White Rodgers 5A75 User's Manual
Contents
1. Si le fabricant du g n rateur d air chaud pr voit ou recommande un emplacement de la commande alors se r f rer a ces directives Sinon suivre les conseils suivants Placer les capteurs thermosensibles dans le capot du g n rateur ou ils seront soumis aux variations les plus rapides de la temp rature ui DIVISION WHITE RODGERS CONTROLS EMERSON ELECTRIC CO 9797 REAVIS RD ST LOUIS MO 63123 314 577 1300 T l copieur 314 577 1517 ES 9999 HWY 48 MARKHAM ONT L3P 3J3 IEMIERSON 905 475 4653 T l copieur 905 475 4625 Imprim aux U A DESCRIPTION PR CAUTIONS ATTENTION Afin de pr venir les chocs lectriques et les dommages mat riels pendant l installation coupez l alimentation lectrique au panneau de distribution principal AVERTISSEMENT N installez pas cet appareil sur des circuits qui d pas sent la tension nominale Une tension trop lev e peut endommager la commande et poser des risques de chocs lectriques et d incendie INSTALLATION viter les emplacements o il pourrait y avoir de l air stagnant ou une stratification qui affecterait la libre circulation de l air Les coins les courbes a petit rayon les chicanes et autres obstructions sont habituellement la cause de telles situations Ne pas placer les capteurs de la commande l ou ils risquent d tre affect s par lair qui circule du capot vers une seule canalisation PI CE No 37 0874C Rem
2. WHITE RODGERS TYPE 5A75 FAN amp LIMIT CONTROL INSTALLATION INSTRUCTIONS Operator Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND OR PROPERTY DAMAGE The White Rodgers combination warm air limit and single speed fan control combines into one compact case a switch which controls the fan or blower operation and also a switch which acts as a Safety limit control The fan switch is designed to control blower operation It will start the fan circulating warm air when the bonnet temperature reaches the pre determined temperature setting stopping the fan and when the bonnet temperature falls below the pre determined setting The warm air limit switch is designed to act as a safety switch which automatically shuts off the burner when the furnace temperature reaches a dangerously high point regardless of the cause The limit switch of these controls has special contacts which are suitable for use on low voltage and millivolt thermocouple generator type circuits as well as line voltage equipment such as gas valves oil burner motors etc THESE CONTROLS MUST BE INSTALLED BY A QUALIFIED INSTALLER Do not exceed the specification ratings All wiring must conform to local and national electrical codes and ordinances This control is a precision instrument and should be handled carefully Rough handli
3. arche manuellement afin de faire Ne pas changer le point de consigne de la commande de circuler l air pendant l t un interrupteur distance peut tre ventilateur Mettre le ventilateur en marche et l arr t l aide de install voir le sch ma de c blage l interrupteur distance
4. ch as shown in the diagram on this page Connect the limit side left hand switch according to wiring diagrams packed with the primary control gas valve oil burner control or stoker control SETTING THE CONTROL LIMIT SWITCH WITH A FIXED DIFFERENTIAL The indicator B points to the temperature at which the contacts open To set the control Use a screwdriver in the adjusting slot A on the front of the control to rotate dial until the desired temperature at which the contacts will open is positioned directly under the indicator B B FIXED INDICATOR A ADJUSTING E STOP SCREW SLOT Pr DNS REMOTE MANUAL SWITCH FOR SUMMER FAN OPERATION IF USED CAUTION The limit control is a safety device The manufacturer of the furnace as well as testing agencies U L AGA CGA have made many tests on the furnace to determine the proper dial setting The limit dial should never be set any higher than the setting it had when the furnace was delivered Do not force the dial past any stop on the dial even though the dial may be graduated beyond the stop Loosen stop screw E with enclosed wrench Set dial to original equipment manufacturer s specification Without moving the dial move stop tab F against indicator Retighten stop screw E FAN SWITCH WITH ADJUSTABLE DIFFERENTIAL The movable indicator points to the temperature at which the contacts close Th
