Home

ZyXEL GS1100-16 User's Manual

image

Contents

1. Four M5 flat head screws and a 2 Philips screwdriver Failure to use the proper screws may damage the unit Precautions Make sure the rack will safely support the combined weight of all the equipment it contains Make sure the position of the Switch does not make the rack unstable or top heavy Take all necessary precautions to anchor the rack securely before installing the unit GS1100 Series User s Guide Chapter 2 Hardware Description and Connection Attaching the Mounting Brackets to the Switch 1 Position a mounting bracket on one side of the Switch lining up the four screw holes on the bracket with the screw holes on the side of the Switch Figure 11 Attaching the Mounting Brackets GS1100 16 2 Using a 2 Philips screwdriver install the M3 flat head screws through the mounting bracket holes into the Switch 3 Repeat steps 1 and 2 to install the second mounting bracket on the other side of the Switch 4 You may now mount the Switch on a rack Proceed to the next section GS1100 Series User s Guide Chapter 2 Hardware Description and Connection 2 3 3 Mounting the Switch on a Rack 1 Position a mounting bracket that is already attached to the Switch on one side of the rack lining up the two screw holes on the bracket with the screw holes on the side of the rack Figure 13 Mounting the Switch on a Rack GS1100 16 GS1100 Series User s Guide Chapter 2 Hardware Description and Conn
2. These are the product specifications Table 3 Product Specifications Dimension GS1100 16 215 mm W x 133 mm D x 42 mm H GS1100 24 441 mm W x 131 mm D x 44 mm H Weight GS1100 16 1 kg GS1100 24 2 kg Standard IEEE802 3 10 BASE T I EEE802 3u 100 BASE TX IEEE802 3ab 1000 BASE T IEEE802 3x full duplex flow control IEEE802 3az EEE IEEE802 3z 1000 BASE X GS1100 24 only Interface GS1100 16 16 x 10 100 1000 Mbps auto MDI MDI X RJ 45 switching ports GS1100 24 24 x 10 100 1000 Mbps auto MDI MDI X RJ 45 switching ports 2 x Mini GBIC open slots Cable connections RJ 45 10 BASE T Category 3 4 5 UTP STP RJ 45 100 BASE TX Category 5 UTP STP RJ 45 1000 BASE T Category 5e 6 or enhanced UTP STP Network Data Rate 10 100 1000 Mbps Auto negotiation Transmission Mode 10 100 Mbps Full duplex Half duplex 1000 Mbps Full duplex Data Forwarding Rate 14880 pps for 10 Base T 148800 pps for 100 Base Tx 1488000 pps for 1000 Base T LED Indications System PWR Ports LINK ACT Memory GS1100 16 8K MAC entries 256 K bytes buffer Memory GS1100 24 8K MAC entries 448 K bytes buffer Memory GS1100 Series User s Guide Chapter 4 Product Specifications Table 3 Product Specifications Jumbo Frame 9K bytes Operating 0 50 C Temperature Storage 40 70 C Temperature Operating 10 96 95 96 non condensing H
3. GS1100 16 GS1100 24 16 port 24 port Unmanaged Gigabit Ethernet Switch Edition 1 6 2010 ZyXEL Copyright 2010 ZyXEL Communications Corporation www zyxel com About This User s Guide About This User s Guide Intended Audience This manual is intended for people who want to configure the Switch using the web configurator Documentation Feedback Send your comments questions or suggestions to techwriters zyxel com tw Thank you The Technical Writing Team ZyXEL Communications Corp 6 Innovation Road Il Science Based Industrial Park Hsinchu 30099 Taiwan Need More Help More help is available at www zyxel com FET NEN NNNNN M Download Library gt Firmware Knowledge Base Software Glossary Driver Support amp Feedback Datasheet Warranty Information Tech Doc Overview ZyXEL Windows Vista Support User s Guide Forum Quick start guide CLI Reference Guide Support note Certification Declaration SNMP MIB File Download Library Search for the latest product updates and documentation from this link Read the Tech Doc Overview to find out how to efficiently use the User Guide Quick Start Guide and Command Line Interface Reference Guide in order to better understand how to use your product Knowledge Base If you have a specific question about your product the answer may be here This is a collection of answers to previously asked questions about ZyXEL products Forum This c
