Home

York 112 User's Manual

image

Contents

1. CSROO Fan speed selector wall mounted CMRO0 Thermostat with manual fan speed and S W change over wall mounted Thermostat with manual fan speed dead band CEROO ie automatic change over buit in Thermostat with automatic fan speed dead band CER20 automatic change over buit in Thermostat with automatic fan speed dead band CER30 automatic change over for modulating valves buit in CBL20 Parallel connection for ON OFF valve e Q CBL30 Parallel connection for modulating valve e e e e Valves Condensate pump Water sensor Minimum temperature thermostat Factory fitted J3A2 2p 3 way 4 ports on off valves for 2 pipe systems J3A2 4p 3 way 4 ports on off valves for 4 pipe systems J3AM 2p 3 way 4 ports modulating valves for 2 pipe systems J3AM 4p 3 way 4 ports modulating valves for 4 pipe systems e Shut off valves for 2 pipe systems DT 2P n addition to J3A2 J3AM valves s 2 id s Shut off valves for 4 pipe systems DT 4P n addition to J3A2 J3AM valves s s id s Condensate pump e e e e e e WS Water sensor TM Minimum temperature thermostat Feets and panels
2. CP1 Set of painted feet ZL1 Set of feet frontal socle PPV1 Vertical painted back panel PPH1 Horizontal painted back panel External air intake PA Air intake plenum PAS Air intake plenum collars PA90 90 air intake plenum RCA Air intake duct fitting PM Air delivery plenum with collars 90 air delivery plenum Compatible 73 Compatible with conditions EE Not compatible Maximum of rows is indicated in the documentation the maximum number of rows includes the heating row or electrical heater
3. WS sensor change over for CEL CER WS e Minimum temperature thermostat TM o Accessories Supplied loose Remote controllers and thermostat wall mounted Fan speed selector CSROO o Thermostat with manual fan speed and S W change over CMROO Thermostat with manual fan speed dead band automatic CEROO e change over Thermostat with automatic fan speed dead band automatic CER20 e change over Thermostat with automatic fan speed dead band automatic CER30 e change over for modulating valve 1 for check compatibility with the models of FCU see compatibility table EUROVENT IFIED PERFORM D mM e n S 5 low body E body P V vertical P V vertical P without cabinet LOW BODY YLVR Een NN SS DIMENSIONS AND WEIGHTS Dim 110 112 114 216 218 A 648 773 898 1023 1148 ae B 374 499 624 749 874 dup eee C 254 254 254 254 254 Z Ra aa D 174 174 174 174 174 SS SS SS SS E 100 100 100 100 100 ASIE G 170 170 170 170 170 H 101 101 101 101 101 J 430 430 430 430 430 N 245 245 245 245 245 0 154 154 154 154 154 P 31 31 31 31 31 Q 47 47 47 47 47 R 304 304 304 304 304 S 88 88 88 88 88 T 87 87 87 87 87 U 65 65 65 65 65 V 47 47 47 47 47 W 84 84 84 84 84 X 214 214 214 214 214 7 109 109 109 109 109 0 20 20 20 20 20 kg 15 17 22 23 26 All dimensions in mm m EH N
4. ENEC ee mot EHI d ai mS 1 ai YLVR Fan Coil Unit LOW BODY AE LOW BODY YLIVR DIMENSIONS AND WEIGHTS Dim 110 112 114 216 218 A 955 680 805 930 1055 374 499 624 749 874 C 230 230 230 230 230 D 108 108 108 108 108 E 73 73 73 73 73 G 170 170 170 170 170 H 101 101 101 101 101 J 395 395 395 395 395 K 61 61 61 61 61 L 349 474 599 724 849 M 127 127 127 28 28 N 245 245 245 245 245 0 154 154 154 154 154 P 31 31 31 31 31 Q 47 47 47 47 47 R 304 304 304 304 304 S 88 88 88 88 88 T 87 87 87 87 87 U 65 65 65 65 65 V 47 47 47 47 47 W 84 84 84 84 84 X 214 214 214 214 214 Y 201 201 201 201 201 Z 109 109 109 109 109 0 20 20 20 20 20 kg 9 11 14 16 19 All dimensions in mm D EE N E Tu A Compatibility tables for FCU LASER and LOW BODY CELOO Built in CEROO Wall mounted Thermostat with manual fan speed and automatic change over CEL20 Built in CER20 Wall mounted Thermostat with auto fan speed and automatic change over CEL30 Built in CER30 Wall mounted Thermostat with auto fan speed and automatic change over for modulating valve CSLOO Built in CSRO00 Wall mounted Fan speed selector FEATURES CEL CER Dead band for change over 5 C or 2 C factory set 2 C for 4 pipes and 5 C for 2 pipes Manual fan speeds or a
