Home

Grace 5003093 Installation Guide

image

Contents

1. e Easy to handle and apply The self adhesive membrane bonds firmly to the roof deck without heat or special adhesives RIPCORD is a unique patented feature that makes Grace Ice amp Water Shield easier to apply by giving the applicator a split release on demand Faster application of the membrane in the straight aways as well as ease of membrane positioning in detailed areas valleys around dormers etc are just some of the benefits Foldless release paper The foldless release paper provides multiple performance enhancements fewer edge catches 180 pull back ease of membrane cutting single cuts and membrane positioning quicker one man installs resulting in an easier more productive release Seals around nails The rubberised asphalt layer in Grace Ice amp Water Shield seals around roofing nails resisting leakage caused by water back up behind ice dams or from wind driven rain Dual barrier protection Rubberised asphalt and polyethylene are combined to form two waterproofing barriers providing maximum protection Membrane will not crack dry out or rot Grace Ice amp Water Shield resists attacks from fungus and bacteria maintains its integrity for long lasting protection Physical Properties Property Typical Values Test Method Colour Grey Black Nominal Thickness 1mm ASTM D 3767 Method A Tensile Strength Membrane 2N mm ASTM D 412 Die C Modified El
2. fall protection when working on a roof deck Release liners are slippery Remove from work area immediately after membrane application Do not leave permanently exposed to sunlight Cover within 30 days Place metal drip edges or wood starter shingles over the membrane Do not fold over the roof edge unless the edge is protected by a drip edge gutter or other flashing material Do not install on the chamfered edges of wood plank Do not install directly on old roof coverings Certain product applications are prohibited in hot desert areas Check with your Grace Construction Products representative Check with the manufacturer of the metal roofing system for any special requirements when used under metal roofing Do not install directly under roof coverings especially sensitive to corrosion such as zinc without providing proper ventilation Do not install under copper Cor Ten or zinc metal roofing in high altitudes These roofs can reach extremely high temperatures due to the low reflectivity high absorption and high conductivity of the metals Use Grace Ultra for these roof types Check with your Grace Construction Products representative Provide proper roof insulation and ventilation to help reduce ice dams and to minimise condensation Grace Ice amp Water Shield is an air and vapour barrier Repair holes fishmouths tears and damage to membrane with a round patch of membrane extending past the damaged area 150 mm
3. conditions of use are beyond our control we do not warrant the results to be obtained Please read all statements recommendations or suggestions in conjunction with our conditions of sale including those limiting warranties and remedies which apply to all goods supplied by us No statement recommendation or suggestion is intended for any use which would violate or infringe statutory obligations or any rights belonging to a third party These products may be covered by patents or patents pending Copyright 2014 Grace Australia Pty Ltd 121 GIWS 1D Printed in Australia 02 14 GRACE
4. in all directions If fasteners are removed leaving holes in the membrane they must be patched The membrane may not self seal open fastener penetrations Do not install fasteners through the membrane over unsupported areas of the structural deck such as over the joints between adjacent structural panels Due to its slight asphaltic odor do not apply where the membrane is exposed to interior living space Refer to product literature for more complete information Not compatible with EPDM or TPO use Grace Ultra for tie ins refer to Technical Letter 5 Chemical Compatibility Not compatible with polysulfides flexible PVC or high concentrations of resin pitch For more information refer to Technical Letter 5 Code Compliance Grace Ice amp Water Shield meets the following standards Underwriters Laboratories Inc Class A fire classification under fiber glass shingles and Class C under organic felt shingles per ASTM E108 UL 790 Underwriters Laboratories Inc Classified Sheathing Material Fire Resistance Classification with Roof Designs P225 P227 P230 P237 P259 P508 P510 P512 P514 P701 P711 P717 P722 P723 P732 P734 P736 P742 P803 P814 P818 P824 Miami Dade County Code Report NOA 09 0107 08 Canadian Construction Materials Centre CCMC 12693 R U S Department of Housing and Urban Development HUD Materials Release 1068g City of Los Angeles RR 25330 Florida State Approval Report No FL298 R3 In
5. Grace Waterproofing Systems Grace Ice amp Water Shield Self adhered underlayment for premium protection Grace Ice amp Water Shield has been the premier self adhesive underlayment product used in domestic roof protection under shingles for more than 30 years It has performed in the critical areas under the most severe climatic conditions to protect against wind driven rain and the effects of ice dam build up beneath the shingles Because of the unique properties of Grace Ice amp Water Shield these benefits are also applicable in its use under a wide range of metal roofing materials on low and high slope designs Advantages Easy to handle and apply Foldless release paper e Seals around nails Dual barrier protection Membrane will not crack dry out or rot e Protects under all standard sloped roof coverings Slip resistant surface Proven track record e Reroofable e Grace technical support Product Description Grace Ice amp Water Shield membrane is composed of two waterproofing materials an aggressive rubberised asphalt adhesive backed by a layer of high density cross laminated polyethylene The rubberised asphalt surface is backed with a release paper that protects the adhesive quality During application the release paper is removed allowing the compound to bond tightly to the plywood deck The membrane is supplied in 20 metre rolls 1 metre in width Features amp Benefits
