Home
Doulton DOULTON-W9330958 Instructions / Assembly
Contents
1. Doulton Water Filters 14 September 2007 HIP Ultracarb Undercounter Water Filter Part No W9330958 Installation and Conditioning Instructions Replacement Elements Ultracarb Cartridge Part No W9123053 Rated Service Flow 1 9 litres min 0 5 gallons min Rated Capacity 2300 litres 600 gallons Maximum Working Pressure 100 psig 689kPa See 1 1 Maximum Working Temperature 30 C 86 F Minimum Operating Pressure 10 psig 69kPa Minimum Operating Temperature 5 C 41 F The HIP UC Undercounter Water Filter carton contains 1 HIP housing cap body and 0 seal 4 feet flexible tubing 1 Push fit equal T 1 Push fit adapter 1 Drinking water faucet and fitting kit 1 Bracket 3 Bracket screws 2 Mounting screws 1 Ultracarb Candle 1 Candle O ring 1 Installation 1 1 Pressure Information The unit has satisfied the NSF Std 53 structural test criteria However due to the potential wide variations of pressures from one installation to another the manufacturer advises that if there is any doubt that the system would see pressures above 100 psig approx 6 9bar then an approved pressure reducing valve bought from a good hardware store and set at 100 psig approx 6 9bar should be installed upstream of the filter to eliminate any extreme variations in pressure Water fittings for use in permanently pressurised systems may have a finite life It is important that the plastic components in the system a
2. ewed from the cap and cleaned in accordance with the manufacturer s instructions or replaced as described in Section 1 4 When the cartridge has been re installed wipe the filter housing clean with a damp cloth Cleaning Sterilising the Filter Housing If it is necessary to clean or sterilise the housing the following substances should be avoided a Strong oxidising agents such as bleach or Milton solution b All strongly acidic materials including some descalents c Strongly alkaline materials If a new cartridge is installed condition this cartridge for use in accordance with the cartridge manufacturer s instructions It is important to wash your hands thoroughly after servicing the filter necessary to install an approved 5 micron cartridge pre filter system bought from a good hardware store A cartridge that has reached the end of it s life would be indicated by a reduction in the quality of the filtered water with respect to taste The cartridge should be replaced in accordance with the rated service capacity which would typically give a period of six months usage Parts and Service Availability For sales service and replacement parts please contact your local Doulton distributor Only use genuine Doulton replacement elements to ensure optimum filter performance Manufactured by Fairey Industrial Ceramics Limited Newcastle Staffs STS 9BT England Telephone No 44 1782 664420 Website www faireyce
3. g the cartridge into the cap Hand tighten only Conditioning the Filter The system should now be ready for pressurisation With the user tap faucet in the on position gradually open the upstream isolation vale until the flow from the tap has stabilised at the recommended flow rate Then close the user tap faucet and ensure that there is no water leaking from the system joints When the system has been confirmed watertight open the user tap and allow the water to run to waste for a minimum of 10 minutes When water first comes out it is normal for some grey dust to be flushed from the filter Allow the filter to stand for 24 hours to condition the filter to the source water and then flush for a further 10 minutes to waste After carrying out this procedure the filter is now ready for use During use contaminants filtered from the water may build up on the outer surface of the ceramic cartridge and cause a reduction in flow through the unit The cartridge will therefore need cleaning to restore the flow Cleaning frequency will be dependent upon the condition of the incoming water 3 Servicing the Filter Cleaning removal and reinstallation replacement of the cartridge is carried out as follows With the upstream isolation valve off vent the pressure by opening the user tap Place a bowl under the filter body Unscrew the filter body which will be full of water and lower the body into the bowl The cartridge can now be unscr
4. ngth of the copper pipe v Deburr the edges of the copper pipe with a file and push the ends of the pipe 4 into the push fit T 7 It should go in at least vi Cut a suitable length of flexible tube push one end into the remaining connection on the push fit T and the other into the inlet connection on the filter cap 3 ensuring that the arrow on the cap is showing the correct direction of flow vii Drill a hole 1 2 diameter in the countertop in the desired location for the faticet 6 viii Slide the escutcheon plate and black rubber washer on to the threaded stem of the faucet Locate the threaded stem of the faucet through the drilled hole slide on the black locating washer the lock washer and lock into position with the back nut provided ix Screw the push fit adapter 5 onto the threaded end of the faucet under the counter top x Push one end of the flexible tube 4 into the outlet of the cap and the other end into the push fit adapter xi Place the cartridge washer 9 onto the threaded nipple on the cartridge 8 and screw the thread into the cap until washer resistance is felt N B Do not over tighten When the cartridge seal is made moisten the O ring on the filter body and replace it onto the location groove The body can now be screwed to the cap If there is less than 10 clearance below the base of the filter housing place the filter body in position over the cartridge before screwin
5. ramics com Doulton is a trademark used under license by Fairey Industrial Ceramics Ltd Sterasyl is a trademark registered to Fairey Industrial Ceramics Ltd Note Where high particulate dirty water leads to regular blockage of the ceramic cartridge it may be Leaflet No W2393031 Issue 1
6. re replaced after 10 years usage 1 2 Selecting a position for the Filter The filter should be fixed to a unit or wall with the screws and bracket provided near to the incoming water supply and the desired position for the faucet N B This filter is not designed for the treatment of hot water and should only be connected to the cold water supply Make sure that the filter is located so that the length of tube provided does not have any sharp bends in it For easy servicing of the filter there should be at least 4 inches of clearance below the body of the filter to allow for removal of the cartridge for cleaning or renewal Choose a position for the connection into the water supply which allows for cutting the pipe and flexing the ends into the push fit T Check that the supply pipe is 3 8 od copper if in doubt ask your plumber 1 3 Connecting Pipework and Fittings The filter is supplied with 3 8 push fit connections for ease of assembly Assembling and Fixing the Filter i Having chosen the position for the water filter see 1 2 above mark the position of the bracket fixing screws 10 on your wall unit ii Attach the bracket 12 to the filter cap 3 by using the 3 self tapping screws 11 provided iii Attach the bracket and lid to the wall unit with the bracket fixing screws iv Isolate the water supply at the stop valve and cut the copper pipe at the required position It may be necessary to cut out a le
Download Pdf Manuals
Related Search
Related Contents
Emerson 1808 Series Relief Valve or Backpressure Regulators Data Sheet sc-40x / sw-41x user manual USER`S MANUAL - Fujitsu General UK Hype -Manual X7 IT Kramer Electronics VM-4HN Histórico de versiones del Programa CALENER Power Battery Company, Inc. Field Service Manual Copyright © All rights reserved.