1. ne cessessseseseeseestesseenees 8 1 If the Connection Between SIQA and the Machine is Unsuccessful 00000000011010000 8 2 If the Adjustment Values are not Saved to the MAChING ee eccesssesseesesstesseeseestesseeseen 8 5 If SIQA Cannot Make the Adjustments 00 ccccssssssessssssssesssesessscsnecsessucsssesecsecscssessecssesseeseeses 8 6 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Simple Image Quality Adjustment SIQA Tool Overview When to Use the SIQA Tool Use the SIQA Tool in the following instances e When image alignment on duplex output requires correction e When within page image density requires uniformity adjustment Adjustment Procedure Definitions Auto Alignment Adjustment The Auto Alignment Adjustment procedure allows for correction of image placement between side 1 and side 2 images in duplex output You can store up to 20 alignment adjustment profiles Types for use across all input trays You can assign a different Type to each of the input trays if desired Density Uniformity Adjustment The Density Uniformity Adjustment procedure allows for uniform ink coverage between the inboard and outboard see note below sides of the printed output Unlike Auto Alignment Adjustment the profile you select applies to all input trays Simple Image Quality Adjustment Tool 1 1 Installation and Adjustments Guide SIQA Software Installation Image Orientation Definitions I
2. standalone printer Xerox EX Print Server powered by Fiery standalone Integrated Fiery Color Server SIQA software media The SIQA software either on a USB drive or a DVD The SIQA Black Page PDF files which reside either on the USB drive or the DVD Note The Power Save Mode timer should be set to a minimum of 60 minutes so the machine will not enter Sleep Mode during this procedure Simple Image Quality Adjustment Tool 2 1 Installation and Adjustments Guide SIQA Software Installation Installing the SIQA Tool Software on a PC 2 2 Connect the USB drive or insert the DVD into the target PC On the removable media locate the file SIQA_ENG_v0104 zip or download it from WWW Xerox comM Copy the zip file to PC or server desktop Open the zip file and extract copy the PDF files to the folder location of your choice Note It is recommended that you create a new folder for the extracted files In the folder containing the extracted files locate and double click on the setup exe file Note If prompted to allow the program to make changes to the computer select Yes The screen below may display If it does select Next to continue Ik is strongly recommended that you exit all programs before running this Installer Applications that run in the background such as virus scanning utilities might cause the installer to take longer than average to complete lt lt Back Eent aa Simple Image Qual
3. 9 29 2014 NVIDIA 3D Vision Driver 340 52 NVIDIA Corporation 9 27 2014 aj NVIDIA Graphics Driver 340 52 NVIDIA Corporation 9 27 2014 NVIDIA nView 141 24 NVIDIA Corporation 9 27 2014 nva wmi 2 18 0 NVIDIA Corporation 9 27 2014 m Simple Image Quality Adjustment Fuji Xerox Co Ltd 9 12 2014 lt E m 5 Currently installed programs Total size 81 3 MB g 10 programs installed p 5 At the Programs and Features screen click Yes A Are you sure you want to uninstall Simple Image Quality Adjustment Inthe future do not show me this dialog box 6 At the User Account Control screen click Yes to complete uninstallation 7 8 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Troubleshooting If the Connection Between SIOA and the Machine is Lost Any time the connection between the SIQA Tool and the printer is lost press the C button on the UI twice then Confirm to restore the connection If the connection is not restored do one of the following e Openacommand prompt in Windows and type Ping xxx xxx xxx xxx machine IP address e Go to the Start menu and type Ping xxx xxx xxx xxx machine IP address into the search box then press the Enter key A response indicates communication has been established between the PC and the machine and the following screen displays Simple Image Quality Adjustment Tool 8 1 Installation and Adjustments Guide Troubleshooting If the Connection Bet
4. Adjustment Use the Density Uniformity Adjustment feature to correct image quality on the printed output when that image quality is not consistent throughout the entire print for example the image is lighter or heavier on one side of the print than the other Using the Simple Image Quality Adjustment SIQA Tool you can make adjustments easily and quickly to correct these image quality issues The procedure requires the installation of the SIQA application on a Windows PC Notes If your print server is a Windows based PC the SIQA application may be installed on it otherwise a third party PC is required Contact the Customer Support Center for more information Record the IP address It will be used later in the procedure 1 Atthe machine select Guest No communications with Xerox SMart eSolutions server 2 Guest Contact System Administrator 2 Simple Image Quality Adjustment Tool 6 1 Installation and Adjustments Guide Density Uniformity Adjustment 2 Atthe System Admin Login screen type admin as the Admin s Login ID and select Next 3 Enter 1111 as the password and select Enter 6 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide 4 Press the Machine Status button on the printer s UI Density Uniformity Adjustment 5 Onthe Admin screen select the Tools tab Q Py Service Settings q Connectivity amp Network Setup Pint Service Settings oon Fax Servic
5. Use the down arrow in the Image Quality Adjustment box to select a procedure p im s B e o eee a 2 12 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation Setting Up and Running SIQA Software on a PC via an EX Print Server or Integrated Fiery Color Server 1 Ensure that the cross over Ethernet cable is installed and connected between the print server and the print engine 2 From the print server access and record the IP address of the EFI server 3 From the PC desktop double click the SIQA icon The Input_Communication_Parameters window displays 4 Enter the printer IP address and select OK rr k a eect ariel wr te Simple Image Quality Adjustment Tool 2 13 Installation and Adjustments Guide SIQA Software Installation 5 If necessary enter admin as the key operator ID and then select OK The window below displays indicating that the connection between the SIQA Tool and the machine was successful and that a folder has been created on the print engine hard drive Note To confirm the folder creation go to the printer and select Send from Folder on the home screen and select lt folder 190 gt The newly created folder name is SYSTEM IQ AUTO If the folder does not exist in Send from Folder repeat steps 3 through 5 above Note If the Tool displays the message Failed to communicate with the machine Do you want to try again clic
