Home
Maytag UXL5430BSS Instructions / Assembly
Contents
1. C Grease filter handle D Halogen lamp housings 00 A B C D A On Off light button B Blower off and speed minimum button C Blower speed medium button D Blower speed maximum button Operating the Light The On Off light button controls all lights Press once for On and again for Off Operating the Blower The BLOWER SPEED buttons turn the blower on and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired blower speed button Press the BLOWER OFF button a second time to turn off the blower RANGE HOOD CARE IMPORTANT Clean the hood and grease filters frequently according to the following instructions Replace grease filters before operating hood Exterior Surfaces To avoid damage to the exterior surface do not use steel wool or soap filled scouring pads Always wipe dry to avoid water marks Cleaning Method m Liquid detergent soap and water or all purpose cleanser m Wipe with damp soft cloth nonabrasive sponge then rinse with clean water and wipe dry 12 Metal Grease Filter The filters should be washed frequently Place metal filters in dishwasher or hot detergent solution to clean Let filter dry thoroughly before replacing it Turn off fan and lights Allow halogen lamp to cool 1 Remove each filter by pulling the spring release handle and then pulling down the filter
2. 17 EXIGENCES D INSTALLATION cernere ennemis 19 Outils et pl ces itae coe ete 19 Exigences d emplacement 19 Exigences concernant 20 Sp cifications lectriques 22 INSTRUCTIONS 23 Pr paration de l emplacement 23 Installation de la hotte 25 Raccordement du circuit d vacuation 26 Achever l installation ss 27 UTILISATION DE LA HOTTE nennen nennen 27 Commandes de la hotte de cuisini re 27 ENTRETIEN DE LA HOTTE rennen enne nnnm nnne 27 2 UR REPRE times 27 SCHEMAS DE C BLAGE rennen treten tentent tton 29 ASSISTANCE OU SERVICE eere eere ener rennen nana 30 AU Canada evene rine ARMIN hanes 30 ACCESSOIRES Lui let 30 GARANTIE 2 2 TE 31 RANGE HOOD SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING Thes
3. A Spring release handle 2 Wash metal filters as needed in dishwasher or hot detergent solution 3 Reinstall the filter by making sure the spring release handles are toward the front Insert metal grease filter into upper track 4 Pull the spring release handle down Push up on metal filter and release handle to latch into place 6 Repeat steps 1 5 for the other filter e Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up to 6 months with normal use Replace with Charcoal Filter Kit Number W10272068 To replace charcoal filter 1 Cover the grille that covers the blower motor with the charcoal filter so that the slots on the filter correspond to the pins on the sides of the motor grille A Charcoal filter B Pins C Blower motor 2 Turn the charcoal filter clockwise to lock it 3 Repeat steps 1 2 on the other filter Replacing a Halogen Lamp Turn off the range hood and allow the halogen lamp to cool To avoid damage or decreasing the life of the new bulb do not touch bulb with bare fingers Replace bulb using tissue or wearing cotton gloves to handle bulb If new lamps do not operate make sure the lamps are inserted correctly before calling service 1 Disconnect power 2 Push up on the lens and turn it counterclockwise 3 Remove the bulb and replace it with a 120 volt 50 watt maximum halogen bulb with a GU10 base Turn it clo
4. Pour taille de placard 30 x 18 76 2 cm x 45 7 cm Assembler la plaque d extension arri re du panneau avant de 30 x 6 76 2 cm x 15 2 cm voir la section Assistance ou Service pour commander au panneau avant de 30 x 12 76 2 cm x 30 5 cm fourni avec la hotte l aide des huit vis de 4 2 x 8 mm fournies avec la plaque d extension arri re du panneau avant A Vis de 4 2 x 8 mm 8 B Panneau avant C Plaque d extension du panneau avant Fixer le panneau avant de 30 x 18 76 2 cm x 45 7 cm la caisse de la hotte l aide de quatre vis t te plate de 3 5 x 9 5 mm et deux vis t te bomb e de 4 2 x 15 mm Serrer pour fixer l ensemble Pour taille de placard 36 x 18 91 4 cm x 45 7 cm Fixer le panneau avant de 36 x 18 91 4 cm x 45 7 cm voir la section Assistance ou Service pour commander la caisse de hotte l aide de quatre vis t te plate de 3 5 x 9 5 mm et de deux vis t te bomb e de 4 2 x 15 mm Serrer pour fixer l ensemble Raccorder le connecteur des lampes Installations avec d charge l ext rieur 1 Connecter le circuit d vacuation sur l ouverture de d charge de la hotte Serrer le point de connexion avec des brides Installation sans d charge l ext rieur recyclage 1 Connecter le circuit d vacuation sur l ouverture de d charge de la hotte Serrer le point de connexion avec des brides 2 Installer les filtres charbon Voir la section
5. A Measurement A B Horizontal centerline of vent opening C Range hood liner Remove the vent duct from the range hood liner Transfer measurement A to the cabinet back wall Measure from the underside of the cabinet Mark the cutout as shown Use a saber saw or keyhole saw to cut a round opening through the back of the cabinet and the exterior wall for the vent Go to Step 3 A Measurement A B Centerline C 6 15 9 cm round cutout Non Vented recirculating Installation Through the Soffit Cabinet Measure and mark the centerline of the cabinet to the soffit above Measure from the bottom of the cabinet to the centerline of the where the vent will come through the soffit Mark the location and use a saber saw or keyhole saw to cut a 524 14 6 cm hole for the vent cover A Vent cover B Centerline Measure and mark the centerline location for the cutout in the cabinet top Use a saber saw or keyhole saw to cut an opening for the vent A Cutout B See chart below C 7 19 7 cm centerline to cabinet front D Centerline Cabinet Height Hole Shape and Size 12 80 5 cm deep x 8 wide 15 9 cm x 20 3 cm rectangular opening in the cabinet top is required for damper transition clearance 15 38 1 cm A 15 9 cm diameter round opening is cabinet or soffit required installation 18 45 7 cm or 534 14 6 cm diameter round opening is 24 61
6. 30 76 2 CM RANGE HOOD LINER CAISSE DE HOTTE POUR CUISINI RE DE 30 76 2 CM Table of Contents Table des mati res 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION R SIDENTIELLE UNIQUEMENT LI30ZB W10487239C TABLE OF CONTENTS RANGE HOOD SAFETY 2 rire ennemie 2 INSTALLATION REQUIREMENTS ins 4 Tools and Parts ste cete ectetur i eec 4 Location Requirements esses eene 4 Venting Requirements 5 Electrical Requirements 7 INSTALLATION INSTRUCTIONS eere 8 Prepare L OCatlOnis 2er e eet sae cea aane Ys tain 8 Install Range Hood aee 10 Connect the Vent System 11 Complete Installation 11 RANGE HOOD USE ne nus sienne 12 Range Hood Controls ss 12 RANGE HOOD ennt nant nant nnnn 12 CE aaO teen etie Reg o eR ret thea east Rage nare 12 WIRING DIAGRAM nnne nnne nnnm n nana nnne anna 14 ASSISTANCE OR 15 S A cio acc depleted bs 15 In Canada ice ie eee eb eoe e ve e 15 ACCOSSOLGOS EUR E RUE A ee ei S ae 15 WARRANTY ss 16 TABLE DES MATI RES S CURIT DE LA HOTTE DE
7. 0 cm required For non vented recirculating installations only the range hood can be vented indoors through the top of the cabinet For non vented recirculating installations charcoal filters are necessary See the Range Hood Care section for instructions on installing charcoal filters The Recirculation Kit Part Number W10490330 must be used Complete Preparation 3 If not yet attached install the 6 15 2 cm vent transition the top of the range hood liner using two 3 5 x 9 5 mm screws AWARNING 4 Locate side mounting bracket flush to the bottom of the cabinet side and against the inside of the front cabinet face Excessive Weight Hazard Orient the bracket depending on the width of your cabinet as i depicted in the diagrams below Drill 3 mm pilot holes in Use two or more people to move and install 6 places attach a bracket using three 4 5 x 13 mm screws to range hood each side of the cabinet and tighten Additional washers in Failure to do so can result in back or other injury hardware package are supplied as spacers for cabinet walls thinner than 72 13 mm EN i Using 2 or more people lift the hood liner into its mounted Bracket Orientation for 30 76 2 cm Cabinet location Attach with four 4 2 x 19 mm screws into the slotted openings Do not tighten screws 30 76 2 cm cabinet Screws 4 5 x 13 mm 6 C Washers optional D Mounting bracket 2 positio