4. ONLY qualified service personnel should service or disassemble this device Please contact your vendor for further information Make sure to connect the cables to the correct ports Place connecting cables carefully so that no one will step on them or stumble over them Always disconnect all cables from this device before servicing or disassembling Use ONLY an appropriate power adaptor or cord for your device Connect it to the right supply voltage for example 110V AC in North America or 230V AC in Europe Use ONLY power wires of the appropriate wire gauge for your device Connect it to a power supply of the correct voltage Do NOT allow anything to rest on the power adaptor or cord and do NOT place the product where anyone can walk on the power adaptor or cord Do NOT use the device if the power adaptor or cord is damaged as it might cause electrocution f the power adaptor or cord is damaged remove it from the device and the power source Do NOT attempt to repair the power adaptor or cord Contact your local vendor to order a new one Fuse Warning Replace a fuse only with a fuse of the same type and rating PRODUCT COMPLI ES WITH 21 CFR 1040 10 AND 1040 11 PRODUIT CONFORME SELON 21CFR 1040 10 ET 1040 11 CLASS 1 LASER PRODUCT APPAREIL A LASER DE CLASSE 1 Your product is marked with this symbol which is known as the WEEE mark WEEE stands for Waste Electronics and Electrical Equipment It means that used elec
5. Switch The following table provides descriptions of the LEDs Figure 10 Front Panel LEDs GS1100 16 GS1100 16 1 LNK ACT 3 5 LNK ACT CJ 9 LNK ACT CI 13 LNK ACT CIJ GS1100 24 GS1100 24 1 4 73 4 9 6 W ATHRO Ooo amp 8 tO 11 2 7 InVFAT m D ooog 13 14 45 16 17 0 INKA CT m aoaoga 9 20 21 22 23 24 NKAT OO OOo n GS1100 Series User s Guide Chapter 2 Hardware Description and Connection The following table describes the LEDs Table2 The Front Panel LED Descriptions LED cor STATUS DESCRIPTION PWR Green On The Switch is on and receiving power Off The Switch is not receiving power LINK Green On The port is connected to an Ethernet network ACT Blinking The port is receiving or transmitting data Off The port is not connected to an Ethernet network 2 3 Hardware Installation For GS1100 16 you can place the Switch directly on top of your desk or have it rack mounted For GS110 24 the size is suitable for rack mounting and you can refer to Section 2 3 2 on page 18 for instruction Take note of the following The Switch should have a minimum 25 mm space around it for ventilation The Switch should be placed in a desk that has a level surface and that is able to support the weight of the Switch To start using it simply connect the power cables and turn on the Switch Note The GS1100 16 is a desktop device but it is also rackmou
6. a RACK Loss sce edet eit Re Re bre aaa A Pr RR EH 20 Chapter 3 Bil o i 23 3 1 Improper Network Cabling and Topology siccoiccsesscesssadicccsesestensanscosenressssaseectvviccseessenaaaenresians 24 Chapter 4 uit eR cuin O 25 Appendix A Legal Information ione ertet ute blstiustaib qe udo bte UI Se ad mee Boma SE iru te bUE 27 GS1100 Series User s Guide Table of Contents GS1100 Series User s Guide Getting to Know Your Switch 1 1 Introduction This chapter describes the key features benefits and applications of your Switch The Switch is a 10 100 1000 Mbps multi port switch that can be used to build high performance switched workgroup networks The Switch is a store and forward device that offers low latency for high speed networking The Switch is designed for workgroups departments or backbone computing environments for small businesses Figure 1 Front Panel GS1100 16 ZyXEL GS1100 16 AM z GS1100 GS1100 24 ZyXEL 1100 24 The GS1100 24 has two mini GBIC ports for uplink connection Use mini GBIC transceivers in these slots for connections to backbone Ethernet switches The Switch has a built in algorithm that automatically assigns priority to received packets It can operate in low power idle mode in compliance with IEEE 802 3az Energy Efficient Ethernet EEE 1 2 Features The following are t
7. e 23 Chapter 3 Troubleshooting 3 1 Improper Network Cabling and Topology Improper network cabling or topology setup is a common cause of poor network performance or even network failure Figure 15 Troubleshooting Improper Network Cabling and Topology PROBLEM CORRECTIVE ACTION Faulty cables Using faulty network cables may affect data rates and have an impact on your network performance Replace with new standard network cables Non Non standard cables may increase the number of network collisions and standard cause other network problems that affect your network performance network Refer to Section 2 2 3 on page 16 for more information on network cable cables types Cabling