Home
Wybron PS600 User's Manual
Contents
1. s web page For a E1 31 network view the display on the Net IT and verify that the universe numbers are set correctly If they are not then change them by going to the Net IT s web page Verify that the sender of Art Net or E1 31 is configured to the correct subnet and universe Problem Net IT will not connect to the Infogate software on my PC or MAC Net IT name does not show on top right corner or it shows in yellow Solution This is almost always caused by the computer and Net IT being on different subnets Read the Net IT display to get the IP address and subnet mask Verify that the host computer and router are on the same subnet as the Net IT Cycle power on the Net IT Computer and router 21 Problem screen is frozen or the screen is showing an error message Solution If you cannot scroll through the page feature then the software has been corrupted call Wybron Tech support Recycle the power on the Net IT The user will need to re flash the Net IT software For questions concerning Net IT and any other Wybron products please contact Tech support at 719 548 9774 22 Cables Power Data Cable The Power Data Cable uses 4 pin XLR connectors on either end and consists of two 14 AWG conductors and a 22 AWG twisted shielded pair The shells of the two XLR connectors are not electrically connected together this prevents large power currents from flowing from chassis to chassis of the equipment The twisted pair
2. Replace only with same type and rating of fuse Protection against electric shock is assured only if the mains connected power supply cord set is connected to a properly earthed grounding type receptacle For guestions contact Wybron at 1 800 624 0146 Product Modification Warning Wybron Inc products are designed and manufactured to meet the requirements of United States and International Safety standards Modifications to the products could affect safety and render the product non compliant to relevant safety standards Notes de Securite EPARGNER CES INSTRUCTIONS LIRE ET SUIVRE TOUTES INSTRUCTIONS Ce manuel donne des instructions pour la preparation l organisation et l op ration du le Net IT provision d electricite Il y a un risque de feu d charge lectrique ou la blessure aux gens si le produit n est pas utilize comme instruit AVERTISSEMENT En utilisant des appareils electrigues utilise la prudence fondamentale inclut e Lire ce manuel avant d alimenter ou l installation de l accessoire e Utiliser la prudence pres des enfants e Secher l emplacement seulement Le Net IT provision d electricite va tre utilize a la maison seulement et pas pour l usage residential Pour la protection continu e contre le risque de feu remplacer seulement avec le m me type et le m me classement de fusible La Protection contre la decharge lectrique est seulement assuree si la serie de corde connectee principale est connecte
3. einem trockenen Ort nur Der Net IT Quelle der Kraft soll in einer Hallenumwelt nur benutzt werden und ist f r Heimumwelt nicht vorgehabt F r fortgesetzten Schutz gegen Risiko des Feuers ersetzt nur mit gleichem Typ und Bewertung der Sicherung Schutz gegen Elektroschock ist nur gesichert wenn die Hauptleitungen Schnursatz verbunden haben ist an eine ordentlich earthed Erdung von Beh lter angeschlossen Eine alle Stange schaltet Vorrichtung muss sich befunden werden neben der Einheit ab oder Wenn die AC Schnur benutzt ist w hrend die Hauptleitung Vorrichtung abschaltet Sichert dass der Steckdosensteckdose ist befunden nahe die Ausr stungen installieren und ist leicht zug nglich F r Fragen Kontakt Wybron an 1 800 624 0146 oder besucht www wybron com Produkt nderungswarnung Wybron Inc Produkte sind entworfen und sind hergestellt die Voraussetzungen von Vereinigten Staaten und Internationalen Sicherheitsstandards zu erf llen nderungen zu den Produkten k nnten Sicherheit beeinflussen und k nnten das Produkt leisten das verordnungswidrig ist zu relevanten Sicherheitsstandards Introduction The Net IT takes what are currently two different boxes a DMX over Ethernet Output Node and a two universe RDM Controller IT Gateway and combines them into a single box Instead of wiring up to two different boxes and configuring each this product will make this process easier simpler and decrease failures points The Net
