1. CONOMY RANGE HOOD INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A INTENDED FOR DOMESTIC COOKING ONLY WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufac turer lf you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at ser vice panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities When cutting or drilting into wall or ceiling do not damage electrical wiring and other hidden utilities To reduce the r
2. that filter slides under retaining tabs on back of fan housing Turn filter retainer so that arrows on retainer point toward front and back of hood 41000 Hoods Only The 41000 hood is equipped with a ductfree filter Re move filter by turning filter retainer to one side FIG 13 The ducttree filter is not washable and will last up to twelve months with normal use Replace the filter when colored side becomes noticeably dirty or discol ored When installing filter make sure that filter slides un der retaining tabs on back of fan housing MAKE SURE THAT COLORED SIDE OF FILTER IS NEXT TO FAN WHEN FILTER IS INSTALLED Turn filter retainer so that arrows on retainer point toward front and back of hood WARNING ALWAYS DISCONNECT ELECTRIC POWER BE FORE SERVICING RANGE HOOD FAN ASSEMBLY Remove filter Remove two screws holding motor bracket to range hood and unplug fan assembly Be careful not to allow fan assembly to drop when screws are removed FIG 14 CLEANING Clean your hood with a mild detergent suitable for painted surfaces DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS Fan assembly may be vacuumed Fan assembly is permanently lubricated and never needs oiling HOW TO AVOID A COMMON RANGE TOP GREASE FIRE Your range hood provides a protective barrier between the cooking surface and the cabinets Keep fan filters and grease laden surfaces CLEAN according to instructions Always turn hoo
3. 32 2 Soporte de montura del motor Motor incluye piezas 6 7 y 8 Filtro de aluminio Contenedor del filtro R tulo Negro R tulo Blanco interruptor del motor de 2 velocidades Negro incluye pieza 18 99020272 99260428 98005568 97012248 97006931 99420472 97010709 99090881 97016970 97016971 2 Speed Motor Switch White Includes Key No 18 Interruptor del motor de 2 velocidades Blanco incluye pieza18 97016970 Light Switch Black Includes Key No 17 Interruptor del foco Negro incluye pieza 17 97016971 Light Switch White Includes Key No 17 Interruptor del foco Blanco incluye pieza 17 97005678 Motor Receptacle with Wires Recipiente del motor con cableado 99150471 10 32 x 1 2 Green Ground Screw Tornillo de tierra verde 10 32 x 1 2 97010792 Light Bulb 75 Watt not included 7 Round Damper Model 42000D only Bulbo 75 watts no incluido Regulador de 7 pulg solamente Modelo 42000D Order service parts by PART NO NOT by KEY NO Encargue piezas de servicio por NO PIEZA NO por NO CODIGO Standard Hardware May be purchased locally Piezas est ndar Se pueden comprar localmente Not Illustrated No se muestran GARANTIA BROAN NUTONE LIMITADA POR UN A O Broan NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en m
4. El cableado salga por la salida del tap n FIG 10 Serie MX solamente Utilice el ojal reforzado provisto en bolso de las piezas b Las partes grandes de las ranuras se ajustan en los tornillos de la montura del extractor FIG 10 c El conector del ducto regulador se deslice dentro del ducto SOLAMENTE para extractores 40000 42000 y 42000D 3 Ajuste el extractor para que la parte del frente se nivele con el gabinete 4 Ajuste los tornillos de la montura del extractor con firmeza 5 Ajuste el cableado al extractor con el conector el ctrico adecuado para el tipo de cable que se va a utilizar ADVERTENCIA TODAS LAS CONEXIONES ELECTRICAS DEBEN SER REALIZADAS DE ACUERDO CON LOS CODI GOS LO CALES REGLAMENTOS Y CODIGOS ELECTRICOS NACIONALES SINO ESTA FAMILIAIZADO CON LOS METODOS DE INSTALACION DE CABLEADO ELECTRICO CONTRATE LOS SERVICIOS DE UN ELECTRICISTA CALIFICADO 6 Pele 1 2 plg de aislante de los cables Conecte los cables blanco con blanco negro con negro y el verde con el orificio hecho con el tornillo de tierra verde proporcionado en la bolsa FIG 11 7 Coloque de nuevo la tapa de la caja del cableado y el tornillo Aseg rese de que todo el cableado quede bien contenido en el interior 8 Instale el toco m ximo 75 watts Para lograr una instalaci n m s sencilla presione los protectores pl sticos y ret relos del extractor Recuerde reinstalar los protectores FIG 12 9 Conecte la corriente
