Home

Wolf FHBO User's Manual

image

Contents

1. Burner ports and throats should be thoroughly cleaned Venturi must be free from grease and lint When cleaning DO NOT insert pick in burner port hole Appliances equipped with burner safeties should be checked by authorized servicer to assure proper installation Ali places where oil grease or food can accumulate must be kept clean at all times Pilot lights are to be kept clean and adjusted at the proper flame height to assure constant ignition and to prevent fire flash outs caused by delayed ignition All valves and controls at the first sign of sticking should be lubricated by a trained person using a high temperature grease At the slightest odor of gas all fittings pipes tubing and controls should be tested with soap and water for gas leakage Make repairs prior to operating this unit CAUTION DO NOT USE OPEN FLAME TO DETECT GAS LEAK 8 All operators are to be cautioned that certain materials such as silk polyester etc are highly combustible and should not come in contact with pilots burners or heated surfaces Carelessness abusive handling or altering equipment can shorten the life of the equipment and jeopardize the limited warranty offered by the manufacturer FREQUENCY OF SERVICE MAINTENANCE WILL BE LARGELY DEPENDENT ON CUSTOMER USAGE 10 12 hours operation per day 7 days a week Every 30 60 days 4 6 hours a day 5 days a week Every 120 days Limited daily usage Every 180 days All equipment should
2. be serviced at least once a year ne E WHEN ORDERING PARTS Furnish part name and number also Model and Serial Number of appliance for which part is needed Specify type of gas used Natural G 20 or Propane G 31 and altitude if over 2000 feet 610 meters Parts will be shipped C O D FOR FURTHER INSTRUCTIONS OR MINOR ADJUSTMENTS CALL YOUR LOCAL GAS COMPANY REPRESENTATIVE OR CONTACT WOLF RANGE COMPANY PARTS AND SERVICE DEPT 310 637 3737 RETAIN THIS MANUAL FOR FUTURE REFERENCE Form No 713432 11 18 99 6 WOLF RANGE COMPANY LIMITED COMMERCIAL EQUIPMENT WARRANTY EFFECTIVE APRIL 1 1995 The Wolf Range Company LLC Company warrants to the original owner that the product is free from defect in material and workmanship This warranty shall be in effect for one 1 year from the date of installation but shall not exceed eighteen 18 months from the date of shipment The warranty is limited at the option ofthe company to the replace ment or repair of any part found by the company to be defective The warranty covers labor charges for products or parts installed in the United States and Canada Labor charges shall be covered to the extent the performance is effected within 50 miles from an authorized servicer THE WARRANTY DOES NOT COVER THE OWNER SHALL BE e Misused abused or improperly installed RESPONSIBLE FOR e Exposure to harsh chemicals Proper installation and compliance with e Altered or modified by persons other than aut
3. 49 1 Nat Gas or CAN CGA B 149 2 Propane Gas 2 The installation of electrical wiring from the electric meter main control box or service outlet to the electric appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA No 70 latest edition In Canada follow the Canadian Electric Code CSA C22 2 as applicable Qualified installation personnel must be experienced in such work be familiar with all precautions required and have complied with all requirements of state or local authorities having jurisdiction QUALIFIED SERVICE PERSONNEL Qualified service personnel are those who are familiar with Wolf equipment and who have been endorsed by the Wolf Range Company All authorized servicers are required to maintain a complete set of service parts manuals and stock a minimum amount of parts for Wolf equipment NOTICE Instructions must be posted in a prominent place within the kitchen which will instruct the user of this equipment in the event he detects the smell of gas This information must be obtained from your local gas company or gas distributor Safe and satisfactory operation of your Wolf Gas Counter Appliance depends to a large extent upon its proper installation In USA installations should be made in accordance with State and Local Codes and National Fuel Gas Code ANSI Z223 1 latest edition In Canada installations should be made in accord
