Home
        White Rodgers 36E93-304 User's Manual
         Contents
1.  appliance if any part has been under     WHAT TO DO IF YOU SMELL GAS    water  Immediately call a qualified service technician to  Do not try to light any appliance  inspect the appliance and to replace any part of the  control system and any gas control which has been    Do not touch any electrical switch  do not use any under water     phone in your building     Immediately call your gas supplier from a neighbor   s  phone  Follow the gas supplier   s instructions     OPERATING INSTRUCTIONS      STOP  Read the safety information above on this label  7  Wait five  5  minutes to clear out any gas  If you then    Set the thermostat to lowest setting  smell gas  STOP  Follow    B    in the safety information    _ Turn off all electric power to the appliance  above on this label  If you don   t smell gas  go to the    f     i   ae f   next step     This appliance is equipped with an ignition device which T trol knob terclockwise to    ON      automatically lights the pilot  Do not try to light the pilot e AUN gaS CONO  KNO COUMETCIOCKWISG 10 SHIN   by hand    Replace control access panel       Remove control access panel    Turn on all electric power to the appliance     Turn gas control knob clockwise to    OFF       Set thermostat to desired setting     If the appliance will not operate  follow the instructions       To Turn Off Gas To Appliance    and call your service  technician or gas supplier     TO TURN OFF GAS TO APPLIANCE      Set the thermostat to lowest setting  4  
2. 36E93 304    WHITE RODGERS Delay Opening Combination Gas Valve  INSTALLATION INSTRUCTIONS       Operator  Save these instructions for future use     FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE  INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY  AND OR PROPERTY DAMAGE     DESCRIPTION    The 36E93 304 combination gas valve is designed for  intermittent ignition system applications  The valve is  equipped with a redundant solenoid valve that controls  gas flow to the pilot and main burners  a main valve that  controls gas flow to the main burner  a pressure regulator  to maintain a constant outlet pressure  and a two position  gas cock knob for manual gas shut off        SPECIFICATIONS  Type of Gas  Natural gas Ambient Temperature   LP gas  use conversion kit   40   to 175  F  Pressure Regulator Setting  Pressure Rating  14    W C    2 PSI  max   Nat  Gas     2 5 to 5 0    W C  Voltage  24 VAC  LP Gas  7 0 to 12 0    W C  Frequency  50 60 Hz  PIPE SIZES CAPACITIES    Capacity  BTU hr  at  Pipe Sizes Available 1    pressure drop across valve     inches  AGA Sid  Nat  Gas LP Gas   1 000 BTU cu  ft      2 500 BTU cu  ft      75 000  75 000  00 000  140 000  140 000          MOUNTING POSITIONS   Upright  or 0   to 90   from upright    INLET BOSS  UPRIGHT LEFT OR RIGHT UP OR DOWN    CONTENTS  Description  Specifications  Precautions  Installation  Pilot Gas Connection  System Wiring  Adjustment  Manual Valve Knob  Pilot Gas Adjustment  Pressure Regulat
3. Turn gas control knob clockwise to    OFF     Do not force       Turn off all electric power to the appliance if service is to 5  Replace control access panel   be performed       Remove control access panel           If you need more information about this product  you may write to us at      WHITE RODGERS DIVISION  Emerson Electric Co   9797 Reavis Road  St  Louis  MO 63123 5398    
4. ed with the pilot outlet plugged  For  installations requiring pilot gas  remove the plug and use  the fitting packed separately with the control     Install the fitting into the pilot gas tapping  turning until  finger tight  see fig  2   Insert clean  deburred tubing all  the way through the fitting  Hold the tubing securely in  place and slowly tighten the fitting until you feel a slight     give     Then tighten the fitting an additional 11   2 turns     See ADJUSTMENT section  page 5  and fig  6 for pilot set  up         Pilot Gas  Outlet  Regulator  Pressure Vent    Main Gas  Outlet    Figure 2    All piping must comply with local codes  ordinances   and or national fuel gas codes        minimum minimum  4 t  Piped Gas Piped Gas  Supply Supply       3 in           Tubing Gas  Supply    Figure 3  Typical gas valve piping    SYSTEM WIRING    REFER TO AND FOLLOW THE APPLIANCE  MANUFACTURER   S WIRING DIAGRAM  REFER TO  FIG  4 FOR TERMINAL IDENTIFICATION     All wiring should be installed in accordance with local and  national electrical codes and ordinances     Always check that the electrical power supply used agrees  with the voltage and frequency shown on the gas control        INSTALLATION  cont d                                Figure 4  Gas valve wiring diagram    ADJUSTMENT  MANUAL VALVE KNOB    The manual valve knob is a two position  ON OFF  type   To turn manual valve on  rotate knob clockwise or coun   terclockwise to line up the word ON on the knob with the  ind