8. Entretien de la hotte Pour commander des ensembles de rechange voir la section Assistance ou service 1 R installer les filtres graisse Voir la section Entretien de la hotte AVERTISSEMENT D Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique 2 Brancher le cordon d alimentation 3 broches dans la prise 3 alv oles reli e la terre situ e dans le placard qui se trouve au dessus de la hotte 3 Contr ler le fonctionnement du ventilateur de la hotte et de la lampe Voir la section Utilisation de la hotte Si la hotte ne fonctionne pas d terminer si un disjoncteur S est ouvert ou si un fusible du domicile est grill D connecter la source de courant lectrique et inspecter les connections du c blage REMARQUE Pour pouvoir tirer le plus grand parti de la nouvelle hotte de cuisini re lire la section Utilisation de la hotte UTILISATION DE LA HOTTE La hotte de cuisini re est congue pour extraire fum e vapeurs de cuisson et odeurs de la zone de la table de cuisson Pour obtenir les meilleurs r sultats mettre le ventilateur de la hotte en marche avant d entreprendre une cuisson et la laisser fonctionner pendant plusieurs minu
9. air filters or water filters Consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use or when it is used in a manner that is contrary to published user or operator instructions and or installation instructions 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrical or plumbing codes or use of consumables or cleaning products not approved by Whirlpool 5 Cosmetic damage including scratches dents chips or other damage to the finish of your major appliance unless such damage results from defects in materials or workmanship and is reported to Whirlpool within 30 days from the date of purchase 6 Any food loss due to refrigerator or freezer product failures 7T Costs associated with the removal from your home of your major appliance for repairs This major appliance is designed to be repaired in the home and only in home service is covered by this warranty 8 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 9 Expenses for travel and transportation for product service if your major appliance is located in a remote area where service by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not insta
10. appeler sans frais le Centre pour l eXp rience de la client le de Whirlpool Canada LP au 1 800 807 6777 Nos consultants vous renseigneront sur les sujets suivants m Caract ristiques et sp cifications sur toute notre gamme d appareils lectrom nagers Consignes d utilisation et d entretien Ventes d accessoires et de pi ces de rechange R f rences aux marchands locaux aux distributeurs de pi ces de rechange et aux compagnies de service Les techniciens de service d sign s par Whirlpool Canada LP sont form s pour remplir la garantie des produits et fournir un service apr s la garantie partout au Canada 30 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez soumettre par crit toute question ou pr occupation Whirlpool Canada LP l adresse suivante Whirlpool Canada LP Centre pour l eXp rience de la client le 200 6750 Century Ave Mississauga Ontario L5N 0B7 Veuillez inclure dans votre correspondance un num ro de t l phone o l on peut vous joindre dans la journ e Ensemble de recyclage pour installations sans d charge l ext rieur uniquement Commander la pi ce num ro W10490330 Filtres charbon de rechange pour installations sans d charge l ext rieur uniquement Commander la pi ce num ro W10272068 Plaque d extension arri re pour panneau avant pour placard de 30 x 18 76 2 cm x 45 7 cm Commander la pi ce num ro W10490327 Pannea
11. appropri es et tracer l axe central de l ouverture dans le sommet du placard Utiliser une scie sauteuse ou scie guichet pour d couper une ouverture pour le passage du conduit d vacuation Reporter la dimension A sur la paroi arri re du placard Prendre les mesures partir de la face inf rieure du placard Marquer le p rim tre de l ouverture d couper voir l illustration Utiliser une scie sauteuse ou une scie guichet pour d couper une ouverture circulaire travers l arri re du placard et le mur ext rieur pour l vacuation Passer l tape 3 D gt w IN M A Ouverture B Voir le tableau ci dessous C 7 19 7 cm entre l axe central et l avant du placard D Axe central A Mesure A B Axe central C Ouverture d coup e circulaire de 6 15 9 Installation sans d charge l ext rieur recyclage Hauteur du Taille et forme du trou travers le soffite placard placard 12 80 5 cm Une ouverture rectangulaire de 64 de profondeur x 8 de largeur 15 9 cm x 20 3 cm dans le sommet du placard est Mesurer la distance entre le bas du placard et l axe central obligatoire pour tablir le d gagement au point o le conduit d vacuation ressort du soffite n cessaire au clapet anti reflux Relever les mesures appropri es et tracer l axe central du placard jusqu au soffite situ au dessus Indiquer l emplacement et utiliser une scie sauteuse ou
12. ensuite Des rondelles suppl mentaires sont fournies dans le sachet de quincaillerie pour tre utilis es comme cales pour les parois de placard dont l passeur est inf rieure 7 13 mm Orientation de la bride pour un placard de 30 76 2 cm A Placard de 30 76 2 cm B Vis de 4 2 x 13 mm 6 C Rondelles facultatif D Bride de montage 2 position pour un placard de 30 76 2 cm Orientation de la bride pour un placard de 36 91 4 cm A Placard de 36 91 4 cm B Vis de 4 2 x 13 mm 6 C Rondelles facultatif D Bride de montage 2 position pour un placard de 36 91 4 cm Installer le circuit d vacuation selon la m thode requise Utiliser un calfeutrant pour assurer l tanch it au point de travers e du mur ext rieur ou du toit AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisiniere Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure l aide d au moins 2 personnes soulever la caisse de la hotte et l installer Fixer quatre vis de 4 2 x 19 mm dans les encoches Ne pas serrer les vis A Placard B Auvent de la hotte C Vis de 4 2 x 19 mm 8 D Cales Facultatives Au besoin ins rer des cales de chaque c t de l auvent et de la plaque de montage pour permettre le d gagement n cessaire et centrer l auvent dans le placard Al
13. ft 2 8 m System length 14 ft 4 3 m Non Vented recirculating Installations Through the Soffit Cabinet If it is not possible to vent cooking fumes and vapors to the outside the range hood can be used in the non vented recirculating version using a charcoal filter Recirculation Kit Part Number W10490330 is available from the dealer or an authorized parts distributor Through Cabinet Through Soffit A A G D F A Ceiling F Cabinet B Vent cover G Wall C Soffit H 12 30 5 cm min cabinet D 6 15 2 cm vent height E Range hood 1 17 43 2 cm min vent cover height NOTE 12 30 5 cm high cabinets without a soffit may allow the 6 vent and vent cover to be seen AWARNING I Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock IMPORTANT The range hood must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 No 0 M91 latest edition If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be o
