1. Push fit the recirculation adapter item 15 on to extension pipe item 14 Insert the recirculation outlet extensions item 14 4 into the recirculation adapter item 15 The recircualtion grilles item 8a and 8b must be fitted after the lower chimney item 2 2 has been fitted Electrical Connection Connect the hood to the mains supply via a double pole switch having a contact gap of at least 3mm INSTALLING THE COOKER HOOD IS Fitting the Chimney Stack The chimney consists of two sections The upper chimney measures 215mm and the lower chimney 1 2 1 with the holes for recirculation on either side measures 740mm Upper Chimney Stack Expand the sides of the upper chimney stack item 2 1 and place the chimney over the two brackets 7 2 1 ensuring they are well seated Secure the chimney stack to the brackets 7 2 1 using the four self tapping screws 12c 2 0x6 5mm Lower Chimney Stack Expand the of the lower chimney stack item 2 2 and place the chimney over the upper chimney stack item 2 1 and the canopy item 1 Secure the chimney stack to the canopy using the two screws item 12c 2 9x6 5mm After the chimney has been secured into position insert the two plastic recirculation grilles item 8a right hand and 8b left hand in the apertures on each side of the chimney The grilles are marked with two arrows and should be fitted with one arrow pointing upwards and the other toward the front
2. When the hood is used in the recirculation mode ensure that the grilles are properly secured to the recirculation extension spigot 14 1 15 16 17 18 Dir 89 336 CEE 73 23 CEE Electrolux plc 2002 436000659 02 020626
3. ZANUSSI Thank you for buying a Zanussi product To enable you to use your appliance effectively and safely please read this instruction book carefully before using the appliance and retain for future reference If you require guidance in the use of the appliance or require further information on Zanussi Products please contact our Customer Care Department Customer Care Department Zanussi 55 77 High Street Slough Berkshire SL1 1DZ Tel 08705 727 727 To register ownership please ensure you complete and return the guarantee card sup plied with the appliance For the User Important Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Metal Grease Filters Charcoal Filters To Remove Replace the Charcoal Filters Changing the Light Bulb Something Not Working Service and Spare Parts Guarantee Conditions For the Installer Technical Information Electrical Connection Electrical Requirements Electrical Connection Installing the Cooker Hood Installation Requirements Unpacking Clearance Heights Fitting the Wall Brackets Fitting the Canopy Hood Venting Recirculation Fitting the Chimney Stack Guide to use the instruction book The following Symbols will be found in the text to guide you through the instruction book AN Safety instructions ES Step by step instructions IMPOR
4. e Damage or calls resulting from transportation improper use or neglect the replacement of any lamps or removable parts of glass or plastic e Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom e Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements e Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI EUROPEAN GUARANTEE If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications e The guarantee starts from the date you first purchased the product e The guarantee is for the same period and to the same extent for labour and parts as exists in the new country of use for this brand or range of products e This guarantee relates to you and cannot be transferred to another user e Your new home is within the European Community EC or European Free Trade Area e The product is installed and used in accordance with our instructions and is only used domestically i e a normal household Before you move please contact your nearest Customer Care Centre listed below to give them detailsof your new home They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances France Sen
5. as shown at 215mm below the first bracket at X Mark the hole centres for the bracket fixing screws on the wall 13 INSTALLING THE COOKER HOOD Fitting the Canopy Hood Before starting to fix the canopy tighten the two screws Vr located on the canopy mouiunting brackets Hook the canopy onto the screws not supplied Tighten up the screws Adjust the screws item Vr to level the canopy The fixings come together with the splashback Ducting the Cooker Hood When installing the cooker hood in the ducting mode connect the hood using either 150 or 120mm flexible or rigid pipe The choice of ducting should be specified by the installer but 150mm rigid ducting will ensure the best performance possible AN The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102 B1 IS Fitting the Ducting To install 8120mm ducting fit the ducting spigot 150 120mm item 9 on to the spigot on top of the canopy To install 8150mm ducting fit the ducting on the spigot on top of the canopy Remove the activated charcoal filter Recirculating the Cooker Hood The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter already fitted IS Fitting the Recirculation Duct Assemble the two halves of the ducting extension pipe item 14 Push fit the extension pipe on to the ducting spigot on top of the canopy