4. INSTALLATION amp OPERATION OWNER S MANUAL Models HB or HBi FHB or FHBi Models FHBO or FHBIO TOP FIRED BROILERS with Stainless Steel Radiant or Miracle Ray Burners Gas Operated PRE INSTALLATION e INSTALLATION Carefully check appliance for e OPERATION freight damage Report any e MAINTENANCE damage to the carrier Check appliance rating plate tor type of gas If appliance does not correspond to your type of gas contact your dealer DESIGNED AND ENGINEERED FOR COMMERCIAL USE ONLY This appliance shall be FOR YOUR SAFETY Improper installation adjustment installed in accordance with Do not store or use gasoline alteration service or maintenance current regulations and used or other flammable vapor can cause property damage or only in well ventilated space liquids in the vicinity of this injury or death Read the install Refer to instructions before or any other appliance ation and operating instructions installing and using this before servicing this appliance equipment NOTE TO INSTALLER MANUAL MUST REMAIN WITH APPLIANCE NOTE TO USER RETAIN THIS MANUAL FOR FUTURE REFERENCE The WOLF RANGE COMPANY LLC 19600 So Alameda Street Compton CA 90221 6291 P O Box 7050 Compton California 90224 7050 USA 310 637 3737 FAX 310 637 7931 800 366 WOLF Form No 713432 11 18 99 l o IMPORTANT nn OPERATING INSTALLING AND SERVICE PERSONNEL Operating information for this equipmen
5. ITY AND FITNESS FOR PARTICULAR PURPOSE Some areas do not allow limitations on whether or how long an implied warranty lasts so the limitation may not apply to you Some areas do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific rights you may also have other rights that vary from location to location The WOLF RANGE COMPANY LLC 19600 South Alameda Street Compton California 90221 310 637 3737 FAX 310 637 7931 800 366 WOLF Form No 713432 11 18 99 7 IMPORTANT INFORMATION When requesting information Owners Guides replacement parts or service al ways refer to the model and serial number of your unit The serial number of your appliance is located on the rating plate For your convenience space is provided below to record this information for future reference SERIAL NO MODEL NO DEALER INSTALLATION DATE IMPORTANT This equipment is design certified by a Nationally Recognized Testing Laboratory to the appropriate National Standards as indicated on the Equipment Rating Plate Any modification without written per mission of The Wolf Range Company LLC voids the certification and warranty of this unit NOTICE For appliances equipped with casters the installation shall be made using a connector that complies with the standard for Connectors of Movable Gas Appliances ANSI Z21 69 or Conne
6. ance with CAN CGA B149 1 and CAN CGA B142 2 Installation Code for Gas Burning Appliances amp Equipment SHIPPING DAMAGE CLAIM PROCEDURE For your protection please note that equipment in this shipment was carefully inspected and packed by skilled personnel before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of this equipment if shipment arrives damaged 1 VISIBLE LOSS OR DAMAGE Be certain this is noted on freight bill or express receipt and signed by person making delivery 2 FILE CLAIM FOR DAMAGES IMMEDIATELY Regardless of extent of damage 3 CONCEALED LOSS OR DAMAGE If damage is unnoticed until merchandise is unpacked notify transportation company or carrier immediately and file Concealed Damage claim with them This should be done within 15 days of date delivery is made to you Be sure to retain container for inspection We cannot assume responsibility for damage or loss incurred in transit We will however be glad to fumish you with necessary documents to support your claim PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Form No 713432 11 18 99 2 INSTALLATION FOR YOUR SAFETY Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Instructions must be posted in a prominent place within the kitchen area which will instruct the user of
7. ctors for Movable Gas Appliances CAN CGA 6 16 and a quick disconnect device comply with the standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CANI 6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement and guard against transmission of strain to the connector Restraining device may be attached to rear angle supports If an appliance is equipped with casters and is connected to the supply piping by means of a connector for movable appliances the user and maintenance personnel must be aware that there is a restraint on the appliance and if disconnection of the restraint is necessary the restraint must be reconnected after the appliance is retumed to its original installed position FOR SAFE OPERATION AND PROPER VENTILATION KEEP SPACE BETWEEN COOKING EQUIPMENT AND HOOD FREE FROM ANY OBSTRUCTION Your selection of WOLF equipment is your assurance of quality and dependability that reflects over 65 years of experience in manufacturing the finest commercial gas cooking equipment You can always rely on your WOLF dealer and THE WOLF RANGE COMPANY LLC to stand behind every WOLF product anywhere in the world For additional equipment service and information contact your WOLF dealer THE WOLF RANGE COMPANY LLC 19600 So Alameda Stre
