1. Before entering a spa or pool the used should measure the water temperature at several locations using an accurate thermometer since the tolerance of water temperature regulating devices may vary as much as much as 5F 3 C Alcohol drugs or medication should not be used before or during spa or pool use since their use may lead to unconsciousness with the possibility of drowning 6 Persons suffering from obesiity or with a medical history of heat disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a Spa or pool 7 Persons using medication should consult a physician before using a spa or pool since some medication may induce drowsiness while other medication may affect heart rate blood pressure and circulation Prolonged immersion in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98 6 F The symptons include dizziness fainting drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include Unawareness of impending hazard failure to perceive heat failure to recognize the need to exit spa or pool physical inability to exit Spa or pool fetal damage in pregnant women and Unconsciousness resulting in a danger of drowning 8 SAVE THESE INSTRUCTIONS Recommended level s Water Temp Total
2. SsMarRnT GREEN ENERGY PRODUCTS ST GREEN ENERGY PRODUCTS ECO SPA amp POOL OWNERS MANUAL amp INSTALLATION GUIDE MODELS ECO SPA 5 5 11 ECO POOL 18 27 IMPORTANT SAFETY INSTRUCTIONS INSTALLATIONIN STRUCTIONS USER INSTRUCTIONS As when installing or using any high voltage electrical appliance basic safety precautions should always be followed Under no circumstances should you attempt to clean install inspect repair disassemble or other wise service this water heater without first shutting off all power to the unit directly at the breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN amp PLUMBER IN ACCORDANCE WITH Article 680 of the National Electrical Code NFPA 70 and with the requirements of the authority having jurisdiction and all applicable national state provincial and local electrical codes PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION amp USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY OR DEATH amp VOID YOUR WARRANTY IMPORTANTSAFETYINSTRUCTIONS READANDFOLLOWALLINSTRUCTIONSANDSAVETHESEINSTRUCTIONS ABOUT YOUR SPA POOL HEATER Congratulations on the purchase of your Spa Pool Heater You have purchased the most techno logically advanced Spa Pool heater in the market today Your ECOSMART Spa Pool Heater is backedbytheindustry smostcom
3. Alkalinity ppm Calcium Hardness ppm Free Chlorine ppm Total Dissolved Solids ppm Fiberglass Fiberglass Other Spa and Pool Spas Types Pools 89 104 F 68 88 F 68 104 F 31 40 C 20 31 C 20 40 C 7 3 7 4 7 3 7 4 7 6 7 8 120 150 120 150 80 120 150 200 200 300 200 400 6000 Max 6000 Max 6000 Max 3000 Max 3000 Max 3000 Max WATER TREATMENT For the protection of your spa and pool equip ment and health it is important that your water be chemically balanced CAUTION CorrosivewaterVOIDSall warranties Free Chlorine MUST NOT EXCEED 5 ppm Occasional chemical shock dosing of your spa and pool should not damage the heater as long as the water is balanced Automatic Chlorinators and Chemical Feed ers All chemicals must be completely diluted into spa or pool water befor ebeing circulated through the heater Chlorine tablets or bro mine sticks should not be placed in skimmer High chemical concentrations will result when the pump is not running Chlorinators must be feed downstream of the heater and have anti siphoning device to prevent chemical backup into the heater when the pump is shut off CAUTION High chemical concentrates from feeders and chlorinators that are out of ad justment will cause rapid corrosion to heater This type damage is not covered under the warranty For additional information or questions please call 877 474 6473 E mail info ecosmartus com Do not re
4. the model being installed A S an a ee ECO SPA5 5 ECO SPA 11 010 51 Ek f 510 0 EW f Quantity Amperage Type DOUBLE POLE DOUBLE POLE DOUBLE POLE DOUBLE POLE es ee ee ee ee eee eee BREAKERS A separate ground conductor for each incoming circuit is required DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connec tions are tight and secure Also confirm that the correct breaker size and wire gauge has been used and confirm that the unit has been connected to aground in accordance with applicable codes 5 HOWTOOPERATEYOURSPA POOLHEATER Once your Spa Pool heater has been installed and you are ready to begin enjoying it year round You MUST make sure your pump timer is disengaged to allow it to run until desired temperature Setting is reached Your heater will ONLY heat your Spa Pool when there is water running through it and ONLY when your Spa Pool pump is working if your Spa Pool pump is not running your Spa Pool heater will not turnon Your pool heater has a 3 minute build in TIME DELAY to protect it from air in the lines and elements burn out when the unit senses water flow it will automatically activate GREEN LED will turn on When you initially start to heat your pool you must run your pool pump without the timer In order to reach your initial desire pool temperature you will need to run the pool heater for the required time 6 DIGITALCONTROLTEMPERATURESETTIN
