damage Any damaged component should be replaced Cleaning Instructions Regular cleaning of light fixtures is es
5. oft cloth dampened with a solution of warm water and a mild liquid detergent along the length of the fixture 2 Rinse using a different clean cloth dampened only with water 3 To avoid streaking run a dry cloth along the length of the fixture
6. sential for optimal lighting performance Exterior Surfaces It is recommended that all surfaces be cleaned regularly to remove accumulated dust and dirt Best results are obtained by wiping with a damp cotton cloth Internal Reflector Systems All luminaire reflectors should be dusted periodically to ensure optimal lighting performance possibly during a systematic relamping operation Any cleaning of reflectors should be carried out with care so as not to damage the materials used to optimize performance The specular aluminum reflector may be cleaned after lamps are removed and normal safety precautions are taken to avoid shock and electrocution including turning off power to the light fixture The reflector can be cleaned with a mild fast drying non alkaline solution and soft cotton cloth Examples of acceptable cleaners include a 2 solution of liquid dish soap to water or a 70 solution of ethyl or isopropyl alcohol to water Abrasive cleaners and materials as well as paper towels or any other wood based fabric products should be avoided The cleaning solution should be sprayed on to the surface of the specular reflector and then quickly wiped off longitudinally in the same direction that the lamps would run with a clean damp cotton cloth Once thoroughly cleaned the reflector surface should be lightly wiped off longitudinally with a dry cotton cloth Lens Panels To remove finger marks and typical dirt accumulation 1 Runa s
Download Pdf Manuals
Related Search
Related Contents
Pop`pomme surprise IMS mode d`emploi en français Guida per l`utente Trekstor i.Beat cody 4 GB black FICHE PRODUIT EPSON EB-410W Projecteur Multimédia Product Manual Samsung RT2534SACBX User Manual(INDIA) JVC KW-R900BT User's Manual Vez do leitor - Departamento de Sistemas e Computação Copyright © All rights reserved.