5. PARED 639 3 1 4 x 10 DUCT 401 DUCTO DE 3 1 4 PLG x 10 PLG 401 ROOF CAP 634 CASQUETE DE TECHO 634 7 ROUND DUCT 407 DUCTO REDONDO DE 7 PLG 407 MODEL 87 DAMPER INCLUDED ON 42000D HOODS REGISTRO DE TIRO MODELO 87 INCLUIDO EN CAMPANAS DE 42000D ROOF CAP 634 CASQUETE DE TECHO 634 3 1 4 x 10 DUCT 401 DUCTO DE 3 1 4 PLG x 10 PLG 401 FIG E WALL CAP 641 CASQUETE DE PARED 641 ADJUSTABLE ELBOW 419 CODO AJUSTABLE 419 A 7 3 4 4 x 10 TO 6 ROUND DUCT TRANSITION 411 ADAPTADOR DE UNA SALIDA DE EXTRACTOR DE 3 1 4 PLG x 10 PLG A UN DUCTO CIRCU LAR DE 6 PLG 411 6 ROUND DUCT 406 DUCTO REDONDO DE 6 PLG 406 PRECAUCION A Para el uso de interior solamente 2 Solamente para uso general de ventilaci n No utilice para descargar materiales o vapores riesgosos o explosivos 3 Para evitar da os al motor y evitar que las navajas del abanico emitan mucho ruido o est n fuera de balance mantenga el motor libre de pelusa polvo etc 4 Para obtener mejores resultados en la captura de los vapores de la estufa el extractor debe montarse a entre 18 y 24 plg sobre las hornillas de la estufa 5 Por favor lea la etiqueta con las especificaciones del equipo para otros requisitos y mayor informaci n HERRAMIENTAS Y MATERI ALES QUE SE NECESITAN PARA LA INSTALACION Taladro el ctrico o clavador de trinquete Taladro de 1 8 plg Broca de 1 1 4 plg para taladrar un aguje
6. can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFP CAUTION 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 For best capture of cooking impurities your range hood should be mounted 18 24 above the cooking surface 5 Please read specification label on product for further information and requirements PON Pp y BRSOAN A _ A A E 40000 HOOD EXTRACTOR 40000 41000 amp 41000MX SERIES MI CROTEK SYSTEM SISTEMA I DE LA SERIE MICROTEK 41000 Y 41000MX 42000 amp 42000D HOODS EXTRACTOR 42000 Register your product online at www broan com register Registre su producto en l nea en www broan com register INSTALLER Leave This Manual With Homeowner HOMEOWNER Use and Care Information on Page 5 INSTALADOR Deje este manual con el due o de la casa DUENO DE LA CASA Informaci n acerca d el uso y los cuidados en la p gina 5 INSTRUCCIONES DE INSTALACION DE LOS EXTRACTORES TIPO ECO NOMICO LEA Y CONSERVE ESTAS INSTRUCCIONES dA PREVISTO PARA COCINAR DOM STICO SOLAMENTE ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE ELECTRICO O LESION A PERSONAS PROCURE LO SIGUIENTE 1 Utilice esta unidad
7. 000 Series Includes Key Nos 6 7 4 8 Motor Assembly 41000MX Series Includes Key Nos 6 7 amp 8 Ductfree Microtek Filter System Filter Retainer Nameplate Black Nameplate White 2 Speed Motor Switch Black Includes Key No 14 2 Speed Motor Switch White Includes Key No 14 Light Switch Black Includes Key No 13 Light Switch White Includes Key No 13 Motor Receptacle with Wires 3110 32 x 1 2 Green Ground Screw Grommet Light Bulb 75 Watt not included PIEZAS DE SERVICIO SISTEMA MICROTEK I SERIE 41000 Y 41000MX Las piezas de recambio se pueden ahora pedir en nuestro Web site Vis tenos por favor en www Broan com DESCRIPCION Cubierta de la caja de la toma de corriente Tomillos de meta para l mina 8 x 3 8 Contenedor del bulbo con cableado Cubierta protectora del foco Paquete de tomillos tuercas incluye 2 tornillos 10 16 x 0 500 y 2 tuercas de metal de l mina 10 16 Navajas del abanico Tuercas 6 32 2 Soporte de montura del motor Ensemblaje del motor Serie 41000 incluye piezas 6 7 y 8 Ensemblaje del motor Serie 41000MX incluye piezas 6 7 y 8 Sistema de filtro Ductfree Microtek System Contenedor de filtro R tulo Negro R tulo Blanco Interruptor del motor de 2 velocidades Negro incluye pieza18 Interruptor del motor de 2 velocidades Blanco incluye pieza18 Interruptor del foco Negro incluye pieza17 Interruptor del foco Blanco
8. A PARED O EL GABINETE ASEGURESE DE NO CORTAR EL CABLEADO ELECTRICO EXISTENTE Solamente para ta instalaci n en los gabinetes con espacios libres Coloque una pieza de madera en cada uno de los lados para rellenar el rea libre debajo del gabinete Utilice dos tiras de madera de 1 plg x 2 plg de longitud Si el rea libre tiene m s de 1 plg de profundidad utilice piezas de madera m s gruesas Ajuste las piezas con tornillos para madera de 1 1 4 pig a 3 pig de los extremos Consulte la FIG 4 Mida y marque lo siguiente FIGS 5A y 5B a La abertura del cableado el ctrico en la pared o el gabinete b La abertura para el ducto en la pared o el gabinete SOLAMENTE extractores modelos 40000 42000 y 42000D ADVERTENCIA Utilice un taladro de 1 1 4 plg para hacer la abertura para el cableado el ctrico Haga un corte en la pared o el gabinete para la entrada del ducto con un serrucho o una sierra de punta o de calador Si la pared es de concreto haga las operaciones necesarias para la instalaci n Centre el extractor en la entrada de la instalaci n y marque las ranuras en las piezas de madera que rellenan el espacio libre en la parte interior del gabinete Ajuste 4 tornillos para madera 10 x 7 8 justo en el centro del extremo angosto de las ranuras marcadas Permita que los tornillos salgan 3 8 pig para que el extractor pueda ser colocado en su lugar INSTALL THE DUCTWORK This section for 40000
9. EL UNICO Y EXCLUSIVO RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA BROAN NUTONE NO SERA RESPONSABLE POR DA OS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para calificar en la garantia de servicio usted debe a notificar a Broan NuTone al domicilio o al n mero de tel fono que se menciona abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe de presentar evidencia de la fecha original de compra Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 wWww broan com 800 558 1711 BROAN NUTONE ONE YEAR LIMITED WARRANTY Broan NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PART
