Home

SPT UC-029 Use and Care Manual

image

Contents

1. free of charge This guarantee is subject to the following terms e Sunpentown must be notified of the fault e Proof of purchase must be presented to Sunpentown s nominated representative e The warranty will be void if the product if modified misused or repaired by an unauthorized person e The warranty after repair will not be extended beyond the original one year period e All replacement parts will be new or reconditioned e Parts which are replaced become the property of Sunpentown e The warranty applies for the use of the product in the USA only What is NOT COVERED e Warranty does not include freight charges e Incidental or consequential damage caused by possible defects with this product e Damage to product caused by improper power supply voltage accident fire floods or acts of nature e Failure of product resulting from unauthorized modifications to the product e Improper installation or failure to perform the necessary maintenance This GUARANTEE is in addition to your Statutory Rights SUNPENTOWN INTERNATIONAL INC 14625 Clark Ave City of Industry CA 91745 Tel 800 330 0388 service sunpentown com www sunpentown com 10
2. 95 Cupping Mode E l fF Time 15 i 427 EA ar 427 ah 18MS On Tine 105 Kneading Mode 100U5 On Tine 95 er TT 2 BL LA ENEE Recommended use points Recommended massage Troubleshooting If your device is not operating properly please check below for common problems and suggested solutions If the recommended action does not solve the problem please contact Sunpentown Customer Service at 1 800 330 0388 or service O sunpentown com Stimulation is weak or non existent e Be sure skin is clean and pads are firmly attached to skin Be sure the pads are not touching each other Check wire connection and make sure lead wires are securely plugged in Unit s battery is low and needs to be recharged Both pads of the same wire must be attached to one person s body in order to feel sensation Devise does not turn on e Checkif battery is low and needs to be recharged e If unit was previously used switch the power switch to OFF first then back to ON Electrode pads are not sticky e The pads will lose adhesiveness over use please contact Sunpentown for replacements Skin turns red e Extended treatment on the same area stop and wait or treat another area e If problem persists contact your physician SPT Your Guarantee If this product is found to be faulty as a result of faulty materials or workmanship within one year from date of purchase it will be repaired
3. SPT Mini Electronic Pulse Massager UC 029 Operating Manual Contents ee e e EE 2 GENEE EEN EE EE EE 3 ENEE EE bO E 4 Operating INsttuotions sa ossosa kansa W R NEE EEN EE PiS 5 EE TEE 6 8 Recommended use POMS e EEN Se 8 rale RE AMA aio 9 Warranty DIO 10 Introduction UC 029 Mini Electronic Pulse Massager is a pain relief product which delivers electric impulses to tired and sore muscles These impulses are generated by the device and delivered through the connecting wires and electrodes to the target body areas The impulses mimic the action potential coming from the central nervous system to trigger contraction of the muscle UC 029 is portable compact and stylish in design It may help relief pain in various parts of the body such as the lower back shoulders joints hands and feet Using UC 029 properly will provide you with a healthy and comfortable life Features of UC 029 Mini Electronic Pulse Massager 1 Liguid crystal display LCD with battery usage indictor Build in rechargeable lithium battery DC 3 7V Freguency 0 200 Hz Main unit measure 1 69 x 0 51 x 3 30 inches Net weight of the main unit 1 2 oz 075 Ib Six massaging modes Adjustable intensity and up to 60 minutes countdown timer Accessories included 4 electrode pads 2 lead wires 1 USB adapter 1 USB cable and 2 wire pad holders RO ALSO VR 9 Safety warnings If you have one of the following conditions please consult with your physician befor
4. e purchasing or using this device Acute disease malignant tumor infective disease pregnant heart disease high fever abnormal blood pressure lack of skin sensation or an abnormal skin condition any condition reguiring the active supervision of a physician Do not use this unit if you are using an implanted electronic medical device such as a pacemaker or other life maintaining device Do not use this unit if you are wearing electronic medical devices for monitoring health functions Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as bathroom Keep this device out of reach of children Stop using this device at once if you feel pain discomfort dizziness or nausea and consult your physician Do not attempt to move the electrode pads while the device is operating Turn off the device before moving or removing the electrode pads Do not use the device around the heart on the head mouth pudendum or blemished skin areas Keep the device away from wet high temperature and or direct sunlight place Medical Electrical Eguipment needs special precautions regarding electromagnetic compatibility EMC and needs to be installed and put into service according to the EMC information provided Portable and mobile radio freguency RF communication eguipment can affect Medical Electrical Eguipment Operating temperature range 32 F to 118 F Operating humidi
5. ecommended practices Duration of 20 minute for each body area Frequency of 1 2 times per day per area Start from the lowest intensity and gradually adjust to a comfortable level on a scale level from to I to 10 Be sure the area to be treated is free of perspiration dirt and abrasions Good skin care is important for a comfortable use of device Be sure the treatment site is clean of dirt and body lotion wipe with an alcohol pad if needed When removing the pads remove by pulling in the direction of hair growth The electrode pads are disposable and should be replaced when they lose their adhesiveness However keeping electrode pads clean will extend their lifespan Replace pads to the storage holder immediately after use Avoid touching with fingertips due to grease on fingertips The lifespan of the pads will vary depending on the frequency of use To purchase additional pads please contact Sunpentown at 1 800 330 0388 and ask for part number PAD 029 Program Schematics za a fate AE dD Cupping 8 E Tavin g Scraping Massage Mode 100US off Time 15 rs E va E 80MS 18MS On Tine 205 Acupuncture Mode 1000S 100US On Tine 9S a e po HH Z E Tapping Mode 10005 off Time 15 427 427 Credi 18MS On Tine 205 Le Scraping Mode be A 850M5 i 850M5 On Tine
6. ty 10 to 85 Atmospheric pressure 400hPa to 1060hPa Part Identification Po RR Channel outlets USB port LCD screen On off switch Intensity adjustment Mode selector Timer adjustment Play Pause button USB charger USB cable Electrode pads Lead wires Operating Instructions Before initial use charge the massager for a minimum of 8 hours 1 Make sure the power switch is in the OFF position Connect lead wire s by inserting the plug into the Left and or Right channel outlets 3 Connect electrode pads to lead wires by snapping them on This should be done before applying pads to the skin 4 Place pads to treatment areas such as shoulder or lower back make sure pads do not touch each other Press down firmly and ensure a full and firm contact with skin 5 Switch the power switch to ON position 6 Press the M mode button to select desired massage mode 7 Press the button to increase massage intensity Pressing the button would decrease massage intensity 8 During a massage session pressing the center PII button would pause the operation Press again to resume 9 Press the T timer button to set massage time up to 60 minutes in 10 minute increments Note Timer continues to count down even when session is paused To conserve battery unit will power off 5 seconds after a session completes To begin another session first switch the power button to OFF position and back to ON R

Download Pdf Manuals

image

Related Search

Related Contents

Avigilon™ Control Center Player Benutzerhandbuch  BAUER T 1 M - Kinobauer.de  H8S/2638Fスタータキット ご案内\(120309\)  こちら - ケーブルテレビ富山  GE css25usw User's Manual  Dossier pedagogique Paul Klee 2014  Bissell 2X Service Manual  Spectra TFinity Site Preparation Guide  Digitus PCI USB 2.0 card  Terminal Numérique Terrestre Free-To  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.