6. 150 120 Ducting Spigot 14 1No Ducting Extension Pipe 141 2No Recirculation Outlet Extentions 15 1No Recirculation Outlet Adapter Ref Qty Installation Components 7 2 1 2No Upper Chnimey Fixing Brackets 12c 6No Chimney Fixing Screws 2 9x6 5mm Ref Qty Documents 1No Instruction Booklet 1 No Guarantee Card 1No Questionnaire This cooker hood is designed to be fixed to any vertical surface over a cooking area and can be used in the extraction ducted to the outside or recirculation mode The installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation INSTALLING THE COOKER HOOD Hob A Built in Electric Hob 650mm clearance B Built in Gas Hob 700mm clearance C Slot in Electric Cooker 685mm clearance D Slot in Gas Cooker 767mm clearance Clearance Heights The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated providing the maximum output of the appliance beneath does not exceed the maximums quoted in the Technical Specifications If the output of the appliance below the cooker hood exceeds the maximum outputs quoted please refer to the cooker manufacturer s installation instructions A clearance height of 650mm 25 1 2 ins is requi
7. 3 Part electrician e g your local Electricity Board ora 4 fitted with a 3 Amp fuse is a recommended contractor who is on the roll of the National mains supply connection accessory to ensure Inspection Council for Electrical Installation compliance with the Safety Requirements Contracting NICEIC applicable to fixed wiring instructions Electrical Connection This appliance conforms to BS 800 1988 and EEC Before connecting to the mains supply ensure Directive No 78 308 regarding suppression of on the rating plate inside the cooker hood 10 INSTALLING THE COOKER HOOD Please ensure that when the appliance is installed it is easily accessible to an engineer in the event of a breakdown All installations must comply with the local IN authorities requirements for the discharge of exhaust air Incorrect installation may affect the safety of this cooker hood Installation Requirements Before installation check that the wall to which the cooker hood is to be fitted for electric cables water pipes and gas Unpacking Before unpacking the cooker hood position the carton with the arrows pointing upwards as illustrated on the carton Ref Qty Product Components 1 1 No Canopy complete with Controls Lighting Fan Assembly Grease Filter Charcoal Filter 2 1No Telescopic Chimney comprising 2 1 1No Upper Chimney Stack 2 2 1 No Lower Chimney Stack 8a 1No Right Hand Recirculation grille 8b 1No Left Hand Recirculation grille 9 1No
8. TANT SAFETY INFORMATION These warnings are provided in the interests of safety Ensure that you understand them all be fore installing or using this appliance Your safety is of paramount importance If you are unsure about any of the meanings of these warnings contact the Customer Care Department Installation Any installation work must be undertaken by a qualified electrician or a competent person This hood must be installed in accordance with the installation instructions and all measurements must be adhered to If the cooker hood is installed for use above a gas appliance then the provision for ventilation must be in accordance with the Gas Safety Codes of Practice BS 6172 BS 5440 and BS 6891 Natural Gas and BS 5482 LP Gas 1994 the Gas Safety Installation amp Use Regulations the Building Regulations issued by the Department of the Environment the Building Standards Scotland Consolidated Regulations issued by the Scottish Development Department The fan motor of this cooker hood incorporates a cut out device which will operate if the cooker hood is installed below the height recommended under the section Clearance Height or if the motor becomes overheated If the cut out device is activated switch off the fan motor and allow the cooker hood to cool The cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in an