10. ESCRIPTION Outlet Box Cover 8 x 3 8 Sheet Metal Screw Bulb Holder with Wires Light Lens Screw Nut Kit includes 2 10 16 x 500 screws and 2 10 16 sheet metat nuts Fan Blade 6 32 Locking Nuts 2 Required Motor Mounting Bracket Motor Assembly includes Key Nos 6 7 amp 8 Aluminum Filter Filter Retainer 8B x 1 4 Hex Head Sheet Metal Screws 2 Required Damper Flap Damper Bushing Damper Assembly includes Key Nos 13 14 and 21 Nameplate Black Nameplate White 2 Speed Motor Switch Black Includes Key No 18 2 Speed Motor Switch White Includes Key No 18 Light Switch Black Includes Key No 17 Light Switch White Includes Key No 17 Motor Receptacie with Wires 10 32 x 1 2 Green Ground Screw Damper Bumper Light Bulb 75 Watt not included Las piezas de recambio se pueden ahora pedir en nuestro Web site Vis tenos por favor en www Broan com COMO EVITAR QUE OCURRA UN INCENDIO DEBIDO A LA GRASA QUE SE ACUMULA EN UN EXTRACTOR COMUN Su extractor proporciona una barrera protectora en tre la superficie para cocinar y los gabinetes Mantenga el abanico los filtros y las superficies donde se acumula la grasa LIMPIAS conforme a las instrucciones ENCIENDA siempre el extractor cuando est cocinando a fuego alto para mantener el area para cocinar y el extractor limpios Utitice las hornilias de fuego alto solamente cuando sea necesario No deje las hornillas de la e
11. ICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND IN CANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONES OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty super
12. PARE THE HOOD 1 Unpack hood and check contents You should re ceive 1 Aluminum Filter 40000 and 42000 amp 42000D hoods only 1 3 1 4 x 10 Damper Duct Connector mounted inside of hood for shipping only 40000 hood only 1 Ductfree Microtek System Filter 41000 hood only 1 7 Round Damper 42000D hoods only 2 Remove wiring box cover Under cover find 1 Plastic Bag containing loose mounting hard ware 3 Remove top or rear electrical knockout FIG 2 4 40000 hood ONLY Remove duct knockout In sert screwdriver under edge of knockout break tabs and peel knockout back with pliers FIG 3 5 40000 hood ONLY Install damper duct connec tor over opening made in STEP 4 Use 8B sheet metal screws provided FIG 3 42000 hood ONLY Install Model 87 round damper purchase separately over opening in top of hood 42000D hood ONLY Install 7 round damper in cluded over opening on top of hood PREPARE THE INSTALLATION LOCATION Omit STEP 1 if hood will be installed under cabinets with flush bottom 1 For installation on recessed bottom cabinets only Attach a wood filter strip at each side of recessed area under cabinet Use two 1 x 2 strips cut to length If recess is deeper than 1 use thicker strips Attach strips with 1 1 4 wood screws 3 from each end of strip See FIG 4 2 Measure and mark the following FIGS 5A amp 5B a Electrical wiring opening in wall or cabine
13. Watt maximum For easier instal lation squeeze plastic lens and remove it from hood Remember to reinstall lens FIG 12 9 Turn on power and check operation of fan and light Make sure that damper operates freely e wi NU 10 15 16 FOR 24 RANGE HOOD 10 15 16 PLG PARA EXTRACTOR DE 24 PLG PIEZA DE 13 15 16 FOR 30 RANGE HOOD 13 15 16 PLG PARA EXTRACTOR DE 30 PLG 16 15 16 FOR 36 RANGE HOOD FILLER STRIP LINEA DE CENTROS HOOD WIDTH ANCHO DEL EXTRACTOR 40000 AND 41000 FIG 5B Xa i ZA MODELOS 40000 KEYHOLE SLOT OUTLINE CONTORNO DE LA RANURA LINEA DE CENTROS h s WALL CAP CASQUETE DE PARED CABINET GABINETE ROOF CAP CASQUETE DE TECHO DUCT T DUCTO SOFFIT PLAFON CABINET GABINETE f 16 15 16 PLG PARA EXTRACTOR DE 36 PLG 19 15 16 FOR 42 RANGE HOOD 19 15 16 PLG PARA EXTRACTOR DE 42 PLG INSTALACION DEL DUCTO Esta secci n es solamente para los extractores modelos 40000 y 42000 Los modelos 41000 pueden saltarse sta secci n y continuar en la INSTALACION DEL EXTRACTOR NOTA Estas instrucciones seguir n los planes descritos en la p g 2 Comience a trabajar del exterior al in terior para conectar el ducto con el extractor Para obtener un mejor funcionamiento del extrac tor procure que la salida del ducto sea la m s directa y
14. and 42000 hoods only 41000 hoods skip this section and go on to Install Range Hood NOTE These instructions will follow plans made on Page 2 Start at the exterior and run ductwork back to the range hood For best possible performance use the short est possible duct run and a minimum number of elbows Do not vent a range hood into an at tic space A buildup of grease in the attic could become a fire hazard Use only metal ductwork DO NOT USE PLAS TIC DUCT Assemble duct run securely so that in case of a grease fire on the range the fire will be contained inside metal ductwork Tape ali duct connections 1 Follow appropriate directions below tor type of duct run you install a Wall Cap Discharge FIG 7 Use saber saw or keyhole saw to cut hole slightly larger than duct size used so that duct will line up easily with damper duct conector on hood instail casing strips if cap will be installed on siding Attach required amount of duct to wall cap and run duct back to hood Fasten cap to wall and caulk well b Root Cap Discharge FIG 8 Cut a hole in roof slightly larger than duct size being used Run ductwork down to hood location Leave 3 4 of duct projecting above roof surface on high side Trim duct parallel to roof pitch and seal al around duct with roof cement Carefully trim shingles and slide back of roof sheet under shingles Nail roof sheet to roof un der shingles at top two corners and two si