6. king Grace technical support Grace Ice amp Water Shield is backed by a team of local technical support personnel that help ensure every application goes smoothly Installation Procedure Surface Preparation Install Grace Ice amp Water Shield directly on a clean dry continuous structural deck Some suitable deck materials include plywood wood composition wood plank metal concrete or gypsum sheathing Remove dust dirt loose nails and old roofing materials Protrusions from the deck area must be removed Decks shall have no voids damaged or unsupported areas Wood planks should be closely butted together Repair deck areas before installing the membrane Prime concrete masonry surfaces and DensGlass Gold with Perm A Barrier WB Primer Prime wood composition and gypsum sheathing with Perm A Barrier WB Primer if adhesion is found to be marginal refer to Technical Letter 12 Use on Oriented Strand Board OSB Roof Sheathing Apply Perm A Barrier WB Primer at a rate of 6 8 m L Priming is not required for other suitable surfaces provided that they are clean and dry Membrane Installation Apply Grace Ice amp Water Shield in fair weather when the air roof deck and membrane are at temperatures of 5 C or higher Apply roof covering material at temperatures of 5 C or higher Cut the membrane into 3 5 m lengths and reroll loosely Peel back 300 600 mm of release liner align the membrane and continue t
7. o peel the release liner from the membrane Press the membrane in place with heavy hand pressure Side laps must be a minimum of 90 mm and end laps a minimum of 150 mm For valley and ridge application peel the release liner center the sheet over the valley or ridge drape and press it in place Work from the center of the valley or ridge outward in each direction and start at the low point and work up the roof Alternatively starting with a full roll of membrane unroll a 1 2 m piece of membrane leaving the release liner in place Align the membrane and roll in the intended direction of membrane application Carefully cut the release liner on top of the roll in the cross direction being careful not to cut the membrane Peel back about 150 mm of the release liner in the opposite direction of the intended membrane application exposing the black adhesive Hold the release liner with one hand and pull the roll along the deck with the release liner leaving the applied membrane behind Use the other hand to apply pressure on the top of the roll Stop frequently to press the membrane in place with heavy hand pressure When finished with the roll go back to the beginning reroll and pull the remaining release paper from the material finishing the installation For successive membrane courses align the edge of the release liner with the dashed line provided on the surface of the membrane to achieve the 90 mm side lap Consistent with good ro
8. ofing practice install the membrane such that all laps shed water Always work from the low point to the high point of the roof Apply the membrane in valleys before the membrane is applied to the eaves Following placement along the eaves continue application of the membrane up the roof The membrane may be installed either vertically or horizontally Use smooth shank electro plated galvanised nails for fastening shingles to get the best seal Hand nailing generally provides a better seal than power activated nailing If nailing of the membrane is necessary on steep slopes during hot or extreme cold weather backnail and cover the nails by overlapping with the next sheet Extend the membrane on the roof deck above the highest expected level of water back up from ice dams and above the highest expected level of snow and ice on the wall sheathing on vertical side walls dormers and vertical front walls for ice dam protection Consider a double layer of membrane in critical areas such as along the eaves or in valleys and in climates where severe ice dams are anticipated Apply the membrane to the entire roof deck for wind driven rain protection Apply a new layer of Grace Ice amp Water Shield directly over the old Grace underlayment in retrofit applications following the standard membrane application procedure Precautions amp Limitations Slippery when wet or covered by frost Consistent with good roofing practice always wear
9. ongation Break of Membrane 200 ASTM D 412 Die C Modified Low Temperature Flexibility Unaffected 29 C ASTM D 1970 Adhesion to Plywood 525 N m ASTM D 903 Permeance 2 5 ng m s Pa 0 08 Perms ASTM E 96 Nominal thickness refers to the thickness of the membrane without release liner Typical test values may represent average values from samples tested Test methods noted may be modified The test is run at a rate of 50 mm per minute Protects under all standard sloped roof coverings Grace Ice amp Water Shield protects under slate tile cedar shakes or metal as well as under conventional asphalt shingles Slip resistant surface Grace Ice amp Water Shield has a slip resistant embossed surface to maximise traction and safety for applicators Proven track record Grace Ice amp Water Shield is the name brand in roofing underlayments with a 30 year track record of protecting roofs from ice dams and wind driven rain Reroofable Unlike some granular surfaced membranes Grace Ice amp Water Shield will not adhere to the underside of the exposed roof covering Grace Ice amp Water Shield can be applied over the old Grace underlayment except over Grace Basik in retrofit applications making reroofing easier less costly since there is no need for removing the existing underlayment more durable and environmentally friendly as the structural deck remains intact avoiding the need to purchase additional wood dec
10. ternational Code Council Evaluation Services ICC ES Report No ESR 1677 Supply Quality Assurance Pack Size 1m x 20m roll 20 sqm Gross Weight 26 kg Storage Dry conditions below 35 C W R Grace Singapore Pte Ltd is certified to ISO9001 Quality Systems by the Singapore Productivity and Standards Board for the manufacture of Bituthene Waterproofing Membranes under the registered certification number ISO 93 2 Health and Safety 0268 Refer to relevant Material Safety Data Sheet Grace Technical Services For assistance with working drawings for projects and additional technical advice please contact Grace Technical Services www graceconstruction com Australia 1800 855 525 New Zealand 64 9 448 1146 China Mainland 86 21 5467 4678 Hong Kong 852 2675 7898 Indonesia 62 21 893 4260 Japan 81 3 3537 6366 Korea 82 32 820 0800 Malaysia 60 3 9074 6133 Philippines 63 49 549 7373 Singapore 65 6265 3033 Taiwan 886 3 427 0850 Thailand 66 2 709 4470 Vietnam 84 8 3710 6168 Grace Ice amp Water Shield Tri Flex 30 Basik Perm A Barrier and Ripcord are registered trademarks of W R Grace amp Co Conn Cor Ten is a registered trademark assigned to USX DenGlass Gold is a registered trademark of Georgia Pacific Corporation The information given is based on data and knowledge considered to be true and accurate and is offered for the user s consideration investigation and verification Since the