6. adjustment values A progress indicator screen displays Note If the warning window below displays select Yes and continue to Assigning a Type toa Paper Tray on p 5 18 At the end of the Assigning a Type to a Paper Tray section p 5 18 print some samples for evaluation If they are unacceptable contact Xerox to have the machine serviced Simple Image Quality Adjustment Tool 5 15 Installation and Adjustments Guide 26 Auto Alignment Adjustment From the TypeSelect window do the following a There are 20 Types available for use across all paper trays Select the line Type 1 Type 2 etc up to Type 20 where you want to save the calculated adjustment values as a profile Type lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt lt Available gt b Using the Edit button rename the Type In the example above Type 1 was renamed Tray 1 Xerox 4200 Tabloid Note It is preferable to use a meaningful naming convention for your profiles Suggested elements for naming Types 27 e Input tray number e Mediatype e Media weight e Media size c Select OK to save the name change Sele
7. an EX Print Server 1 Ensure that the cross over Ethernet cable is installed and connected between the EX Print Server and the print engine 2 From the EX Print Server locate the printer IP address by selecting Command Workstation gt Device Center gt General Info 3 Record the print server IP address Printing idle Processing Ide E Command W ori vo File Edit Actions Go Server View Help RVER T9IFOOTT Lo xc J5 IP Address 13 141 41 94 Total Memory Options Packages Manage n Fiery Graphic Arts Package ver 1 Fiery Connectivity with Freeflow Dj Ca 865 3 GB Free 858 8 GB Bene Jobs 62 6 MB 0 6MB8 62 0MB 0 08 System 2 6 GB Tray 6 oversized Booklet maker finisher NA Consumables Toner Levels Black M95 Yellow 10 Magenta SN 100 Cyam a 10 Tray 1 Unassigned 11x17 Uncoated 80 90 gsm SEF Tray 2 Unassigned 13x18 Uncoated 60 90 gsm SEF Tray 3 Unassigned 8 5x11 Uncoated 80 50 gsm SEF A Tray 5 bypass Unassigned 85x11 Uncosted 106 128 gsm LEF Tray 6 oversized Other Waste Toner Container Be 100 Black 1 2 Drum Cartridge GN 92 Yellow Drum Cartridge 63 Magenta Drum Cartridge 63 Cyan Drum Cartridge 63 Fuser Assembly 65 Black 1 Toner Cartridge SM 690 Black 2 Toner Cartridge MM 100 Xerox Unassigned 8 511 Uncoated 80 50 gsm LEF 4 From the print server desktop double cli
8. more information refer Auto Alignment Adjustment on page 5 1 or Density Uniformity Adjustment on page 6 1 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment Use this procedure to correct misalignment of the printed output The Auto Alignment Adjustment uses an application called Simple Image Quality Adjustment SIQA and it allows the user to make adjustments easily and quickly and to correct any misalignment on the printed output The procedure requires the installation of the SIQA application on a Windows PC Notes If your print server is a Windows based PC the SIQA application may be installed on it otherwise a third party PC is required Contact the Customer Support Center for more information This procedure also requires the black background pattern file which is located in the SIQA install folder Record the IP address It will be used later in the procedure Performing Auto Alignment Adjustment 1 Goto the machine UI and select the Guest button to enter administrator mode from home page screen Simple Image Quality Adjustment Tool 5 1 Installation and Adjustments Guide Auto Alignment Adjustment The System Administration Login screen displays 2 Type admin as the Admin s Login ID and select Next 5 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 3 Enter 1111 as the password and selec
9. 1 Install the SIQA Tool Refer to Installing the SIQA Tool Software on a PC on page 2 2 2 Obtain the IP address from the EFI Bustle or Standalone from the EX I Fiery Color Server configuration sheet 3 Launch the SIQA tool 4 Enter the IP address and then select OK Simple Image Quality Adjustment Tool 3 1 Installation and Adjustments Guide Accessing C60 C70 SIQA Through EFI Bustle and Standalone 5 Enter admin as the Machine Administrator s ID and select OK 6 Click OK at the Message screen 3 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Accessing C60 C70 SIQA Through EFI Bustle and Standalone 7 The main SIQA window displays The Auto Alignment Adjustment and or Density Uniformity Adjustment procedures are now available Use the down arrow in the Image Quality Adjustment box to select a procedure For more information refer to Auto Alignment Adjustment on page 5 1 or Density Uniformity Adjustment on page 6 1 Simple Image Quality Adjustment Tool 3 3 Installation and Adjustments Guide 3 4 Accessing C60 C70 SIQA Through EFI Bustle and Standalone Simple Image Quality Adjustment Tool Installation and Adjustments Guide Accessing C60 C 0 SIQA Through FFPS Bustle The Simple Image Quality Adjustment SIQA Tool is already installed on the FFPS Use Remote Desktop to access the SIQA Tool System Requirements A client PC with one of the following
10. 2 Close the Document Feeder Cover and select Start Note Perform scanning twice in the order of the chart number by inverting the chart and repeating it for the reverse side To cancel Alignment Adjustment select Cancel Scan Page s 0 17 If you selected multiple sample sheets in step 13 repeat the scanning process steps 15 and 16 for each sample sheet When all sample sheets have been scanned continue to step 18 18 After scanning four times per sample sheet select Scan Complete A i Alir Tr E F F TT E Auto Alignment Adjustment ad 7 pug miii i P Sores jj 1 a lj gt e N a TP m oak i H M i gt aa i t a 2 i a i 1 Place the Calibration Chart and background plate on the T 1f r a ka E aT o E a Petar aie Si Bove ene i Document as shown ji TS oi UI aaia oo 2 Close the Document Feeder Cover and select Start Note Perform scanning twice in the order of the chart number by inverting the chart and repeating it for the reverse side To end Alignment Adjustment select Scan Complete Simple Image Quality Adjustment Tool 5 11 Installation and Adjustments Guide Auto Alignment Adjustment 19 Follow the instructions on the screen and select Confirm to exit 20 Go to the PC where SIQA was installed and double click the shortcut you created see p 2 6 to open the SIQA Tool application Note If the SIQA application fails to launch refer to the Problem Solv
11. 61 E Microsoft Visual C 2010 86 Redistributable 10 0 Microsoft Corporation Esap Business Explorer SAP AG E Simple Image Quality Adjustment Fuji Xerox Co Ltd 9 73MB 104 el ONICS tal A slerome OIU V lt kal Currently installed programs Total size 1 29 GB 47 programs installed 4 Click Uninstall on gO fel gt Control Panel gt Programs Programs and Features Search Programs and Features O T c z ontrol P z a oaa Uninstall or change a program View installed updates To uninstall a program select it from the list and then click Uninstall Change or Repair Turn Windows features on or Organize v f Uninstan E Name Install a program from the oa Publisher i Version E Adobe AIR Adobe Systems Inc 2 5 1 17730 E Adobe Community Help Adobe Systems Incorporated 34 980 BB Adobe Flash Player 14 ActiveX Adobe Systems Incorporated 14 0 0 145 E Adobe Flash Player 14 Plugin Adobe Systems Incorporated 14 0 0145 BB Adobe Reader XI 11 0 07 MUI Adobe Systems Incorporated 11 0 07 AFileZilla Client 3 7 4 1 Tim Kosse 3741 FF DT Audio DT 1 0 6388 0 E9 Intel R Network Connections Drivers Intel 161 Java 7 Update 60 Oracle 7 0 600 Java TM 6 Update 45 Oracle 6 0 450 WB Microsoft NET Framework 4 Client Profile Microsoft Corporation 4 0 30319 B Microsoft NET Framework 4 Extended Microsoft Corporation 4 0 30319 a Microsoft