If you use longer cables than are needed transmission quality may be Length affected The network cables should not be longer than the limit of 100 meters Too many Too many hubs or repeaters between the connected computers in the hubs network may increase the number of network collision or other network between the computers in the network problems Remove unnecessary hubs from the network A loop in the data path A data path loop forms when there is more than one path or route between two networked computers This results in broadcast storms that will severely affect your network performance Make sure there are no loops in your network topology GS1100 Series User s Guide Product Specifications
8. ection Figure 14 Mounting the Switch on a Rack GS1100 24 2 Using a 2 Philips screwdriver install the M5 flat head screws through the mounting bracket holes into the rack 3 Repeat steps 1 and 2 to attach the second mounting bracket on the other side of the rack GS1100 Series User s Guide 2 Chapter 2 Hardware Description and Connection 22 GS1100 Series User s Guide Troubleshooting This section describes common problems you may encounter with the Switch and possible solutions Troubleshoot the Switch using the LEDs to detect problems The PWR LED on the front panel does not light up Check the connections from your Switch to the power source Make sure you are using the supplied power cord and that you are using an appropriate power source Refer to the product specifications Make sure the power source is turned on and that the Switch is receiving sufficient power f these steps fail to correct the problem contact your local distributor for assistance The LINK ACT LED does not light up when a device is connected Verify that the attached device s is turned on and properly connected to your Switch Make sure the network adapters are working on the attached devices Verify that proper network cable type is used and its length does not exceed 100 meters For more information on network cable types see Section 3 1 on page 24 GS1100 Series User s Guid
9. he essential features of the Switch Conforms to IEEE 802 3 802 3u 802 3ab and 802 3x standards GS1100 Series User s Guide 9 Chapter 1 Getting to Know Your Switch e Auto negotiating 10 100 1000 Mbps Ethernet RJ 45 ports Auto sensing crossover for all 10 100 1000 Mbps Ethernet RJ 45 ports Supports N Way protocol for speed 10 100 1000 Mbps and duplex mode Half Full auto detection Supports store and forward switching Supports automatic address learning Full wire speed forwarding rate An additional CoS feature 8 queues Embedded 8K MAC address table providing 8000 MAC addresses entries Refer to Chapter 4 on page 25 for the product specifications 1 3 Applications This section provides two network topology examples in which the Switch is used 1 3 1 Standalone Workgroup In this application the Switch is an ideal solution for small networks where rapid growth can be expected in the near future The Switch can be used standalone for a group of heavy traffic users You can connect computers directly to the Switch s port or connect other switches to the Switch In this example all computers can share high speed applications on the server To expand the network simply add more networking devices such as switches routers computers print servers etc Figure 2 Standalone Workgroup Example GS1100 Series User s Guide Chapter 1 Getting to Know Your Switch 1 3 2 Bridg
10. ing With its large address table and high performance the Switch is an ideal solution for department networks to connect to the corporate backbone or for connecting network segments The following figure depicts a typical segment bridge application of the Switch in an enterprise environment The two networks RD and Sales the standalone server and the computers can all communicate with each other and share all network resources Figure 3 Bridging Example NN gue e a conccence s Sales H i y mmm GS1100 Series User s Guide EN Chapter 1 Getting to Know Your Switch 12 GS1100 Series User s Guide Hardware Description and Connection 2 1 Rear Panel The three pronged power receptacle is located on the rear panel of the Switch Refer to the Product Specifications on page 25 for power specification Figure 4 Rear Panel GS1100 16 GS1100 24 2 1 1 Rear Panel Power Connection Connect one end of the supplied power cord to the power receptacle on the back of the Switch and the other end to the appropriate power source For GS1100 16 use the ON OFF switch to have the Switch power on or off 2 2 Front Panel The front panel of the Switch includes the auto negotiating 10 Base T 100 Base TX 1000 Base T RJ 45 ports and the LEDs The GS1100 24 has two mini GBIC ports Refer to Section 2 2 2 on page 14 for more information GS1100 Serie