5. G TURN CONTROL KNOB TO SET YOUR DESIRED SPA POOL TEMPERATURE WHEN THE SET TEMPERA TURE IS REACHED THE HEATER WILL RUN IDLE AND CONSUME NO ENERGY Digital Control Temperature Setting All Ecosmart models come with a digital control temperature setting located in the front panel that can be easily set from 80 104 F 26 40 C in 1 degree intervals by a simple turn of the knob The heater can also be turned OFF by pushing the control knob once and converted to Celsius by holding the knob in for 3 seconds You just SET IT and FORGET IT 7 IMPORTANT SAFETY INFORMATION When using this electrical equipment basic safety precautions should always be followed including the following Pool water temperatures typically range from 78 F to 82 F The American Red Cross recommends a temperature of 78 F for competitive swimming However this may be too cool for young children and the elderly who may require a te mperature of 80 F or higher 1 READ AND FOLLOW ALL INSTRUCTIONS pe The water in a spa or pool should never exceed 104 F 40 C A water temperature in excess of 104 F is considered unsafe for all persons Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children Excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy Pregnant or possibly pregnant women should limit spa or pool water temperatures to 100 38 C
6. nnections All models are rated 240V single phase Units are Flow activated No Hartford loop is required INLET moo y OUTLET SMaAT Spa Installation Diagram 7 Check Valv i Pd UE pen Fs yo Spa eZ Filter oe _ Chlorinator Bypass a Customer Installed Drain Valve 1s Customer instafled F Gate Valve Shut Off Ball valve 7 Customer Installed From Spa Pool Installation Diagram A Spa Pool return SHUT OFF VALVE MUST BE INSTALLED AT INLET OF UNIT ELECTRICAL AND PLUMBING CONNECTIONS MUST BE FOLLOWED TO MEET ALL LOCAL CODES AND REQUIREMENTS After tightening both fittings at the water heater RUN our pump to allow water to run through the Spa Pool heater for at least 5 10 minutes This process purges all the air from the water lines and MUST be performed prior to turning on the power at the unit FAILURE TO FOLLOW THIS STEP CAN CAUSE PERMANENT DAMAGE TO THE HEATING ELEMENTS When any maintenance is performed on the Spa Pool that may introduce air into the plumbing pipes itis important to turn the power off to the Spa Pool heater and purge the air out of the lines before allowing the unit to power up DRY FIRINGofELEMENTS caused by water voids when power is on ALL air must be purged from system before any heat start up It is IMPORTANT to purge all air after cleaning or changing a car tridge filter The filter casing acts as an air reservoir during this procedure the circulation
7. prehensivewarranty To get the best performance and energy savings from your Spa Pool heater it is important that it be installed in accordance with our instructions and the electrical and plumbing codes applicable to your area and that you read this manual thoroughly for important operating instructions and tips At any time if you have any questions please contact your Authorized Dealer or contact us directly at ECOSMARTUS L L C 3315NW167THSTREET MIAMIGARDENS FLORIDA33056 TollFree 1 877 474 6473 CONTENTS Spa Pool heater Installation Location Water Connections Plumbing Diagram Electrical Connections ElectricalDiagram How to operate your Spa Pool heater Digital Control Temperature Setting Important Safety Information Warranty Information Warranty Registration Card MO o NOUA UNBE 1 BEFORE YOU INSTALL THIS PRODUCT PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY BEFORE INSTALLATION AND BEFORE USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE OR SERIOUS PERSONAL INJURY OR DEATH amp VOID YOUR WARRANTY By installing this product you acknowledge the terms of the manufacturer s warranty and your Authorized Dealer s return policies Spa Pool heaters that have been installed cannot be returned If you have any questions regarding the warranty or product return policies please consult your Author ized Dealer prior to installation Open the box and carefully unpack the Spa Pool heater Inspect all component