12. GROUP II 0k cancel Note If the Remote Desktop Connection screen displays mark the checkbox labeled Don t ask me again for connecting to this computer and click Yes For convenience create a shortcut to the SIQA Tool on the FFPS desktop a Windows Vista 7 i From the Start menu select All Programs gt Simple Image Quality Adjustment gt SIQA ii Drag the SIQA icon to the desktop to create the shortcut Simple Image Quality Adjustment Tool Installation and Adjustments Guide Accessing C60 amp C70 SIQA Through FFPS Bustle b Windows 8 1 i Press the Windows key H and the Q key simultaneously ii Type SIQA in the search box iii Select the SIQA file from the results and select Open file location from the options at the bottom of the screen iv Right click on the file and select Send to gt Desktop create shortcut 5 Open the SIQA Tool using the shortcut you just created 6 Enter 100 100 100 101 and select OK 100 100 100 101 7 Enter admin as the Machine Administrator s ID and select OK Simple Image Quality Adjustment Tool 4 3 Installation and Adjustments Guide g 4 4 Accessing C60 amp C70 SIQA Through FFPS Bustle The main SIQA window displays The Auto Alignment Adjustment and or Density Uniformity Adjustment procedures are now available Use the down arrow in the Image Quality Adjustment box to select a procedure For
13. October 2014 xe OX e Xerox Color C60 C70 Printer Simple Image Quality Adjustment Tool Installation and Adjustments Guide m 2014 Xerox Corporation All rights reserved Xerox and Xerox and Design are trademarks of Xerox Corporation in the United States and or other countries BR10941 Freeflow is a trademark of Xerox Corporation in the United States and or other countries Product status build status and or specifications are subject to change without notice Microsoft Windows Windows XP Windows Vista Internet Explorer and Word are registered trademarks of Microsoft Corporation in the United States and or other countries Fiery and PrintMe are registered trademarks of Electronics For Imaging Inc GBC and AdvancedPunch are trademarks or registered trademarks of General Binding Corporation Document Version 1 1 October 2014 1 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Table of Contents 1 Simple Image Quality Adjustment SIQA Tool Overview 1 1 When to Use the SIQA TO GM iscteticiiseccscecsahineidstcsbedswadassdscedcuetesdossdssibeattuolaseucsplaaatdectavescbecgenaguedcmeendonaan 1 1 Adjustment Procedure Definitions occ ccccsssssssssessessecssssseesscsssssessscsesssessecsecssessecsecsseeseeseesees 1 1 Auto Alignment Adjustment 0 ccc essssssesesscsscsscsscssesseesecsscseessesseseesecsessecsecsscssessesssseaseeses 1 1 Density Unifo
14. Office Communicator 2007 Microsoft Corporation 2 0 6362 211 a Microsoft Office Communicator 2007 MUI Microsoft Corporation 2 0 6362 0 83 Microsoft Office Professional Plus 2010 Microsoft Corporation 14 0 7015 1000 E Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 61001 Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 56336 E Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 59193 E Microsoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 9 0 30729 4148 E Microsoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 9 0 30729 6161 E Microsoft Visual C 2010 86 Redistributable 10 0 Microsoft Corporation 10 0 40219 KEE SAP Business Explorer SAP AG 7 0 sap GUI for Windows 7 30 _ SAP _ 7 30 Compilation E Simple Image Quality Adjustment E E r e ae 73M8 104 7 ST Microelectronics 3 Axis Digital Accelerometer Solu ST Microelectronics 4 10 0030 lt m kal Currently installed programs Total size 1 29 GB 47 programs installed Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 6 7 4 Uninstalling the SIQA Tool At the Programs and Features screen click Yes D Are you sure you want to uninstall Simple Image Quality Adjustment In the future do not show me this dialog box No _ 4 The Windows Installer screen displays Windows Installer At the User A
15. Supply 8 511 Plain Auto Detect 8 5x 11 Plain hit Auto Detect 8 5x 11 _ Plain Notes This adjustment must be performed using only A3 or Tabloid 11 x 17 paper Only one profile may be created which will be used for all paper trays so it is recommended to use the most frequently used paper tray for this adjustment 6 6 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity Adjustment 4 Select Print to produce the test pattern prints The two test patterns print Simple Image Quality Adjustment Tool 6 7 Installation and Adjustments Guide Density Uniformity Adjustment 5 Place the CMYK sheet onto the platen glass according to the on screen instructions and select Scan Scan Page s 0 2 6 Place the RGB amp 3CK sheet onto the platen glass according to the instruction on the UI and select Scan 7 Follow the on screen instructions and select Confirm 8 Goto the PC where SIQA was installed and double click the shortcut you created see p 2 6 to open the SIQA Tool application Note If the SIQA application fails to launch refer to the Problem Solving chapter in the System Administration Guide 6 8 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity Adjustment 9 Enter admin as the key operator ID and select OK The Simple Image Quality Adjustment screen displays 10 Sel
16. assasssssnssssssesscacassusssesecassacsnssnceseaseasees 3 1 POC 216 U 6 eae ener nen enn ey ne ne 3 1 4 Accessing C60 C70 SIQA Through FFPS Bustle 0 eects 4 1 NV RO UOO a A E IEE E E 4 1 PrO GOUTE cece cte sce ceouscecceecces coe ocouce cece peencg seca se ccccncos cessed cancossosvescescteucds kcesteusecssesncoeccasactactcossesses 4 1 5 Auto Alignment AE STANT I tcp caastteaceniysassandorreneipinertcmeninunsmreeeinenean 5 1 Performing Auto Alignment Adjustment u ccc ecsesssesseesessesseesecssessecsecssesseesecsecsscssesseesseeseenees 5 1 Assigning a Type to a Paper TOY cccccecccccsssssessessesssssssssessessessesscsscsssseesesscsussessesseesecseeseeseseeseenes 5 18 Modifying a Typo eecceccecsesssesssssssssessssscssessecsscssessessucssecsessecsucssesscsucssssscsucessssscsecsuessecsecsuessecsecsseeseeseesees 5 21 Deleting Ko m BI oE 5 23 6 Density Uniformity Adjustment oo cc cseseesesscsseseeseeseesestesseseeseeeen 6 1 7 Uninstalling the SIQA Tool oo cccsssecsessessssessesscssesecsessessesseseeseesee 7 1 Simple Image Quality Adjustment Tool iii Installation and Adjustments Guide Table of Contents iv Uninstalling the SIQA Tool Using Windows Vista 7 ccccssssssssssssssecsssssssssssecesssseesssssssseeeee 7 1 Uninstalling the SIQA Tool Using Windows 8 1 c eescssssssssssssssecssscssssseececssssssesssssssseeessssesessseessee 7 5 figs ie lls gis ied ga scassi 8 1 If the Connection Between SIQA and the Machine is LOSt
17. ccount Control screen click Yes to complete uninstallation Simple Image Quality Adjustment Tool Installation and Adjustments Guide Uninstalling the SIQA Tool 1 Open the Control Panel a Right click anywhere on the Start screen background ae M Washington DIC Mostly Cloudy Today 78 63 Cloudy Tomorrow 80 60 Partly Cloudy b _ Washington DIC Mostly Cloudy Today 78 63 Cloudy Tomorrow 80 60 Partly Goudy E fano 3 Simple Image Quality Adjustment Tool 7 5 Installation and Adjustments Guide Uninstalling the SIQA Tool The Apps screen displays Reading List EPSON Si Gis Microsoft Mra wW Microsoft Ofice 20 P Microsoft Ofice Ace QP Health amp Fitness WD Character Map Help Tips Reader 7 Math Input Panel c Scroll to the right on the Apps screen to locate the Windows System section d Select Control Panel X Rite ay On Screen Keyboard Density Checker 2 0 2 Windows Speech Recognition P Density Checker User Guide N soft Office Windows System e 2007 Language r WIT Ce ACCESS UU Defa fault Programs fice Diagnostics teps Recorder Ace Excel 2007 ticky Notes File Explorer fice Picture Manager 4 Windows Fax and Scan Help and Support oF E e PowerPoint 2007 Windows Journal Run ft Office Publisher 2007 f Windows Media Player Task Manager a fice Word 2007 WordPad d Hie ef XPS V
