Home
Amerec K60 CP Use and Care Manual
Contents
1. Fahrenheit 38 degrees Celcius 6 The TIME and TEMP set points are remem bered by the K60 for your next bath unless power to the steam generator is lost 1 Wait forthe steam room to reach a comfort 4 Relax and enjoy the warm steam releasing 6 Afterasteambath a warm shower will give you able temperature 2 Remove clothing and jewelry 3 Enter the steam room and close the door to prevent steam from escaping tense muscles and refreshing the entire body 5 If your steam room has a shower a pleasant experience can be achieved by taking a warm shower with the steam a feeling of relaxation and is conducive to a good night s rest A cold shower will refresh you and is a good way to start a busy day or prepare you for an evening out SECTION 4 MAINTENANCE OF YOUR AK STEAM GENERATOR The steam generator steam head fittings and plumbing connections should be inspected regu larly for water leaks and damage The AK steam generator is equipped with a manual drain valve for flushing sediments from the generator tank This procedure should be scheduled monthly more often depending on local water conditions and steam bath usage 4209 40 10 27 09 Flushing Procedures 1 The generator should be cool 2 Press the control ON 3 Open the manual drain valve 4 The unit will drain without heating the water 5 Allow the water to run for a full 10 minutes 6 Push the control OFF When the water stops flowing out
2. Box 2258 Woodinville WA 98072 425 951 1120 Fax 425 951 1130 email address amerec amerec com 4209 40 10 27 09
3. the drain close the manual drain valve t Control Owners Manual For AK and Steambath Generators SECTION 5 TROUBLE SHOOTING GUIDE The troubleshooting guide is meant as a general aid only There are no user serviceable parts in the generator All repairs should be performed by a qualified service person For additional assistance or the factory authorized service person nearest you call AMEREC s Service Department at 1 800 331 0349 SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN Control won t turn ON Improper power supplied no power 1 a Make sure circuit breaker is ON Control light off or b Using a voltmeter check the voltage across the two fuses on Control improperly connected the PCA printed circuit assembly Voltage should be 208V 240V or c Check fuses if the fuse s are blown replace with 100MA Time Control cable is faulty Delay F1 or 1A Non Time Delay F2 If the fuse blows again call AMEREC s Service Department Control is faulty 2 Check control s installed per Section 6 5 in the INSTALLATION AND SERVICE INSTRUCTIONS Replace control cable call AMEREC s Service Department 4 Replace the control call AMEREC s Service Department Control OFF Generator is faulty 1 Turn off the circuit breaker Unit still makes steam 2 Call AMEREC s Service Department Water runs o
4. be tween 38 degrees and 52 degrees Celsius with an initial default of 49 degrees The 24 hour timer option is adjustable in 1 hour increments from 1 to 24 hours Other features of the K60 control should operate as described in section 2 below with the above noted exceptions SECTION 2 OPERATION OF YOUR K60 CONTROL 1 Be sure the power circuit and water supply to the generator are on 2 Press the ON OFF button on the control until the temperature is displayed 3 The generator should produce steamin 5to 10 minutes and will turn off automatically in 60 minutes or less depending on the set time The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds SECTION 3 TAKING A STEAMBATH 4 Tochange the time setting press and hold the TIME button on the control Continuing to hold the button will cause the time to increase in 5 minute increments from the prior setting At 60 minutes the time setting will scroll backwards to 5 minutes To shut down the generator press the ON OFF button 5 To change the preset temperature setting press and hold the TEMP button on the control While continuing to hold the button the tempera ture display will increase in 1 degree increments from the prior setting to 125 degrees Fahrenheit 52 degrees Celsius At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the lowest setting 100 degrees
5. closures may be slippery Use care when entering or leaving b The steam head is hot Do not touch the steam head and avoid the steam near the steam head c Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyperthermia Limit your use of steam to 10 15 minutes until you are certain of your body s reaction d Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy Pregnant or possibly pregnant women should consult a physician regarding correct exposure Obese persons and persons with a history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a steambath f Persons using medication should consult a physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate blood pressure and circulation 4 WARNING Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 degrees F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsiness and fainting The effect of hyperthermia include a Failure to perceive heat b Failure to recognize the need to exit the steambath c Unawareness of impendin
6. e under the influence of drugs Have diabetes Are under the care of a physician Are in generally poor health Children should only use the steambath under close adult supervision Scald Hazard Do Not Touch the steam head or trim during operation as they are HOT Stay at least 12 inches away from the hot steam escaping from the steam head Be careful when entering a steambath Escaping steam from an overheated steam room may cause injury AsWARNING REDUCE THE RISK OF OVERHEATING AND SCALDING 1 Exit Immediately if uncomfortable dizzy or sleepy Staying too long In a heated area 15 capable of causing overheating 2 Supervise children all times 3 Chack with a doctor before use pregnant diabetic In poor health or under medical care 4 Breathing heated alr in conjunction wilh consumption of alcohol drugs or medication Is capable of causing unconsclousness CAUTION ttm REDUCE THE RISK OF SLIPPING AND FALL INJURY Use whan entering or exiting the steam room floor may be slippery NOTE For additional safety instructions see owner s manual IMPORTANT SAFETY INSTRUCTIONS 1 READ AND FOLLOW ALL INSTRUCTIONS 2 WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times 3 WARNING To reduce the risk of injury a The wet surfaces of steam en