14. l ment d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti retour doit tre plac du c t air froid de la r sistance thermique L l ment d isolation thermique doit tre aussi proche que possible de l endroit o le circuit d vacuation s introduit dans la partie chauff e de la maison Air d appoint Les codes du b timent locaux peuvent exiger l emploi d un syst me de renouvellement de l air introduction d air d appoint lors de l utilisation d un syst me d aspiration de d bit sup rieur une valeur pieds cubes par minute sp cifi e Le d bit sp cifi en pieds cubes par minute varie d une juridiction l autre Consulter un professionnel des installations de chauffage ventilation climatisation au sujet des exigences sp cifiques applicables dans la juridiction locale M thodes d vacuation Cette hotte a t configur e l usine pour la d charge travers le toit ou travers le mur Le syst me de d charge requis pour l installation n est pas fourni Un circuit d vacuation avec conduit circulaire de 6 15 2 cm est recommand D charge travers le toit vacuation par le mur B A Calcul de la longueur effective du circuit d vacuation Pour la r alisation du circuit d vacuation on recomm
15. mur ou travers le toit Pour les installations sans d charge l ext rieur recyclage il faudra aussi m Ensemble de recyclage Commander la pi ce num ro W10490330 Voir la section Assistance ou service pour commander Pi ces fournies Retirer les pi ces de leur emballage V rifier que toutes les pi ces sont pr sentes m Clapet anti retour m Sachet de quincaillerie Comprend Instructions d installation et Guide d utilisation et d entretien 2 brides de montage 6 cales d espacement 10 vis bois de 4 5 x 13 mm 2 vis m taux de 4 2 x 15 mm 4 vis de ferblantier t te plate de 3 5 x 9 5 mm 8 vis de ferblantier de 4 2 x 19 mm 2 vis de ferblantier de 3 5 x 9 5 mm 1 panneau de surface de 30 x 12 76 2 x 30 5 cm 2 filtres graisse m talliques Adaptateur T10 TORX 8 rondelles m talliques 8 rondelles en plastique T TORX est une marque d pos e de Saturn Fasteners Inc IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Confier l installation de la hotte un technicien qualifi C est l installateur qu incombe la responsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre sur la paroi arri re gauche de la hotte Installer la hotte de cuisini re distance de toute zone expos e des courants d air comme fen tres
16. off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA m WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device READ AND SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools needed Level Drill Ya 3 mm drill bit Pencil Pliers Tape measure or ruler Caulking gun and weatherproof caulking compound Phillips screwdriver Flat blade screwdriver Saber or keyhole saw Vent clamps Metal snips Parts needed m 6 15 2 cm round metal vent system For vented installations you will need m 1 wall or roof cap For non vented recirculating installations you will also need m Recirculation Kit Part Number W10490330 See the Assistance or Service section to ord
17. pas lavable Celui ci devrait durer pendant six mois dans des conditions d utilisation normales Remplacer par l ensemble de filtre charbon num ro W10272068 Remplacement du filtre charbon 1 Placer le filtre charbon sur la grille prot geant le moteur du ventilateur de fa on ce que les encoches du filtre correspondent aux tiges situ es sur les c t s de la grille de protection du moteur A Filtre charbon B Tiges C Moteur du ventilateur 28 2 Faire pivoter le filtre charbon dans le sens horaire pour l emboiter 3 R p ter les tapes 1 2 pour l autre filtre Remplacement d une lampe halogene Interrompre l alimentation de la hotte attendre le refroidissement de la lampe halog ne Pour viter d endommager ou de r duire la long vit de l ampoule neuve ne pas toucher l ampoule avec les doigts nus Remplacer l ampoule en la manipulant avec un mouchoir de papier ou des gants de coton Si les nouvelles lampes ne fonctionnent pas v rifier que chaque lampe est correctement ins r e dans sa douille avant de demander l intervention d un d panneur 1 D connecter la source de courant lectrique 2 Pousser la plaque de verre vers le haut et la tourner dans le sens antihoraire 3 Retirer l ampoule et la remplacer par une ampoule halog ne de 120 volts 50 watts maximum avec culot GU10 La tourner dans le sens horaire pour l emboiter 4 R p ter les tapes 2 3 pour l au
18. portes et bouches de chauffage Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Ces dimensions tiennent compte des valeurs minimales des d gagements de s paration Avant d effectuer des d coupages consulter les instructions d installation de la table de cuisson cuisini re On doit disposer d une prise de courant lectrique reli e la terre Voir la section Sp cifications lectriques La hotte a t configur e l usine pour une installation avec d charge l ext rieur travers le toit ou le mur Pour une installation sans d charge l ext rieur recyclage voir Installation sans d charge l ext rieur recyclage travers le soffite placard la section Pr paration de l emplacement L ensemble de recyclage pi ce num ro W10490330 est disponible chez votre marchand ou chez un distributeur de pi ces autoris Assurer l tanch it au niveau de chaque ouverture d coup e dans le plafond ou le mur pour l installation de la hotte de cuisini re Installation dans une r sidence mobile L installation de cette hotte doit satisfaire aux exigences de la norme Manufactured Home Construction Safety Standards Titre 24 CFR partie 328 anciennement Federal Standard for Mobile Home Construction and Safety titre 24 HUD partie 280 lorsque cette norme n est pas applicable l installation doit satisfaire aux crit res de la plus r cente dition de la norme Manuf
19. 1 9 cm thick filler strip not supplied may be required for some types of cabinets See Step 3 in the Install Range Hood section E D Y C Y B A Bottom of cabinet cutout B Bottom must be cut flush to the inside walls of the cabinet C 10 26 4 cm min from the inside of the cabinet front face D 32 1 9 cm thick front face required for cabinet bottom E Front of cabinet Complete cabinet preparation following the instructions for your type of venting Determine venting cutout locations and cut out vent openings in the cabinets walls and or soffit Venting Outside Through the Roof Measure and mark the lines as shown Use a saber saw or keyhole saw to cut an opening through the top of the cabinet and the roof for the vent Go to Step 3 A Cutout 674 15 9 C 734 19 7 cm centerline to cabinet front D Centerline NOTE For 12 30 5 cm high cabinets 6 deep x 8 wide 14 6 cm x 20 3 cm rectangular opening in the cabinet top is required for damper transition clearance Venting Outside Through the Wall Install the 6 15 2 cm vent transition to the top of the range hood liner using two 3 5 x 9 5 mm screws Assemble the vent duct that you will use over the 6 15 2 cm vent transition Measure from the bottom of the range hood liner to the horizontal centerline of the vent opening A B Y
20. 1 East Pleasant Valley Road Cleveland Ohio 44131 5575 m Une alimentation de 120 volts 60 Hz CA seulement de 15 ou 20 amp res prot g e par un fusible est requise On recommande galement d utiliser un fusible ou un disjoncteur temporis Il est recommand de raccorder la hotte sur un circuit distinct exclusif cet appareil m Cette hotte est quip e d un cordon d alimentation lectrique de liaison la terre trois broches m Pour minimiser les risques de choc lectrique on doit brancher le cordon sur une prise de courant de configuration correspondante 3 alv oles reli e la terre et install e conform ment aux codes et r glements locaux Si une prise de courant de configuration correspondante n est pas disponible le client a la responsabilit et l obligation de faire installer par un lectricien qualifi une prise de courant correctement reli e la terre m Laprise 3 broches reli e la terre doit se trouver dans un placard situ au dessus de la hotte une distance maximale de 33746 85 0 cm partir du point duquel le cordon d alimentation sort de la hotte La prise 3 broches reli e la terre doit tre accessible une fois la hotte install e Voir w 33746 85 cm l illustration INSTRUCTIONS DE MISE LA TERRE W Pour une hotte reli e la terre et connect e par un cordon Cette hotte doit tre reli e la terre Au cas o un court circuit se produirait
