Home

none P8ACSL Instructions / Assembly

image

Contents

1. 13 IPS WASTE OPTIMUM LOCATION STUB OUT 1 25 3 13 OPTIONAL GLASSFILLER LOCATION WATER COOLER PVBACSL PVFBACSL PUSH PAD PUSH BUTTON WATER COOLER AND FOUNTAIN 4 178 448 a 324 e 162 2 PLCS 2 PLCS ELECTRONIC EYE MODELS ONLY 4418 HANGER MOUNTING HOLES 4 PLCS 144 57 941 1 2 1321 2 PLCS 554 73 196 897 27 2 PLCS 686 15 392 2 PLCS 24 211 6111 540 7 178 16 MOUNTING HOLES 2 PLCS 8 PLCS ELECTRICAL OUTLET OPTIMUM LOCATION 3 WATER SUPPLY OPTIMUM LOCATION STUB OUT 1 25 1 TRAP STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED ALLOW 4 INCHES 102 MM MIN PER SIDE FOR VENTILATION RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30 760 BY 48112201 ADJUST VERTICAL ENSIONS AS REQ D TO COMPLY WITH FEDERAL STATE AND LOCAL CODES ALL DIMENSIONS ARE INCHES DIMENSIONS IN BRACKETS 1 ARE IN MILLIMETERS FoR READ Stews 209 14 O D TAILPIECE ROUGHING IN AND DIMENSIONAL DRAWING OASIS II Models PR8ACSL PR8ACSLEE PRF8ACSL PRF8ACSLEE PRV8ACSL PRVF8ACSL NOTES OPTIONAL GLASSFILLER 1 TRAP STOP VALVE AND LOCATION ELECTRICAL OUTLET NOT FURNISHED WATER WATER ALLOW 4 INCHES 102 MM MIN FOUNTAIN COOLER PER
2. OASIS VERSACOOLER II MODELS P8ACSL P8ACSLEE PF8ACSL PFSACSLEE PV8ACSL PVF8ACSL PR8ACSL PRSACSLEE PRF8ACSL PRF8ACSLEE PRV8ACSL PRVF8ACSL INSTRUCTIONS A INSPECTION Inspect the water cooler water fountain and cartons for evidence of rough handling and concealed damage Damage claims should be filed with the carrier TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 1 NOTE The following states require a licensed plumber to install cooler AG GA MI OK RI SC SD TX VT and WI KS MN NM and OR allow for a state registered installer or contractor as well State and local plumbing codes may prohibit the use of saddle tapping valves for water line connection in some applications All connections must conform to applicable plumbing codes Locate and install plumbing and electrical service in accordance with the Roughing in Drawing FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING UNIT Install wall hangers as shown on Roughing in drawing Filter units have additional instructions on a label inside the access panel Read these before installing unit Wall hangers are shipped fastened to backs of the unit Mount water cooler on right side wall hangers as shown on Roughing in drawing Note FOUNTAIN SIDE left hanger and COOLER SIDE is on right hanger Straighten inlet WATER IN tube on water fountain Mount water fountain on left side wall hangers while inserting WATER IN tube into access hole of water co
3. SIDE FOR VENTILATION RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30 760 BY 48 1220 ADJUST VERTICAL PRVBACSL DIMENSIONS AS REQ D TO COMPLY 5 8 HANGER MOUNTING i PRVEBACSL WITH_FEDERAL STATE AND LOCAL HOLE 4 PLCS PUSH PAD PUSH BUTTON CODES WATER COOLER ALL DIMENSIONS IN INCHES AND FOUNTAIN DIMENSIONS IN BRACKETS 4 6 HANGER MOUNTING ARE IN MILLIMETERS HOLES 2 PLCS CONNECT COOLER REMOTE OUTLET T15 DRIVE SIZE TO FOUNTAIN INLET WITH EXTENSION 1 IPS WASTE OPTIMUM PROVIDED TORX HEAD SCREWS COON Our ELECTRONIC EYE MODELS ONLY PRVFSACSL FILTER WITH FLEXIBLE TUBING 13 2 PLCS AA 2 33 aE 2161 MOUNTING 838 24 1 73 57 144 359 9211 2 PLCS 2 PLCS abe ORIFICE HOLES 8 PLCS 29 744 ELECTRICAL OUTLET oe TAILPIECE OPTIMUM LOCATION 2 WATER INLET 51 WITH STRAINER 1 44 743 196 2 PLCS 15 302 i 2 PLCS WATER SUPPLY OPTIMUM 179 LOCATION STUB OUT 1 25 7 178 ROUGHING IN AND DIMENSIONAL DRAWING
4. e power supply against the water cooler data plate to assure correct electrical service Plug power supply cord into wall outlet The rear most 1 3 8 diameter knockout in the frame bottom is for an externally located electrical supply Make sure the knockout hole edge is smooth and free of any burrs Use of a Heyco busing 2184 in the knocked out hole recommended in order to prevent damage to the service cord and to close up excess opening around the cord Route the cord so it does not interfere with space 12 fill the cold water tank on the water cooler open the water supply line shut off and push any one of the front pushbuttons to allow water to flow to the bubbler On The EE model actuate the solenoid by holding one hand approximately 3 inches from the infrared sensor Run water until stream is free of bubbles 13 adjust bubbler stream a All pushbutton models are equipped with a cartridge regulator The P8ACSL and PF8ACSL have a slot the shelf below the pushbuttons Insert a screwdriver in this slot to adjust regulator Turn adjustment clockwise to increase stream height To access PV8ACSL and PFV8ACSL adjustment remove the beze and button from the front of the cooler b Electric eye EE models have a regulator built into the bubbler If adjustment is needed insert 5 64 wrench approximately 1 1 8 into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw Tum the adjust screw clockwise to