11. mple ENTER means the enter or return key on your keyboard Enter means for you to type one or more characters and then press the ENTER key Select or choose means for you to use one of the predefined choices Units of measurement may denote the metric value or the scientific value For example k for kilo may denote 1000 or 1024 M for mega may denote 1000000 or 1048576 and so on e e g is a shorthand for for instance and i e means that is or in other words Icons Used in Figures Figures in this User s Guide may use the following generic icons The Switch icon is not an exact representation of your device The Switch Computer Notebook computer E __ N lt gt NES Nec Ss Server Ill GS1100 Series User s Guide 5 Safety Warnings Safety Warnings Do NOT use this product near water for example in a wet basement or near a swimming pool Do NOT expose your device to dampness dust or corrosive liquids Do NOT store things on the device Do NOT install use or service this device during a thunderstorm There is a remote risk of electric shock from lightning Do not obstruct the device ventillation slots as insufficient airflow may harm your device Connect ONLY suitable accessories to the device Do NOT open the device or unit Opening or removing covers can expose you to dangerous high voltage points or other risks
12. nce that may cause undesired operations FCC Warning This device has been tested and found to comply with the limits for a Class A digital switch pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial GS1100 Series User s Guide Appendix A Legal Information environment This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Notices Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Viewing Certifications Go to http www zyxel com 2 Select your product on the ZyXEL home page to go to that product s page 3 Select the certification you wish to view from this page ZyXEL Limited Warranty ZyXEL warrants to the original end user purchaser that this product is free from any defects in materials or workmanship for a period of up to two years from the da
13. nd information at www zyxel com for global products or at www us zyxel com for North American products GS1100 Series User s Guide Appendix A Legal Information GS1100 Series User s Guide Index Numerics 10 100 1000 Mbps 9 A Applications 10 Segment Bridge 11 auto negotiating ports 14 C Cabling Length 24 certifications 27 notices 28 viewing 28 copyright 27 D Data path loop 24 disclaimer 27 EEE 9 F Faulty cables 24 FCC interference statement 27 Front Panel 13 Front Panel Connections 16 Index installation precautions 18 transceivers 14 L LED Descriptions LK ACT 17 PWR 17 mounting brackets 19 N network cable crossover 16 straight through 16 Network Cable Types 16 Non standard network cables 24 P product registration 29 Product specification 25 R rack mounting 18 Rear Panel 13 Rear Panel Power Connection 13 GS1100 Series User s Guide ES Index registration product 29 S safety warnings 6 Small Form factor Pluggable SFP 14 Standalone Workgroup 10 syntax conventions 5 T transceiver MultiSource Agreement MSA 14 transceivers 14 installation 14 removal 15 Troubleshooting Improper Network Cabling and Topology 24 W wall mounting 17 warranty 28 note 28 32 GS1100 Series User s Guide
14. ntable and wall mountable Ask an authorized technician to attach the Switch to the rack wall 2 3 1 Wall Mounting GS1100 16 Only Do the following to attach your Switch to a wall 1 Screw the two screws provided with your Switch into the wall 150 mm apart see the figure in step 2 Use screws with 6 mm 8 mm 0 24 0 31 wide heads Do not screw the screws all the way in to the wall leave a small gap between the head of the screw and the wall The gap must be big enough for the screw heads to slide into the screw slots and the connection cables to run down the back of the Switch Note Make sure the screws are securely fixed to the wall and strong enough to hold the weight of the Switch with the connection cables GS1100 Series User s Guide Chapter 2 Hardware Description and Connection 2 Align the holes on the back of the Switch with the screws on the wall Hang the Switch on the screws Cn 450 mm The Switch should be wall mounted horizontally The Switch s side panels with ventilation slots should not be facing up or down as this position is less safe 2 3 2 Rack Mounting The Switch can be mounted on an EIA standard size 19 inch rack or in a wiring closet with other equipment Follow the steps below to mount your Switch on a standard EIA rack using a rack mounting kit Rack mounted Installation Requirements Two mounting brackets Eight M3 flat head screws and a 2 Philips screwdriver
