ResortLock RL4000N-S Instructions / Assembly
Contents
1. 2 To change Master Code and delete all user codes _ current or default mc 22 1 9digitnew me 1 9digitnewme 3 Set date amp time 24 hr clock Example 2 45PM on July 12 2010 1007121445 _ me 88 yymmddhhmm 4 Enter one or more User Code with no restriction mc 01 5 Enter one or more iButton key with no restriction mc 01 6 Enter one or more iButton key User Code with no restriction mc 01 7 Enter one or more User Code with time restriction for multiple users repeat highlighted beginning time ending time 8 Enter one or more iButton key with time restriction beginning time ending time mc 01 9 Enter one or multiple iButton User Codes with time restriction for multiple repeat highlighted beginning time ending time mc 01 10 Enable Passage Mode 1 Monday 7 Sunday 1 7 Schedule hhmm start mc 15 hhmmend 11 Disable Passage Mode 12 Enable disable LED blink 2 beeps blink off 4 beeps blink on me 18 Warning enabling blink mode will drain batteries more quickly Lock will blink red when locked green when unlocked 13 Enable Daylight Saving Time Lock time does not change when you enable this function The time will change according to the U S Daylight Saving Time schedule 14 Disable Daylight Saving Time 1
2. uJ oan Le Installation amp User Manual For use with ResortLock RL4000 and LockState LS 1500 ResortLOGk Insert latch into the door latch hole Secure the latch with two Major Lock Parts List N VERQY AQ 5 a a a aa 2 3 4 5 6 7 8 9 10 11 2 1 Inside Lever 2 Battery Housing Cover 3 Inside Back Lock Housing 7 Spindle 8 Outside Front Gasket 9 Outside Front Lock Housing 4 Inside Back Mounting Plate 10 iButton Reader 5 Inside Gasket 11 Key Override Cylinder 6 Latch 12 Outside Lever Installation Instructions Step 1 Step 2 Step 3 Step 4 Drill the 3 8 upper Place the front Insert the square support hole into side rubber gasket spindle into the the door 3 5 16 if required onthe center hub above the center back of the front Ensure dot is of boring hole lock housing pointed left Ain k Pi hi i j 5 gt T i baits Pp 14 a A y WA i PR see il i y f i Nag se AN Step 5 Fit the front lock housing onto the front of the door Feed the power plug through the 2 1 8 boring hole d HR e F f it y Y i E A t pe fi q j Bab tn i gt t A a y HE eis r b oe a 5 or A ie Ps ATR A Pr nM is s yS f a7 ed 4Y E AT j 7 FAV te 1 f Step Hold the inside lock housing up to the inside of door Plug the front lock power cable into the connector Step 10 Secure the inside lock
3. 5 Add One Time Service codes up to 10 16 Delete one User Code or iButton user me 46 17 Enable Auto UNlock function 64 18 Disable Auto UNlock function 19 Set Automatic Unlock time Enable function 17 first 20 Enable Auto Lock function 67 21 Disable Auto Lock function 22 Set Automatic Lock time Enable function 20 first 23 Enable Disable temporary lockout of all users me 99 Advanced Schedule Access for multiple users repeat highlighted 24 Set schedule for User Code _ 1 Monday 7 Sunday _ For Example to set schedule from 8 00AM to 5 0 A User Code or iButton must be programmed before Advanced Schedule Access can be applied
4. e User code User Codes are the normal codes for day to day operation Service Code Service codes can be used for maintenance personnel or vendors Service codes only grant one time access A total of 10 sets of service codes can be programmed into each lock Passage Mode When Passage Mode is enabled the lock will stay in an unlocked status after a valid entry code is entered Enter a valid entry code to re lock the door Storehouse Mode For each valid entry the lock will automatically re lock after 5 seconds Time Format 24 hr clock 8 30AM 0830 5 30PM 1730 Schedule Date 1 Mon 2 Tue 7 Sun Quick Start Guide Step 1 Program a new Master Code into the lock The Master Code DOES NOT unlock or lock the door It is only used to program your lock The default Master Code is 123456 For security purposes you will need to change this to your own Master Code Decide on a new Master Code and write it here To program a new Master Code enter the following into the lock s keypad 123456 11 Your Master Code Your Master Code Again If done correctly after the last you press you ll hear 2 beeps with 2 green flashes Step 2 Program the Date amp Time Some functions on the lock will not work on the lock unless the date amp time are programmed To program the date amp time enter the following Master Code 88 YYMMDDHHMM Example If the date and time is 05 30 2010 at 3 32PM you would enter Master C