5. enance operation required is the removal of dirt and lint from the condenser of the water cooler Inspection should be made at 3 month intervals Disconnect the power supply cord then clean the condenser with a small stiff non wire brush when required Observance of this procedure will ensure adequate air circulation through the condenser so operation is efficient and economical D OVERLOAD PROTECTION water cooler compressor motor where used is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload E LUBRICATION water cooler This unit is equipped with a hermetically sealed compressor and requires no additional lubrication The fan motor on this unit seldom needs oiling but if required a few drops of SAE 10 oil should be used F TO DISCONTINUE USE OF WATER COOLER AND WATER FOUNTAIN 1 Close water shut off valve 2 Provide container catch water to be drained 3 Disconnect the water supply line at the water cooler WATER SUPPLY tube Disconnect water cooler DRAIN REMOTE COLD WATER tube from water fountain WATER IN tube Place container under water cooler DRAIN REMOTE COLD WATER tube then push and hold push button on the water cooler until water cooler is completely drained Place container under water fountain WATER IN tube then push and hold push button on the water fountain water fountain is completely drained 4 Disconnect the power supply cord
6. oler Connect water cooler DRAIN REMOTE COLD WATER tube to water fountain WATER IN tube provided waste drain parts for field instaBation are packed in the now refrigerated side of the unit Connect the tee provided to fountain tail piece Connect the elbow end of the 18 waste arm provided to the tail piece of the water cooler Connect the straight end of the waste arm to the tee Connect the 1 1 4 diameter tail piece extension provided to the bottom of the tee Install trap to the fountain tail piece Refer to the roughing in drawing for waste configuration When the unit has an internal waste trap the trap should be wrapped with insulating tape to prevent sweating Use of the 1 3 4 diameter knockout for a waste line is not recommended because of a potential conflict with toe space clearance requirements Check your local building code inspector for approval 9 Install a shut off valve in water supply line Remove the strainer from the cooler Water Supply tube Solder 3 8 inlet tube extension furnished with lead free solder to Water Supply tube and insert the strainer in open end of extension Connect extension to shut off valve To allow access to strainer for service this conection should not be a solder or flare joint To ease removal of the strainer a sheet metal screw may be lightly threaded into the open 10 Rotate fan blade by hand to see that it is free of obstructions 11 Check the availabl
7. reduce the stream height or counterclockwise to increase the height Note less than one tum is required to go from a closed to a wide open flow Do not overtighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result 14 adjust the beam range of the sensor models only a Shut off the water and power supplies b Remove the two screws from the top front c Remove the eight screws from the bottom of the nose that holds the nose to the shelf d Remove the nose to gain access to sensor adjusting screw located between the two lenses e The screw can be tumed a maximum of tums Tum screw counterclockwise to decrease range The sensor has an adjustable range of 24 to 48 It is factory set at 27 There is norradjustable on time delay of 75 seconds to prevent nuisance actuation of the solenoid valve should someone walk by After drinking the water will shut off immediately after walking away Maximum run time 30 seconds should someone tamper with the sensor NOTE Walls with a reflective finish i e ceramic tile across from the sensor may cause false actuation no matter what the sensor adjustment is for distance Therefore do not install the unit in such an area or dull the surface of the wall so it will not reflect light f The sensor may be remotely adjusted with a PDA Software may be downloaded from the Oasis web site Tech Tips section MAINTENANCE The only maint
8. s 5 Piug both water cooler DRAIN REMOTE COLD WATER tube and water fountain WATER tube 6 ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER With Disabilities Act WARNING The warranty and the Underwriters Laboratory listing for this machine are automatically voided if this machine is altered modified or combined with any other machine or device Alteration or modification of this machine may cause serious flooding and or hazardous electrical shock or EXCEPT AS SET FORTH HEREIN THE MANUFACTURER MAKES NO OTHER WARRANTY GUARANTEE OR AGREEMENT EXPRESSED IMPLIED OR STATUTORY INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE EN AT OASIS OASIS CORPORATION 265 N Hamilton RoadeP Box 13150 Columbus OH 43213 0150 1 800 64 OASIS 1 800 646 2747 www OasisWaterCoolers com oy oasis 2 and Versacooler are registered trademarks of OASIS Corporation 030099 268 2003 OASIS Corporation OASIS Versacooler II Models P8ACSL P8ACSLEE PF8ACSL PF8ACSLEE PV8ACSL PVF8ACSL NOTES WATER FOUNTAIN 2 0 D WATER INLET WITH STRAINER CONNECT COOLER REMOTE OUTLET TO FOUNTAIN WATER INLET WITH FITTING SUPPLIED 4 6 HANGER af MOUNTING HOLE 2 PLCS 84 PF8ACSL EE amp PVFBACSL N FILTER WITH TUBE EXTENSION 2 13 2 PLCS 33 oneal

Download Pdf Manuals

image

Related Search

Related Contents

Apex MJ-16 computer case  Hardware Manual V1.1  Le système Tentaculaire  プログラムタイマー TS-4P (PDF:1.19MB)  CERTIFICADO DE GARANTÍA  BRUKSANVISNING • KÄYTTÖOHJE • USER GUIDE MULTI  Defensor PH26 Bedienungsanleitung  Le marché de gros de Dillon mode d`emploi - Fort-de  Spitfire® RTU & SC  solo per servizio personale inverter multi  