5. e fixed indicator points to the temperature at which the contacts open The difference between these two indicators is the differential B FIXED INDICATOR CUT OUT POINT C DIFFERENTIAL ADJUSTING SCREW D MOVABLE INDICATOR CUT IN POINT A ADJUSTING SLOT For manual operation of the fan for air circulation during the summer a remote on and off switch may be used see wiring diagram SETTING THE CONTROL CONT To set the control 1 Use a screwdriver in the adjusting slot A on the front of the control to turn the dial so that the fixed indicator B points to the temperature at which the contacts will open 2 Turn the differential adjusting screw C until the movable indicator D points to the temperature at which the contacts will close SUMMER OPERATION The setting of the fan control dial should not be changed Turn the fan on and off with the remote switch TYPE 5A75 LIMITEUR ET COMMANDE WHITE RODGERS DE VENTILATEUR INSTRUCTIONS D INSTALLATION Utilisateur conservez ces instructions pour vous y r f rer au besoin SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D INSTALLER ET D UTILISER LA COMMANDE VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATERIELS Le limiteur a air chaud avec commande de ventilateur a une vitesse White Rodgers r unit dans un seul bo tier un interrupteur qui commande un ventilateur et un c
6. eur d air chaud Ne jamais forcer le cadran plus loin qu une but e m me si les graduations continuent au del de cette derni re B INDICATEUR FIXE po Desserrer la vis de but e E l aide de la cl fournie R gler le cadran selon les recommandations du fabricant de l quipement 3 En prenant soin de ne pas d placer le cadran accoter la but e F contre l indicateur Serrer nouveau la vis de but e E A A FENTE DE R GLAGE E VIS DE BUT E e REGLAGE DE LA COMMANDE suite COMMUTATEUR DE VENTILATEUR A DIFFERENTIEL Pour r gler la commande REGLABLE 1 Introduire la pointe d un tournevis dans la fente de r glage L indicateur mobile donne la temp rature a laquelle les contacts A qui se trouve a l avant de la commande Tourner le seront ferm s L indicateur fixe donne la temp rature laquelle cadran pour que l indicateur fixe B indique la temp rature les contacts seront ouverts La diff rence entre les deux indi laquelle les contacts devront tre ouverts cateurs repr sente le diff rentiel 2 Tourner la vis de r glage du diff rentiel C jusqu ce que l indicateur mobile D indique la temp rature laquelle les contacts devront tre ferm s B INDICATEUR FIXE POINT D ENCLENCHEMENT C VIS DE R GLAGE DU DIFF RENTIEL D INDICATEUR MOBILE POINT DE D CLENCHEMENT A FENTE DE R GLAGE FONCTIONNEMENT ESTIVAL Pour mettre le ventilateur en m
7. ion PART NO 37 0874C Replaces 37 0874 1 amp 37 9098 9549 INSTALLATION CONT The elements should be bent so that they will not touch the heated surface or be affected by reflected or radiated heat unless such a position is determined by the furnace manu facturer Care must be used when bending the element to prevent kinking it The element should not be bent with a radius of less than one inch and all bending should be done between the coiled part of the element anda point one inch from the diaphragm cup The element should be shaped over the thumbs so that a round bend is obtained On remote controls the long capillary tubing between the sensitive bulb and the switch mechanism should be led over a path that will protect it from cuts blows wear due to vibration etc Use the paper template packed with the control to obtain the mounting dimensions WIRING ELEMENT AFFECTED BY AIR GOING NORMALLY TO ONLY ONE DUCT GOOD ELEMENT LOCATION AIR FLOW OVER ELEMENT AFFECTED LA BU HUMIDIFIER ELEMENT MAY BE TOO CLOSE TO HUMIDIFIER SOURCE OF HEAT UNLESS SUCH POSITION IS DETERMINED BY FURNACE MANUFACTURER All wiring should be done in accordance with local and national electrical codes and ordinances If the furnace or burner manufacturer recommends a wiring diagram then follow such recommendations If none are of fered connect the fan side right hand swit
8. lectriques INTERRUPTEUR DISTANCE MANUEL DE FONCTIONNEMENT ESTIVAL DU VENTILATEUR LIMITEUR VENTILATEUR SI UTILIS ons i ee eE BATS ire alle AT OST E I ire EX peo Si le fabricant du g n rateur d air chaud ou du br leur recom mande un sch ma de c blage alors s y r f rer Sinon raccorder le commutateur de ventilateur c t droit de la fa on indiqu e dans le sch ma ci contre Raccorder le limiteur c t gauche selon les sch mas de c blage fournis avec la commande principale le robinet gaz la commande de br leur mazout ou la commande de chargeur automatique SOUS TENSION R SEAU MOTEUR DE VENTILATEUR R GLAGE DE LA COMMANDE LIMITEUR DIFF RENTIEL FIXE L indicateur B donne la temp rature laquelle les contacts seront ouverts Pour r gler la commande introduire la pointe d un tournevis dans la fente de r glage A qui se trouve l avant de la commande Tourner le cadran pour que la temp rature laquelle les contacts devront tre ouverts se trouve directement sous l indicateur B ATTENTION Le limiteur est un dispositif de s curit Le fabricant du g n rateur d air chaud ainsi que les agences d homologation UL AGA CGA ont effectu plusieurs essais dans le but de d terminer le point de consigne qui convient Ne jamais r gler le cadran du limiteur un point de consigne sup rieur au r glage d origine du g n rat