4. provides the ability to e Automate the setup of DMX addresses no more manual setting of DIP switches e Proactively check the condition of equipment before during and after a show e Track lamp duty cycles to predict lamp failures before they happen e Predict maintenance on equipment e Predict gel replacement prior to degradation 20 Troubleshooting Problem Net IT will not connect to my Art Net or E1 31 network Solution On the Net IT display read the IP address and subnet mask Verify what the IP address and subnet mask is of your network If they are different then connect the Net IT directly to a PC or MAC with an Ethernet crossover cable Set the PC or MAC IP address and subnet to match the Net IT Open a web browser and enter the IP address of the Net IT Change the IP address and subnet mask to the desired values of your network and click on submit Re connect the Net IT to your network Make sure the router that you are using is on the right subnet Check all Ethernet cables to the Net IT and router Cycle power on the Net IT Computer and router Problem Net IT is connected to my network but it is not sending out the DMX assigned to it Solution Verify that everything is working correctly first for the above problem For an Art Net network view the display on the Net IT and verify that the Art Net parameters for subnet and universe are set correctly If they are not then change them by accessing the Net IT
5. shield is connected at male XLR connector end only XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24VDC 14 AWG DMX512 Control Cable The DMX control cable from the lighting console to the power supply is a five conductor cable with 5 pin XLR connectors on each end The wiring pin out is specified by the USITT DMX512 1990 standard XLR Pin Function Common Data Data Talkback Talkback O1 BRB WDM 23 Appendix A Definitions acronyms and abbreviations ACN the ESTA Architecture for Control Networks standard ACN It specifies an architecture including a suite of protocols and languages which may be configured and combined with other standard protocols in a number of ways to form flexible networked control systems ANSI E1 17 Art Net an Ethernet amp UDP based specification for transport of DMX and RDM data Additionally Art Nethas built in mechanisms for the control of video projectors DMX512 Digital Multiplex 512 channels is the ANSI protocol for controlling theater equipment ANSI E1 11 ESTA Entertainment Services and Technology Association is a non profit commercial trade association representing the North American entertainment technology industry ESTA develops standards and recommended practices that facilitate the use of new and existing equipment improve communications and promote safe working conditions in the industry Etherne
6. 00 1 DMX Network Protocol Art Net nm The following parameters are unigue to Art Net Click on Submit below to save the changes Click here for Art Net setup help Network Switch TON m ArtNet Subnet 0 15 0 DMX A Universe 0 15 0 DMX B Universe 0 15 1 Y 10 Sample Web page for E1 31 configuration Net Settings Windows Internet Explorer SETA Go gt ME htto 10 231 13 104 e131_n i 9 x Y coo Pr He Edit View Favorites Tools Help 7 sly Favorites sis Suggested Sites E EEE Net IT Settings gt El dm gt Page Safety Tools Kad Use the edit boxes below to set a static IP address of the Net IT If you want to enable DHCP to get an IP addresses dynamically enter 0 0 0 0 for the IP address Click on Submit below to save the changes Click here for setup help with these four fields IP Address DHCP is OFF 10 231 13 104 Network Mask 255 0 0 0 Gateway 2001 DMX Network Protocol E1 31 m The following parameters are unique to El 31 Click on Submit below to save the changes Click here for E1 31 setup help DMX A Universe 1 65279 DMX B Universe 1 5 65279 f 11 Net IT Connection Diagram Wybron Powered 4 pin Lighting console 5 pin DMX Wvbronj PS 600 Ethernet gt Universe A Universe B Infogate Software Net IT PS 600 Connection Diagram Lighting console 5 pin DMX Ethernet U
7. 56 123 Subnet Mask InfoTrace Name Port Universe 0 ArtNet Gtway Port B Universe 1 MAC Port A OEA Infotrace connected Yes un 00 03 4 03 0d 68 Port B Output Network Protocol Art Net Artnet Port 0x1936 The front panel display shows the current settings Changing most of the settings is done through the Net IT web page To get to the web page read the IP address off the display open a browser on your PC or Mac and enter the IP address in the top line of the browser See the Quick Start Guide near the beginning of this manual for instructions on how to connect the Net IT to your computer Setting a user defined IP address On the web page enter a new IP address and click on Submit The Net IT will re boot and use the new address The web page should display again after several seconds If it does not then change the IP address of your computer to be on the new Net IT subnet Setting DHCP IP To configure the Net IT to automatically get an IP address from a DHCP server on your network on the web page enter 0 0 0 0 for the IP address and click on Submit The Net IT will re boot and DHCP To get back to the web page read the new IP address off the display and enter it into your web browser Setting the DMX Network Protocol On the web page you may select the network protocol from a pulldown option then click on Submit If you had previously assigned DMX universes to the Net IT they will be reset to default values When th
