WarmlyYours TH115-AF-12VDC Instructions / Assembly

image

Contents

1. power 12 VDC from one of them installation Read the entire document before starting the installation The floor sensor cable must not exceed 200 ft 60 m Connect the 120 V or 240 V power base to line voltage and to the load using solderless connectors for copper wires and install the base onto an electrical box NOTE The linked units can operate on different voltages e g 5 units 120 Vand 5 240 V Power supply nstallation should be carried out by an electrician and must com ply with national and local electrical codes a Do NOT install the master thermostat or a linked unit in an area where it can be exposed to water or rain To prevent severe shock or electrocution always turn the power OFF at the service panel before working with wiring Connect the power base as per the following connection dia nstall each linked unit onto an electrical box gram Use special CO ALR solderless connectors if you connect the thermostat to aluminum wires The master thermostat has two components the faceplate and the power base If you install another faceplate ensure it is configured for 15 minute cycles Load 400 230 009 C 2008 07 28 43 42vpc 1 DRIVE 2 GND 3 ot TH113 12 VDC TH114 12 VDC TH115 12 VDC TH116 12 VDC 09 INYO 1 I R lt Ss 38 Install the CT230 control module faceplate onto the power base and swi
2. BE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCI DENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WAR RANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some provinces states or regions do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY Some provinces states or regions do not allow limita tions on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary according to the province state or region Customer Assistance _ For any questions regarding product installation or operation contact us at 705 Montrichard Saint Jean sur Richelieu Quebec J2X 5K8 Canada Tel 450 358 4600 Toll free 1 800 831 AUBE Fax 450 358 4650 E mail aube service honeywell com For more information on our products visit us at www aubetech com 400 230 009 C 2008 07 28 3 3
3. MASTER THERMOSTATS LINKED UNITS ZA TH113 12VDC CT230 120GA b e TH114 12VDC CT230 120GB a TH115 12VDC CT230 240GA TH116 12VDC CT230 2406B technologies Installation and Testing Guide x u ome L2 Linked unit 1 Linked unit 2 Linked unit 3 12 VOC DRIVE DRIVE DRIVE GND GND GND Up to 10 linked units a J Master thermostat nn N PN ox ii erei Zonet Zone 2 Zone 3 UU U U Sensor cable Introduction a i l Wiring Guidelines a 5 o The wire distance between the master thermostat and each linked The system comprising a master thermostat and linked units is unit must not exceed 500 ft 150 m 20 AWG wires are recom designed for large floor heating applications whose load is too high mended y for a regular thermostat With this system the heating area is divided into zones of 15 A or less Each zone is connected to one of the linked units which are driven by the master thermostat Linked Unit Installation Each linked unit is responsible for heating its zone Each unit is Install each linked unit as follows powered by line voltage 120 V or 240 V and has its own ground fault protection device The master thermostat controls the temperature and programming if applicable for the entire floor and sends a signal to each linked unit when heating is required The master thermostat can be used to drive up to 10 linked units and receives its
4. inked Units Models CT230 120GA CT230 120GB CT230 240GA CT230 240GB Supply Load CT230 120GA 120 VAC 60 Hz 15 A resistive 1800 W CT230 120GB 120 VAC 60 Hz 15 A resistive 1800 W CT230 240GA 240 VAC 60 Hz 15 A resistive 3600 W CT230 240GB 240 VAC 60 Hz 15 A resistive 3600 W Ground fault protection CT230 120GA 5mA CT230 120GB 15mA CT230 240GA SmA CT230 240GB gt 15mA Certification c CSA us V Warranty Aube warrants this product excluding battery to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer lf at any time during the warranty period the product is determined to be defective or malfunctions Aube shall repair or replace it at Aube s option If the product is defective i return it with a bill of sale or other dated proof of purchase to the place from which you purchased it or ii contact Aube Aube will make the determination whether the product should be returned or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Aube that the defect or mal function was caused by damage which occurred while the product was in the possession of a consumer Aube s sole responsibility shall be to repair or replace the product within the terms stated above AU
5. rotection Test Test the ground fault protection of each linked unit once the master thermostat is installed and once a month thereafter to ensure it is always in working order Increase the setpoint temperature on the master thermostat above the measured floor temperature in order to activate the floor heating system TEST button light 400 230 009 C 2008 07 28 2 3 Press the TEST button on the linked unit If the TEST light does not turn On the ground fault protection is not functioning prop erly and therefore the power base of the linked unit must be replaced If the TEST light turns On continue the test Switch the linked unit to Off or Standby wait a few seconds and switch it back to On The TEST light should now be Off If the light stays On the ground fault protection is not functioning prop erly and therefore the power base of the linked unit must be replaced Place the master thermostat back to the desired temperature Technical Specifications Temperature Operation 0 C to 50 C 32 F to 122 F Storage 20 C to 50 C 4 F to 122 F Master Thermostat Models TH113 12VDC 7TH114 12VDC TH115 12VDC 7TH116 12VDC Power supply 12 V from a linked unit Maximum linked units up to 10 linked units per master thermostat Wire gauge 20 AWG NOTE Refer to the user guide of the master thermostat for its func tionalities and technical specifications L
6. tch it to STANDBY a Master Thermostat Installation Install the master thermostat as follows For ambient temperature Choose a location about 5 ft above control the floor Avoid locations where For ambient temperature control with floor tempera air outlet dead air spots behind a ture limit door direct sunlight or concealed chimneys or stove pipes there are air drafts top of staircase For floor temperature con The thermostat can be installed trol anywhere WARNING Make sure all linked units are in STANDBY mode nstall the master thermostat as follows Wire the 12 VDC power base to the nearest linked unit See the top wiring diagram WARNING Only one linked unit must be used to power the master thermostat insert the floor sensor cable through one of the two openings on the power base and connect the sensor wires to terminals 4 and 5 no polarity The sensor cable must pass outside the electrical box and follow the wall down to the floor Position the sensor cable such that it does not come in con tact with the floor heating wires The sensor must be cen tered between two floor heating wires for best temperature control Do NOT staple the sensor head epoxy section to the floor Doing so might damage the sensor The damage might not be noticeable during testing but can become apparent sev eral days later Install the power base on the wall using
7. the provided screws and wall anchors 2 4 ai IAG IZL M9 Izt j aNd 3A er p CT230 120GA CT230 120GB CT230 240GA CT230 240GB Install the control module faceplate of the master thermostat onto the power base Once the thermostat is installed return power to heating system and switch all linked units and the master thermostat to ON Ground Fault Protection A ground fault protection thermostat is different from conventional thermostats In the event of a ground fault the ground fault protection mechanism on the thermostat will trip and quickly stop the flow of electricity to prevent serious injury 3 1 Definition of a ground fault Instead of following its normal safe path electricity passes through a person s body to reach the ground For example a defective floor heating mat can cause a ground fault A ground fault protection thermostat does not protect against circuit overloads short circuits or electrical shocks For example you can still receive an electrical shock if you touch bare wires while standing on a non conducting surface such as a wood floor 3 2 Ground Fault Protection Reset When the ground fault protection mechanism trips the TEST light is On red To reset the ground fault protection switch the linked unit to Standby or Off then back to On The TEST light will go off if the ground fault protection is functioning properly 3 3 Ground Fault P