Home

Yamaha M7CL V3 Upgrade Guide

image

Contents

1. M7CL Upgrade Guide 1 Preparing for the update 1 2 Prepare a USB storage device USB flash memory and a computer with a built in USB connector Save the M7CL internal data to the USB storage device or M7CL Editor compatible with the current firmware version as backup If you are saving the data to the USB storage device open the SAVE LOAD popup window from the SETUP screen IMPORTANT If you update the firmware V1 or V2 to V3 or V3 0x to V3 5x all the internal data will be initialized Make sure to back up the internal data before updating Download the latest firmware of the M7CL from the Yamaha Pro Audio website http www yamahaproaudio com downloads Connect the USB storage device formatted in FAT12 FAT16 FAT32 to the USB connector of your computer For details on the formatting procedure refer to the manual that came with your computer or USB storage device If you are formatting the media on the M7CL refer to the M7CL owner s manual Up to 16GB of the USB storage device is checked for operations If the USB storage device is formatted in M7CL V1 12 or later 4GB or larger media will be formatted in FAT32 and 2GB or less in FAT16 Copy the four files extensions PGM in the m7cl_frm indicates the version number folder extracted from the downloaded file to the root directory of the USB storage device Remove the USB storage device when the files have been copied For more information on removing t
2. YAMAHA M7CL Upgrade Guide This document explains how to update the latest firmware V3 x for the M7CL M7CL 48 M7CL 32 M7CL 48ES and how to update the firmware for the EtherSound module built into the M7CL 48ES Precautions Please be sure to read this section first The user assumes full responsibility for the update If you update the firmware V1 or V2 to V3 or V3 0x to V3 5x all the M7CL internal data will be initialized Make sure to back up the internal data before updating The data saved in a previous version can be loaded into a system in a later version If you fail to follow these instructions properly or turn off the M7CL or remove the USB storage device while the update is in progress the M7CL may be damaged If the M7CL does not work properly after updating and you ve tried updating several times please contact your Yamaha dealer Yamaha Corporation owns exclusive copyrights for the M7CL firmware its update program and this documentation AuviTran owns exclusive copyrights for the EtherSound firmware and its update program Reproducing or modifying all or part of this documentation without permission is strictly prohibited EtherSound is a registered trademark of Digigram S A Windows is a registered trademark of Microsoft Corporation in the United States and other countries The company names and product names in this document are the trademarks or registered trademarks of their respective companies
3. of the agreement then click I Agree The ES Firmware Updater will start up L NOTE If a dialog box enabling you to stop the EtherSound service appears click Yes M7CL Upgrade Guide 5 Network Adapter Selection Device tools Network adapter Realtek PCle GBE Family Controller 100Mbps z Rescan E Show alldevice AuviTran J EtherSound Devices Device Manufacturer Product family Firmware Kemel Status 00 0E 55 03 44 CC Yamaha M7CL 48ES 0x0C18 3 03 No FirmwareUpdater necessary Program Advanced Options Firmware to program Version OX0C18 Keel 3 09 View log PROGRAM Firmware Updater v4 3 Firmware Pack v3 28 API v3 12b 7 For Network adapter in the Settings section select the network adapter for the Ethernet connector that is connected to the M7CL 48ES 8 Check the box to the left of the device description listed in the EtherSound Devices section NOTE If no device is listed click the Refresh button If still no device is listed your computer may not be properly connected to the M7CL 48ES Please make sure that the cable is not disconnected or damaged that you have selected the correct network adapter and that the M7CL 48ES has started in Normal mode 9 Select an appropriate firmware component for Firmware to program in the Program section Select firmware version 0x0C18 or later 10 Click the PROGRAM button in the Program section The u
4. password again If the firmware has been updated from V1 rotate the top panel MONITOR LEVEL knob slightly in either direction since the monitor level has been reset to zero Updating the firmware V3 0x to V3 0x or V3 5x to V3 5x 1 2 7 Turn off the power to the M7CL Connect the USB storage device to the M7CL USB connector then turn on the power to the M7CL A Start Loading message will be displayed Click the OK button to start loading the firmware CAUTION A Loading message will appear during loading the firmware The indication will be displayed during the loading progress Do not disconnect the USB storage device or power off the M7CL while accessing the USB storage device When the firmware has been loaded power off the M7CL remove the USB storage device then turn on the power to the M7CL while holding down the SCENE MEMORY STORE key When an Initialize All Memories message appears press the INITIALIZE button When an Are you sure message appears press the OK button Initializing the internal memory will be started When the initialization is complete press the EXIT button If necessary confirm the firmware was correctly updated in the version field in the SETUP screen This completes the update procedure of the M7CL firmware If you have backed up the necessary data load it using the M7CL SAVE LOAD function or the M7CL Editor compatible with the updat