15. ateriales o en mano de obra par un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS EXPLICITAS O IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio Broan NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso j LA PRESENTE GARANTIA NO CUBRE LOS TUBOS FLUORESCENTES NI SUS ARRANCADORES BOMBILLAS DE HALOGENO E INCANDESCENTES FUSIBLES FILTROS CONDUCTOS TAPONES DE TECHO O PAREDES Y DEM S ACCESORIOS PARA CONDUCTOS Esta garant a no cubre a mantenimiento y servicio normales o b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan causado un accidente o que hayan sido reparadas o mantenidas inapropladamente por otras compa as que no sean Broan NuTone instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un periodo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE BROAN NUTONE DEBERA SER
16. d ON when cooking at high heat to keep the cooking area and the hood cooler Use high heat settings oniy when necessary Never leave cooking surface unattended Boil over causes smoking and greasy spillovers that may ignite Always use adequate sized utensils If preparing flaming foods such as Cherries Ju bilee always turn hood ON to HIGH to prevent a high heat situation which can cause damage or fire HOW TO EXTINGUISH A COMMON RANGE TOP GREASE FIRE Never pick up a flaming pan if dropped flames can spread quickly DO NOT USE WATER A violent steam explo sion may result Wet dishcloths or towels are also dangerous Smother flames with a close fitting lid cookie sheet or metal tray Flaming grease can also be extinguished with baking soda or a multi purpose dry chemical extinguisher Turn off surface units if you can do so without getting burned FIG 9 MX Series Only GROMMET 7 e_ OJAL REFORZADO i ELECTRICAL KNOCKOUTS TAP NES EL CTRICOS Es GREEN GROUND SCREW TORNILLO DE TIERRA VERDE i As a A tl GROUND WIRE BARE Ol GREEN WIRE CABLE DE TIERRA CABLE 44 DESCUBIERTO O VERDE rer STAR LOCKNUT S TUERCA DE FIJACION DE ESTRELLA WHITE WIRES y GROUNDING BRACKET MENSULAS DE TIERRA LIGHT LENS LAMPARA SOCKET ENCHUFE FIG 13 FILTER RETAINER SOPORTE DEL FILTRO FILTER FILTRO TABS APENDICES 2 Coloque el extractor para que a
17. des Nail sheet directiy to roof in four places at bot tom Using roof cement seal all nail heads and shingles which were cut or lifted Do not seal bottom edge of roof sheet INSTALL RANGE HOOD WARNING TURN OFF THE PROPER CIRCUIT AT THE SER VICE ENTRANCE BEFORE WIRING THIS RANGE HOOD 1 Run electric wiring through hole drilled in wall or cabinet Split wiring for 6 and install proper con nector for type of wire used FIG 9 2 Position hood so that a Wiring is routed through knockout opening FIG 10 MX Series Only Use grommet sup plied in parts bag b Large part of keyhole slots fit over hood mount ing screws FIG 10 c Damper duct connector slides into ductwork 40000 42000 and 42000D hoods only 3 Adjust hood so that hood front is flush with cabi net frame 4 Tighten hood mounting screws firmly 5 Fasten wiring to hood with proper electrical con nector for type of wire being used WARNING ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL CODES ORDI NANCES OR NATIONAL ELECTRICAL CODE IF YOU ARE UNFAMILIAR WITH METHODS OF IN STALLING ELECTRICAL WIRING SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN 6 Strip 1 2 of insulation from wires Connect white to white black to black and green to prepared hole with green ground screw provided FIG 11 7 Replace wiring box cover and screw Make sure that all wiring is safely contained inside 8 Install tight 75
18. ebajo de los ap ndices en la parte trasera del compartimiento del abanico ASEGURESE DE QUE EL LADO COLOREADO DEL FILTRO QUEDE ENSEGUIDA DEL ABANICO CUANDO EL FILTRO SEA INSTALADO Gire el contenedor del filtro para que las flechas de el contenedor apunten hacia el frente y la parte trasera del extractor ADVERTENCIA DESCONECTE SIEMPRE EL CABLE DE ELEC TRICIDAD ANTES DE DARLE SERVICIO DE MANTENIMIENTO AL EXTRACTOR EL ENSAMBLE DEL ABANICO Retire el filtro Retire los dos tornillos que sostienen el motor en el extractor y desconecte el ensamble del abanico Aseg rese de no permitir que el abanico se caiga cuando retire los tornillos FIG 14 LA LIMPIEZA Limpie su extractor con un detergente suave que sea adecuado para superficies pintadas NO UTILICE PIEZAS DE TELA ABRASIVAS FIBRAS O DETERGENTE El abanico puede ser aspirado El ensamble del abanico est lubricado permanentamente y no necesita que se le agregue aceite Replacement parts can now be ordered on our website Please visit us at www Broan com 98006621 99170245 99270987 99110437 97011217 99020248 99260428 98005568 97012248 97006931 99420472 99150415 98005221 99100379 97005544 97010709 99090881 97016970 97016971 97016970 97016971 97005678 99150471 99100408 Order service parts by PART NO NOT by KEY NO Standard Hardware May be purchased locally Not Illustrated SCREWS TORNILLOS D