18. ch you want to perform the alignment adjustment and then select Save 11x17 8 5x 11 8 5x 11 8 5x11 Plain _ Plain Plain _ Plain Aamin Auto Detect Auto Detect Auto Detect 12 Select a number between 1 and 10 for image area coverage for a typical print job for side 1 and side 2 Refer to the table below to help you choose appropriate coverage values Note Area coverage can be one of the factors that changes the alignment To adjust a specific area coverage level set a value from 1 to 10 Set higher values for heavier area coverage However for most cases setting the value to 1 is adequate You can also select different settings for side 1 and side 2 if the area coverage is heavier on one side than the other Coverage Value Area Coverage Reference Low Area Coverage text only Medium Area Coverage equal mixture of text and graphic images High Area Coverage entire page is primarily graphic images 5 7 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 13 Select the number of sample sheets you want to use Note With multiple samples the software uses the average volume for the adjustment This means that the variation between the sheets is reduced kha ee a uto Augonment Adjustmeni 14 Select Print Anuta Alianmant Aditictmant Ito Augnment Aaqjustment 5 8 Simple Image Quality Adjustment Tool Installat
19. ck the SIQA icon The Input_Communication_Parameters window displays 5 If necessary enter the printer IP address and then select OK Brottomncio Ran BE _ IP Address or FQDN 13 141 41 73 Enter the IP Address or FQDN and Port Number Note Communication with the machine will fail if it is encrypted Simple Image Quality Adjustment Tool Installation and Adjustments Guide 2 10 SIQA Software Installation The Input_Key_Operator_ID window displays 1 Inpu 6 Enter admin as the key operator ID and select OK The window below displays indicating that the connection between the SIQA Tool and the machine was successful and that a folder has been created on the print engine hard drive Note To confirm the folder creation go to the printer and select Send from Folder on the home screen and select lt folder 190 gt The newly created folder name is SYSTEM IQ AUTO If the folder does not exist in Send from Folder repeat steps 4 through 6 above Simple Image Quality Adjustment Tool 2 11 Installation and Adjustments Guide SIQA Software Installation Note If the Tool displays the message Failed to communicate with the machine Do you want to try again click No and follow the instructions in If the Connection Between SIQA and the Machine is on page 8 1 7 Select OK The main SIQA window displays The Auto Alignment Adjustment and or Density Uniformity Adjustment procedures are now available
20. ct OK at the TypeSelect window Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 28 Select Yes to save the new adjustment value to the selected Type The message Adjustment has been successfully completed displays 29 Click OK Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 17 Auto Alignment Adjustment Assigning a Type to a Paper Tray Note If the warning screen in step O displayed print some samples before continuing If they are unacceptable contact Xerox to have the machine serviced 30 At the printer access the Alignment Adjustment Setup screen Note If the machine is out of Tools mode repeat steps 1 to 9 on p 5 1 31 Select Manual Alignment Adjustment 32 Select Alignment Adjustment Type Setup and then select Change Settings Admin 2 Alignment Adjustment Setup Current Value a 2 Tray1 Default Value wij lieis i i ettings 5 18 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 33 Select a paper tray and then select Change Settings x Alignment Adjustment Setup Current Value 1 Alignment Adjust Type Setup Default Value Default Value 5 Tray 4 Default Value 6 Tray5 Default Value 34 Select a Type from the list and then select Save Select Adjustment Type for this tray 2 Al
21. dates To uninstall a program select it from the list and then click Uninstall Change or Repair Turn Windows features on or an Organize v Ai Name amp 2 2007 Microsoft Office system E Density Checker 2 0 DIEPSON Scan m IQAFv6 National Instruments Software Bnvioia 3D Vision Driver 340 52 Bnvioia Graphics Driver 340 52 NVIDIA nView 141 24 NVIDIA WIVI AI Publisher Installed On Microsoft Corporation 6 27 2014 X Rite 7 21 2014 6 26 2014 Xerox 7 11 2014 National Instruments 9 29 2014 NVIDIA Corporation 9 27 2014 NVIDIA Corporation 9 27 2014 NVIDIA Corporation 9 27 2014 NVIDIA j 014 E Simple Image Quality Adjustment Fuji Xerox Co Ltd 9 29 2014 Currently installed programs Total size 10 programs installed Simple Image Quality Adjustment Tool Installation and Adjustments Guide Uninstalling the SIQA Tool 4 Click Uninstall y gt Control Panel gt Programs Programs and Features vi G Search Programs and Features File Edit View Tools Help Control Panel Home s Uninstall or change a program View installed updates To uninstall a program select it from the list and then click Uninstall Change or Repair Turn Windows features on or A Name Publisher Installed On G3 2007 Microsoft Office system Microsoft Corporation 6 27 2014 E Density Checker 2 0 X Rite 7 21 2014 JEPSON Scan 6 26 2014 IQAFv6 Xerox 7 11 2014 National Instruments Software National Instruments
22. e Settings E mail Service Settings IJO Ni l h ti l Ht iw t i ier EN Simple Image Quality Adjustment Tool Installation and Adjustments Guide Power Saver Settings h Screen Button Settings Paper Tray Settings Image Quality Adjustment 6 3 Density Uniformity Adjustment 6 Scroll down the Features group and select Maintenance Admin Select an option The device will be rebooted upon completion of certain sele Force Annotation Y Print Universal Unique ID 7 On the Maintenance screen touch the Scroll Down button to display Page 2 Vaintenance 6 4 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity Adjustment 8 Select Density Uniformity Adjustment UFIULGUIE LAS 1 Atthe Density Uniformity Adjustment screen select Semi Auto Process Using Scanner Density Uniformity Adjustment Note If Invalid operation displays it means that the SYSTEM IQ AUTO folder was not created during SIQA installation Repeat steps 4 through 6 on p 2 10 Simple Image Quality Adjustment Tool 6 5 Installation and Adjustments Guide Density Uniformity Adjustment 2 Select Paper Supply The Calibration Chart will be printed Select the Paper Size and press Print Semi Auto Process Using Scanner 3 Select a frequently used tray loaded with A3 or Tabloid 11 x 17 size paper and select Save Paper
