1. 1 Unplug the Power Cord and turn the Switch to the OFF position 2 Remove the Water Tank turn it upside down and unscrew the Valve Cap See Figure 6 Fill the Water Tank with cool water and replace the Valve Cap Do not use hot water To prolong the life of your steamer we recommend using distilled or de mineralized water Place the water tank back into the unit and make sure it is sitting properly and securely in the cavity Do not let the steamer operate with a dry water tank or the damage to the unit could occur Plug the unit into an outlet When you are finishing with your steaming session place the switch in the OFF position and unplug the unit Fo Figure 6 Figure 7 STEAMING YOUR GARMENTS 1 2 E ele To steam a garment place it on a clean rust free clothes hanger and place the hanger on the Clothes Hanger Hook Figure 1 Grasp the Handle and place the Steam Nozzle at the bottom of the garment Steam will rise along the inside and outside of the fabric removing wrinkles Slowly slide the nozzle vertically from the bottom to the top of the garment Do not allow kinks to form in the hose at any time Remove the nozzle from the garment and smooth the fabric with your free hand Repeat steps 2 and 3 as necessary until the fabric is wrinkle free Curtains and draperies can be steamed while still hanging Heavier fabrics may require repeated steaming To remove stubborn wrinkles the Fabric B
2. they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance 20 Care should be taken when using this device since it produces steam that can be extremely hot 21 The Laundry POD Upright Garment Steamer is designed for indoor use only and household use only Note To avoid danger of electric shock unplug from outlet when not in use and before cleaning If the power cord is damaged or your steamer does not work and needs to be repaired please contact StoreBound directly by phone at sie 1 800 898 6970 Monday Friday from 7am 7pm PST or by email at info storebound com TECHNICAL SPECIFICATIONS Model LP301UPS LP401UPS Water Tank Capacity 1 3L Startup Time 45 seconds Input Voltage 120V 60HZz Output Power 1500W COMPONENTS hi A Steam Nozzle Holder TA 1 B Clothes Hanger Hook Ny Telescopic Pole i Steam Nozzle Handle Hose j l l Clothes Rack Water Tank Water Reservoir Switch Holder 10 Drain Plug 11 Hose Base 12 Pole Base 13 Fabric Brush 14 Clothes Rack h OPNDNPA YN Figure 1 ASSEMBLY INSTRUCTIONS 1 Place the clothes hanger hook onto the top telescope pole A along the alignment as shown in Figure 2 below Insert the bottom of the telescope pole into the pole base as shown in Figure 3 below Turn the pole base lock clockwise until
3. ermittent Mineral build up in the unit It s normal for the unit to periodically stop steaming for a few seconds If the steam stays off for longer periods follow the Removing Mineral Build up procedure
4. ion into the Hose Connector If the water vinegar solution becomes visible in the Water Reservoir s inlet hole continue to pour the solution into the Hose Connector until the Water Reservoir is about half full near the top of hose 7 Let stand for 40 minutes 8 Drain the solution out of the Water Reservoir by removing the drain plug and allowing the liquid to drain into a sink or tub 9 Drain the solution out of the Hose Connector by tilting the unit over a sink or tub and pouring the water out of the Hose Connector 10 Pour clean water into the Hose Connector and Water Reservoir inlet and drain Repeat this step until the vinegar odor dissipates 11 Reassemble the unit and operate normally OND O Ol PROBLEM AND SOLUTIONS The unit fails to steam Steamer is not plugged in Plug into electrical outlet Indicating lamps do not illuminate Household Circuit Breaker Check the power outlet If you Ground Fault Interrupter is need assistance contact a tripped or Fuse is blown qualified electrician The unit fails to steam Mineral build up in the unit Follow the Removing Mineral Indicating lamps illuminate Build up The Water Tank is empty Refill the Water Tank Excessive gurgling of Hose and Condensation in hose Some gurgling is a natural Steam Nozzle effect of the steam process For excessive gurgling extend the hose vertically to allow water to drain back into the Water Reservoir Steam is int