19. echo y selle alrededor del tubo con cemento para techos o tejados Empareje las tejas con cuidado y deslice la placa del tejado que est debajo de las tejas Clave la placa del tejado a la parte de techo que est bajo las tejas en las dos esquinas y los dos lados superiores Clave la placa directamente al tejado en cuatro extremos en la parte inferior Utilizando cemento para tejado selle todas las cabezas de los clavos y las tejas que fueron cortadas o levantadas No selle el extremo infe rior de la placa del tejado Si el techo es de concreto haga las operaciones necesarias para obtener los mismos resultados INSTALACION DEL EXTRACTOR ADVERTENCIA DESCONECTE EL CIRCUITO EN LA ENTRADA DE SERVICIO ANTES DE CONECTAR EL CABLEADO DEL EXTRACTOR b 1 Pase el cableado el ctrico a trav s de un orificio en la pared o el gabinete Separe el cableado a 6 plg e instale el conector apropiado para el tipo de cable usado FIG 9 USE AND CARE SWITCHES The fan and light are each controlled by a rocker switch The light switch has two positions ON and OFF The fan switch has three positions HIGH LOW and OFF OFF is the middle position FILTERS 40000 42000 42000D Hoods Only Remove aluminum filter by turning filter retainer to one side FIG 13 Filter should be washed once a month in a hot detergent solution Aluminum filters are dishwasher safe When installing filter make sure
20. ible duct run and a minimum number of elbows There are several choices shown FIGS A F below FIG A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is operating This could result in either inadequate air delivery or backdratts If this condi tion does exist remove the hood damper flap Sometimes when using a wali cap it is easier to duct vertically and then use an elbow as shown in FIG B In more complex ducting situations a 3 1 4 x 10 rec tangular ducting range hood 40000 hood can be con verted to a round duct by means of a transition FIG C Straight up through the roof using 7 round duct for single story installations 42000 42000D hood only FIG D Ducting straight up through the roof using 3 1 4 x 10 rectangular duct for single story installations 40000 hood only FIG E Ducting between the ceiling joists for multi story installations or through the soffit space above the cabinets where the soffit connects to an outside wall FIG F Straight up through the roof using 6 round duct for single story installations WALL CAP 639 CASQUETE DE PARED 639 WALL CAP 639 CASQUETE DE
21. ilustran dos formas para colocar el ducto a trav s de una pared externa Si se utiliza directamente un casquete de pared en la parte trasera del extractor debe ten erse especial cuidado para asegurarse de que el regulador en el conector del ducto regulador del extractor y el regulador en el casquete de la pared no se obstaculicen entre ellos cuando el extractor est en funcionamiento Esto puede dar como resultado que el aire tenga una salida inadecuada o que existan corrientes de aire invertidas Algunas veces es m s sencillo usar un casquete de pared coloc ndolo verti calmente y usando un codo como el mostrado en la FIG B Si la colocaci n del ducto es m s compleja el extractor del ducto rectangular de 3 1 4 pig x 10 plg puede substituirse por un ducto r dondo equivalente FIG C Utilizando un ducto circular de 7 plg en posici n vertical para instalaciones individuales solamente extrac tores modelo 42000 y 42000D FIG D Utilizando un ducto rectangular de 3 1 4 pig x 10 plg coloc ndolo en posici n vertical para instalaciones individuales solamente extractores modelo 40000 FIG E Coloc ndolo entre las vigas del techo para las instalaciones m ltiples o a trav s de un espacio de plaf n sobre los gabinetes en donde el plat n se conecta a una pared externa FIG F En posici n vertical a trav s del techo utilizando un ducto circular de 6 plg s lo para instalaciones individuales DUD O DOD g PRE