9. by hand using mild soapy water or can be machine washed in a dishwasher Allow to dry completely before replacing To Remove the Grease Filter Remove the metal grease filter by pushing IS inwardly on the two steel handles replace making sure the handles have sprung back into position and are completely visible MAINTENANCE AND CLEANING Charcoal Filter The charcoal filter cannot be cleaned or regenerated it should be replaced approximately every three months or more frequently if the hood is used for more than three hours per day L To Remove the Charcoal Filter Remove the metal grease filter Release the fixing hooks and remove the charcoal filter from the recess Insert the replacement filter into the recess and replace the hooks Replace the metal grease filter This appliance can be a possible fire IN hazard ifthe grease and charcoal filters are not cleaned and replaced as recommended Worktop Lighting The lamps should be replaced with a 230V 20W halogen spot lamp IS To Replace the Lamps Unscrew the two screws to release the metal surround Remove the lamp from the holder by pulling the lamp downwards Replace the spot lamp with an identical replacement When fitting the new lamp ensure the two pins are properly inserted into the slots in the lamp holder Charcoal filters grease filters and lamps can be obtained from your local Service Force Centre SOMETHING NOT WORKING If having fol
10. designed to extract unpleasant odours from the kitchen it will not extract steam Cooker Hood Controls The cooker hood functions are controlled by five push button switches located centrally in the control fascia L L Push to switch ON the worktop lighting S Red neon indicates the fan motor is switched ON V1 Push to switch ON the motor at the low speed for use with one burner or when simmering V2 Push to engage the medium speed for normal cooking up to four pans V3 Push to engage the high speed for use when frying or cooking foods with strong odours To Operate Select the required fan speed and light if required The appliance can be installed to recirculate or extract contaminated air The cooker hood is more effective when used in the extraction mode Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted The contaminated air is cleaned by passing through the filters and then back into the kitchen The activated charcoal filter absorbs odours arising from cooking In use it will slowly become saturated in grease and less effective The filter normally requires changing at least every three months or more frequently if the hood is used for more than three hours per day Extraction The contaminated air enters the cooker hood passing through the grease filters and out through the ducting into the atmosphere When used in the extract mod
11. e the charcoal filter is not required and must be removed Never do flambe cooking under this cooker hood Take extra care when frying and never leave frying pans unattended during use as over heated fats and oils can catch fire Do not leave naked flames under the cooker hood Ensure the hood is switched ON before using the hob Ensure heating areas on your hob are covered with pots and pans when using the hob and cooker hood simultaneously Ensure not to damage the charcoal filter when cleaning or replacing as the activated charcoal inside is saturated with grease which will stain if it comes into contact with clothing or furnishings MAINTENANCE AND CLEANING Before carrying out any maintenance or cleaning isolate the cooker hood from the mains supply The cooker hood must be kept clean as a build up of grease or fat can be a fire hazard External Cleaning The metal casing visor and chimney should be cleaned at least once a month to keep the hood looking like new Wipe over the hood with a soft cloth wrung out in mild soapy water and then dry thoroughly N Always wear protective gloves when cleaning the hood Never use scouring pads or abrasive cleaners as they may scratch of damage the surfaces Never use excessive amounts of water when cleaning particularly around the control panel Metal Grease Filter The metal grease filter should be cleaned at least every month The filter may be washed
12. erviceforce co uk For general assistance with your appliance or for further information on Zanussi products please contact our Customer Care Department Customer Care Department Zanussi 55 77 High Street Slough Berkshire SL1 1DZ Telephone 08705 727 727 calls to this number may be recorded for training purposes GUARANTEE CONDITIONS We Zanussi undertake that if within twenty four months of the date of the purchase this Zanussi built in product or any part thereof is proved to be defective by reason only of faulty workmanship or materials the company will at our option repair or replace the same FREE OF ANY CHARGE for labour materials or Carriage on condition that e The appliance has been correctly installed and used only on the electrical supply stated on the rating plate e The appliance has been used for normal domestic purposes only and in accordance with the manufacturer s operating and maintenance instructions e The appliance has not been serviced maintained repaired taken apart or tampered with by any person not authorised by us e All service work under this guarantee must be undertaken by a Zanussi Service Force Centre e Any appliance or defective part replaced shall become the property of this company Home visits are made between 8 30am and 5 30pm Monday to Friday Visits may be available outside these hours in which case a premium will be charged EXCLUSIONS This Guarantee does not cover