21. FEU DE GRAISSE SUR LA CUISINI RE m Ne jamais laisser un l ment de surface fonctionner puissance de chauffage maximale sans surveillance Un renversement d bordement de mati re graisseuse pourrait provoquer une inflammation et la g n ration de fum e Utiliser une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors de la cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber savoir cr pes Suzette cerise jubil e steak au poivre flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APR S LE D CLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINI RE APPLIQUER LES RECOMMANDATIONS SUIVANTES m Placer sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur VEILLER VITER LES BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PIECE ET APPELER LES POMPIERS m NE JAMAIS PRENDRE EN MAIN UN R CIPIENT ENFLAMME vous risquez de vous br ler m NE PAS UTILISER D EAU ni un torchon humide ceci po
22. LIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONF RE DES DROITS JURIDIQUES SP CIFIQUES ET VOUS POUVEZ GALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION UNE AUTRE Si vous r sidez l ext rieur du Canada et des 50 tats des tats Unis contactez votre marchand Whirlpool autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section D pannage du Guide d utilisation et d entretien Apr s avoir v rifi la section D pannage de l aide suppl mentaire peut tre trouv e en v rifiant la section Assistance ou service ou en appelant Whirlpool Aux E U composer le 1 800 253 1301 Au Canada composer le 1 800 807 6777 6 12 Conservez ce manuel et votre recu de vente ensemble pour 2 Nom marchand r f rence ult rieure Pour le service sous garantie vous devez pr senter un document prouvant la date d achat ou Adresse d installation Inscrivez les renseignements suivants au sujet de votre gros Num ro de t l phone appareil m nager pour mieux vous aider obtenir assistance ou service en cas de besoin Vous devrez conna tre le num ro de mod le et le num ro de s rie au complet Vous trouverez ces renseignements sur la plaque signal tique situ e sur le produit Num ro de mod le Num ro de s rie Date d achat 31 W10487239C 2012 Whirlpool Corporation All rights reserved Used under license in C
23. actured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A ou des codes locaux 19 Dimensions du produit A 38 1 0 cm D 2 5 1 cm 1178 30 2 cm B 30 76 2 cm 5 12 7 cm 1778 45 4 cm 36 91 4 cm E 10 26 4 cm H 916 23 1 cm C 26 66 1 cm F 34 1 9 cm 1 13 33 7 cm REMARQUE Des placards de 30 76 2 cm de largeur peuvent Dimensions du placard poss der une profondeur de 12 30 5 cm ou 18 45 7 cm Des placards de 36 91 4 cm de largeur n cessitent une profondeur de 18 45 7 cm j Pour des placards de 18 45 7 cm de profondeur il faudra acheter s par ment une Plaque d extension arri re pour panneau avant de 30 76 2 cm ou un Panneau avant de IE 36 91 4 cm Voir la section Assistance ou service pour commander lB C eee m Lecircuit d vacuation doit d charger l air l ext rieur Sp except pour les installations sans d charge l ext rieur ge recyclage lee E 00 m Ne pas terminer le circuit d vacuation dans un grenier ou EOS dans un autre espace clos IL m Ne pas utiliser une bouche de d charge murale de 4 10 2 cm Sa normalement utilis e pour un quipement de buanderie ae m Utiliser un conduit m tallique uniquement Un conduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou en aluminium m La lo
24. anada Tous droits r serv s Utilis e sous licence au Canada 8 12 Printed in Mexico Imprim au Mexique
25. ande un conduit de 6 15 2 cm de diam tre avec une longueur maximale de 35 pi 10 7 m Pour une performance optimale ne pas utiliser plus de trois coudes 90 Pour calculer la longueur effective du circuit d vacuation n cessaire additionner les longueurs quivalentes en pieds m tres de tous les composants utilis s dans le circuit Composant 6 15 2 cm Coude 45 2 5 pi 0 8 m Coude 90 5 0 pi 1 5 m Exemple de circuit d vacuation 6 15 2 cm E Bouche de d charge murale Coude 90 lt 6 pi 1 8 m eo gt 3 A Conduit de dia 6 15 2 cm pour d charge a travers le toit B Bouche de d charge sur toit A Conduit de dia 6 15 2 cm pour d charge a travers le mur B Bouche de d charge murale Longueur maximum 35 pi 10 7 m 1 coude a 90 5 pi 1 5 m 1 bouche de d charge murale 0 pi 0 m Section droite de 9 pi 2 8 m 9 pi 2 8 m Longueur totale 14 pi 4 3 m 21 Installation sans d charge l ext rieur recyclage travers le soffite placard S il n est pas possible d vacuer les fum es et vapeurs de cuisson l ext rieur on peut employer la version sans d charge l ext rieur recyclage de la hotte dot e d un filtre charbon L ensemble de recyclage pi ce num ro W10490330 est disponible chez votre marchand ou chez un distributeur de pi ces autoris travers le placard tra
26. btained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 m 120 volt 60 Hz AC only 15 or 20 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range hood be provided m Thisrange hood is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type outlet grounded in accordance with local codes and ordinances If a mating outlet is not available it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician The grounded 3 prong outlet is to be located inside the cabinet above the range hood at a maximum distance of 33746 85 0 cm from where the power cord exits the hood The grounded 3 prong outlet must be accessible after installation of the range hood See illustration a w 3374s 85 L GROUNDING INSTRUCTIONS W For a grounded cord connected range hood This range hood must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This range hood is equipped with a cord having a grounding wir
27. ckwise to lock it into place 4 Repeat steps 2 3 for the other bulb if needed 5 Reconnect power 13 WIRING DIAGRAM SWITCH OPERATION FUNCTION POSITION Mechanical Push Buttons 4 buttons 3 speeds ial bil Motor Chassis Motor Resistance Ohms BUBK 288 Motor Characteristics BU GY Power Supply 120V BU R S 1 3 240 W Room Temp 73 4 F 23 C 14 ASSISTANCE OR SERVICE When calling for assistance or service please know the purchase date and the complete model and serial number of your appliance This information will help us to better respond to your request If you need replacement parts If you need to order replacement parts we recommend that you use only factory specified parts Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance To locate factory specified replacement parts in your area call us or your nearest designated service center Call the Whirlpool Customer eXperience Center toll free 1 800 253 1301 Our consultants provide assistance with Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc m Referrals to local dea
28. cold air side of the thermal break The break should be as close as possible to where the vent System enters the heated portion of the house Makeup air Local building codes may require the use of makeup air systems when using ventilation systems with greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods This range hood is factory set for venting through the roof or through the wall The vent system needed for installation is not included A 6 15 2 cm round vent system is recommended Roof Venting Wall Venting A 6 15 2 cm vent through the roof B Roof cap A 6 15 2 cm vent through the wall B Wall cap Calculate Vent System Length The recommended vent system is 6 15 2 cm round vent with a maximum length of 35 ft 10 7 m For the best performance use no more than three 90 elbows To calculate the length of the system add the equivalent feet meters for each of the vent pieces used in the system Example vent system 6 15 2 cm Wall cap 90 elbow lt 6 ft 1 8m 3 ft 0 93 m Vent Piece 6 15 2 cm 45 elbow 2 5 ft 0 8 m 9 90 elbow 5 0 ft 1 5 m J Maximum Length 35 ft 10 7 m 1 90 elbow 5 ft 1 5 m 1 wall cap 0 ft 0 m 9 ft 2 8 m straight 9
