Worldwide Lighting W23143C40 Instructions / Assembly
Contents
1. Please read all instructions carefuly Before you proceed to install make sure that the power supply is turned off and off until installation is complete Please note that each part has been asigned a letter Please proceed in an alphabetical order A Existing Electrical Box B Crossbar C Crossbar Screws D Metal Plate E Crossbar Bracket F Neutral Conductor G Hot Wire H Junction Caps I Ground Wire J Wire Attach the Crossbar B to the existing electrical box A using the two crossbar screws E which are not supplied and should already be in your box CANOPY INSTALLATION DIAGRAM Frame Parts List WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main electrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to grou
2. W 23143C40 D40 X5 H7 L4 We are dedicated to providing the finest quality crystal chandelier for our customers Our master craftsmen and designer pride themselves on their attention to detail prompt efficient service is our priority Enclosed are detailed instructions on how to properly install your chandelier Please read all instructions carefully and thoroughly If you have any questions please feel free to call our toll free CHANDELIER HOTLINE AT 1 855 411 8999 C UL WARNING CONTENTS ARE FRAGILE HANDLE WITH CARE The metal frame and crystal components of this chandelier are very delicate Please excersise extreme Caution during unpacking and installation WARNING After passing the main electrical wire through the 10mm pipe and connecting the pipe to the main body top connector place all remaining pieces as shown in nurmerical order and in the orientation depicted Refer to the parts list to avoid confusion between parts The part Numbers coincide CAUTION 1 Rated 110v 130v 60Hz bulb E12 40W maximum 2 Care Should be taken to avoid damage to the surface of lighting and wire wearing gloves is recommended when installing 3 Connect black or red wire of the lighting to live wire and white or blue wire to neutral wire and double colored or bare copper wire to ground wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and othe
3. in wire is enough long and keep the rest wire in the 4 J box As the crystal pressing instruction hang the crystal parts Install lighting Source The end
4. nd wire 4 Never install lighting on damp ceiling the room should be dry and well ventilated 5 Keep lighting away from acid alkali and other corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing Claning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the electrical supply to the chandelier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting shall not be responsible for unprofessional wiring Frame Assembly Instructions Installation Please read all instructions carefully Before you proceed to install make sure that the power supply is turned off and remains off until installation is complete please note that each part has been assigned a number please proceed in a numerical order Fix the Crossbar 01 with junction box Make sure the positive and negative charges of wire and Lamp Body 02 match correctly screw the connect point with the junction cap Make sure the ma
5. r corrosive chemical or gas clean the lighting with Clean soft cloth only 6 Installation must be carried out by qualified electrician only 7 Disconnect the power before installing Claning and replacing lighting 8 Never cover the lighting when power is connected 9 Firmness must be secured when installing ceiling tube chain pipe and other connecting parts 10 Care should be taken to avoid damage when installing glass parts 11 All electrical components must be installed by a licensed electrician and in accordance with the National Electrical Code and the appropriate local electrical codes Make sure that the electrical supply to the chandelier is turned off at the main fuse or circuit breaker before doing any installation Worldwide lighting shall not be responsible for unprofessional wiring Crystal Dressing Diagram When dressing the chandelier with the crystals please remember to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals Crystal Dressing Instructions When dressing the chandelier with the crystals please remember to wear either rubber or cotton gloves So as to prevent any damage or smudging on the crystals 1 4mmX7 Quantity CANOPY PARTS LIST Existing Electrical Box Crossbar Screws Crossbar Screws x 2 not supplied Wire Connector Shrinkable tube Cable tie Ground Wire Frame Assembly Diagram CANOPY INSTALLATION INSTRUCTIONS