13. lis 33 0 3 44 62 22 22 Germany Nurnberg 49 0 911 323 2600 Italy Pordenone 39 0 1678 47053 Sweden Stockholm 46 0 20 78 77 50 United Kingdom Slough 44 0 1753 219897 INSTALLATION INSTRUCTIONS AN It is dangerous to alter the specifications or attempt to modify this product in any way Technical information DIMENSIONS HEIGHT OF CANOPY 73mm HEIGHT OF CHIMNEY UPPER SECTION 215mm LOWER SECTION 740mm WIDTH OF CANOPY 898mm DEPTH OF CANOPY 500mm WEIGHT GROSS 24 00kg WEIGHT NET 19 40kg ELECTRICAL SUPPLY VOLTAGE 50Hz 230V POWER CONSUMPTION 240W FAN MOTOR 200W LAMPS 2 x20W Halogen 40W SUITABLE FOR INSTALLATION ABOVE ELECTRIC HOB 7KW MAX GAS HOB 10KW MAX SLOT IN ELECTRIC COOKER 12 4KW MAX SLOT IN GAS COOKER 13 5KW MAX Note CE Marking certifies that this appliance complies with the requirements laid down in EEC directive 89 336 Electromagnetic compatibility and subsequent modifications and Low Votage directive 72 23 E N THIS APPLIANCE MUST BE EARTHED Electrical Requirements This appliance is fitted with a 3 core mains cable Any permanent electrical installation must and must be permanently connected to the comply with the latest I E E Regulations and electricity supply via a double pole switch having local Electricity Board regulations For your own 3mm minimum contact gap on each pole A safety this should be undertaken by a qualified Switched Fuse Connection Unit to BS 136
14. lowed these instructions carefully your cooker hood fails to work properly please carry out the following checks he cooker hood will not start he cooker hood has switched off during pperation If after all these checks the fault persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee service calls Check the hood is connected to the electricity supply Make sure the switch is in the ON position The fan speed is set high enough for the task The grease filter is clean The kitchen is adequately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown SERVICE AND SPARE PARTS If you require an engineer or spare parts contact your local Service Force Centre by telephoning 08705 929929 Your telephone call will be routed to your local Service Force Centre For the address of your local Service Force Centre and further information about Service Force please visit the website at www s
15. red when installed above a built in electric hob or 700mm 27 1 2 ins when installed above a built in gas hob A clearance height of 685mm 27ins is required when installing above a slot in electric cooker or 787mm 30 1 2 ins when installed above a slot in cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm 17 3 4 ins a gap of 50mm 2ins must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high level grill 12 INSTALLING THE COOKER HOOD IS Fitting the Wall Brackets Mark a hole centre on the horizontal line Draw a vertical line on the wall from the centre of 965mm above the worktop 116mm either the cooking appliance up to the ceiling or as high side of the vertical line as indicated as the adjoing wall cabinets using a spirit level Drill the holes marked on the wall using a and marker pen This is to ensure the correct 8mm drill bit vertical alignment of the appliance 5 Fix the two brackets item 7 2 1 Draw a horizontal line 965mm above the hob Place bracket item 7 2 1 on the wall as shown about 1 2mm from the ceiling or upper limit aligning notch in the centre of the bracket with the vertical line Mark the hole centres for the bracket fixing screws on the wall Place bracket item 7 2 1 on the wall
16. y way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the cooker hood is to be used contains a fuel burning appliance such as acentral heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room The ducting system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose Do not install above a cooker with a high level grill Child Safety This appliance is designed to be operated by adults Children should not be allowed to tamper with the appliance During Use This product is for domestic use only Never leave frying pans unattended during use as overheated fats and oils might catch fire Never do flamb cooking under this cooker hood Do not leave naked flames under the cooker hood Maintenance and Service This appliance can be a hazard if the grease filters and charcoal filters are not cleaned and replaced as recommended Under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may Cause injury or more serious malfunction Refer to your local Zanussi Service Force Centre Always insist on genuine spare parts YOUR APPLIANCE 950 max OPERATING INSTRUCTIONS This cooker hood is