1. the light entering the room Install the underlayment in the same direction that the laminate flooring is to be installed Tape all seams Stagger end joints but avoid stair stepping appearance by varying stagger distances between adjacent rows Minimum stagger is distance 6 inches Boards cut from the opposite end of the row may be used for the next row starter boards Consejos tiles Trabaja en un rea bien iluminada Instala el material de piso en forma perpendicular a la direcci n de las vigas del piso Si fuese posible instala las tablas de forma paralela a la direcci n en que la luz entra a la habitaci n Instala el contrapiso en la misma direcci n en que se colocar el piso de madera dura Cubre todas las uniones con cinta Escalona las juntas de los extremos pero var a las distancias entre las filas adyacentes para evitar que parezcan pelda os de escalera La distancia m nima de escalonamiento es de 15 24 cm Las tablas cortadas desde el extremo opuesto de la fila pueden usarse para iniciar la siguiente fila de tablas Click Lock Technique Position the second panel in the groove of the first panel at a 20 or 30 angle Move the panel gently up and down while exerting pressure toward the first panel The panel will auto matically lock into place See diagrams below T cnica Click Lock Coloca el segundo panel en la ranura del primer panel en un ngulo de 20 o 30 Mueve el panel suavemente hacia arriba y haci
2. 5 Nunca uses un limpiador a vapor 6 No uses ninguna sustancia de limpieza que contenga cera aceite o esmalte Los residuos formar n una pel cula opaca En el caso de manchas dif ciles usa un trapo h medo o aplica un poco de alcohol o removedor de esmalte de u as en un pa o limpio frota hasta retirar la mancha 7 No uses una esponja de alambre ni ning n polvo abrasivo ya que estos rayar n el piso 8 Minimiza la exposici n a materiales abrasivos y al sucio colocando tapetes en ambos lados de las puertas que den al exterior Pedazos de alfombra en zonas de alto tr nsito tambi n son una buena idea 9 Coloca almohadillas protectoras debajo de las patas de los muebles y otros objetos pesados Man t n limpias las ruedas de los muebles 10 Mant n cortas las u as de las mascotas 11 Qu tate los zapatos con tacos clavos o tacones muy puntiagudos antes de caminar sobre el piso 12 Ten mucho cuidado al mover los muebles y los objetos pesados Coloca una l mina protectora o plywood 13 No obstruyas de ninguna forma la separaci n de expansi n alrededor del per metro del piso Warranty This product comes with manufacturer s limited residential or commercial warranty depending on which model was purchased Warranty applies to original purchaser of the flooring Please contact Customer Service Representative by calling our toll free number below for a written copy of the warranty which provides detailed terms of coverage and limitat
3. Model HL1052 877 960 8001 INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACI N Installation Grade Levels Methods and Environment This product can be installed on above or below grade levels either floated or glued indoors use only Niveles M todos y Entornos de Instalaci n Este producto puede instalarse al nivel por encima del nivel o por debajo del nivel del suelo ya sea de forma flotante o con pegamento s lo para uso en interiores CAUTION EXISTING INSTALLED RESILIENT FLOORING AND ASPHALTIC ADHESIVE MAY CONTAIN ASBESTOS OR CRYSTALLINE SILICA See Recommended Work Practices for Removal of Resilient Floor Coverings at www rfci com PRECAUCI N LOS PISOS FLEXIBLES Y EL ADHESIVO ASF LTICO PREVIAMENTE INSTALADOS PUEDEN CONTENER ASBESTO 0 S LICE CRISTALINA Consultar las Pr cticas Recomendadas para la Extracci n de los Revestimientos para Pisos Flexibles Recommended Work Practices for Removal of Resilient Floor Coverings en www rfci com CAUTION CALIFORNIA RESIDENTS This product can create wood dust and emits formaldehyde both are known to the State of California to cause cancer PRECAUCI N RESIDENTES DE CALIFORNIA Este producto puede crear aserr n y emitir formaldeh do ambos recono cidos por el estado de California como causantes de c ncer WOOD DUST Sawing sanding and machining wood products can produce wood dust It causes respiratory skin and eye irritation Avoid prolonged e