8. IT PS 600 is three products in one as it adds the functionality of a Wybron PS 600 power supply for powering Wybron fixtures such as Coloram IT CXI IT and Eclipse IT As a two port Ethernet DMX512 Gateway the Net IT receives DMX512 control protocol over Ethernet and converts it to standard 5 pin XLR DMX512 output signal The DMX over Ethernet protocols supported are Art Net ll and E1 31 streaming DMX subset of ACN The protocol can be configured on the units web page Additionally this product contains all of the RDM device control and feedback functionality found in the Infogate Gateway The Infogate GUI application will make a connection over the same Ethernet connection that is used to receive streaming DMX Please consult the Infogate Users manual for details on its use This product also has six 4 pin powered output ports for Wybron devices These ports send 24 volts DC and the DMX signal to devices eliminating the need for separate cables Caution The Net IT PS 600 is compatible with Forerunner devices but NOT the RAM Coloram Il family of devices i e Coloram Il CXI Goboram Il etc DO NOT connect A PS compatible devices to RAM Coloram II Power Supplies or RAM Coloram Il compatible devices to PS Power Supplies Damage from such action will not be covered by the equipment warranties Wybron Compatible Devices Nexera LX Coloram IT CXI IT Ecllipse IT Il Iris Shutter Forerunner color changers Refer to the use
9. WYBRON x Advancing heArtOfLighting Net IT Net IT PS600 User Manual QC umi QD 20620 Net IT 20610 Net IT PS 600 Net IT software version 1 02 with Infogate V2 25 Manual issue date April 1 2010 Table of Contents Safety NOU Ci do 3 INTOQAUCHON oda 7 Quick Start GUIAS israel dada aii 8 Net IT Connection Diagram un ana 12 Net IT PS 600 Connection Diagram 222022002n000nn0nnnnnnnnn nun nun nnnnnnnnn nun nun 13 Front ana Back Panels ann 14 NEE IT OperaHOM sisi lid 16 Net IT PS 600 Head Feet Restrictions oooccoccccccnocococcnoncnnonanonanonnnnnnanonanonaronanenannnnns 18 infolrace RDM System OVETVIOW osisssa ab re tits 20 TTOUDIESNOONMNG tica 21 Cable S iia 23 Appendix A Definitions acronyms and abbreviations 2u022002200nnn0n0n 24 User Manual Revision History au a 26 Safety Notice SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS This manual gives step by step instructions for preparation setup and operation of the Net IT There is a potential risk of injury to persons if the product is not used as instructed The Net IT is not intended for residential use WARNING When using electrical appliances use basic precautions including gt Read this manual before connecting power gt Use supervision around children gt Use in a dry location only The Net IT is to be used in an indoor environment only and is not intended for residential use
10. e Net IT is configured for Art Net and connected on a network to an Art Net controller the controller will automatically discover the Net IT There is no discovery operation performed by an E1 31 network DMX source The source simply sends the DMX over the network to whoever is listening 16 Setting the DMX Universes On the web page go the DMX A or B Universe field and enter a universe number Then click Submit For Art Net you may also select the DMX subnet and network switch In Art Net there are a possible 256 universes that are selected through 16 subnets which each contain 16 universes So a unique combination of the subnet and universe numbers define what universe a port will transmit More than one Net IT can be configured to use the same unique universe In E1 31 the universe number is directly selected as a single value from 1 to 65279 In Art Net the Network Switch will cause the unit to use an IP address of 10 x x x when it is ON or 2 x x x when it is OFF This is true only while the unit is still using the factory default IP address If a full manual IP address is entered then the Network switch has no effect until a factory reset is performed Reset Factory Defaults To reset the Net IT to factory defaults including IP address use a paperclip to hold down the rest button for ten seconds The display will show that it is resetting Infotrace Name This name shows up on the display and also on the Infogate software window on the top