5. ed firmware version If a password has been set for Administrator set the password again M7CL Upgrade Guide 4 Updating the EtherSound module firmware M7CL 48ES For more information on the ES Firmware Updater the EtherSound firmware update program visit the AuviTran SARL website or refer to the ES Firmware Updater USER S MANUAL installed during the course of this update 1 2 Turn off the power to the M7CL 48ES Double click AVS FirmwareUpdater Setup vx xx exe the update program installer you downloaded from the AuviTran website then follow the instructions on screen to install the program vx xx represents the version number of the ES Firmware Updater NOTE l When running under Windows Vista Windows 7 the User Account Control dialog box may appear Click Continue or Yes You may be prompted to restart the computer after the installation is complete Before proceeding to step 3 restart the computer Connect the EtherSound IN jack on the rear panel of the M7CL 48ES unit to the Ethernet jack on the computer using an Ethernet cable LINK ACT 100 Turn on the power to the M7CL 48ES Select Start All programs AuviTran Firmware Update ES Firmware Updater A license agreement dialog box will appear NOTE When running under Windows Vista Windows 7 the User Account Control dialog box may appear Click Continue or Yes Scroll to the end
6. he USB storage device refer to the owner s manual for your computer and USB storage device In order to update the M7CL 48ES download the latest firmware of the EtherSound module from the AuviTran website http www auvitran com M7CL Upgrade Guide 2 Updating the M7CL firmware IMPORTANT If you intend on downgrading the M7CL 32 48 firmware V3 to V1 or V2 make sure to back up the internal data then initialize the internal memory before updating If you perform the update without initializing operation of the M7CL may halt while a Starting System message is flashing on the lower right of the screen due to the difference in memory structures In this case turn off the power then turn on the power again while holding down the SCENE MEMORY STORE key and A key The internal memory will be forcibly initialized and the M7CL will start up in normal mode in around one minute Updating the firmware V1 or V2 to V3 or V3 0x to V3 5x 1 2 3 4 5 6 7 9 Turn off the power to the M7CL Connect the USB storage device to the M7CL USB connector then turn on the power to the M7CL A Start Loading message will be displayed Click the OK button to start loading the firmware CAUTION A Loading message will appear during loading the firmware The indication will be displayed during the loading progress Do not disconnect the USB storage device or power off the M7CL while acces
7. pdate operation will begin A CAUTION The update will take about 3 minutes During the update operation do not turn off the power to the unit or disconnect the cable If update fails due to disconnection of the power cable during the update or due to other reasons the device may become inoperative 11 When a Success dialog box appears click OK The update is now complete If a dialog box other than Success appears first make sure that the devices are connected properly then close the ES Firmware Updater without turning off the power to the M7CL 48ES Then resume the procedure from step 5 12 Restart the M7CL 48ES M7CL Upgrade Guide 6 13 Click the Refresh button in the Settings section The EtherSound Devices section will display information on the M7CL 48ES that you just restarted 14 Make sure that the firmware version displayed in the EtherSound Devices section matches the firmware version to which you just updated If the version numbers do not match the update operation may have failed Try the update operation again starting from step 8 15 Click Exit The ES Firmware Updater will close The EtherSound module firmware update is now complete Yamaha Corporation All Rights Reserved 2009 2011 Yamaha Corporation EO M7CL Upgrade Guide 7
8. sing the USB storage device When the firmware has been loaded the M7CL automatically restarts and a Starting System message flashes for approximately one minute While this message is flashing do not turn off the power If you have accidentally turned off the power turn on the power again to resume the initialization When a Since M7CL was upgraded Initialize all memories popup window or similar message appears press the CLOSE button to close it When an Initialize All Memories message appears press the INITIALIZE button When an Are you sure message appears press the OK button Initializing the internal memory will be started When the initialization is complete press the EXIT button Remove the USB storage device after confirming the ACCESS indicator has disappeared in the function access area 10 If necessary confirm the firmware was correctly updated in the version field in the SETUP screen Also adjust the detection point of the touch screen Calibration function on the startup menu screen Restart the M7CL first to adjust the faders Calibration function For details refer to the M7CL Upgrade Guide 3 M7CL Owner s Manual This completes the update procedure of the M7CL firmware If you have backed up the necessary data load it using the M7CL SAVE LOAD function or the M7CL Editor compatible with the updated firmware version If a password has been set for Administrator set the