9. ng or distorting components could cause the control to malfunction This control has been accurately calibrated at the factory any attempt to calibrate this control will void the White Rodgers warranty If the furnace manufacturer has made provision for or recom mendations for location of this control then follow those instruc tions If not the following suggestions should be observed The temperature sensitive bulbs should be positioned in the furnace bonnet so that they will be located in the area which is subjected to the most rapid temperature changes WHITE RODGERS DIVISION EMERSON ELECTRIC CO 9797 REAVIS RD ST LOUIS MO 63123 314 577 1300 FAX 314 577 1517 9999 HWY 48 MARKHAM ONT L3P 3J3 905 475 4653 FAX 905 475 4625 es En Printed in U S A DESCRIPTION PRECAUTIONS CAUTION To prevent electrical shock and or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete AWARNING Do not use on circuits exceeding specified volt age Higher voltage will damage control and could cause shock or fire hazard INSTALLATION Avoid locations where there may be dead air spots or stratifica tion affecting free air circulation Corners sharp turns baffles or other obstructions usually cause these conditions Do not locate the control elements where the air flow from the bonnet into any single duct will control its operat
10. ommutateur qui sert de limiteur de s curit L interrupteur est con u pour commander la mise en marche d un ventilateur Il mettra en marche le ventilateur de circulation d air chaud lorsque la temp rature du capot aura atteint le point de consigne tabli Il arr tera le ventilateur lorsque la temp rature du capot sera descendue sous ce point de consigne Le limiteur air chaud est con u pour servir de commutateur de s curit Il arr te automatiquement le br leur lorsque le g n rateur atteint une temp rature dangereusement lev e peu importe la cause Le limiteur de ces commandes est dot de bornes sp ciales Elles permettent d utiliser l appareil avec des circuits basse tension et a millivolts avec g n rateur thermocouple ainsi qu avec des quipements a la tension du r seau comme des robinets a gaz des moteurs de br leur mazout etc LA COMMANDE DOIT ETRE INSTALLEE PAR UN TECHNI CIEN QUALIFIE Ne d passez pas les charges nominales Tout le c blage doit tre conforme aux codes et r glements locaux et nationaux qui r gissent les installations lectriques Cette commande est un instrument de pr cision qui doit tre manipul avec soin Elle peut se d traquer si elle est manipul e de fa on n gligente ou si des composantes sont d form es La commande a t calibr e avec pr cision lors de la fabrication Toute tentative de calibrer l appareil annulera la garantie de White Rodgers
11. place 37 0874 1 amp 37 9098 9551 INSTALLATION suite Plier les capteurs de fa on assurer qu ils ne touheront pas a la surface chauff e et qu ils ne seront pas affect s par la chaleur r fl chie ou rayonnante sauf si une telle position est recom mand e par le fabricant du g n rateur d air chaud Prendre soin en pliant les l ments de ne pas les bosser Ne AFFECTE PAR L AIR D UNE SEULE CANALISATION 4 L AIR QUI CIRCULE pas plier le capteur avec un rayon de moins de 2 5 cm 1 po AUTOUR DU CAPTEUR Le plier entre le serpentin et un point qui se trouve 2 5 cm EST AFFECT PAR 1 po del obturateur Plier le capteur sur le pouce afin d assurer une courbe bien ronde Dans le cas de commandes avec capteur a distance acheminer le tube capillaire qui relie le capteur au commutateur le long d un L HUMIDIFICATEUR HUMIDIFICATEUR GENERALEMENT UN BON EMPLACEMENT LE CAPTEUR EST PEUT ETRE TROP PROCHE DE LA x SOURCE DE trajet qui le prot ge des coupures des coups de l usure due aux CHALEUR SAUF SI vibrations etc UNE TELLE Ar POSITION EST Pour les dimensions de montage de la commande se r f rer au RECONNAND gabarit de papier qui est fourni PAR LE FABRICANT DU G N RATEUR C BLAGE Tout le c blage doit tre conforme aux codes et r glements locaux et nationaux qui r gissent les installations