29. e d appui de 34 1 9 cm d paisseur non fournie sera peut tre n cessaire pour certains types de placards Voir l tape 3 de la section D charge l ext rieur travers le mur Installation de la hotte E D Fixer le raccord de transition du conduit de 6 15 2 cm au sommet de la caisse de la hotte l aide de deux vis de Y 3 5 x 9 5 mm Assembler le conduit d vacuation qui sera utilis sur le raccord de transition du conduit de 6 15 2 cm Mesurer la distance entre le bas de la caisse de la hotte et l axe central horizontal de l ouverture d vacuation A A C B SES x i y mo B 1 I A Ouverture dans le fond du placard A B Le d coupage du fond du placard doit tre en affleurement avec C les parois internes du placard 10 26 4 cm min depuis l int rieur de la partie avant du placard D paisseur de 34 1 9 cm obligatoire pour le fond du placard E Avant du placard 2 Terminer la pr paration du placard conform ment aux Y instructions correspondant au type d vacuation du domicile D terminer l emplacement des ouvertures d a ration et d couper les ouvertures dans les placards les murs et ou les soffites A Mesure A B Axe central horizontal de l ouverture d vacuation C Caisse de la hotte 23 Retirer le conduit d vacuation de la caisse de la hotte Relever les mesures
30. e with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the range hood is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the range hood SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS N 4 2 It is recommended that the vent system be installed before the range hood is installed Before making cutouts make sure there is proper clearance within the ceiling or wall for vent fittings Making the cutout to the bottom of the cabinet may be easier to do prior to mounting the cabinet to the wall Disconnect power Determine which venting method to use roof wall or non vented Select a flat surface for assembling the range hood Place covering over that surface AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury Using 2 or more people lift range hood onto covered surface Range Hood Cabinet Cutout Use a saber saw or keyhole saw to cut out the cabinet bottom inside the cabinet frame NOTE Frameless type cabinets require 94 1 9 cm front lip in the cabinet bottom A 34
31. e words mean A DANGER WARNING You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING m Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Do not operate any fan with a damaged cord or plug Discard fan or return to an authorized service facility for examination and or repair Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standard
32. ect the vent system to the range hood vent opening Seal the connection with clamps 2 Install charcoal filters See the Range Hood Care section To order replacement kits see the Assistance or Service section 1 Replace grease filters See the Range Hood Care section AWARNING 4 A Screws 3 5 x 9 5 mm flat head 4 B Face plate 30 x 12 76 2 cm x 30 5 cm shown C Cabinet 30 x 12 76 2 cm x 30 5 cm shown D Screws 4 2 x 15 mm truss head 2 For cabinet size 30 x 12 76 2 cm x 30 5 cm Attach the 30 x 12 76 2 cm x 30 5 cm face panel supplied with range hood to the hood liner using four 3 5 x 9 5 mm Plug into a grounded 3 prong outlet flat head screws and two 4 2 x 15 mm truss head screws Tighten to secure For cabinet size 30 x 18 76 2 cm x 45 7 cm Assemble the 30 x 6 76 2 cm x 15 2 cm face panel rear Do not use an extension cord extension see the Assistance or Service section to order Fail to follow th instructi It in death to the 30 x 12 76 2 cm x 30 5 cm face panel supplied with pisi e te the range hood using eight 4 2 x 8 mm screws supplied with the face panel rear extension Electrical Shock Hazard Do not remove ground prong Do not use an adapter 2 Plug 3 prong power cord into a grounded 3 prong outlet located inside t
33. ented installations only Order Part Number W10490330 Replacement Charcoal Filters for non vented installations only Order Part Number W10272068 Face Panel Rear Extension for 30 x 18 76 2 cm x 45 7 cm cabinet Order Part Number W10490327 Face Panel for 36 x 18 91 4 cm x 45 7 cm cabinet Order Part Number W10490310 15 WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase when this major appliance is operated and maintained according to instructions attached to or furnished with the product Whirlpool Corporation or Whirlpool Canada LP hereafter Whirlpool will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship Service must be provided by a Whirlpool designated service company This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased Outside the 50 United States and Canada this limited warranty does not apply Proof of original purchase date is required to obtain service under this limited warranty ITEMS EXCLUDED FROM WARRANTY This limited warranty does not cover 1 Service calls to correct the installation of your major appliance to instruct you on how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs
34. er Parts supplied Remove parts from packages Check that all parts are included m Damper m Hardware package Includes Installation Instructions and Use and Care Guide 2 mounting brackets 6 spacers 10 4 5 x 13 mm wood screws 2 4 2 x 15 mm machine screws 4 8 5 x 9 5 mm flat head sheet metal screws 8 4 2 x 19 mm sheet metal screws 2 8 5 x 9 5 mm sheet metal screws 1 30 x 12 76 2 x 30 5 cm face panel 2 metal grease filters T10 TORX adapter 8 metal washers 8 plastic washers is a registered trademark of Saturn Fasteners Inc 4 IMPORTANT Observe all governing codes and ordinances Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located inside the liner behind the filter on the left wall of the range hood Range hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Consult your cooktop range manufacturer installation instructions before making any cutouts Grounded electrical outlet is required See Electrical Requirements section The range hood is factory set for vented installations through the roof or wall For non vented recirculating installations see Non Vented reci
35. he cabinet above the range hood 3 Check the operation of the range hood fan and light See Range Hood Use section If range hood does not operate check to see whether a circuit breaker has tripped or a household fuse has blown Disconnect power and check wiring connections NOTE To get the most efficient use from your new range hood read the Range Hood Use section A Screws 4 2 x 8 mm 8 B Face panel C Face panel rear extension Attach the 30 x 18 76 2 cm x 45 7 cm face panel assembly to the hood liner using four 3 5 x 9 5 mm flat head screws and two 4 2 x 15 mm truss head screws Tighten to secure For cabinet size 36 x 18 91 4 cm x 45 7 cm Attach the 36 x 18 91 4 cm x 45 7 cm face panel see the Assistance or Service section to order to the hood liner using four 3 5 x 9 5 mm flat head screws and two 4 2 x 15 mm truss head screws Tighten to secure Connect the lamp electrical connector 11 RANGE HOOD USE The range hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the center of the front of the range hood liner 7 a LI LZ Z A Blower and light controls B Grease filter CS 2