8. s 2 INSTALLATION LOCATION Ecosmart heaters are designed for either indoor or outdoor use Units must be mounted on a level base parallel to the ground Allow6 clearance at sides and at least 18 clearance at top and front for any maintenance or repairs Secure the unit to the base via screws not provided RecommendedClearances Top 18 inches CAUTION Combustible materials should be kept at least 24 inches Sides 6 inches away from your heater and the output hot water pipe 3 WATER CONNECTIONS PLUMBING DIAGRAM Please follow all plumbing instructions carefully This product must be installed by a licensed and qualified plumber inaccordance with all applicable national state pro vincial and local plumbing codes IMPORTANTNOTES WHEN PREPARING THE CONNECTIONS GOING TO UNIT MAKE SURE YOU DO NOT USE GLUE OR PUDDY ANY GLUE OR PUDDY GOING INTO UNIT WILL DAMAGE THE FLOW SENSOR PERMANENTLY PRIOR TO THE FINAL HOOK UP TO UNIT FLUSH ALL THE LINES TO CLEAR ANY DEBRIS IN LINE NOTE When using two speed pumps do not install gate valve on inlet No shut off valves are to be installed in the piping between the spa heater outlet and the spa If using an in line chlorinator a check valve must be used Any chlorinators valves that can cause return line block age will VOID the warranty SPA POOL HEATER MUST BE INSTALLED AFTER FILTER Spa models are supplied with 11 2 NPT and Pool models with2 NPT inlet and outlet plumbing co
9. st comply with the U S National Electrical Code NEC in the U S A or the Canadian Electrical Code CEC in Canada Failure to do so could result in property damage and or personal injury and void your warranty Note the Canadian Electrical Code generally requires that all supply wires and corresponding circuit protection breakers used for hot water heating and hydronic heating applications be sized to a minimum of 125 of the maximum Current rating of the heater see model specifications below for details Before installing this product ensure that the home has sufficient electrical power available to handle the maximum amperage load of the applicable model ALL UNITS HAVE A 3 MINUTE TIME DELAY ONSTART Electricalspecificationsbymodel MODELS ECO SPA 5 5 ECO SPA 11 ECO POOL 18 ECO 27 wawo o o o o EACH SUPPLY 5 5KW 55W 3xow REQUIRED RATING BREALER 30AMPS 60 AMPS 2 X 50AMPS 3 X 50AMPS RECOMMENDED HOUSE 100 AMPS 150 AMPS 150 AMPS 200 AMPS Wire connection to breaker Model Eco Spa 5 5 Wire connection to breaker Model Eco Spa 11 ECO SPA5 5 ECO SPA 11 L1 L1 Li Li KAES DOUBLE POLE BREAKER DOUBLE POLE BREAKER Wire connection to breaker Model Eco Pool 18 Wire connection to breaker Model Eco Pool 27 ECO POOL 18 ECO POOL 27 a fefe ble ufule T El eT Es El DOUBLE POLE BREAKER DOUBLE POLE BREAKER DOUBLE POLE BREAKER DOUBLE POLE BREAKER DOUBLE POLE BREAKER Wire amp Breakers specification based on
10. system must be on for at least 2 minutes before you turn power on Water Flow Your Spa Pool heater must have an adequate flow of water flow for proper operation Adequate water flow removes the heat produced by the heater and transfers the heat to the Spa Pool and prevents overheating Low water flow usually results from dirty filter or improperly ad justed manual by pass Manual by pass valves should be set so that the outlet temperature com ing from the heater is 6 8 degrees F above the Spa Pool water after five 5 minutes of heater op eration This can be measured using a thermometer 4 ELECTRICALCONNECTIONS ELECTRICALDIAGRAM PLEASE READ THE SE INSTRUCTIONS THOROUGHLY AND COMPLETELY BEFORE INSTALLATION AND BEFORE USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE OR SERIOUS PERSONAL INJURY DEATH AND VOID YOUR WARRANTY This product must be installed by a licensed and qualified electrician in accordance with Article 680 of the National Electrical Code NFPA 70 and with the requirements of the authority having jurisdiction and all applicable national state provincial and local electrical codes As with all electrical appli ances under no circumstances should you attempt to install repair or disassembled this water heater without first shutting off all power to the unit directly at the fuse or breaker box SERIOUSBOD ILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING All wiring wiregauge and circuit protection breakers mu
11. turn your heater to your Authorized Dealer Please call our customer service dept Are you having problems with your water heater Call TOLL FREE 877 474 6473 E mail info ecosmartus com You may also contact your Authorized Dealer for assistance

Download Pdf Manuals

image

Related Search

Related Contents

Siemens HW1405A2  Metz MZ-5 User's Manual  Dr FuelCell® Model Car Dr FuelCell® Science Kit Dr FuelCell  SEL2641R433P5  marque : liebherr reference : cce 2317 codic : 1989537  DENUBIL (10 ampollas bebibles) Cartonaje exterior  

Copyright © All rights reserved.
Failed to retrieve file