4. a abajo ejerciendo presi n contra el primer panel El panel se fijar autom ticamente en su lugar Ver los diagramas a continuaci n Yao Floating Installation Instruction Instrucciones para Instalaci n Flotante Step 1 Pre install Activities Rack up planks from several boxes Inspect product for defects If material is questionable contact the retailer immediately Do not proceed with installation Paso 1 Actividades previas a la instalaci n Agrupa tablas de varias cajas Inspecciona el producto para detectar defectos Si la condici n del material es cuestionable con tacta al vendedor minorista de inmediato No contin es con la instalaci n ESR Click Lock Technique T cnica Click Lock Step 2 Install Moisture Barrier and Underlayment For concrete let the moisture barrier run up the wall a bit before cutting to size For wood cut the moisture barrier 1 inch from the wall Install the underlayment on top of the moisture barrier See diagram 2A Paso 2 Instalar la Barrera Contra Humedad y el Contrapiso En el caso de concreto deja que la barrera de humedad suba ligeramente por la pared hasta la pared antes de cortarla al tama o que corresponda 2A Para madera corta la barrera de humedad 2 5 cm desde la pared Instala el contrapiso sobre la barrera contra humedad Ver el diagrama 2A Step 3 Install the First Row Saw off the tongue on long and short sides of th
5. a sea el taco para martillar o la palanca para llevar la siguiente tabla hacia la primera tabla hasta que las juntas de los extremos est n trabadas Repite los pasos hasta que la fila est completa Ver los diagramas a continuaci n 4A 4B 4C 4D 12 a 4D Step 5 Tight Spaces In tight spaces use the pull bar and a hammer See diagrams below 5A 5B 50 Paso 5 Espacios Estrechos En los espacios estrechos usa la barra de tracci n y un martillo Ver los diagramas m s abajo 5A 5B 5C Step 6 Pipes Pipes are handled by drilling a hole through locked end joints Drill a hole the size of the diameter plus 3 4 inch for expansion Separate the panels and rejoin them around the pipe See diagrams 6A 6B 6C Paso 6 Tuber as En el caso de las tuber as perfora un agujero a trav s de una junta de extremos que est fijada Taladra un orificio del tama o del di metro m s 3 4 pulgadas para que haya espacio para la expansi n Separa los paneles y vuelve a unirlos alrededor de la tuber a Ver los diagramas 6A 6B 6C Step 7 Under Door Frames Ensure a 3 8 inch expansion gap between floor and door jamb Use a tapping block and a hammer or a pull bar and a hammer See diagrams 7A 7B Paso 7 Por Debajo de los Marcos de las Puertas Aseg rate de que haya una s
6. e alfombra de vinilo terrazzo y otros pisos que sellen la humedad Los recubrimientos de pisos inaceptables incluyen alfombra fieltro punzonado lin leo pegado en los bordes y otros pisos que absorben la humedad Radiant Heated Floor This product can be installed over radiant heated floor Special install precautions apply The finished floor surface temperature must not exceed 85 F throughout the service life of the floor Pisos de Calefacci n Radiante Este producto puede instalarse sobre pisos de calefacci n radiante Deben tomarse precauciones espe ciales La temperatura de la superficie del piso terminado no debe exceder los 85 F a lo largo de la vida til del piso Wet Areas This product can be installed in bathrooms kitchens mud rooms foyers powder rooms and laundry rooms Do not install in saunas swimming pool areas and other similar extreme wet areas Fill all expansion gaps with water repellant sealant Seal joints between panels reas H medas Este producto puede instalarse en ba os cocinas salas de fangoterapia salas de estar tocadores y cuartos de lavado No lo instales en saunas reas de piscinas y otras zonas similares extremadamente h medas Rellena todas las separaciones de expansi n con sellador impermeable Sella las juntas entre paneles Acclimation This product does not require acclimation provided there are no extreme temperature and humidity differences between retailer transpor
7. e first plank Create expansion gap by placing spacers between the planks and the walls for expansion Saw off only the long tongues of the next planks Use the angling method to connect and lock the joints between the planks Remember to use the spacer for maintaining expansion gap See diagrams below 3A 3B Paso 3 Instalar la Primera Fila Corta con sierra la leng eta de los lados largos y cortos de la primera tabla Deja separaciones de expansi n colocando espaciadores entre las tablas y las paredes para que haya espacio para la ex pansi n En las tablas que siguen corta con s lo las leng etas largas Usa el m todo de colocaci n en ngulo para conectar y fijar las juntas entre las tablas Recuerda usar el espaciador para mantener la separaci n de expansi n Ver los diagramas m s abajo 3A 3B 3A 3B Da Step 4 Install the remaining Rows Stagger the end joints by at least 6 inches Use angling method to join and lock the long edge Use either the tapping block or pull bar to drive the next plank toward the first plank until the end joints are locked Repeat the steps until the row is complete See diagrams below 4A 4B 4C 4D Paso 4 Instalar el Resto de las Filas Escalona las juntas de los extremos en al menos 6 pulgadas Usa el m todo de colocaci n en ngulo para fijar la junta a lo largo del borde largo Usa la t cnica de colocaci n en ngulo para fijar el borde largo Usa y