11. e a un convenablement terre de type Un appareil d branchant doit tre localis c t de l unit ou si la corde de courant alternatif est utilis e comme le principal d branche l appareil S assurer que la douille sortie localise install pr s de l quipement et est facilement accessible Pour les questions Wybron de contact 1 800 624 0146 ou visite www wybron com L Avertissement de Modification de Produit Les produits de Wybron Inc sont concus et a fabriqu pour rencontrer les conditions d Etats Unis et de norms de surete internationals Les modifications aux produits pourraient affecter la surete et rendent le produit non conciliant aux normes de surete pertinentes Aviso Sobre Seguridad SALVE ESTAS INSTRUCCIONES LEA Y SIGA TODAS INSTRUCCIONES Este manual da el paso por paso las instrucciones para la preparacion para arreglo y para la operacion de la Net IT fuente del poder Hay un riesgo potencial del fuego el calambre o la herida a personas si el producto no se utiliza como instruido ADVERTENCIA Cuando se usa electrodomesticos el uso las precauciones basicas incluyendo e Lea este manual antes de accionar o instalar la instalaci n fija e Supervise a ni os cercano e Seque ubicaci n s lo La Net IT fuente del poder deber ser utilizado en un ambiente interior s lo y no es pensado para el uso residencial Para la protecci n continuada contra el riesgo del fuego reemplaza s lo con mismo t
12. e web page then you have the computer and Net IT correcily configured to the same subnet If you want more detailed instructions than are in this Quick Start guide then click on one of the two links in the web page for setup help You may change the Art Net parameters on the web page or change the protocol of the Net IT to E1 31 If you want the Net IT to use a different static IP address than the factory address then enter the desired address and subnet mask on the web page The Gateway address does not matter at this time Changing the address takes 10 seconds to take effect If you changed the IP address to be on a different subnet then you will need to change your PC or Mac to have an IP address on the same subnet If you want the Net IT to DHCP to automatically get an IP address from a network or router then set the IP address on the web page to 0 0 0 0 You will not be able to see the web page at this time If the Net IT is using a factory default IP address and the Network Protocol is configured for Art Net then the Network Switch on the web page controls the first byte of the IP address When the Network Switch is in the OFF position the unit will use an IP address of 2 x x x When the switch is on it will use an address of 10 x x x per the Art Net standard You can override this address convention by manually entering a full IP address If you have already manually entered a full static address then the Network switch has no effect un
13. ipo y calificaci n de fusible La Protecci n contra calambre se asegura s lo si el conjunto conectado principal de cuerda es conectado a un apropiadamente earthed que muele recept culo de tipo Una toda asta desconecta dispositivo se debe localizar adyacente a la unidad o si la cuerda de C A se utiliza como el principal desconecta dispositivo asegure que la enchufe salida localiza instalado cerca del equipo y sea f cilmente accesible Para preguntas el contacto Wybron en 1 800 624 0146 o visita www wybron com Advertencia de Modificaci n de Producto Wybron los productos S a se dise an y son fabricados para encontrar los requisitos de Estados Unidos y est ndares Internacionales de seguridad Las modificaciones a los productos podr an afectar la seguridad y rendir el producto no conformista a est ndares pertinentes de seguridad Sicherheitshinweise BEHALTEN SIE DIESEN ANWEISUNGEN LESEN SIE UND GEHORCHEN SIE ALLEN ANWEISUNGEN Dieses Handbuch gibt Schritt fur Schritt Anweisungen zur Vorbereitung Aufstellung und Funktion dem Net IT Quelle der Kraft Es gibt ein potenzielles Risiko des Feuers Elektroschocks oder Verletzung zu Personen wenn das Produkt nicht benutzt ist als unterrichtet ist WARNUNG Beim Benutzen elektrischer Gerate Gebrauch grundlegende VorsichtsmaRnahmen einschlieRlich e Lesen Sie dieses Handbuch vor Betreiben oder Installieren des Inventar e Benutzen Sie Aufsicht nahe Kinder e Verwenden Sie an
14. niverse A Net IT PS 600 Wybron Powered 4 pin Universe A Infogate Software Universe B 13 Front and Back Panels See the diagram on the next page The Net IT has one IEC universal power connector There are two 5 pin XLR output ports located on the unit These are labeled Port A amp Port B and output DMX RDM on two universes The Net IT PS 600 has six 4 pin XLR connectors for connecting Wybron products They transfer Universe A data and 24 volt DC power There is one Ethernet connector There are 5 LEDs that indicate the following One green LED labeled LAN flashes if the Net IT is connected to a network One green LED labeled 100Mbps that stays on if lit the link speed is 100Mbps Two blue LEDs stay on if DMX is being transmitted on port A or B happens during and after Infogate Discovery command They flash if DMX is being received from the network Two blue LEDs flash when RDM is being transmitted or received on port A or B The PAGE button is use to backlight the display and scroll through the different pages of information If the RESET button is pressed and held for 10 seconds the Net IT executes a factory default reset 14 4 RDMBLED 6 DMXAouiput S 8 Ethernet connector 9 PowerLED gt gt 15 Net IT Operation Net IT sample screens in Art Net mode ArtNet Name ArtNet Parameters Software Ver 1 02 Wybron Net IT Subnet 0 IP 10 13