23. e the Adjustments If the screen below displays it is possible that the Type already exists 1 Click OK 2 Atthe printer delete the Type Refer to Modifying a Type on p 5 21 3 Power down the machine and then power it back on 4 Repeat the procedure beginning on p 5 1 8 6 Simple Image Quality Adjustment Tool Installation and Adjustments Guide
24. ect Density Uniformity Adjustment from the Image Quality Adjustment menu and then select Start age Qu ality Adjustment i ea m ee r i n e Me Simple Image Quality Adjustment Tool 6 9 Installation and Adjustments Guide Density Uniformity Adjustment 11 At the Input Address window confirm or enter the machine s IP Address and then click OK 12 Note If the Open File Security Warning window displays click Run Open File Security Warning The publisher could not be verified Are you sure you want to run this software A Name C SIQA SIOA_InProgressBar exe Publisher Unknown Publisher a Application om C SIQA SIOA InProgressBar exe Always ask before opening this file This file does not have a valid digital signature that verifies its publisher You should only run software from publishers you trust How can decide what software to mun Select Yes to save the adjustment values The SIQA application accesses and reads the scanned image data from the printer folder Mail Box analyzes the data and automatically calculates the adjustment values hot Select A progress indicator screen displays 13 Review the information displayed on the Correction_Result screen This screen displays after the analysis and calculation processes have completed The Correction Result information displays the possible improvement to correct inboard to ou
25. ect Restart Otherwise go to step 13 12 If you restarted the PC enter a username and password if required 13 Create a shortcut to the SIQA Tool on the PC desktop a Windows Vista 7 i From the Start menu select All Programs gt Simple Image Quality Adjustment gt SIQA ii Drag the SIQA icon to the desktop to create the shortcut b Windows 8 1 l apen i Press the Windows key gg and the Q key simultaneously ii Type SIQA in the search box iii Select the SIQA file from the results and select Open file location from the options at the bottom of the screen iv Right click on the file and select Send to gt Desktop create shortcut 2 6 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation Printing the SIQA Black Paper Image File The SIQA Black Paper image files must be printed before using the Auto Alignment Adjustment procedure These files are located on the CD ROM or DVD ROM or you may download them from WWWw xerox com 1 Open the PDF file SIQA Black Paper for Adjustment A3 pdf or SIQA Black Paper for Adjustment Tabloid pdf 2 Using duplex mode print the image onto A3 or tabloid 11 x17 paper with a media weight of 105 gsm or 163 gsm The printed output appears as follows Tabloid 11 x17 Side 1 Side 2 Side 1 Side 2 Simple Image Quality Adjustment Tool 2 7 Installatio
26. ect it from the list and then click Uninstall Change or Repair 9 Turn Windows features on or off Install a program from the network itii jz Name Publisher i Version EB Adobe AIR Adobe Systems Inc 2 5 1 17730 E Adobe Community Help Adobe Systems Incorporated 34 980 OB Adobe Flash Player 14 Activex Adobe Systems Incorporated 14 0 0 145 OB Adobe Flash Player 14 Plugin Adobe Systems Incorporated 14 0 0145 BB Adobe Reader XI 11 0 07 MUI Adobe Systems Incorporated 11 0 07 A FileZilla Client 3 7 41 Tim Kosse 3741 BHT Audio DT 1 0 6388 0 E9 Intel R Network Connections Drivers Intel 161 S Java 7 Update 60 Oracle 7 0 600 Java TM 6 Update 45 Oracle 6 0 450 UB Microsoft NET Framework 4 Client Profile Microsoft Corporation 4 0 30319 gB Microsoft NET Framework 4 Extended Microsoft Corporation 4 0 30319 E Microsoft Office Communicator 2007 Microsoft Corporation 2 0 6362 211 a Microsoft Office Communicator 2007 MUI Microsoft Corporation 2 0 6362 0 83 Microsoft Office Professional Plus 2010 Microsoft Corporation 14 0 7015 1000 Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 61001 Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 56336 E Microsoft Visual C 2005 Redistributable Microsoft Corporation 8 0 59193 m Microsoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 9 0 30729 4148 E Microsoft Visual C 2008 Redistributable x86 9 0 3 Microsoft Corporation 9 0 30729 61
27. ide Density Uniformity Adjustment 6 14 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Uninstalling the SIQA Tool Uninstalling the SIQA Tool Using Windows Vista 7 1 From the Windows Start menu select Control Panel Docu t A By Character Map ocuments Pictures Control Panel Music l Microsoft Word 2010 Computer Adobe Acrobat X Pro Control Panel k Devices and Printers Default Programs Help and Support Adobe Acrobat Distiller X E Snipping Tool Yi Workrawe Calculator All Programs a ms Search programs and files Shut down Simple Image Quality Adjustment Tool Installation and Adjustments Guide 7 1 2 7 2 Uninstalling the SIQA Tool Depending on the way you have Windows folder options configured do one of the following In the Programs section select Uninstall a program gO F gt Control Panel gt S ee el Search Control Panel v SoS ESSE Adjust your computer s settings System and Security Review your computer s status Back up your computer Find and fix problems _ Network and Internet View network status and tasks Choose homegroup and sharing options Hardware and Sound View devices and printers View by Category User Accounts fa Change account type Appearance and Personalization Change the theme Change desktop background Adjust screen resolution Clock Language and Region Cha
28. iewer ys Accessones Calculator ia Windows Ease of Access H Character Map Aa Magnifier ay Math Input Panel Narrator pu i Simple Image Quality Adjustment Tool Installation and Adjustments Guide Uninstalling the SIQA Tool 2 Select Programs and Features or select Uninstall a program from the Programs section Tt fe gt Control Panel gt File Edit View Tools Help Adjust your computer s settings System and Security Review your computer s status Save backup copies of your files with File History Find and fix problems _ Network and Internet i View network status and tasks Choose homegroup and sharing options Hardware and Sound View devices and printers Add a device Programs K Uninstall a program v Search Control Panel View by Category User Accounts and Family Safety fa Change account type fa Set up Family Safety for any user Appearance and Personalization Change the theme Change desktop background Adjust screen resolution Clock Language and Region Add a language Change input methods Change date time or number formats Ease of Access Let Windows suggest settings Optimize visual display 3 Locate and select Simple Image Quality Adjustment EY gt Control Panel Programs Programs and Features File Edit View Tools Help Control Panel Home r Uninstall or change a program v G Search Programs and Features View installed up