22. incluye pieza17 Recipiente del motor con cableado Tomillo de tierra verde 10 32 x 1 2 Ojal reforzado Bulbo 75 watts no incluido Encargue piezas de servicio por NO PIEZA NO por NO CODIGO Piezas est ndar Se pueden comprar localmente No se muestran SERVICE PARTS 21 PIEZAS DE SERVICIO 42000 amp 42000D 7 ROUND DUCTED HOODS 9 EXTRACTOR CON DUCTO CIR CULAR DE 7 PLG MODELOS 42000 Y 42000D Replacement parts can now be ordered on our website Las piezas de recambio se pueden ahora pedir en nuestro Web site Vis tenos por favor en www Broan com Please visit us at www Broan com Outlet Box Cover 48 18 x 3 8 Sheet Metal Screw Bulb Holder with Wires Light Lens Screw Nut Kit Includes 2 10 16 x 500 screws and 2 1410 16 sheet metal nuts Fan Blade 6 32 Locking Nuts 2 Required Motor Mounting Bracket Motor Assembly includes Key Nos 6 7 amp 8 Aluminum Filter Filter Retainer Nameplate Black Nameplate White 2 Speed Motor Switch Black Includes Key No 18 98006621 99170245 99270987 99110437 97011217 Cubierta de la caja de la toma de corriente Tornillos de metal para l mina 8 18 x 3 8 Contenedor del bulbo con cableado Cubierta protectora del foco Paquete de tornillos tuercas incluye 2 tornillos 10 16 x 0 500 y 2 tuercas de metal de l mina 10 16 Navajas del abanico Tuercas 6
23. isk of fire or electric shock do not use this range hood with an additional speed control device Ducted fans must always be vented to the outdoors To reduce the risk of fire use only metal ductwork Use with approved cord connection kit only 10 This unit must be grounded TO REDUCETHE RISK OF A RANGETOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCETHE RISK OF INJURYTO PERSONS INTHE EVENT OF A RANGETOP GREASE FIRE OBSERVETHE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immedi ately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICKUP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You
24. llos de metal de cabeza hexagonal 8B x 1 4 2 Protecci n del regulador Forro de metal del regulador Ensamblado de regulador incluye piezas 13 14 y 21 R tulo Negro R tulo Blanco Interruptor del motor de 2 velocidades Negro incluye pieza18 Interruptor del motor de 2 velocidades Blanco incluye pieza18 Interruptor del foco Negro incluye pieza17 Interruptor det foco Blanco incluye pieza17 Recipiente del motor con cableado Tomillo de tierra verde 10 32 x 1 2 Defensa del regulador Bulbo 75 watts no incluido Encargue piezas de servicio por NO PIEZA NO por NO CODIGO Piezas est ndar Se pueden comprar localmente No se muestran 6 SERVICE PARTS 41000 amp 41000MX SERIES MICROTEK SYSTEM Replacement parts can now be ordered on our website Please visit us at www Broan com 98006621 99170245 99270987 99110437 97011217 99020287 99260428 98005568 97011220 97016135 97007696 99420472 97010709 99090882 97016970 97016971 97016970 97016971 97005678 99150471 93400038 Order service parts by PART NO NOT by KEY NO Standard Hardware May be purchased locally Not lilustrated DESCRIPTION Outlet Box Cover 8 x 3 8 Sheet Metal Screw Bulb Holder with Wires Light Lens Screw Nut Kit Includes 2 10 16 x 500 screws and 2 10 16 sheet metal nuts Fan Blade 36 32 Locking Nuts 2 Required Motor Mounting Bracket Motor Assembly 41
25. para revisar la operaci n del abanico y la luz Aseg rese de que el regulador funcione con libertad USO Y CUIDADOS LOS INTERRUPTORES El abanico y el foco est n controlados individualmente por un interruptor balanc n El interruptor del foco tiene dos posiciones ENCENDIDO ON y APAGADO OFF El interruptor del abanico tiene tres posiciones ALTA HIGH BAJA LOW y APAGADO OFF El interruptor para APAGADO est en la posici n de en medio LOS FILTROS Solamente los extractores modelo 40000 42000 y 42000D Retire el filtro de aluminio girando el contenedor del filtro hacia un lado FIG 13 El filtro debe lavarse una vez al mes en una soluci n jabonosa caliente Los filtros de aluminio se pueden lavar en la lavadora de platos Cuando instale un filtro aseg rese de que el filtro se deslice debajo de los ap ndices en la parte trasera del compartimiento del abanico Gire el contenedor del filtro para que las flechas del contenedor apunten hacia el frente y la parte trasera del extractor Solamente los extractores modelo 41000 El extractor 41000 est equipado con un filtro sin ducto Retire el filtro girando el contenedor del filtro hacia un lado FIG 13 El filtro sin ducto no se puede lavar y durar hasta doce meses con un uso normal Coloque de nuevo el filtro cuando el lado de color se torne sucio o se decolore Cuando instale un filtro aseg rese de que el filtro se deslice por d
26. pre tener una salida hacia el exterior 8 Para reducir el riesgo de incendio use s lo ductos de metal 9 Uso con el kit aprobado del la conexi n de la cuerda solamente 10 Esta unidad se debe instalar con tierra efectiva PARA REDUCIR EL RIESGO DE INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS 1 Nunca deje sin atender las unidades de superficie cuando tengan ajustes altos Los reboses pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento de superficie PARA REDUCIR EL RIESGO DE LESION A PERSONAS RESULTADO DE UN INCENDIO DEBIDO A GRASA ACUMULADA EN LAS HORNILLAS PROCURE LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague ia hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVISE A LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar 3 NOUTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta 4 Utilice un extinguidor SOLAMENTE si A Usted