15. pse IT Meli 8 Shutter 1K 8 2K Ber oe II 8 Iris 1K 87250 ll 8 Iris 2 k 812020 19 InfoTrace RDM System Overview The heart of the InfoTrace IT system is the Net IT and InfoGate PC or Mac software specialized hardware and software that uses the bi directional communications protocol Remote Device Management RDM to facilitate remote addressing and diagnostics for potentially every piece of equipment mounted on a rig Net IT works with all Wybron IT products and all RDM compatible equipment from any manufacturer In addition any non RDM equipment can be upgraded with the installation of an InfoChip Because InfoGate can work with any equipment the setup unit testing and troubleshooting for an entire rig can be coordinated from a single laptop Wybron s IT equipment Coloram IT CXI IT Eclipse IT and Nexera are equipped with a series of sensors that can relay a wealth of information to InfoGate These sensors can detect everything from light voltage and current to fan speed and even gelstring frame color information So while RDM equipment will allow identification and remote addressing IT equipment can give more specific status information and warn of potential problems possibly averting failures in the middle of a show If the status of a device indicates any problem InfoGate displays an alert with the nature of the problem and the exact location Troubleshooting is now done in a fraction of the time InfoTrace
16. r manuals for detailed operating information on these products More products will be compatible in the future Quick Start Guide The Net IT ships with a default static IP address that is unique for each unit shipped Upon powering the unit you will see the default IP address and sub net mask on the front panel backlit display Press the front panel Page button to scroll through the information to find the IP address for the following procedure The unit is factory configured to receive DMX over the Art Net II Ethernet protocol and to output DMX Universe 0 out of Port A and DMX Universe 1 out of Port B If you want to perform a factory reset of the Net IT hold down the front panel reset button for 10 seconds The Net IT will reset itself to a factory static IP address You may change the Net IT configuration from its web page using the following instructions See the sample screen shot following these instructions 1 Connect a PC or Mac directly to the Net IT using the supplied Ethernet crossover cable blue with red ends Read the IP address and subnet mask on the Net IT front panel display press the Page button Configure your PC or Mac to a different static IP address on the same subnet For example if the Net IT IP address is 10 1 2 3 and the subnet mask is 255 0 0 0 then set your computer to IP 10 0 0 2 and subnet 255 0 0 0 Open a web browser and enter the IP address of the Net IT to get to its web page If you can see th
17. right corner This name can be changed only from Infogate Art Net Name This name is only shown when the Net IT is configured for Art Net The name can be changed only from an Art Net controller Port Directions Currently the Net IT only supports output of DMX and not input The display will show both ports in an output state 1 Net IT PS 600 Head Feet Restrictions The HEAD FEET parameter is a method of accounting for the voltage drop in the power signal cable caused by the current drawn by each device To help understand this issue think of it as water pressure voltage in a hose cable where you have multiple water sprinkler heads color changers If the hose cable is too long or you have too many sprinkler heads color changers the water pressure voltage will be too low HEAD FEET is defined as the sum of cable lengths from each device to a single power supply output Head Feet Example Net IT PS 600 100 20 20 The length of cable from the Net IT PS 600 to 1st Coloram 100 2nd Coloram 120 3rd Coloram 140 360 Head Feet on one output connector 18 The following is a chart of capacity of the Net IT PS 600 for the companion devices Description Model Max Head Feet Max Devices per Output per Net IT connector PS 600 tungsten 2970 CDM 2600 Forerunner 4540 1500 amen T mao 4 8 7 5 8 110 CXI IT 4 amp 7 5 84560 1500 24 87200 CXI IT 12 812210 7 5 Ecil