15. of PCB board facing down Press the transceiver firmly until it clicks into place The Switch automatically detects the installed transceiver Check the LEDs to verify that it is functioning properly Close the transceiver s latch latch styles vary GS1100 Series User s Guide Chapter 2 Hardware Description and Connection 5 Connect the fiber optic cables to the transceiver Figure5 Transceiver Installation Example Figure 6 Connecting the Fiber Optic Cables 2 2 2 2 Transceiver Removal Use the following steps to remove a mini GBIC transceiver SFP module 1 Remove the fiber optic cables from the transceiver 2 Open the transceiver s latch latch styles vary 3 Pull the transceiver out of the slot Figure 7 Removing the Fiber Optic Cables GS1100 Series User s Guide 15 Chapter 2 Hardware Description and Connection 2 2 3 Front Panel Connections You can use unshielded twisted pair UTP or shielded twisted pair STP Ethernet cables for RJ 45 ports The following table describes the types of network cable used for the different connection speeds Table 1 Network Cable Types SPEED NETWORK CABLE TYPE 10 Mbps Category 3 4 or 5 UTP STP 100 Mbps Category 5 UTP STP 1000 Mbps Category 5e 6 UTP STP You can use either crossover or straight through cables for all the ports 2 2 4 Front Panel LEDs The LED Indicators give real time information about the status of the
16. ontains discussions on ZyXEL products Learn from others who use ZyXEL products and share your experiences as well GS1100 Series User s Guide 3 About This User s Guide Customer Support Should problems arise that cannot be solved by the methods listed above you should contact your vendor If you cannot contact your vendor then contact a ZyXEL office for the region in which you bought the device See http www zyxel com web contact us php for contact information Please have the following information ready when you contact an office Product model and serial number Warranty Information Date that you received your device Brief description of the problem and the steps you took to solve it 4 GS1100 Series User s Guide Document Conventions Document Conventions Warnings and Notes These are how warnings and notes are shown in this User s Guide Warnings tell you about things that could harm you or your device Note Notes tell you other important information for example other things you may need to configure or helpful tips or recommendations Syntax Conventions The GS1100 16 and GS1100 24 may be referred to as the Switch the device the system or the product in this User s Guide Differentiation is made where needed Product labels screen names field labels and field choices are all in bold font A key stroke is denoted by square brackets and uppercase text for exa
17. s User s Guide 13 Chapter 2 Hardware Description and Connection 2 2 1 RJ 45 Auto negotiating Ports The 10 Base T 100 Base TX 1000 Base T RJ 45 ports are auto negotiating and auto crossover An auto negotiating port can detect and adjust to the optimum Ethernet speed 10 100 1000 Mpbs and duplex mode full duplex or half duplex of the connected device An auto crossover auto MDI MDI X port automatically works with a straight through or crossover Ethernet cable 2 2 2 Mini GBIC Slots GS1100 24 Only These are slots for mini GBIC Gigabit Interface Converter transceivers A transceiver is a single unit that houses a transmitter and a receiver The Switch does not come with transceivers You must use transceivers that comply with the Small Form factor Pluggable SFP Transceiver MultiSource Agreement MSA See the SFF committee s INF 8074i specification Rev 1 0 for details You can change transceivers while the Switch is operating You can use different transceivers to connect to Ethernet switches with different types of fiber optic or even copper cable connectors To avoid possible eye injury do not look into an operating fiber optic module s connectors Type SFP connection interface Connection speed 1 Gigabit per second Gbps 2 2 2 1 Transceiver Installation Use the following steps to install a mini GBIC transceiver SFP module Insert the transceiver into the slot with the exposed section