8. eparaci n de expansi n de 0 95 cent metros entre el piso y la jamba de la puerta Usa un taco para martillar y un martillo o una barra de tracci n y un martillo Ver los diagramas 7A 78 Step 8 Finishing Touches Remove all spacers Install the molding on the plastic membrane that runs up the wall from under the floor Never fasten the molding to the floor Caulk around pipes and in places where molding cannot be installed Paso 8 Toques Finales Quita todos los espaciadores Instala la moldura sobre la membrana de pl stico que llega hasta la pared desde debajo del piso Nunca sujetes la moldura al piso Coloca pasta selladora alrededor de las tuber as y en lugares donde no se puedan instalar las molduras Maintenance and Care Please Note Damages resulting from improper care and maintenance of the floor are not covered by warranty 1 Sweep or dust mop regularly If vacuuming use vacuum head with a brush or felt not a head equipped with a beater 2 Do not leave any amount of liquids water juice soft drinks spills etc on the floor Clean any wet spots immediately 3 Avoid excessive exposure to water from tracking during periods of inclement weather 4 Never use a wet mop or douse floor with water or liquid cleaners Liquid can seep between the cracks and cause moisture damage 5 Never use a steam cleaner 6 Do not use any cleaning agents containing wax oil or polish Left over residue wi
9. gen de 6 mil simas de pulgada 0 15 mm Debe tener un contenido de humedad de Menos de 5 conforme a la medici n realizada con Tramex Concrete Moisture Encounter o Menos de 5 lb cada 1000 pies cuadrados 92 90 m cuadrados durante 24 horas conforme al resultado de la prueba con Cloruro de calcio ASTM F 1869 o Menos de 2 5 conforme al resultado arrojado por la prueba con Carburo de calcio CM ASTM D 4944 04 modificada Wood Subfloor It must be clean It must be flat and level 3 16 inch for every 10 feet It must have moisture content of less than 14 It must be structurally sound Moisture barrier is recommended Contrapiso de Madera Debe estar limpio Debe estar nivelado y liso 0 46 cm por cada 3 metros Debe tener un contenido de humedad menor al 14 Debe ser estable estructuralmente Se recomienda una barrera contra humedad Underlayment Sound reducing underlayment is recommended Either attached or separate Contrapiso Se recomienda un contrapiso con aislamiento ac stico Ya sea colocado en forma complementaria o por separado Existing Floor Coverings Acceptable floor coverings include linoleum vinyl carpet tile terrazzo ceramic tile and other moisture sealing floors Unacceptable floor coverings include carpet needle punch felt edge glued linoleum and other moisture absorbing flooring Recubrimientos de Pisos Existentes Los recubrimientos de pisos aceptables incluyen lin leo recubrimientos d
10. ions Technical Support For installation information and technical questions not covered in this installation guide please contact Technical Support Representative by calling the toll free number Toll Free Number 877 960 8001 Garant a Este producto cuenta con una garant a limitada del fabricante para uso residencial o comercial dependi endo del modelo adquirido La garant a aplica al comprador original del piso Comun quese con un Representante de Atenci n al Cliente llamando a nuestra L nea Gratuita por el n mero de tel fono que se muestra m s abajo para recibir una copia impresa de la garant a que establece los t rminos de la cobertura y sus limitaciones Soporte T cnico Para obtener informaci n sobre la instalaci n y hacer consultas t cnicas no cubiertas en esta gu a de in stalaci n por favor comun quese con un Representante de Soporte T cnico llamando al n mero de tel fono gratuito N mero de la L nea Gratuita 877 960 8001 Finishing Touches Toques Finales This product is Phase 2 compliant with California formaldehyde emission standards as required under CARB requirement 93120 Este producto cumple con las normas de emisi n de formaldeh dos Fase 2 del estado de California seg n lo establecido en el requisito N m 93120 de la Junta de Recursos del Aire de California CARB por sus siglas en ingl s
11. ll form a dull film For tough spots use damp cloth or apply a little alcohol or nail polish remover on the clean cloth rub till spot is removed 7 Do not use steel wool or scouring powder which will scratch the floor 8 Minimize abrasive and dirt by placing mats on both sides of exterior doors Area rugs in high traffic areas are also a good idea 9 Place protective pads beneath furniture legs and other heavy objects Keep furniture casters clean 10 Keep pets nails trimmed 11 Remove shoes with cleats spikes or exceptionally pointy heels before walking on the floor 12 Take great care when moving furniture and heavy objects Lay down a protective sheet or plywood 13 Do not obstruct in any way the expansion joint around the perimeter of your floor Mantenimiento y Cuidado Ten en Cuenta Los da os que resulten del cuidado y mantenimiento inadecuado del piso no est n cubiertos por la garant a 1 Barre y limpia el polvo con un trapo en forma peri dica Al aspirar usa el cabezal de la aspiradora con un cepillo o fieltro no un cabezal con ruedas 2 No dejes restos de l quidos agua jugo bebidas gaseosas derrames etc sobre el piso Limpia cualquier punto mojado de inmediato 3 Evita exponer el piso a cantidades excesivas de agua durante per odos de clima severo 4 Nunca uses un trapo mojado ni empapes el piso con agua o limpiadores l quidos El l quido puede penetrar entre las grietas y causar da o por humedad