29. ignment Adjustment Setup Tray 1 Type 2 lt Available gt Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 19 Auto Alignment Adjustment The Type is now assigned to the paper tray selected in step 33 2 Alignment Adjustment Setup Current Value 3 Tray 2 Default Value 4 Tray3 Default Value 5 Tray4 Default Value 6 Tray Default Value Change Settings 35 Select Close three times to exit and then log out of Admin mode 2 Alignment Adjustment Setup le ats j Item Current Value 1 Alignment Adjust Type Setup 3 Tray2 Default Value 4 Tray3 Default Value 5 Tray 4 Default Value 6 Tray5 Default Value 5 Note To add more Types repeat steps 9 through 35 5 20 Change Settings Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment Modifying a Type 1 From the Alignment Adjustment Type Setup screen select the Type you wish to modify Note If the machine is out of Tools mode repeat steps 1 to 9 on p 5 1 Choose an item and select Change Settings gt Alignment Adjustment Type Setup Current Value lt Available gt lt Available gt lt Available gt lt Available gt Change Settings lt Available gt 2 Select Change Settings Choose an item and select Change Setting
30. ing chapter in the System Administration Guide 21 Enter admin as the key operator ID and select OK The Simple Image Quality Adjustment screen displays 5 12 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 22 Select Alignment Adjustment from the Image Quality Adjustment menu and then select Start Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 23 At the Input Address window confirm or enter the machine s IP Address and then click OK Note If the Open File Security Warning window displays click Run The publisher could not be verified Are you sure you want to run this software Name C SIQA SIQA InProgressBar exe Publisher Unknown Publisher Type Application From SIQA SIQA_InProgressBar exe This file does not have a valid digital signature that verifies its publisher You should only run software from publishers you trust How can decide what software to run 24 If the screen below displays select Yes to proceed using the currently applied Type or select No to choose a different Type 5 14 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 25 Select Yes to save the adjustment values The SIQA application accesses and reads the scanned image data from the printer folder Mail Box analyzes the data and automatically calculates the
31. ion and Adjustments Guide Auto Alignment Adjustment The sample sheet prints In the example below the coverage value was set to 1 for both sides Auto Alignment Adjustment Test Print Side A Auto Alignment Adjustment Test Print Side B One black square One gray square Two black squares Two gray squares 15 To correct the misalignment scan each of the four sides of sample chart lead edge and trail edge for each front and back side Follow the instructions on the Auto Alignment Adjustment screen Note You may scan the sides of the sample sheet in any order a Place the sample print onto the document glass shown in step 1 on the image below Side 1 of black paper Refer to p 2 7 for printing instructions Simple Image Quality Adjustment Tool 5 9 Installation and Adjustments Guide Auto Alignment Adjustment Important e The sample sheet must not be placed against the registration edge 20 mm minimum clearance and not skewed more than 15 degrees e Ensure that there is space between the document glass edge and the test pattern b Cover the sample sheet with the black paper and align the white mark with the black or gray sample sheet mark as shown below 5 10 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 16 Select Scan Auto Alignment Adjustment libel are st ee ea AM b pire A DR U ae ni i TNE TET i o n f bi Ha at
32. ity Adjustment Tool Installation and Adjustments Guide SIQA Software Installation 6 Click Next to accept the default destination directory LY Simple Image Quality Adjustment Destination Directory Select the primary installation directory All software will be installed in the following locations To install software into a different locations click the Browse button and select another directory Directory for Simple Image Luality Adjustment Directory for National Instruments products C Program Files National Instruments 7 Atthe License Agreement screen select I accept the License Agreement s radio button and then select Next J Simple Image Quality Adjustment License Agreement Tou must accept the licenses displayed below to proceed lt lt License Agreement gt gt 1 PROPRIETARY RIGHTS Title ownership rights and intellectual property rights in E the SOFTWARE shall remain in Xerox Corporation and or its licensors You have no rights in the SOFTWARE except as expressly granted in accordance with this agreement LICENSE Under this agreement you are granted a non exclusive license to use the SOFTWARE for the purpose of using with compatible Xerox Corporation products You are not permitted to 1 Assign sublicense sell rent lease convey or transfer the SOFTWARE to any third party by any tangible media such as floppy disk magnetic tape or CD ROM 2 distribute the SOFTWARE on a netw
33. k No and follow the instructions in If the Connection Between SIQA and the Machine is Unsuccessful on page 8 1 2 14 Simple Image Quality Adjustment Tool Installation and Adjustments Guide 6 SIQA Software Installation Select OK The main SIQA window displays The Auto Alignment Adjustment and or Density Uniformity Adjustment procedures are now available Use the down arrow in the Image Quality Adjustment box to select a procedure i E Simte Ineas Quay Asmat O y Simple Image Quality Adjustment Tool 2 15 Installation and Adjustments Guide SIQA Software Installation Setting Up and Running SIQA Software on a PC when a FreeFlow Print Server is Installed 1 Ensure that the hub is installed and that the three Ethernet cables are connected to the following One cable from the wall drop to the hub One cable from the hub to the FreeFlow Print Server One cable from the hub to the print engine 2 At the print engine UI record the machine s IP address by selecting Machine Status gt Machine Information 3 From the PC desktop double click the SIQA icon The Input_Communication_Parameters window displays 4 Enter the printer IP address and select OK iw 13 141 41 73 5 If necessary enter admin as the key operator ID and then select OK 2 16 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation The window below displays indicating that the connec
34. m 6 Perpendicularity Adjusts trapezoid effect on the image e Item 7 Skew Adjusts image position with respect to the paper 7 Select Sample Printout to print a sample to verify the adjustment If the print requires more adjustment then repeat the steps in Performing Auto Alignment Adjustment on p 5 1 8 Exit Tools mode 5 22 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment Deleting a Type 1 From the Alignment Adjustment Type Setup screen select the Type you wish to delete Note If the machine is out of Tools mode repeat steps 1 to 9 on p 5 1 Choose an item and select Change Settings 3 Alignment Adjustment Type Setup Current Value 2 Select Delete lt Available gt lt Available gt lt Available gt lt Available gt Change Settings lt Available gt Choose an item and select Change Settings 3 Alignment Adjustment Type Setup Type 3 Type 4 Current Value 6 Type6 Type 5 Note lt Available gt lt Available gt lt Available gt lt Available gt Change Settings lt Available gt Only one Type may be deleted at a time 3 Exit Tools mode Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 23 Auto Alignment Adjustment 5 24 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity
