1. SeaGulllighting FOR YOUR SAFETY WARNING BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF EITHER THE FUSE REMOVED OR THE CIRCUIT BREAKER SET AT OFF GENERAL You don t need special tools to install this fixture Be sure to follow the steps in the order given Under no circumstances should a fixture be hung on house electrical wires nor should a swag type fixture be installed on a ceiling which contains a radiant type heating system Read instructions carefully If you are unclear as to how to proceed consult a qualified electrician ROOF FINIAL J OUTLET BOX pe A TOP WIRE ASSEMBLY I CONNECTOR ROOF SCREWS L NUT 7 NIPPLE F BACKPLATE K CAP NUT M eae NOT SUPPLIED FIGURE 1 IF SUPPLY WIRES ARE LOCATED WITHIN 3 OF BALLAST USE WIRE RATED FOR AT LEAST 90 C Installation And Safety Instructions HC 328 012405 Line art shown may not exactly match the fixture enclosed However the installation instructions do apply to this fixture Fill in Item Number on Carton and File This Sheet For Future Reference ITEM ___ ASSEMBLY Carefully remove the fixture from the carton and check that all parts are included as shown in figure 1 and 2 Be careful not to misplace any of the screws or parts which are needed to install this fixture STEP 1 If applicable Install top assembly I to roof H Secure with roof finial J CAUTION Fixtures with photo cells shou
2. et box Push the backplate K firmly over the mounting nipple F and against the wall Secure in place with cap nut M STEP 2 Install diffuser panels texture side in if applicable into cage A NOTE If applicable There is a variation in all castings in some cases the glass panels may be slightly loose when installed you may want to tape it in place Two 2 sided tape has been supplied for this purpose remove protective paper from each side of tape place on upper end of glass install and press against casting STEP 3 Install lamps STEP 4 Place roof H onto cage A and secure in place with roof screws L CLEANING To clean wipe fixture body with a soft cloth Clean glass with a mild soap Do not use abrasive materials such as scouring pads or powders steel wool or abrasive paper ORDERING PARTS Keep this sheet for future reference and in case you need to order replacement parts All parts for this fixture can be ordered from place of purchase Be sure to use exact wording from illustration when ordering parts WET LOCATION NOTE FOR FIXTURES LABELED FOR WET LOCATION AND USED OUTDOORS CAUTION To reduce the risk of electrical shock provide a watertight seal between the fixture and the mounting surface by using a silicone or similar caulking
3. ld be mounted at least 48 from all sides to avoid reflection of light back onto Photo cell causing the Photo cell to malfunction or flicker GROUNDING AND MOUNTING BAR LOCK UP OUTLET BOX NIPPLE F mA OUTLET BOX SCREWS MOUNTING BAR D WIRE CONNECTORS FIGURE 2 GROUND WIRE NOT INCLUDED INSTALLATION HC 328 IMPORTANT DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET Secure mounting bar D to outlet box with outlet box screws not supplied Thread nut E on nipple F so that 3 threads are exposed above nut E Thread nipple F into mounting bar D and secure with nut E A Take note of the color of the wire s on your fixture Identify which group your fixture wire s falls into and connect the wires according to the directions below a O gt lt f GROUP A CONNECT TO BLACK GROUP B CONNECT TO WHITE HOUSE WIRE HOUSE WIRE BLACK WHITE J PARALLEL WIRE ROUND amp SMOOTH PARALLEL WIRE SQUARE amp RIDGED WHITE OR GREY WITHOUT TRACER WHITE OR GREY WITH TRACER Tm SSN NYS BROWN GOLD OR BLACK WITHOUT TRACER J i BROWN GOLD OR BLACK WITH TRACER a C NU wO NG NI N Note When parallel wire is used the tracer wire is square shaped or ridged and less tracer wire is round in shape or smooth Seen best when viewed from wire end To separate wires grasp the ends of each wire and pull apart B Take your fixture wire s from group A and place evenly against the black
4. wire from the outlet box DO NOT twist wires together before using wire connectors C Fit a wire connector not supplied over the wires and screw the connector clockwise until you feel a firmness D Try gently to pull the connector off the wires If you can pull the connector off carefully re do steps B and C as above and check again for a firm connection E Connect the fixture wire from group B to the white wire from the outlet box in the same manner GROUNDING INSTRUCTIONS The green grounding screw G is to be inserted into the hole with two raised dimples provided on the mounting bar D Wrap the ground wire from the fixture if supplied and the ground wire from the outlet box bare metal or green insulated wire around the green grounding screw G on the mounting bar D if uninsulated wire is on the mounting bar D connect the ground wire from the fixture if supplied and the outlet box to it using a small wire connector not supplied NOTE Underwriters Laboratories U L does not require all fixtures to have ground wires These fixtures still meet all U L specifications The listing mark of Underwriters on the product identifies products manufactured under its listing and Follow Up Service Programs NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES FINAL ASSEMBLY Make sure no bare wires can be seen outside wire connectors STEP 1 After the wires are connected tuck them carefully inside the outl

Download Pdf Manuals

image

Related Search

Related Contents

Eglo EINBAUSPOT GU10  xSDR - User's Guide - DB    Publication de l`AIC NR 6/13 du 28 AUG 2013 renfermant la  LanPhone 101 User manual  74514 Valve monitoring system user manual  biberon logo.pub      Biogas Laboratory Setup in Foz do Iguaçu, Brazil  

Copyright © All rights reserved.
Failed to retrieve file