27. que tenga el menor n mero de codos No permita que la salida del extractor quede en un desv n Si se forma una capa de grasa en el desv n puede ser peligroso y causar un incendio Utilice solamente ductos de metal NO USE DUCTOS DE PLASTICO Ensamble el ducto firmemente para que en caso de que se prenda debido a la grasa el fuego se contenga dentro del ducto de metal Coloque cinta de aislar en todas las conexiones del ducto 1 Siga las incicaciones adecuadas para el tipo de ducto que vaya a instalar a Salida del casquete de pared FIG 7 Utilice un serrucho o una sierra de calador para cortar un orificio un poco m s grande que el tama o del ducto para poder acomodar facilmente el ducto con el conector del ducto regulador en el extractor Si el casquete se va a instalar en un lado instale las tiras del marco Fije la cantidad requerida del ducto en el casquete de pared y acomode el ducto en el extractor Ajuste el casquete a la pared Fijelo con un martillo Si la pared es de concreto u otro material ejecute las operaciones necesarias para obtener los mismos resultados Salida del casquete por el techo FIG 8 Haga un orificio en el techo ligeramente m s grande que la circunferencia del ducto que se est usando Coloque el ducto debajo del lugar donde va el extractor Deje que 3 4 plg del ducto sobresalgan por encima de la superficie en el lado alto del techo Ajuste el ducto paralelamente con la inclinaci n del t
28. r y revise el contenido de la caja Usted debe encontrar 1 Filtro de aluminio solamente extractores modelos 40000 42000 y 42000D 1 Conector de ducto reguiador de 3 1 4 plg x 10 pig montado dentro del extractor para facilitar el embarque solamente extractores modelo 40000 1 Sistema de filtro Ductfree Microtek System 1 Regulador de 7 pulg campanas de 42000D solamente Retire la cubierta de la caja de cableado FIG 1 Bajo la cubierta encontrar 1 Bolsa de pl stico que contiene las piezas necesarias para la instalaci n Retire el tap n el ctrico trasero superior Fig 2 SOLAMENTE extractores modelo 40000 Retire el tap n trasero superior Coloque un desarmador debajo del extremo del tap n rompa los ap ndices y retire el tap n con unas pinzas FIG 3 SOLAMENTE extractores modelo 40000 Instale el conector del ducto regulador sobre la abertura hecha en el PASO 4 Utilice el tornillo de l mina negra 8B proporcionado en la bolsa de pl stico FIG 3 SOLAMENTE extractores modelo 42000 Instale el regulador Modelo 87 comprado por separado sobre la abertura en la parte superior del extractor Campana de 4200D SOLAMENTE Instale regulador de 7 pulg incluido sobre la abertura en la tapa de la campana ACONDICIONE EL LUGAR DE LA INSTALACION Si el extractor va a ser instalado bajo gabinetes con suelo nivelado omita el PASO 1 1 CUANDO ESTE CORTANDO O PERFORANDO L
29. ro para la entrada de los cables el ctricos Una cuchilla recta y un desarmador con punta estrella phillips Pinzas Lap z y regla o una cinta de medir Serrucho de punta o serrucho para cortar pedazos de madera en 1 plg por 2 pig a la medida y para nacer las aberturas en las paredes o en los gabine es Remachadora pedazos de metal cinta para ductos ducto si es necesario con codos y conexiones y recubrimiento de pared o techo seg n sea necesario Cables el ctricos y materiales que sean aceptados por las leyes locales El siguiente material s lo se necesita s se va a instalar en la parte inferior de un gabinete de cocina Q Dos pedazos de madera con medidas aproximadas de 1 pig x 2 pig x 12 plg Q Cuatro tornillos para madera con cabeza plana de 1 1 4 plg PLANEANDO LA INSTALACION DE LOS DUCTOS Esta secci n es s lo para extractores modelos 40000 y 42000 Si su extractor es modelo 41000 s ltese esta secci n y contin e en la secci n de PREPARANDO EL EXTRACTOR Inicie el plan para instalar los ductos decidiendo por d nde va a pasar el ducto entre el extractor y la pared Para ob tener un mejor funcionamiento escoja la salida m s directa posible para el ducto y el menor n mero de codos Existen diferentes opciones que se muestran en las FIGURAS A a F enseguida FIG A Colocaci n directa a trav s de la pared para los extractores que est n montados en una pared externa Enseguida se
30. s lo en la manera prescrita por el fabricante Si tiene usted alguna pregunta comun quese con el fabricante a la direcci n o el tel fono indicados en la garant a 2 Antes de limpiar o de poner en servicio la unidad apague el interruptor en el panel de servicio y asegure el panel de servicio para evitar que se encienda accidentalmente Cuando el dispositivo para desconectar el servicio el ctrico no puede ser cerrado con alg n tipo de traba sujete fuertemente al panel de servicio una etiqueta de advertencia prominente 3 Todotrabajo de instalaci n y cableado el ctrico debe ser realizado por personal calificado y de acuerdo con todos los c digos y normas pertinentes incluyendo los c digos y normas relacionados con construcci n clasificada para incendio 4 Aire suficiente es necesario para facilitar la combusti n adecuada y la salida apropiada de gases por la chimenea de la unidad y para evitar corrientes de aire invertidas Siga las instrucciones y medidas de seguridad del fabricante del equipo y de las sociedades profesionales de equipos de calentadores y los reglamentos de seguridad locales 5 A cortar o perforar la pared o el techo no da e el cableado el ctrico u otros servicios p blicos ocultos a la vista 6 Para reducir el riesgo de incendio o de descarga el ctrica no utilice este ventilador con ning n dispositivo de una control de velocidad de estado s lido adicional 7 Los abanicos con ducto deber n siem