35. n and Adjustments Guide SIQA Software Installation Setting Up Communication between the SIQA Application and the Print Engine Setting up communication between the SIQA software application and the print engine varies depending on the print server that is attached to the machine and whether or not a third party PC is being used The procedures provided here include how to set up and run the SIQA software on the following Third party PC through DMP Controller EX Print Server Fiery standalone Requires keyboard monitor and mouse options Third party PC via an EX Print Server or an Integrated Fiery Color Server Third party PC when a FreeFlow Print Server is installed Note For more information on connectivity refer to Troubleshooting on page 8 1 Setting Up and Running SIQA Software on a Third Party PC Through DMP Controller 1 2 8 At the print engine UI record the machine s IP address by selecting Machine Status gt Device Information From the PC desktop double click the SIQA icon The Input_Communication_Parameters window displays If necessary enter the printer IP address and then select OK 13 141 41 73 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation The Input_Key_Operator_ID window displays Simple Image Quality Adjustment Tool 2 9 Installation and Adjustments Guide SIQA Software Installation Setting Up and Running SIQA Software on
36. nboard and outboard are as follows Onthe machine inboard refers to the rear of the machine the side farthest from you as you are using the machine and outboard refers to the front the side nearest you Onthe printed output as you hold the sheet with the top facing up inboard refers to the left side of the sheet and outboard refers to the right side The short black line indicates the top of the sheet Top Lead Edge Inboard Outboard 1 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation Important The SIQA software must be installed before the Auto Alignment Adjustment and Density Uniformity Adjustment procedures can be performed The SIQA software installation process consists of the following Installing the SIQA software on a PC Setting up communication between the SIQA software application and the print engine This varies depending on the print server attached to your machine and whether or not a third party PC is being used For more information refer to Setting Up Communication between the SIQA Application and the Print Engine on page 2 8 System Requirements The following requirements must be met before installing the SIQA software A client PC with one of the following supported operating systems Windows Vista SP2 Windows 7 SP1 or Windows 8 1 The SIQA software must be installed on a separate Windows based PC for the following Xerox
37. nge keyboards or other input methods Change display language Add a device Connect to a projector Adjust commonly used mobility settings Uninstall a program et programs w Adjust your computer s settings HomeGroup Intel R Graphics and Media Keyboard Mouse Performance Information and Tools Power Options Recovery RemoteApp and Desktop Connections Sound P L p 4 Le ooye aes Ease of Access Let Windows suggest settings Optimize visual display Select Programs and Features IDT Audio Control Panel Internet Options Location and Other Sensors Network and Sharing Center Personalization Program Download Monitor Region and Language Run Advertised Programs Speech Recognition View by Largeicons amp Indexing Options Notification Area Icons moo amp B Phone and Modem kal Programs and Features W Remote Control W SAP GUI Configuration Sync Center x gt gt E gt Control Panel All Control Panel Items X Search Contro Pane P Simple Image Quality Adjustment Tool Installation and Adjustments Guide Uninstalling the SIQA Tool 3 Locate and select Simple Image Quality Adjustment E lt eee n gO fel gt Control Panel gt Programs Programs and Features p E O __ S_ _ E P e Control Pand Ee Uninstall or change a program View installed updates To uninstall a program sel
38. ork or by a telephone line available to the public or 3 alter modify decompile disassemble reverse engineer or create derivative works based on the whole or anv part of the The software to which this National Instruments license applies i Simple Image Quality Adjustment do not accept the License Agreement Simple Image Quality Adjustment Tool 2 3 Installation and Adjustments Guide SIQA Software Installation The Start Installation window displays La Simple Image Quality Adjustment Start Installation Review the following summary before continuing Adding or Changing e Nl Securty Update 67LELOQW for ce Sdgrph ocx Simple Image Quality Adjustment Files Click the Nest button to begin installation Click the Back button to change the installation settings 8 Click Next to continue A window displays the progress of the installation UT Simple Image Quality Adjustment Overall Progress 622 Complete E B Creating shortcuts a ee 2 4 Simple Image Quality Adjustment Tool Installation and Adjustments Guide SIQA Software Installation 9 Atthe Installation Complete window select Next W Simple Image Quality Adjustment Installation Complete rs ee e E 10 At the Message window select OK Simple Image Quality Adjustment Tool 2 5 Installation and Adjustments Guide SIQA Software Installation 11 If prompted to restart the computer to complete installation sel
39. rmity Adjustment 0 ccc esssssssssessessecssessessscssecseesecsecsseesessecssesseessesseeseeseesees 1 1 Image Orientation DeFINitiONS 0 eccssssessssessessecssessecsecssessecsecscssscsessecsusesscsscssecsecsecseeeseesscses 1 2 2 SIQA Software Installation vissesicssssvsssassicnssieososnsacnersenannaeasvissnsanscnvansebicasrarensnaetl 2 1 System Requirements 1 0 ccecccessessessssssssscsessessessscssssscssessesssssecsssneessessssecsssssssscscsscsscsessessecsucacssesneeseeneesees 2 1 Installing the SIQA Tool Software on qa PC wun ecccccesssessesssessessessecsscssecsecsscssecsecsscssecssesecsscsseenecses 2 2 Printing the SIQA Black Paper Image File ou cecccessssssessessessssssessecsecssessessecssssseesessecsseeseesses 2 7 Setting Up Communication between the SIQA Application and the Print Engine 2 8 Setting Up and Running SIQA Software on a Third Party PC Through DMP CONTON T a e A AE EEA E AEE A 2 8 Setting Up and Running SIQA Software on an EX Print Servet eeecsesseesseeseeees 2 10 Setting Up and Running SIQA Software on a PC via an EX Print Server or Integrated Fiery Color Server ou cecceccsssssssssssssssssscssssssssesscsscssessesssssscsesessessscsscsscscsacsscenceaceass 2 13 Setting Up and Running SIQA Software on a PC when a FreeFlow Print Server is Los AGN sea N T E E E A S 2 16 3 Accessing C60 C70 SIQA Through EFI Bustle and Standalone 3 1 System REQUIFEMENES ccccccccsccescsssssssscsesssssssssssnssscssssessssnssscsec