5. icator on the cover casting  see fig  5   To turn manual  valve off  rotate knob clockwise or counterclockwise to  line up the word OFF on the knob with the indicator on the  cover casting     PILOT GAS ADJUSTMENT    These controls are factory preset to provide proper pilot  gas flow for most applications  If additional adjustment is  necessary  follow these steps     1  Turn off all electrical power to the system before  making any adjustments     2  Remove the pilot adjust cover screw and gasket to  expose the adjusting screw  see fig  6   Turn the  adjusting screw clockwise to reduce pilot flame  or  counterclockwise to increase pilot flame     3  Replace the gasket and pilot adjust cover screw and  tighten securely     4  Restore power to the system     Regulator  Cover Screw     Plastic  Adjust S  just Screw S    Regulator    Adjust Screw    B    Figure 6    Pilot  Cover Screw  a    Gasket         Pilot                   a        DK PILOT ADJ  A A Manual valve knob  Indicator    shown in OFF position          Figure 5  Manual gas valve knob    PRESSURE REGULATOR  ADJUSTMENT    These controls are shipped from the factory with the  regulator set for 3 5    W C   natural gas  full flow   Consult  the appliance rating plate to ensure burner manifold  pressure should be 3 5    W C  If another outlet pressure is  required  follow these steps     If a valve has been factory adjusted for the 2 5 to 5 inches  W C  range  itcannot be field adjusted outside that range   This is als
6. o true for valves adjusted to the 7 5 to 12 inches  W C  range for LP gas     1  Turn off all electrical power to the system     2  Attach a manometer to the outlet pressure tap of the  valve     3  Turn on system power and energize valve     4  Remove regulator cover screw and turn regulator  adjust screw clockwise to increase pressure  or  counterclockwise to decrease pressure  see fig  6    Always adjust regulator to provide the correct pres   sure according to the original equipment  manufacturer s specifications listed on the appliance  rating plate     5  Replace regulator cover screw and tighten securely     LIGHTING INSTRUCTIONS    FOR YOUR SAFETY READ BEFORE OPERATING    A WARNING wy If you do not follow these instructions exactly  a fire or explosion  may result causing property damage  personal injury or loss of life       This appliance is equipped with an intermittent ignition e If you cannot reach your gas supplier  call the fire  device which automatically lights the appliance  Do not try department   to light the pilot by hand    C  Use only your hand to turn the gas control knob  Never  use tools  If the knob will not turn by hand  don   t try to  repair it  call a qualified service technician  Force or  attempted repair may result in a fire or explosion       BEFORE OPERATING smell all around the appliance area  for gas  Be sure to smell next to the floor because some  gas is heavier than air and will settle on the floor     FOR YOUR SAFETY   Do not use this
7. or Adjustment Figure 1  Gas valve mounting positions             B  HITE RODGERS DIVISION   EMERSON ELECTRIC CO  2 PART NO  37 5291C   mummy    9797 REAVIS ROAD Printed in U S A  Replaces 37 5291B  EMERSON ST LOUIS  MISSOURI 63123 5398 9615    PRECAUTIONS    DO NOT BEGIN INSTALLATION UNTIL YOU READ  THE FOLLOWING PRECAUTIONS     A WARNING Me    Failure to turn off electric or main gas supply  to heating system could cause personal in   jury and or property damage by shock  gas  suffocation  fire  and or explosion     Do not use this control on circuits exceeding  specified voltage  Higher voltage will dam   age the control and may cause shock or fire  hazard     NEVER USE FLAME OR ANY KIND OF SPARK  TO CHECK FOR GAS LEAKS COULD CAUSE  FIRE AND OR EXPLOSION     A CAUTION    Do not short out terminals on gas valve or  primary control to test  Short or incorrect  wiring can cause equipment damage  prop   erty damage  and or personal injury     If you do not follow these instructions exactly  a fire or explosion may  result  causing property damage  personal injury or loss of life     DO NOT USE WIRE JUMPER on pilot sys   tems  such as standing pilot  proven pilot  or  spark to pilot ignition   a fire and or explo   sion may result     Do not use a control set for natural gas with  LP gas  or a control set for LP gas with  natural gas  Personal injury and or property  damage  gas suffocation  fire  and or explo   sion may result     This control is not intended for use in loca   
8. tions where it may come in direct contact  with water  Suitable protection must be pro   vided to shield the control from exposure to  water  dripping  spraying  rain  etc             Turn off electrical power to the system at the fuse box  or circuit breaker  Also turn off the main gas supply   If replacing an existing valve  disconnect all plumbing  and electrical connections from the old control    The control may be installed in any position  except  upside down  The arrow on the bottom plate indicates  the direction of gas flow through the valve    You should use new pipe that is properly chamfered   reamed  and free of burrs and chips  If you are using  old pipe  be sure it is clean and free of rust  scale   burrs  chips  and old pipe joint compound    Apply pipe joint compound  pipe dope  or teflon tape  that is approved for all gases  only to the male  threads of the pipe joints  DO NOT apply com   pound or teflon tape to the first two threads  see fig  3  for typical piping connections     If you are using a vise or open end wrench to hold the  valve while installing piping  do not tighten exces   sively  as this may damage the valve    See SYSTEM WIRING when making electrical con   nections  After all gas and electrical connections are  completed  turn gas on and check for gas leaks with  leak detection solution or soap suds  Bubbles forming  indicate a leak  SHUT OFF GAS AND FIX ALL  LEAKS IMMEDIATELY     INSTALLATION  PILOT GAS CONNECTION    These valves are shipp
    