5. rush may also be used Be careful when handling garments on the Clothes Hanger Hook Figure 1 Pulling on the garment with too much force may cause the unit to tip over 5 CLEANING AND STORAGE We recommend you follow this procedure at least once per week 1 Turn the Switch to OFF 2 Unplug the unit from the power outlet 3 Allow the steamer to cool for at least 30 minutes 4 Remove the Hose and shorten the Telescopic Pole then set aside 5 Remove and drain the Water Tank Rinse the water tank with fresh water and drain completely Place the Water Fill Tank back on the Water Reservoir 6 Drain the steamer by removing the Drain Plug and emptying the contents 7 Flush the unit by filling the Water Reservoir and the Hose Connector with fresh water and draining completely Replace the Drain Plug 8 Wrap the Hose around the Telescopic Pole one time Place the Steam Nozzle on the Steam Nozzle Holder 9 Store in a cool dry place REMOVING MINERAL BUILD UP The procedure below can be used to reduce mineral build up If you are unable to use demineralized or distilled water we recommend you follow this procedure monthly Turn the unit off and unplug the power cord Remove the Hose and Pole from the unit Drain the Water Reservoir and empty water from the Water Tank Mix a solution of 50 vinegar and 50 water In most cases 2 cups of this solution will be sufficient Slowly pour the water vinegar solut
6. t metal parts hot water or steam to avoid burns 10 Allow the appliance to cool completely for at least 30 minutes before draining the water tank and water reservoir before storage 11 To move the appliance do so by grasping the Telescopic Pole Figure 1 and lifting Turn off the unit drain the water tank and water reservoir 12 Always disconnect the appliance from the outlet before filling or draining water Be careful to avoid excess water spilling from the water reservoir 13 Unplug the unit from the outlet when not in use when moving unit from one location to another and before cleaning 14 Do not place the unit or any parts near an open flame cooking or other heating appliance 15 Do not operate the unit with a damaged cord with damaged plug after a malfunction or if dropped or damaged 16 To unplug the unit grip the plug and pull it from the wall outlet Never tug the cord to unplug the unit 17 Do not use extension cords with the Laundry POD Upright Steamer to avoid overheating and risk of fire 18 Do not add any detergent to the water tank Any detergent added will cause damage to the unit that is not covered by the limited warranty Using distilled or de mineralized water with the steamer is recommended as this will keep the unit functioning optimally 19 This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless
7. the laundry P D Upright Garment Steamer Instruction Manual MODEL LP301UPS MODEL LP401UPS Ve Nn f il Ni Please read all instructions carefully before using this machine Thank you for purchasing the Laundry POD Upright Garment Steamer Your new Garment Steamer is easy to operate and creates powerful continuous steam that eliminates wrinkles on clothes and reduces allergen causing dander and dust mites Please read this manual and keep it in a safe place for future reference IMPORTANT SAFETY INFORMATION When using this electrical appliance always follow basic safety precautions including the following 1 Read this instruction manual carefully to maximize this unit s performance 2 Do not operate another high wattage appliance in the same outlet or extension to avoid overloading the circuit 3 Use the appliance only as described in this manual Other uses not recommended may cause fire or electric shock 4 To protect against risk of electrical shock do not immerse the unit plug or cord in waiter 5 Do not leave the steamer unattended while it is in operation 6 Close supervision is necessary when the appliance is used near children Do not allow children to operate the unit by themselves 7 Do not operate the steamer without filling the water reservoir Always check the water level before and during operation 8 Do not lay the hose on the ground or wind it 9 Do not touch the ho
8. tightened Loosen the clips on the telescope pole Pull the whole pole to its full extension and tighten the clips as shown in Figure 2 below Put the Hose onto the threaded Hose Base by turning the fitting on the end of the Hose clockwise See Figure 3 Attention Only tighten by hand Do not over tighten 7 Hang the Steam Nozzle on the Steam Nozzle Holder as shown in Figure 4 below 3 os Ie D L G TE x j 1 7 i Figure 2 Figure 3 Figure 4 CAUTION 1 Always hang the Steam Nozzle on the Steam Nozzle Holder when not in use to prevent steam from causing bodily injury or damage to surfaces 2 The Telescopic Pole must be fully extended during steam operation to ensure that the hose hangs correctly and allows the steam to flow freely 3 Do not pull the hose with excessive force or damage will occur causing steam leakage Do not move the appliance by pulling the hose ACCESSORY ASSEMBLY The garment steamer comes with a Fabric Brush used for sweeping away unwanted threads lint and more FABRIC BRUSH ASSEMBLY 1 Turn off the steamer and wait until no steam emits from the Steam Nozzle 2 Assemble the flute of Fabric Brush towards the peg that at the bottom of Steam Nozzle see Figure 5 3 Push the Fabric Brush gently until it is firm in place Figure 5 CAUTION To avoid burns do not install the accessories while steam is emitting from the Steam Nozzle INSTRUCTIONS FOR USE