36. igner la base de l auvent avec le bas du placard Installer quatre vis de 4 2 x 19 mm dans les trous de la plaque de montage et serrer les 8 vis de montage 25 26 Pour certaines installations Une tringle d appui peut tre n cessaire pour certains placards Installer une tringle d appui et la fixer avec deux vis de 4 5 x 13 mm partir de l int rieur de la caisse de hotte A Vis 4 5 x 13 mm B Tringle d appui ter les filtres graisse m talliques du panneau avant Voir la section Entretien de la hotte Fixer le panneau avant la caisse de hotte 3 tailles la taille de placard illustr e correspond une dimension de 30 x 12 76 2 cm x 30 5 cm Voir les instructions donn es en fonction de la taille du placard de l utilisateur ci dessous i A A Vis t te plate de 3 5 x 9 5 mm 4 B Plaque avant illustration 30 x 12 76 2 cm x 30 5 C Placard illustration 30 x 12 76 2 cm x 30 5 D Vis t te bomb e de 4 2 x 15 mm 2 Pour taille de placard 30 x 12 76 2 cm x 30 5 cm Fixer le panneau avant de 30 x 12 76 2 cm x 30 5 cm fourni avec la hotte la caisse de la hotte l aide de quatre vis t te plate de 3 5 x 9 5 mm et deux vis t te bomb e de 4 2 x 15 mm Serrer pour fixer l ensemble
37. la liaison la terre r duit le risque de choc lectrique en permettant au courant de s chapper directement vers la terre La hotte est quip e d un cordon comportant un conducteur de liaison la terre avec fiche de liaison la terre La fiche doit tre branch e dans une prise correctement install e et reli e la terre AVERTISSEMENT Une mise la terre incorrecte peut entra ner un risque de choc lectrique Consulter un lectricien qualifi si les instructions de mise la terre ne sont pas compl tement comprises ou si vous avez des doutes quant la qualit de la liaison la terre de la hotte Ne pas utiliser de c ble de rallonge Si le cordon d alimentation lectrique est trop court faire installer une prise pr s de la hotte par un lectricien qualifi CONSERVEZ CES INSTRUCTIONS INSTRUCTIONS D INSTALLATION m 11 est recommand que l installation du circuit d vacuation soit r alis e avant celle de la hotte D charge l ext rieur travers le toit m Avant de proc der aux d coupages v rifier que les distances de s paration pour les raccords dans les cavit s du plafond ou du mur sont ad quates Relever les mesures appropri es et tracer les lignes indiqu es sur l illustration Utiliser une scie sauteuse ou une scie guichet pour d couper une ouverture travers le m Avant de monter le placard au mur il sera peut tre plus facile sommet du placard et le toit p
38. lers repair parts distributors and service companies Whirlpool designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the Whirlpool designated service company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Call the Whirlpool Canada LP Customer eXperience Centre toll free 1 800 807 6777 Our consultants provide assistance with m Features and specifications on our full line of appliances m Use and maintenance procedures m Accessory and repair parts sales Referrals to local dealers repair parts distributors and service companies Whirlpool Canada LP designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to Whirlpool Canada LP with any questions or concerns at Customer eXperience Centre Whirlpool Canada LP 200 6750 Century Ave Mississauga Ontario L5N 0B7 Please include a daytime phone number in your correspondence Recirculation Kit for non v
39. lled in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied serial number has been altered or removed from your major appliance The cost of repair or replacement under these excluded circumstances shall be borne by the customer DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE If outside the 50 United States and Canada contact your authorized Whirlpool dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use amp Care Guide After checking Troubleshooting you may find additional help by checki
40. loign e o un service d entretien Whirlpool autoris n est pas disponible 10 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instructions d installation fournies 11 Les gros appareils m nagers dont les num ros de s rie et de mod le originaux ont t enlev s modifi s ou qui ne peuvent pas tre facilement identifi s La pr sente garantie est nulle si le num ro de s rie d usine a t modifi ou enlev du gros appareil m nager Le co t d une r paration ou d un remplacement dans le cadre de ces circonstances exclues est la charge du client CLAUSE D EXON RATION DE RESPONSABILIT AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER SONT LIMIT ES UN AN O LA PLUS COURTE P RIODE AUTORIS E PAR LA LOI WHIRLPOOL N ASSUME AUCUNE RESPONSABILIT POUR LES DOMMAGES FORTUITS OU INDIRECTS CERTAINES JURIDICTIONS NE PERMETTENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES FORTUITS OU INDIRECTS OU LES LIMITATIONS DE LA DUREE DES GARANTIES IMPLICITES DE QUALITE MARCHANDE OU D APTITUDE A UN USAGE PARTICULIER DE SORTE QUE CES EXCLUSIONS OU LIMITATIONS PEUVENT NE PAS S APP
41. ltres eau Les pi ces consomptibles ne sont pas couvertes par la garantie 3 Les r parations lorsque le gros appareil m nager est utilis des fins autres que l usage unifamilial normal ou lorsque les instructions d installation et ou les instructions de l op rateur ou de l utilisateur fournies ne sont pas respect es 4 Les dommages imputables accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de pi ces consomptibles ou de produits nettoyants non approuv s par Whirlpool 5 Les d fauts apparents notamment les raflures les bosses fissures ou tout autre dommage au fini du gros appareil m nager moins que ces dommages soient dus des vices de mat riaux ou de fabrication et soient signal s Whirlpool dans les 30 jours suivant la date d achat 6 Toute perte d aliments due une d faillance du r frig rateur ou du cong lateur 7T Les co ts associ s au transport du gros appareil m nager du domicile pour r paration Ce gros appareil m nager est con u pour tre r par domicile et seul le service domicile est couvert par la pr sente garantie 8 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil 9 Les frais de transport pour le service d un produit si votre gros appareil est situ dans une r gion
42. n be 12 30 5 cm deep or 18 45 7 cm deep cabinets 36 91 4 cm cabinet width requires 18 45 7 cm deep cabinets For 18 45 7 cm deep cabinets an optional Face Panel Rear Extension 30 76 2 cm or Face Panel 36 91 4 cm must be purchased separately See Assistance and Service section to order m Vent system must terminate to the outside except for non vented recirculating installations m Donotterminate the vent system in an attic or other enclosed area Do not use a 4 10 2 cm laundry type wall cap Use metal vent only A rigid metal vent is recommended Plastic or metal foil vent is not recommended m The length of the vent system and number of elbows should be kept to a minimum to provide efficient performance For the most efficient and quiet operation m Use no more than three 90 elbows m Make sure there is a minimum of 24 61 0 cm of straight vent between the elbows if more than 1 elbow is used Do not install 2 elbows together The vent system must have a damper Use clamps to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold weather installations An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system The damper should be on the
43. n for 30 76 2 cm cabinet Bracket Orientation for 36 91 4 cm cabinet A Cabinet C Screws 4 2 x 19 mm 8 B Hood liner canopy assembly Spacer optional 2 If needed insert spacers between each side of the canopy and the mounting plate to space and center the canopy in the cabinet Align the bottom of the canopy with the bottom of the cabinet Install four 4 2 x 19 mm screws into the round mounting plate openings and tighten all 8 mounting screws 3 For some installations A filler strip may be required for some cabinets Install a filler strip and secure with two 4 5 x 13 mm screws from inside the front of the hood liner assembly A 36 91 4 cm cabinet B Screws 4 5 x 13 mm 6 C Washers optional D Mounting bracket 2 position for 36 91 4 cm cabinet 5 Install the vent system according to the method needed Use caulking to seal the exterior wall or roof opening A Screws 4 5 x 18 mm B Filler strip 10 4 Remove the metal grease filters from the face panel See the Range Hood Care section 5 Attach the face panel to the hood liner 3 sizes The 30 x 12 76 2 cm x 30 5 cm cabinet size is shown Vented Installations See instruction below for your specific cabinet size 1 Connect the vent system to the range hood vent opening Seal the connection with clamps Non Vented recirculating Installations 1 Conn