5. U me 2 Features Thermostats e 6 speed fan x 5100 Built x 00 Wall mounted Cabinet factory fitted e Valve factory fitted CMLOO Built in e Electrical heater factory fitted Ec pex CMROO Wall mounted call d Thermostat with manual fan speed and S W e Thermal or modulating valve PNE MM 00 Built in gt CEROO Wall mounted Thermostat with manual fan speed and automatic change over CEL20 Built in CER20 Wall mounted Thermostat with auto fan speed and automatic change over CEL30 Built in CER30 Wall mounted Fan Coil Unit ome LOW BODY 2 amp 4 pipe system A complete range from 0 8 kW up to 2 7 kW Selection software Technical features YLVR YLIVR Model 110 112 114 216 218 Cooling capacity 1 2 rows W 832 1054 1493 2041 2356 Cooling capacity 1 3 rows W 913 1266 1790 250 2114 Heating capacity 2 1 row W 1167 1691 2319 3029 9092 Pressure drop 3 kPa 7 1 7 3 8 9 11 7 Power supply V Ph Hz 230 1 50 E Sound power level 3 dB A 49 50 53 53 55 Sound pressure level at 3 m dB A 31 32 35 35 37 Water connections inch 1 2 Dimensions indicated next page 1 Cooling capacities based on 7 C EWT At 5 C indoor temperature 27 C DB 19 C WB 2 pipes high speed fan 2 Heating capacities based on 70 C EWT At 10 C indoor temperature 20 C 2 pipes high speed fan 3 In cool
6. allel connection Water Min Temp Heaters ON OFF Modulating sensor Thermostat KREL CBL20 CBL30 WS TM e CSROO Fan speed selector a 00 Thermostat with manual fan speed and S W change over CEROO Thermostat with manual fan speed dead band e automatic change over Thermostat with automatic fan speed dead band CER20 automatic change over Thermostat with automatic fan speed dead band CER30 automatic change over for modulating valve Compatible ME Not compatible Compatibility tables for FCU LASER and LOW BODY Compatibility Options Accessories Models STANDARD LOW BODY LASER CONCEALED Code designation YLV YLH YLV AF YLH AF YLIV YLIH YLIV AF YLIH AF YLVR YLIVR Coils and heaters BA1 Additionnal 1 row heating e KREL Kit electrical heater with safety thermostat and relay Factory fitted thermostat 5100 Fan speed selector buit in CMLOO Thermostat with manual fan speed and S W change over buit in Thermostat with manual fan speed dead band CELOO s automatic change over buit in Thermostat with automatic fan speed dead band CEL20 automatic change over buit CEL30 Thermostat with automatic fan speed dead band automatic change over for modulating valves buit in Remote controllers and thermostats
7. ing mode 2 rows For other conditions contact York international al YORK Fan Coil Unit LOW BODY E 0 8 to 2 7 kW I Compatibility table Codes Model 110 112 114 216 218 With Cabinet YLVR 2 rows e e e e 3 rows e o 4 rows e Without Cabinet YLIVR 2 rows amp e e amp 3 rows e 4 rows e e Options Factory fitted Coil and heaters 1 row heating BAI e Kit electrical heater with relay and safety switch KREL Built in thermostat Fan speed selector CSLOO e Thermostat with manual fan speed and S W change over CMLOO Thermostat with manual fan speed dead band automatic CELOO e change over Thermostat with automatic fan speed dead band automatic CEL2O e change over Thermostat with automatic fan speed dead band automatic 30 change over for modulating valve Parallel connection For ON OFF valve one FCU 20 For modulating valve one FCU CBL30 3 way valve factory fitted For 2 pipe systems ON OFF J3A2 2p o For 4 pipe systems ON OFF J3A2 4p e 3 way modulating valve factory fitted For 2 pipe systems Modulating J3AM 2p e For 4 pipe systems Modulating J3AM 4p Shut off valves factory fitted For 2 pipe systems DT 2p For 4 pipe systems DT 4p Condensate pump PC
8. utomatic models 20 and 30 Thermostated fan control or continuous fan running Option water sensor WS for change over on coil for 2 pipes Led indicated status summer winter or dead band CMLOO Built in CMRO00 Wall mounted Thermostat with manual fan speed and S W change over Temperature setting for 7 to 30 C comfort 20 25 e Plastic pins for limiting temperature range Input for window contact Input for Economy occupancy mode Output for remote alarm Filter alarm 600 or 1200 running hours factory set 1200 hours With electrical heater post ventilation e With Air sensor in the air intake destratification function CEL only Compatibility table Thermostats Valves Heaters Parallel connection Water sensor Minimum temperature thermostat Factory fitted thermostat built in Valves for 2 pipes Valves for 4 pipes J3A2 2p J3AM 2p J3A2 4p 4p 5100 Fan speed selector CMLOO Thermostat with manual fan speed and S W change over Thermostat with manual fan speed dead band CELOO automatic change over Thermostat with automatic fan speed dead band CEL20 automatic change over CEL30 Thermostat with automatic fan speed dead band automatic change over for modulating valve Remote controllers and thermostats wall mounted Par