18. s The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at their factory or authorized service center This warranty is contingent on the customer s full and timely compliance with the terms of payment set forth in said purchase order This warranty is expressly in lieu of any and all other warranties expressed or implied including the warranties of merchantability and fitness for a particular purpose and of other obligations and liabilities on our part The owner acknowledges that no other representations were made to him or relied upon him with respect to the quality and function of the goods sold This written warranty is intended as a complete and exclusive statement of the terms thereof Prior dealings or trade usage shall not be relevant to modify explain or vary this warranty Acceptance of or acquiescing in a course of performance under this warranty shall not modify the meaning of this agreement even though either party has knowledge of the performance and a chance to object 29 User Manual Revision History 4 1 2010 Paul Geisler Original release AAA AAA AAA AAA 26
19. sed to carry DMX RDM control signals and four pin connectors are used to carry power and control signals 24 Warranty Information WYBRON INC warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system up to a maximum of 18 months from delivery its products will be free from defects in materials and workmanship under normal use and service Warranty does not cover any product or part of a product subject to accident negligence alteration abuse misuse or any accessories or parts not supplied by WYBRON INC Warranty does not cover consumable parts such as fuses lamps or color media WYBRON INC s warranty does not extend to items not manufactured by us Freight terms on warranty repairs are FOB WYBRON INC factory or designated repair facility Collect shipments or freight allowances will not be accepted WYBRON INC s sole responsibility under this warranty shall be to repair or replace at WYBRON INC s option such parts as shall be determined to be defected on WYBRON INC s inspection WYBRON INC will not assume any responsibility for any labor expended or materials used to repair any equipment without WYBRON INC s prior written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charge
20. t A high speed serial communications network used throughout the industry InfoTrace Wybron s information control and management system that provides two way communication and control for everything on a lighting rig MAC Address Media Access Control Address This is a unique number that is hard coded into every Ethernet device The MAC address is set in a unit when it is manufactured and it should never change Net IT This is a product that receives or DMX512 over Ethernet and does a protocol translation to straight DMX512 RDM Remote Device Management Protocol RDM permits intelligent bi directional communication between devices from multiple manufacturers utilizing a modified DMX512 data link RDM is an EF 1 0 implementation of ANSI E1 11 RDM Controller Devices that primarily act as controllers and distribution devices that do their own discovery RDM Responders Devices that typically receive and act on DMX512 data and or act on RDM messages UDP Unigram data packets These are packets of data sent over an Ethernet network which do not guarantee delivery UID Unique Identifier each RDM compatible device in an RDM system must have it s own unique identification number This number is used to identify the RDM message sender and intended recipient XLR Connector A positive locking electrical connector commonly used in intelligent theatrical equipment For this product five pin connectors are u
21. til a factory reset is done 10 Connect the Net IT to your working network with Art Net or E1 31 sources or consoles Any Art Net source on the network will automatically find the Net IT If you configured the Net IT to DHCP then it will stop 11 Connect a DMX 5 pin cable to output A of the Net IT and run to your fixtures 12 Install the supplied Infogate software onto a PC or Mac connected to your network and launch it If the network is properly configured the Infogate GUI will connect to the Net IT box as indicated by a small green box on the top right corner of the Infogate program window showing ArtNet Gtway ArtNet PS600 E131 Gtway or E131 PS600 Note that this text can be changed from the Infogate software so if the Net IT has been previously used it may show other text Sample Web page for Art Net configuration Nee settings Windows Internet Explorer m x G S ME huo 10 231 13 104 artne m Rt x S pr File Edit View Favorites Tools Help wy Favorites 33 Suggested Sites El wi Z netrr Settings A dm Page Safety Tools kod Use the edit boxes below to set a static IP address of the Net IT If you want to enable DHCP to get an IP addresses dvnamicallv enter 0 0 0 0 for the IP address Click on Submit below to save the changes Click here for setup help with these four fields IP Address DHCP is OFF 10 231 13 104 Network Mask 255 0 0 0 Gateway 2
Download Pdf Manuals
Related Search
Related Contents
TELEVISOR COLOR LED/LCD Zenoah BRUSHCUTTERS KAM-402 User's Manual Anywhere Map Freedom Software Manual MG 295 HD-3D Roger Clip-On Mic 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file