44. ng the Assistance or Service section or by calling Whirlpool In the U S A call 1 800 253 1301 In Canada call 1 800 807 6777 6 12 Keep this book and your sales slip together for future i Dealer reference You must provide proof of purchase or installation date for in warranty service Address Write down the following information about your major appliance to better help you obtain assistance or service if you ever need it Phone number You will need to know your complete model number and serial number You can find this information on the model and serial number label located on the product Model number Serial number Purchase date 16 S CURIT DE LA HOTTE DE CUISINI RE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves vous et d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DANG ER suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si v
45. ngueur du conduit de d charge et le nombre de coudes doivent tre r duits au minimum pour fournir la meilleure performance Pour un fonctionnement efficace et silencieux m Ne pas utiliser plus de trois coudes 90 m Veiller qu il y ait une section droite de conduit d un minimum de 24 61 cm entre les raccords coud s si on doit LT 2227 E I en utiliser plus d un v m Ne pas installer 2 coudes successifs A Hauteur minimale de placard 12 D Profondeur de placard de m Lecircuit d vacuation doit comporter un clapet anti reflux 30 5 cm 12 30 5 cm E p m Au niveau de chaque jointure du circuit d vacuation assurer B Largeur de l ouverture de placard E D gagement min entre le l h it les brides d 30 76 2 cm ou 36 91 4 cm haut du placard et le plan l tanch it avec les brides de serrage min de travail de 15 38 1 cm m l aide d un produit de calfeutrage assurer l tanch it C Distance sugg r e du bas du F Hauteur de placard sur autour de la bouche de d charge l ext rieur travers le placard la surface de cuisson 24 plancher de 36 91 4 cm mur ou le toit 9 61 cm min 36 91 4 cm max m La taille du conduit doit tre uniforme 20 Installations pour r gions climat froid On doit installer un clapet anti retour suppl mentaire l arri re pour minimiser le reflux d air froid et incorporer un
46. our l vacuation de d couper au pr alable l ouverture dans le fond du placard Te p Passer l tape 3 1 D connecter la source de courant lectrique 2 D terminer la m thode d vacuation utiliser d charge travers le mur ou le toit ou recyclage 3 Choisir une surface plane pour l assemblage de la hotte Placer le mat riau de protection sur cette surface AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re D Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure 4 l aide de deux personnes ou plus soulever la hotte et la poser sur la surface couverte A Ouverture 6 15 9 Ouverture d coup e du placard pour la hotte C 7 19 7 cm entre l axe central et l avant du placard D Axe central 1 Utiliser une scie sauteuse ou scie guichet pour d couper i une ouverture dans le fond du placard l int rieur du cadre REMARQUE Pour les placards d une hauteur de 12 du placard 30 5 cm une ouverture rectangulaire de 614 de profondeur x 8 de largeur 14 6 cm x 20 3 cm dans le sommet du placard est obligatoire pour tablir le d gagement n cessaire au raccord de transition du clapet anti reflux REMARQUE Pour les placards sans cadres un rebord avant et arri re de 34 1 9 cm est n cessaire pour former un cadre dans le fond du placard Une tringl
47. ous A AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions 17 18 IMPORTANTES INSTRUCTIONS DE S CURIT AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE CHOC LECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES m Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le fabricant m Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de verrouiller le tableau de disjoncteurs placer sur le tableau de disjoncteurs une tiquette d avertissement pro minente interdisant le r tablissement de l alimentation m Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies Ne pas faire fonctionner un ventilateur dont le cordon ou la fiche est endommag e Jeter le ventilateur ou le retourner un centre de service agr pour examen et ou r pa
48. ration m Une source d air de d bit suffisant est n cessaire pour le fonctionnement correct de tout appareil gaz combustion et vacuation des gaz combustion par la chemin e pour qu il n y ait pas de reflux des gaz de combustion Respecter les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Les ventilateurs d vacuation doivent toujours d charger l air l ext rieur MISE EN GARDE Cet appareil est congu uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives MISE EN GARDE Pour minimiser le risque d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS METALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN
49. rculating Installation Through the Soffit Cabinet in the Prepare Location section Recirculation Kit Part Number W10490330 is available from your dealer or an authorized parts distributor All openings in ceiling and wall where range hood will be installed must be sealed For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety title 24 HUD Part 280 or when such standard is not applicable the standard for Manufactured Home Installation 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 5014 or latest edition or with local codes Product Dimensions Cabinet Dimensions A 38 1 0 cm B 30 76 2 cm 36 91 4 cm C 26 66 1 cm lt gt gt ins A 12 30 5 cm min upper cabinet height B 30 76 2 cm or 36 91 4 cm cabinet opening width C 24 61 cm min 36 91 4 cm suggested max bottom of cabinet to cooking surface bo LT D 12 30 5 cm cabinet depth E 15 38 1 cm min clearance upper cabinet to countertop F 36 91 4 cm base cabinet height D 2 5 1 cm 5 12 7 cm E 1036 26 4 cm 1 9 cm G 112 30 2 cm 1776 45 4 H 976 23 1 cm 1 1356 33 7 NOTE 30 76 2 cm cabinet width ca
50. s Afin d viter d endommager la surface externe ne pas utiliser de tampons en laine d acier ou de tampons r curer savonneux Toujours essuyer pour viter de laisser des marques d eau M thode de nettoyage m Savon d tergent liquide et eau ou produit de nettoyage polyvalent m Frotter avec un chiffon doux humide ou une ponge non abrasive puis rincer avec de l eau propre et essuyer Filtre graisse m tallique Les filtres doivent tre lav s fr quemment Placer les filtres m talliques dans un lave vaisselle ou une solution de d tergent chaude Laisser s cher le filtre compl tement avant de le r installer teindre le ventilateur et les lampes Laisser refroidir la lampe halog ne 27 1 Retirer chaque filtre en tirant sur la poign e ressort puis en tirant le filtre vers le bas A Poign e ressort 2 Laver les filtres m talliques selon le besoin au lave vaisselle ou avec une solution de d tergent chaude 3 R installer le filtre en s assurant que les poign es ressort sont orient es vers l avant Ins rer le filtre graisse m tallique dans la rainure sup rieure 4 Tirer vers le bas la poign e ressort 5 Pousser le filtre m tallique vers le haut et rel cher la poign e pour l emboiter 6 R p ter les tapes 1 5 pour l autre filtre Filtres d installation sans d charge l ext rieur recyclage Le filtre charbon n est