8. e of installation Connect unit to 1 1 4 pipe or larger Check rating plate s for proper gas gas pressure and total BTU input for each application The gas pressure regulator must have proper OUTLET PRESSURE and capacity for battery application Warranty void if the proper gas pressure regulator is not installed CAUTION THE ITEMS LISTED BELOW MUST BE READ UNDERSTOOD AND FOLLOWED EXPLICITLY Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply of fresh air for proper combustion and ventilation and a proper ventilation system At least 24 inches must be provided at the front of the unit for servicing When installing never enclose the unit s bottom area in any manner that would obstruct the flow of air into the unit The area around this and any other gas appliance must always be kept free and clear of combustibles such as solvents cleaning fluids mops rags brooms wood tables or cabinets etc This appliance is design certified for installation without legs on a non combustible curb or platform with the front of the range projecting 3 inches beyond the front curb or platform For installation on combustible type flooring when equipped with 6 inch legs with the following minimum clearances to adjacent wall construction Combustible Non Combustible 6 inches 0 6 inches 0 LEVELING ADJUSTMENT A Counter installation use 4 or 6 adjustable legs B With cabinet base use 6 adjus
9. et Compton CA 90221 6291 P O Box 7050 Compton California 90224 7050 USA 310 637 3737 FAX 310 637 7931 800 366 WOLF Form No 713432 11 18 99 8
10. horized local codes Wolf servicers Supplying proper gas type and pressure Where serial numbers have been altered or removed Making product reasonably accessible for e Damage during transit or handling service Damage by other than genuine Wolf replacement Electrical connections ventilation parts requirements and scheduled maintenance e Damage by flood fire or other acts of God e Observation of instructions in owners manual Use of qualified servicers only The product is intended to be used for commercial purposes The warranty is void if the product is used for other than commercial purposes Replacement parts must be supplied by Wolf authorized dealers and defective parts returned in tact to same Documents verifying ownership and installation date are required Stainless steel fry tanks are war ranted for five 5 years from the date of installation Labor shall be covered for one 1 year No warranty applies to range light bulb Warranty applies only to products manufactured on or after April 1 1995 according to the manufacture date code The company shall not be liable for any consequential damages direct or special claims of loss of use claims of loss of profit or any other loss cost or expense THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF THE COMPANY THIS WARRANTY SET FORTH HEREIN IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABIL
11. n the event of power failure and no attempt should be made to operate this or any other gas appliance during a power failure OPERATING INSTRUCTIONS A Turn valve to the left counter clockwise as far as knob will go B When the burner lights turn the knob to the right clockwise until the flame is the desired height OPERATING INSTRUCTIONS MIRACLE RAY BURNERS 1 The burners are fixed with no air shutters or adjustment 2 The valves are manual on of 3 Turn valve full on to light 4 Do not adjust lower than 1 2 flame ELEVATOR Use elevator lever on right to position grill in relation to burner heat GRID POSITION AND GAS SETTING Each operator will find the optimum grid position and gas setting for various products However it is recom mended that gas input should be reduced first when lower grid temperatures are desired Further reduction in grid temperatures if necessary can then be adjusted by lowering grid position DESIGNED AND ENGINEERED FOR COMMERCIAL USE ONLY Form No 713432 11 18 99 4 Form No 713432 11 18 99 MAINTENANCE To provide proper operation and insure the safety of the user this equipment must be maintained and serviced by a trained maintenance person or an authorized servicer at regular intervals Disconnect power supply to appliance before cleaning or servicing THE FOLLOWING ARE RECOMMENDATIONS All moving parts must be checked for wear and lubricated if necessary Replace if excessively worn