40. s 3 Alignment Adjustment Type Setup Current Value 2 Type 2 lt Available gt Type 3 lt Available gt 4 Type4 lt Available gt Type 5 lt Available gt 6 Type 6 lt Available gt Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 21 Auto Alignment Adjustment To change the Type name 3 Select Name w Admin Choose an item and select Change Settings 1 Type 1 Current Value ray 1 Xerox 4200 Tabloic Sample ees Printout f 3 Y Print Position Side 1 0 0mm Side 2 0 0mm 2 X Print Position Side 1 0 0mm Side 2 0 0mm 4 X Magnification Width Side 1 0 000 Side 2 0 000 5 Y Magnification Length Side 1 0 000 Side 2 0 000 gt e 6 Perpendicularity Side 1 0 0mm Side 2 0 0mm v i Change Settings 4 Select Change Settings 5 Edit the name as you wish and then select Save 6 Select Sample Printout to print a sample to verify the adjustment To make changes to other elements To make other changes to the adjustment refer to the Alignment Adjustment Procedure in the System Administrator Guide The following items may be modified e Item 2 X Print Position Adjusts X Axis Position Alignment e Item 3 Y Print Position Adjusts Y Axis Position Alignment e Item 4 X Magnification Width Adjusts X Axis True 100 R E e Item 5 Y Magnification Length Adjusts X Axis True 100 R E e Ite
41. supported operating systems e Windows Vista SP2 e Windows 7 SP1 e Windows 8 1 Procedure 1 Enable Remote Desktop on the client PC a Locate the Remote Desktop application at C Windows System32 mstsc exe b Double click mstsc exe to launch the application For information on Remote Desktop refer to http windows microsoft com en us windows connect using remote desktop connection connect usingremote desktop connection windows Simple Image Quality Adjustment Tool 4 1 Installation and Adjustments Guide 2 3 4 2 Accessing C60 amp C70 SIQA Through FFPS Bustle Enter the IP address from the FFPS and click Connect Note The IP address is located on the C60 C70 UI at the bottom of the service screen Ei Remote Desktop Connection Remote Desktop Connection Computer Example computerfabrkam com Username None specified The computer name field is blank Enter a full remote computer name i Show Options At the Windows Security screen do the following a Enter Administrator as the user name a Enter the password you used to set up the FFPS b Click OK Windows Security a s C Your credentials did not work Your system administrator does not allow the use of saved credentials to log on to the remote computer 13 121 95 205 because its identity is not fully verified Please enter new credentials z WORKGROUP Administrator l ser name iz Password Domain WORK
42. t Enter 4 Press the Machine Status button on the printer s UI Simple Image Quality Adjustment Tool Installation and Adjustments Guide 5 3 5 4 6 5 On the Admin screen select the Tools tab COPY Service Settings Y r Connectivity amp Network Setup oPrint Service Settings Select an option he device will be rebooted upon col Auto Alignment Adjustment Settings Unique ID Notify Job Completion 2 by E mail Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 7 On the Maintenance screen touch the Scroll Down button to display Page 2 WETICE 8 Select Alignment Adjustment Admin Maintenance Pa Simple Image Quality Adjustment Tool Installation and Adjustments Guide 3 5 Auto Alignment Adjustment 9 Atthe Alignment Adjustment Setup screen Select Auto Alignment Adjustment Note If Invalid operation displays it means that the SYSTEM IQ AUTO folder was not created during SIQA installation Repeat steps 4 through 6 on p 2 10 10 Select Paper Supply to show the available paper trays A felt AL qe ae 7 Wee ai aii Min iN a es i as arene lial I Tae T ur ni a i er Ay aan Yate al ne rai i ny ih ce ij pj hit a Une MA o Mig ies 5 6 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Auto Alignment Adjustment 11 Select the paper tray for whi
43. tboard density variation Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity Adjustment 14 Select Details TE Correction Result Average Color Difference Maximum Color Difference Estimated Improvement Estimated Improvement 19 Maximum Color Difference and Average Color Difference hawe improved using the Density Uniformity Adjustment Simple Image Quality Adjustment Tool 6 11 Installation and Adjustments Guide Density Uniformity Adjustment The Correction_Parameters screen displays the specifics of the adjustment E Correction_Parameters Initial Adjustment Shape Adjustment Level Rie ET w mee mG gan Press Close to return to the previous screen r Close 15 Select Close twice to exit the Correction_ Parameters and Correction_Result screens 6 12 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Density Uniformity Adjustment 16 Select Yes to save the adjustment values A progress screen displays Important Do not power off the machine while the adjustment values are being saved 17 Upon completion select OK to exit the SIQA application Note If the density uniformity is unacceptable you may repeat the test procedure steps 1 to 17 up to three times to further improve the density uniformity Simple Image Quality Adjustment Tool 6 13 Installation and Adjustments Gu
44. tion between the SIQA Tool and the machine was successful and that a folder has been created on the print engine hard drive Note To confirm the folder creation go to the printer and select Send from Folder on the home screen and select lt folder 190 gt The newly created folder name is SYSTEM IQ AUTO If the folder does not exist in Send from Folder repeat steps 3 through 5 above Note If the Tool displays the message Failed to communicate with the machine Do you want to try again click No and follow the instructions in If the Connection Between SIQA and the Machine is Unsuccessful on page 8 1 Simple Image Quality Adjustment Tool 2 17 Installation and Adjustments Guide SIQA Software Installation 6 Select OK The main SIQA window displays The Auto Alignment Adjustment and or Density Uniformity Adjustment procedures are now available Use the down arrow in the Image Quality Adjustment box to select a procedure i E Simte Ineas Quay Asmat O y 2 18 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Accessing C60 C 0 SIQA Through EFI Bustle and Standalone Once the SIQA Tool has been installed on a client PC you can access the C60 C70 through EFI Bustle or EFI Standalone with via the bustle or standalone IP address System Requirements A client PC with one of the following supported operating systems e Windows Vista SP2 e Windows 7 SP1 e Windows 8 1 Procedure
45. ween SIQA and the Machine is Unsuccessful If the connection between the printer and the PC is unsuccessful follow the steps below 1 At the Message screen click OK 2 Select Network Settings djustment o 8 2 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Troubleshooting 3 Enter the admin password 1111 default and then select OK 5 Click OK to accept the Machine Administrator ID Simple Image Quality Adjustment Tool 8 3 Installation and Adjustments Guide Troubleshooting Communication is restored between the printer and the PC The SIQA main screen displays Note If connectivity issues persist contact your system administrator 8 4 Simple Image Quality Adjustment Tool Installation and Adjustments Guide Troubleshooting If the Adjustment Values are not Saved to the Machine If the screen below displays when saving the adjustment values to a Type follow the steps below 1 At the printer follow the steps below a Press the Clear All button on the machine UI twice b Select Confirm on the screen 2 Atthe PC select Yes at the screen shown above 3 Atthe printer delete the Type Refer to Modifying a Type on p 5 21 4 Power down the machine and then power it back on 5 Repeat the procedure beginning on p 5 1 Simple Image Quality Adjustment Tool 8 5 Installation and Adjustments Guide Troubleshooting If SIQA Cannot Mak