31. sabe que tiene un extinguidor de clase ABC y lo sabe utilizar B El incendio es peque o y contenido dentro del rea donde se inici Los bomberos han sido avisados D Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por la NFPA de los EEUU TOOLS AND MATERIALS REQUIRED O DODDO ODO m Drill electric or ratchet drive 1 8 Drill bit for drilling pilot holes 1 1 4 wood bit for drilling electrical wiring access hole One straight blade and one phillips head screwdriver Pliers Pencil and ruler and or tape measure Saber saw or keyhole saw for cutting 1 x 2 wood strips to length and cutting wall or cabinet openings Caulking metal snips duct tape duct with elbows and transition if necessary and roof or wall cap as required Electrical wiring and supplies of type to comply with local codes The following materials are required only for installations on recessed bottom kitchen cabinets o a Two 1 x 2 x 12 approximate length wood strips purchase locally Four 1 1 4 long flat head wood screws purchase locally PLANNING DUCTWORK INSTALLATION This section for 40000 and 42000 hoods only 41000 hoods skip this section and go on to Prepare the Hood Begin planning ductwork by deciding where the duct will run between the range hood and the outside For best performance use the shortest poss
32. sedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nature of any defect in the product or part t the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 W State Street Hartford Wisconsin 53027 www broa com 800 558 1711 99042381L
33. stufa sin atenci n cuando est cocinando El vapor o el aceite que salpique puede ocasionar un incendio o acumulaci n de humo Siempre utilice los utensilios del tama o adecuado Si est preparando alimentos flameados como las Cerezas a la Jubilee ENCIENDA siempre el ex tractor en ALTO para evitar que el calor pueda causar alg n da o o un incendio COMO EXTINGUIR UN INCENDIO EN UN EXTRAC TOR COMUN No levante nunca una sart n que est en llamas Si se le cae las llamas se pueden extender rapidamente NO UTILICE AGUA PARA APAGARLO Puede ocasionar una explosi n de vapor Las toallas de cocina mojadas tambi n son peligrosas Ahogue las llamas con una tapa ajustada o una charola e Las llamas provocadas por la grasa tambi n se pueden apagar con bicarbonato de sodio o un extinguidor qu mico Apague las hornillas si puede hacerlo sin quemarse SERVICE PARTS 40000 SERIES 3 1 4 X 10 DUCTED HOOD PIEZAS DE SERVICIO EXTRACTOR CON DUCTO DE 3 1 4 PLG X 10 PLG MODELO 40000 DESCRIPCION Cubierta de ta caja de la toma de corriente Tornillos de metal para l mina 8 x 3 8 Contenedor del bulbo con cableado Cubierta protectora del toco Paquete de tomillosftuercas incluye 2 tomillos 10 16 x 0 500 y 2 tuercas de metal de l mina i 10 16 Navajas del abanico Tuercas 6 32 2 Soporte de montura del motor Motor incluye piezas 6 7 y 8 Filtro de aluminio Contenedor del filtro Torni
34. t b Duct opening in wall or cabinet 40000 42000 amp 42000D hoods ONLY WARNING WHEN CUTTING OR DRILLING INTO WALL OR CABINET BE CAREFUL NOT TO CUT EXISTING ELECTRICAL WIRING 3 Use 1 1 4 bit to drill opening for electric wiring 4 Cut out duct opening in wall or cabinet with saber saw or keyhole saw 5 Center hood in installation opening and trace key hole slots onto wood filler strips on cabinet bottom 6 Screw four 10 x 7 8 wood screws into exact center of narrow end of traced keyhole slots Allow 3 8 of screws to project so that hood can be fitted into place later ROOF CAP 634 CASQUETE DE TECHO 634 6 ROUND DUCT 406 DUCTO REDONDO DE 6 PLG 406 3 1 4 x 10 TO 6 ROUND DUCT TRANSITION 411 ADAPTADOR DE UNA SALIDA DE EXTRACTOR DE 3 1 4 PLG x 10 PLG A UN DUCTO CIRCULAR DE 6 PLG 411 WIRING BOX COVER FIG 1 CUBIERTA DE LA CAJA DE CABLEADO DUCTFREE MICROTEKO SYSTEM FILTER 41000 HOOD ONL KEYHOLE SLOTS RANURAS DE FILTRO DUCTFREE MICROTEK SOLO PARA EL MODELO 41000 FILTER 40000 W 42000 amp 42000 DAMPER DUCT CONNECTOR 40000 HOOD ONLY CONECTOR DEL DUCTO REGULADOR SOLO PARA EL MODELO 40000 40000 42000 Y 42000D 7 ROUND DAMPER 42000D HOOD ONLY REGULADOR REDONDO DE 7 PULG SOLO PARA EL MODELO 420000 FIG 3 ELECTRICAL KNOCKOUTS TAPONES ELECTRICOS KNOCKOUTS TAPONES DEL DUCTO PREPARANDO EL EXTRACTOR 1 Desempaque el extracto
Download Pdf Manuals
Related Search
Related Contents
AM USB MANUAL Espanish PIX.cdr 取扱説明書 Operating Instructions - VEGAFLEX 81 User Manual - RayBiotech, Inc. le guide du tri Salicru SLC-3000-TWIN PRO uninterruptible power supply (UPS) User Guide - ASVIC Engineering Software Avaya 1400 Series Digital Deskphones Application Note Copyright © All rights reserved.