12. t has been prepared for use by qualified and or authorized servicers All installation and service on this equipment is to be performed by qualified certified licensed and or authorized installation or service personnel Service may be obtained by contacting the factory Service Department factory representative or local authorized servicer DEFINITIONS QUALIFIED and or AUTHORIZED OPERATING PERSONNEL Qualified or authorized operating personnel are those who have carefully read the information in this manual and are familiar with the equipment s function or have had previous experience with the operation of the equipment covered in this manual This appliance is only for professional use and shall be used by qualified people QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals a firm corporation or company which either i in person or through a representative are engaged in and are responsible for 1 The installation of gas piping from the outlet side of the gas meter or the service regulator when the meter is not provided and the connection and installation of the gas appliance Qualified installation personnel must be experienced in such work be familiar with all precautions required and have complied with all requirements of state or local authorities having jurisdiction Reference in the United States of America National Fuel Gas Code ANSI Z223 1 latest edition In Canada Canadian Standard CAN CGA B1
13. table legs C With cabinet base curb installation unit must overhang curb 3 in front adjust 4 corner leveling bolts as required NOTE When casters are incorporated see notice on back cover Form No 713432 11 18 99 3 OPERATION FOR YOUR SAFETY Do not store gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance RETAIN THIS MANUAL FOR FUTURE REFERENCE Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply of fresh air for proper combustion and ventilation and a proper ventilation system At least 24 inches must be provided at the front of the unit for servicing When installing never enclose the unit s bottom area in any manner that would obstruct the flow of air into the unit The area around this and any other gas appliance must always be kept free and clear of combustibles such as solvents cleaning fluids mops rags brooms wood tables or cabinets etc AFTER UNIT HAS BEEN PROPERLY PIPED AND LEVELED PROCEED AS FOLLOWS 1 Turn all valves tot he OFF position wait five minutes 2 Turn on gas supply and match light two pilots and adjust Pilot valves are behind plug button on right panel 3 Caution Check all connections for gas leaks Use soap and water solution DO NOT USE OPEN FLAME 4 Burners have fixed orifices the only adjustment needed may be the air shutter SPECIAL NOTE This appliance is not capable of being operated i
14. this equipment in the event he detects the smell of gas This information must be obtained from your local gas company or authorized servicer A separate gas shut off valve should be installed in the gas line ahead of the unit as required by codes PRESSURE TESTING INSTRUCTIONS 1 The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kpa 2 The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 1 2 3 5 kpa HB or HBi ONLY Gas supply line must be 3 4 or larger If flexible or semi rigid connections are used the inside diameter must be the equivalent of 3 4 iron pipe or larger All connections of the flexible and semi rigid type must be AGA listed and comply with applicable ANSI standards Make sure gas piping is clean and free of dirt piping compound and obstructions Gas inlet pressure should be approximately 7 WC Water Column for Natural gas and 11 WC for Propane The unit is equipped with 5 WC regulator natural or with 10 WC regulator propane FHB FHBi FHBO or FHBiO ONLY IMPORTANT A gas pressure regulator suitable for Commander battery application or single unit MUST be furnished by the installer or plumber at the tim

Download Pdf Manuals

image

Related Search

Related Contents

陸上自衛隊 90式戦車 - 株式会社ハイテックマルチプレックスジャパン  SMET-SERVER  安全データシート - 林純薬 – 電子材料  important information  Philips Master Softone dimmable Energy saving bulb 872790082518300  Red YeAst RICe Red YeAst RICe  取扱説明書(PDF:1110KB)  Progress Lighting P3921-124 Installation Guide  Series 90-70 CPU, 64 MHz, 32-Bit Floating Pt, 1MB  PS200_1f_english - CP Bourg Library  

Copyright © All rights reserved.
Failed to retrieve file