7. g risk d Fetal damage in pregnant women Physical inability to exit the steambath and f Unconsciousness WARNING The use of alcohol drugs or medication can greatly increase the risk of hyperthermia 4209 40 10 27 09 SAVE THESE INSTRUCTIONS Control Owners Manual For AK and Steambath Generators h SECTION 1A STEAM GENERATOR OVERVIEW The standard K60 model steam generator control features an adjustable 60 minute time and tem perature control with digital display The actual room temperature and time remaining are alter nately displayed every 5 seconds The primary control can be mounted either inside or outside CTION 1B STEAM GENERATOR OVERVIEW CELSIUS AND 24 HOUR OPTIONS the steam room and an optional secondary control is available to mount in an alternate location The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees Once the set temperature is reached the soft steam feature automatically engages cutting steam production back to a single element to provide softer billowing steam during more of the steam bath If the steam room temperature drops more than 5 degrees both elements will automatically engage As an option your K60 control can be ordered with a Celsius and or 24 hour timer in place of the Fahrenheit and 60 minute standard The Celsius option s adjustable temperature range is
8. rvice Department Note Time Temp properly displayed on K60 Unable to adjust Time or Temp Control is faulty 1 Replace control call AMEREC s Service Department setting with K60 or Generator is faulty 2 Replace PCA call Service Department Sudden increases in rate water Foaming contaminants in the water 1 Flush tank 3 times See Section 4 sputters out of steam head supply 4209 40 10 27 09 K60 Control Owners Manual For and Steambath Generators DESCRIPTION NUMBER PART NAME DESCRIPTION 28 BOLT 414 20 x 112 2 WASHER 414 LOCK POWER INPUT TERMINAL BLOCK FRONT WITH WD LABEL CONTROL HOUSING ELEMENT ACCESS CABLE TANK SENSOR TEMPERATURE SENSOR BLANKET ps TEMPERATURE SENSOR CABLE L BRACKET DRAIN NIPPLE 8 tacaro SAFETY NOT SHOWN _ _____ OPTIONAL AUTO FLUSH TERMINAL BLOCK CAP THREAD PROTECTOR UL RATING TRIPLE LEVEL REPLACEABLE ELEMENT WATER INLET SELF TIGHTENING INTER po tape RE GRAM ruses TIME DELAY F1 NOT SHOWN ruses MA NONTME DELAY F2 NOT SHOWN o e STANDOFF METAL STANDOFF coveRPLATE DECORATIVE CONTROL COVERPLATE MANUAL DRAIN ELEMENT MOUNTING BRACKET PRESSURE RELIEF BLACK PRINTED CIRCUIT ASSEMBLY GROUND gt 2 2 a steam e the healthy escape 0
9. steam o the healthy escape K60 Control Owners Manual For AK and 3K Steambath Generators AMEREG AMEREC STEAMBATH GENERATORS FOR USE WITH AMEREC AK AND 3K MODEL GENERATORS FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE WARNINGS TO THE RIGHT AND ALL INSTRUCTIONS BEFORE USING YOUR STEAMBATH POST WARNING LABEL OUTSIDE STEAMBATH FOR SAFETY WARNINGS REQUIRED POSTING ON DOOR OF STEAM ROOM OR ADJACENT TO DOOR FOR ALL COMMERCIAL INSTALLATIONS SAVE THIS MANUAL Thank you for purchasing your new AMEREC steam generator If we can be of any assistance do not hesitate to call our Service Department at 1 800 331 0349 4209 40 10 27 09 WARNING Electric Shock Hazard High voltage exists within this equipment There are no user serviceable parts in this equipment All installation and service to this equipment should be performed by qualified licensed personnel Do not exceed 30 minutes in a steambath Excessive exposure can be harmful to your health Excessive exposure can produce a rapid pulse light headedness weakness or fainting If you become uncomfortable or experience any of the above conditions exit the steambath immediately Steambaths can put stress on the body Therefore a steambath should be used only under a doctor s direction if you Are pregnant Have a heart condition Have high blood pressure Have circulatory problems Are under the influence of alcohol Ar
10. ut of steam head Generator is faulty 1 Turn off the circuit breaker 2 Turn off the water 3 Call AMEREC s Service Department Steam room too hot or cold Temperature adjustment needs setting 1 See Section 3 Temperature Adjustment 2 Call AMEREC s Service Department Control ON Temperature sensor not connected 1 Check that the sensor cable is connected to J4 on the PCA printed circuit K60 Control displays E001 assembly 2 Check the cable connection to the temperature sensor 3 Replace sensor and or cable call AMEREC s Service Department Control Temperature sensor 1 Check sensor cable for damage from nail staple puncture K60 Control displays E002 or cable shorted 2 Check sensor cable ends for frayed exposed wire strands 3 Replace sensor and or cable call AMEREC s Service Department Control ON Steambath temperature over 1 If bath is too hot shut off circuit breaker and call AMEREC s Service Control displays gt gt gt 132 55 C Department or Sensor cable is faulty 2 Treat as E002 fault above Control won t turn Control is faulty 1 Replace the control call AMEREC s Service Department Control light on Control Control light on Unit won t steam Unit has not filled completely 1 Wait at least 10 minutes after turning on the control or Generator is faulty 2 Call Se
Download Pdf Manuals
Related Search
Related Contents
CM310 Quad Serial Port utilityModule 8120-00-38 & 8120-00-40 Operating Instructions Battery Solutions & Innovations, Inc. Dispensador de agua MANUAL DEL USUARIO Pioneer SL400I Network Router User Manual 800 万画素 HD 高解像度 腕時計型ビデオカメラ取扱説明書 ECM-W20 Sartorius Moisture Analyzer Copyright © All rights reserved.