12. site conditions Pouring of basement concrete floors drywall and plasterwork plumbing etc must be completed well in advance of the floor delivery Job site should be in a normal living condition i e room temperature of 60 F 80 F and relative humidity RH level of 35 60 Condiciones del Lugar de Trabajo Fabricante rechaza la responsabilidad por situaciones relacionadas con la instalaci n inadecuada o malas condiciones del lugar de trabajo Los pisos de concreto en s tanos los trabajos con drywall yeso plomer a etc deben estar terminados mucho antes de que el piso sea entregado El lugar de trabajo deber encontrarse en una condici n normal de habitabilidad es decir con una tem peratura ambiente de entre 60 F y 80 F y un nivel de humedad relativa HR de entre 35 y 60 Concrete Subfloor Requirements It must be cured It must be clean It must be flat and level 3 16 inch for every 10 feet Minimum moisture barrier is 6 mil 0 006 inch virgin polyethylene sheet It must have moisture content of Less than 5 as per Tramex Concrete Moisture Encounter or Less than 3 Ibs per 1000 square feet per 24 hours per Calcium Chloride test ASTM F 1869 or Less than 2 5 per Calcium Carbide CM test ASTM D 4944 04 modified Requisitos del Contrapiso de Concreto Debe estar curado Debe estar limpio Debe estar nivelado y plano 0 46 cm por cada 3 m La barrera m nima de humedad es una l mina de polietileno vir
13. tation and final installation site Aclimataci n Este producto no necesita aclimataci n ya que no existen diferencias extremas de temperatura y humedad entre la tienda minorista el transporte y el lugar de instalaci n final Expansion Gaps Allow expansion gap of 5 16 inch to 3 8 inch around perimeter of the floor and vertical structures Floor spanning greater than 40 feet length or width require expansion T molding Wall openings with or without door require expansion T molding Separaciones de Expansi n Deja separaciones de expansi n de entre 0 79 cm y 0 95 cm alrededor del per metro del piso y las estructuras verticales Una planta de m s de 12 metros de largo o ancho necesita molduras de dilataci n en forma de T Las aberturas en la pared ya sea que tengan puerta o no requieren molduras de expansi n en forma de T Tools You need the following tools to install this product tapping block pull bar spacers tape measure hammer circular saw saw blade with carbide tip for finish cuts work gloves Herramientas Necesitar s las siguientes herramientas para instalar este producto taco para martillar barra de trac ci n espaciadores cinta m trica martillo sierra circular sierra con punta de carburo para cortes de acabado guantes de trabajo Helpful Considerations Work in well lit area Install flooring perpendicular to the direction of the floor joists If possible install the boards parallel to the direction of
14. xposure to wood dust If high dust levels are encountered use an appropriate NIOSH designated dust mask ASERR N Serruchar lijar o trabajar la madera puede producir aserr n Causa irritaci n en las v as respiratorias la piel y los ojos Evita la exposici n prolongada al aserr n Si hay demasiado polvo usa una mascarilla antipolvo apropiada certificada por el Instituto Nacional para la Seguridad y Salud Ocupacional NIOSH en ingl s Owner Installer Responsibility Owner installer should inspect the flooring for defects prior to installation and during installation During installation do not install planks which appear to be defective After installation inspect the floor from a standing position Minor scratches can generally be repaired with the use of putty stain or filler It is an industry standard practice of flooring installation Responsabilidad del Due o Instalador El propietario instalador deber inspeccionar el piso para detectar defectos antes de la instalaci n y du rante la misma Durante la instalaci n no coloques tablas que tengan aspecto defectuoso Luego de la instalaci n ponte de pie e inspecciona el piso desde de esa posici n Por lo general los rayones menores pueden repararse con masilla tinte o relleno Esta es una pr ctica est ndar de la industria de la instalaci n de pisos Job Site Condition Manufacturer will decline responsibility for situations associated with improper installation or poor