5. housing battery cover with two screws a f i Fi F TY 1 i 4 i i T Epis Wha P ia yay yy Bi E SONATE Vi a in 2 A t J We t 1 Boye PO Oe Sap ae mn N as Step 6 Place the inside gasket on the inside plate Feed power plug through and secure to door amp front lock with screw P i 7 t EED tr i P Aerie q IA AS i i Soa Step 8 Step 9 Place inside lock over Insert 4 AA batteries mounting place amp secure with screws into the battery compartment tg SN Step 11 Slide the inside lever into place Press firmly until handle snaps over catch pins Front Handle amp Key Installation 1 Ensure that the key override slot 2 Slide the key cylinder into the is in the horrizontal position back of the handle 4 Slide the handle onto the drive shaft until it hits the catch pins 3 Insert the key into the key cylin der from the front of the handle 5 Push the key in as far as it will go and then turn 90 degrees clockwise 6 Firmly press the lever until it snaps over the catch pins Turn the key back to the left and remove Lock Operation Guide General Information e Door Handle The handle is reversible so it will fit both right and left handed doors The handle will always turn even when the door is locked However when locked the exterior handle will not retract the latch The interior handle will always retract the latch e Exit Programming Mode E
6. nter to exit programming mode or wait for 10 seconds e Low battery warning When batteries are low the red LED will flash and beep five times after entering a valid User Code e Unlocking indicator Green light will flash and beep twice e Locking indicator No light and will beep twice e Reset To reset the lock back to factory default settings press and hold the reset button for 10 seconds until the light on the front of the lock starts flashing green Release the reset button and press the key to confirm You will receive 3 beeps if successful Manufacture Default Setting e Daylight Saving Mode Disabled e Auto Lock Unlock Disabled e Lock Mode Storehouse e Default Programming Master Code 123456 e Test Code 0 Unlocking the Door There are several ways to unlock the lock including the following methods e Keycode Enter a User Code then press iButton Touch the iButton key to the lock reader iButton Keycode Touch the iButton key to the lock reader then enter User Code and press One time service code Enter one time code then press Manual key Insert and turn the override key 90 degrees clockwise then turn the handle Terms Master Code MC The master code enters the lock into programming mode It will not lock or unlock the lock the door If more than 6 seconds pass in between programming entries the lock will return to normal operational status For maximum security change the default Master Cod
7. ode 88 1005301532 Step 3 Program a User Code into the lock Important Your lock will not lock until a valid User Code is programmed and used on the lock User Codes are the codes you will use to unlock and lock your door These codes will remain active in the lock until they are deleted if desired Up to 800 permanent codes can be programmed into the lock Here is how Master Code 01 1 9 digit user code If done correctly you will hear two beeps after pressing the 3 then a red light after the 4 Step 4 Set the Passage Mode Optional Your lock is shipped in Storehouse Mode This means the lock will re lock 5 seconds after it is unlocked To change this to passage mode enter the following Master Code 15 1 7 Schedule hhmm start hhmm end Example If you want the lock to always be in Passage Mode enter Master Code 15 1234567 0001 2359 7 days of the week from 12 01AM to 11 59PM Step 5 Enable Daylight Saving Time If you live in an area that observes Daylight Saving Time you will want to enable this function Enabling does not change the current time on the lock The time wil change according to the U S Daylight Saving Time schedule To enable enter Master Code 31 Complete List of Manual Programming Functions 1 To set anew or change the Master Code and not delete existing user codes _ current or default mc 11 1 9digitnewme 1 9digitnewme