51. s such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE m Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings m Always turn hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb m Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter m Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING m SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn
52. scie guichet pour d couper un trou de 534 14 6 cm pour le cache conduit 15 38 1 cm Une ouverture circulaire de 6 15 9 cm Installation dans de diam tre est n cessaire placard ou soffite 18 45 7 cm ou Une ouverture circulaire de 594 14 6 24 61 cm de diam tre est n cessaire Pour les installations sans d charge l ext rieur recyclage uniquement la hotte a t configur e peut tre install e avec d charge l int rieur du domicile travers le sommet du placard Pour une installation sans d charge l ext rieur recyclage l installation de filtres charbon est n cessaire Voir la section Entretien de la hotte pour des instructions sur l installation de filtres au charbon On doit utiliser l ensemble de recyclage pi ce num ro A Cache conduit W10490330 B Axe central 24 Achever la pr paration 3 S il n est pas encore fix installer le raccord de transition de 6 15 2 cm au sommet de la caisse de la hotte l aide de deux vis de 3 5 x 9 5 mm Rep rer l emplacement de la bride lat rale de montage en affleurement avec le bas de la paroi lat rale du placard et contre la face avant du placard Orienter la bride en fonction de la largeur du placard tel que d crit dans les sch mas ci dessous Percer des avant trous 3 mm en 6 points diff rents et fixer une bride l aide de trois vis de 4 5 x 13 mm de chaque c t du placard serrer
53. tes apr s l ach vement d une cuisson pour pouvoir vacuer de la cuisine toute trace d odeur de cuisson vapeur ou fum e Les commandes de la hotte sont situ es sur l avant centre de la caisse de hotte A Commandes du ventilateur et de l clairage B Filtre graisse C Poign e du filtre graisse D Logements des lampes halog ne 9909 A Bouton d clairage On Off marche arr t B Bouton de vitesse minimale et d arr t du ventilateur C Bouton de vitesse moyenne du ventilateur D Bouton de vitesse maximale du ventilateur Utilisation de la lampe Le bouton d clairage On Off contr le toutes les lampes Appuyer une fois pour On marche et une deuxi me fois pour Off arr t Utilisation du ventilateur Les boutons BLOWER SPEED vitesse du ventilateur activent le ventilateur et contr lent la vitesse du ventilateur et le niveau sonore pour un fonctionnement silencieux On peut modifier la vitesse tout moment pendant le fonctionnement du ventilateur en appuyant sur le bouton de vitesse du ventilateur souhait Appuyer une deuxi me fois sur le bouton BLOWER OFF arr t ventilateur pour teindre le ventilateur ENTRETIEN DE LA HOTTE IMPORTANT Nettoyer fr quemment la hotte et les filtres graisse en suivant les instructions suivantes R installer les filtres graisse avant de faire fonctionner la hotte Surfaces externe
54. tre ampoule si n cessaire 5 Reconnecter la source de courant lectrique SCH MAS DE C BLAGE Boutons poussoirs m chaniques 4 boutons 3 vitesses N BU BL WA NN BL Ch ssis du moteur FONCTIONNEMENT DU COMMUTATEUR FONCTION Vitesse basse Vitesse moyenne Vitesse lev e POSITION Pas de connexion MAR JA L 1 MAR BL L 2 MAR BU L 3 MAR N L 4 JA 12 5uF ros R sistance du moteur Ohms Caract ristiques BUIN du moteur BU GRIS ese Ru 240 W emp ambiante 734 F 23 c 1 29 ASSISTANCE OU SERVICE Lors d un appel pour assistance ou service veuillez conna tre la date d achat le num ro de mod le et le num ro de s rie complets de l appareil Ces renseignements nous aideront mieux r pondre votre demande Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d employer uniquement les pi ces sp cifi es par l usine Les pi ces sp cifi es par l usine conviendront et fonctionneront bien parce qu elles sont fabriqu es avec la m me pr cision utilis e dans la fabrication de chaque nouvel appareil Pour localiser les pi ces sp cifi es par l usine dans votre r gion nous appeler ou t l phoner au centre de service d sign le plus proche Veuillez
55. u avant pour placard de 36 x 18 91 4 cm x 45 7 cm Commander la pi ce num ro W10490310 GARANTIE DES GROS APPAREILS M NAGERS WHIRLPOOL CORPORATION GARANTIE LIMIT E Pendant un an compter de la date d achat lorsque ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit Whirlpool Corporation ou Whirlpool Canada LP ci apr s d sign es Whirlpool paiera pour les pi ces sp cifi es par l usine et la main d uvre pour corriger les vices de mat riaux ou de fabrication Le service doit tre fourni par une compagnie de service d sign e par Whirlpool Cette garantie limit e est valide uniquement aux tats Unis ou au Canada et s applique exclusivement lorsque l appareil est utilis dans le pays o il a t achet l ext rieur du Canada et des 50 tats des tats Unis cette garantie limit e ne s applique pas Une preuve de la date d achat original est exig e pour obtenir un service dans le cadre de la pr sente garantie limit e ARTICLES EXCLUS DE LA GARANTIE La pr sente garantie limit e ne couvre pas 1 Les visites de service pour rectifier l installation du gros appareil m nager montrer l utilisateur comment utiliser l appareil remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie du domicile 2 Les visites de service pour r parer ou remplacer les ampoules lectriques de l appareil les filtres air ou les fi
56. urrait provoquer une explosion de vapeur br lante m Utiliser un extincteur SEULEMENT si 1 s agit d un extincteur de classe ABC dont on connait le fonctionnement I s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA m AVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique ne pas utiliser ce ventilateur avec un quelconque dispositif de r glage de la vitesse semi conducteurs LIRE ET CONSERVER CES INSTRUCTIONS EXIGENCES D INSTALLATION Rassembler les outils et pi ces n cessaires avant d entreprendre l installation Lire et observer les instructions fournies avec chacun des outils de la liste ci dessous Outils n cessaires Niveau Perceuse Foret de 4 3 mm Crayon Pince M tre ruban ou r gle Pistolet calfeutrage et compos de calfeutrage r sistant aux intemp ries Tournevis Phillips Tournevis lame plate Scie sauteuse ou scie guichet Brides de conduit Cisaille de ferblantier Pi ces n cessaires m Syst me de conduit d vacuation m tallique rond de 6 15 2 cm Pour les installations avec d charge l ext rieur il faudra aussi m 1 bouche de d charge d charge travers le
57. vers le soffite A A B G C D D F E A Plafond F Placard B Cache conduit G Mur C Soffite H Hauteur du placard de 12 D vent de 6 15 2 cm 30 5 cm E Hotte de cuisini re 1 Hauteur de cache conduit de 17 43 2 cm REMARQUE Pour des placards de 12 30 5 cm de hauteur qui ne comportent pas de soffite le conduit et le cache conduit de 6 peuvent rester visibles AVERTISSEMENT Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique IMPORTANT La hotte doit tre correctement reli e la terre en conformit avec les codes et r glements locaux en vigueur ou en l absence de tels codes avec le National Electrical Code ANSI NFPA 70 derni re dition ou le Code canadien des installations lectriques CSA C22 1 No 0 M91 derni re dition Si les codes le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre 22 Pour obtenir un exemplaire des normes des codes ci dessus contacter National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 850
Download Pdf Manuals
Related Search
Related Contents
Samsung RH57H90507F Olympus T-10 Instruction Manual Samsung T200HD MotoSAT MD1000.2 User's Manual Arte manual de instrução Panela de Pressão BALDUINO Indoor Fogger Indoor Fogger Indoor Fogger3 1 Carson Specter Two Ryobi ZRRJ165VK Use and Care Manual Manual de Instrucciones JC 28 EVO HG 丁番・スライドヒンジ(PDF) Copyright © All rights reserved.
Failed to retrieve file