1. YAMAHA DIGITAL MIXING CONSOLE PM5D V1 05 Supplementary Manual PM5D system software V1 05 includes the following changes and additions relative to V1 04 Use ENCODER ON keys to turn phantom power 48V on off A USE ENCODER ON AS 48V option has been added to the PREFERENCE 1 screen If this option is on and HA head amp input sensitivity is selected as the encoder mode you can use the ENCODER ON key located above each encoder to turn phantom power supply 48V on off Switch parameter value indication on off in the Name display A CHANNEL NAME NUMERIC DISPLAY field has been added to the PREFERENCE 2 screen In V1 04 and earlier operating the fader or encoder pan setting of each channel caused the name display to show the value of that parameter In V1 05 turning the ENCODER VALUE and FADER VALUE options off will prevent the respective parameter value from appearing when you operate the fader or encoder BRIGHTNESS UPPER PART DISPLAY SOFTWARE VERSION PANEL UNITY POINT OFF ee es SYSTEM VERSION v1 00 PANEL ASSISTANCE OFF PANEL BRIGHTNESS 5 NAME DISPLAY LCD LCD BRIGHTNESS HIGH MAIN ELDI LCD BACK LIGHT HIGH PORT Omp MAIN CPRI TRACK PAD MOUSE WARNING DISPLAY TRACK PAD TAPPING DISABLE TIME CODE DROP MOVING SPEED SLOW DIGITAL 1 0 ERROR pa a MIDI I 0 ERROR AD IN41 48 AD STIN SCREEN TIPS CHANNEL NAME NUMERIC DISPLAY SHOW SCREEN TIPS EN
2. CODER VALUE FADER VALUE Select the monitor source from the panel When selecting a monitor source from the panel in V1 04 or earlier you could simultaneously select one source from 2TR Al 2TR D3 or DEFINE and one source from STEREO A STEREO B including LCR for a maximum total of two sources In V1 05 turning on one key will turn off the other keys allowing you to select a single monitor source more rapidly If you want to select two sources simultaneously as in V1 04 and earlier press the corresponding panel keys simultaneously or use the MONITOR screen HA follows Recall Safe on off operations A new SAFE KEY MODE SELECT section has been added to the RECALL SAFE screen If you turn on the HA CH button using the RECALL SAFE key of the panel or the RECALL SAFE button in the CH VIEW screen INPUT VIEW function to turn Recall Safe on off will now also turn on off the Recall Safe setting for the HA patched to the corresponding channel If the CH button is on the HA Recall Safe setting will not be linked ii MA RECALL SAFE KNA AA ao ese OUTPUT SAFE PARAMETERS OTHER SAFE PARAMETERS i D gt l r m f l 1 m fa 7 m br TRX SAFE SAFE ON OFF ON OFF amp D mm pa jaza EA 3 EE 4 4 ae as 6 6 oa a aa EA 3 4 Ee 6 8 Em 10 era ral MUTE MASTER MUTE_MASTER MIDI REMOTE fat pic op B a z PLUG IN ajea 4 x _
3. appear letting you Select the DME series unit monitor source If the MONITOR button is on the EXTERNAL CUE indicator in the upper part of the display will turn on and the monitor signal of the DME series unit will be sent to the PM5D s CUE bus a ere JET gt 001 1 MIDI SETUP MIDI PGM CHANGE MIDI CTRL CHANGE MID SLOT OUTPUT e BENE 018 ors au 1 ee ee oe ee ee Oe A A A a A DELAY DELAY a a a A a aA A AEA A A A A A A O SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE SAMPLE an 6 66 6 80 dB di B dB dB B E E dB UNUM LOM A S LEVEL 5 9 16 LEVEL OFF SELECTED CHI MIKSECTION fi FADER STATUS oh exam a DIRECT RECALL i S USER DEFINED KEY aad BANK A Note Before turning on the MONITOR button you must select the same port as the monitor output on the DME series unit and as the monitor input for the PM5D To specify the DME series unit monitor output use the Monitor Out dialog box of DME Designer accessed by Tools menu gt Monitor To specify the PM5D monitor input use the MONITOR PORT field on the SETUP page of the DME CONTROL screen Newly added bulk dump data types The following data types can now be handled by bulk dump Dataname 512 Surround Setting K tX rx Current Data amp Request 512 User Defined Keys V tX rx Current Data amp Request 52 MIDI Remote amp G tX rXx Current D
4. ata Request 512 Fader Mode amp U tx rx Current Data Request SETUP data compatibility SETUP data created on system software V1 05 or later cannot be loaded into a system that s running V1 03 or earlier However SETUP data created on system software V1 03 or earlier can be loaded by a system that s running V1 05 or later A note regarding scenes libraries immediately after system startup After the system is started up the PM5D takes several minutes to transfer scene library data within internal memory The time required depends on the amount of data This means that the following restrictions apply during this time e You can t execute the PASTE button in the GLOBAL PASTE screen e You can t execute the scene memory UNDO function e Scene memory recall will take a bit of time U R G Pro Audio amp Digital Musical Instrument Division Yamaha Corporation 2004 Yamaha Corporation
5. x o a a E m El E E a m E a m a a E SET ALL j CLEAR ALL i E sees CLEAR ALL AMM ae CLEAR ALL CME DCA group name Recall Safe and Selective Recall can be switched on off A new WITH NAME button has been added to the DCA area of the RECALL SAFE screen and SELECTIVE RECALL screen This allows you to exclude just the DCA group name from DCA group Recall Safe and Selective Recall If the WITH NAME button is on Recall Safe and Selective Recall will apply to the DCA group names of DCA groups for which these functions are on If the WITH NAME button is off DCA group names are excluded from Recall Safe and Selective Recall PLUG IN parameters added to Recall Safe and Selective Recall PLUG IN parameters have been added to the RECALL SAFE screen and SELECTIVE RECALL screen This is to support plug in cards such as Waves Y96K that will become available in the future MIDI EVENT etc data now maintained during scene recall The MIDI EVENT GPI OUT CONTROL and REMOTE TRANSPORT data included in a scene is now maintained when a scene recall occurs This means that if you store a recalled scene into another scene this data will be stored as it was when recalled DME series monitor source selection and EXTERNAL CUE on off A MONITOR button and monitor source select button have been added to the DME CONTROL screen When you click the monitor source select button 3 the MONITOR POINT SELECT window will