18. te of purchase During the warranty period and upon proof of purchase should the product have indications of failure due to faulty workmanship and or materials ZyXEL will at its discretion repair or replace the defective products or components without charge for either parts or labor and to whatever extent it shall deem necessary to restore the product or components to proper operating condition Any replacement will consist of a new or re manufactured functionally equivalent product of equal or higher value and will be solely at the discretion of ZyXEL This warranty shall not apply if the product has been modified misused tampered with damaged by an act of God or subjected to abnormal working conditions Note Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser This warranty is in lieu of all other warranties express or implied including any implied warranty of merchantability or fitness for a particular use or GS1100 Series User s Guide Appendix A Legal Information purpose ZyXEL shall in no event be held liable for indirect or consequential damages of any kind to the purchaser To obtain the services of this warranty contact your vendor You may also refer to the warranty policy for the region in which you bought the device at http WWW Zyxel com web support warranty info php Registration Register your product online to receive e mail notices of firmware upgrades a
19. trical and electronic products should not be mixed with general waste Used electrical and electronic equipment should be treated separately 6 GS1100 Series User s Guide Table of Contents Table of Contents 1 dic 7 Chapter 1 Getting to df R5 9 OM riis eR ME TT TU LR simmer LIUIUS nnn seater one 9 jd e 9 yer ioi a eem RTT TTE 10 Tad Standalone WOE eie TT 10 gS B e s Mere ee Rene ee ern LU LS err eter re 11 Chapter 2 Hardware Description and Connection eeeeeeeeeee eese eene nennen nnne nnne nnn 13 NI CU meet eve pm re 13 2 1 1 Bear Panel Power ConliBOllOTI iuc rore y Foec cun esc ene Encre IRR niaaa c IK ERE cC C cx 13 SIME PPAR uurossspotia uc Ee Ea U ELDER GE 13 ACA MI icing ann rMzsr eT 14 2 2 8 Mint GBIC Slots 5110024 Dl aunir db ppc REproc o acoge radeon ca s 14 REP Dalhsceesr Metalai arsuri a 14 2 22 2 Transceivel PO eoVal 2ucucccodis eu SEE iei an 15 225 Pan Panel GEB OS sinc rre ti ERR Feb b olii d o Cd RP baia d P ni 16 224 Fon Pansi LEDS V aueittsesdivitosrimute et nM dia tns 16 23 hardware nerd all seriosi i CERERI NE ER Feste E E RS REPRE eta RE EE DIN pa Co dE 17 23 Wal Mounting GS TOOG ONIYI sinensis cio abeo boa an oa eas dd aud 17 Eus ROCKON e a epe based QN ede exe ORE RE FT dee bee ied o Fev D OM DEREN 18 23 3 Mounino e Switeh gn
20. umidity Power Supply Power rating 100 240 V 50 60 Hz 0 5 A Max Power consumption GS1100 16 6 4 W GS1100 24 16 2 W Safety EN 60950 1 EMC FCC Part15 Class A CE EMC Class A GS1100 Series User s Guide Legal Information Copyright Copyright 2010 by ZyXEL Communications Corporation The contents of this publication may not be reproduced in any part or as a whole transcribed stored in a retrieval system translated into any language or transmitted in any form or by any means electronic mechanical magnetic optical chemical photocopying manual or otherwise without the prior written permission of ZyXEL Communications Corporation Published by ZyXEL Communications Corporation All rights reserved Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products or software described herein Neither does it convey any license under its patent rights nor the patent rights of others ZyXEL further reserves the right to make changes in any products described herein without notice This publication is subject to change without notice Certifications Federal Communications Commission FCC Interference Statement This device complies with Part 15 of FCC rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interfere

Download Pdf Manuals

image

Related Search

Related Contents

LevelOne 54Mbps Wireless PCMCIA Card    怖い!火災による CO(一酸化炭素)中毒  www.philips.com/welcome  

Copyright © All rights reserved.
Failed to retrieve file