1. Gas Pressure Regulator The gas pressure regulator supplied with this range must be used The inlet pressure to the regulator should be as follows for proper operation Natural gas Minimum pressure 5 WCP Maximum pressure 14 WCP LP gas Minimum pressure 11 WCP Maximum pressure 14 WCP Contact local gas supplier if you are not sure about the inlet pressure Because Whirlpool Corporation policy includes a continuous commitment to improve our products we reserve the right to change materials and specifications without notice PRODUCT DIMENSIONS A 3534 Ye 90 8 0 3 cm cooktop height minimum with leveling legs screwed all the way in B Model serial rating plates located behind the control panel C 47 Ye 119 7 0 3 cm overall height minimum with leveling legs screwed all the way in D 28 2 14 72 4 0 6 cm depth with handle E 26 to 27 Ye 66 4 0 3 cm F 29116 Vie 76 0 0 2 cm width Model serial rating plates may be rotated up from behind the control panel for viewing from the front of the range Range can be raised approximately 1 2 5 cm by adjusting the leveling legs Excludes handle Dimension given is from wall to front of oven door and will vary based on electrical outlet receptacle installation Type of Gas Natural gas This range is design certified by CSA International for use with Natural gas or after proper conve
2. o J Whirl Ool 30 76 2 cm Freestanding Gas Range PRODUCT MODEL NUMBERS GGG388LX GGG390LX GAS SUPPLY REQUIREMENTS Gas supply line e Provide a gas supply line of 3 4 1 9 cm rigid pipe to the range location A smaller size pipe on longer runs may result in insufficient gas supply With LP gas piping or tubing size can be 1 2 1 3 cm minimum Usually LP gas suppliers determine the size and materials used in the system NOTE Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape Flexible metal appliance connector e f local codes permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 12 1 3 cm or 3 4 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line eA 1 2 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator e Do not kink or damage the flexible metal tubing when moving the range e Must include a shutoff valve The supply line must be equipped with a manual shutoff valve This valve should be located in the same room but external to the range opening such as an adjacent cabinet It should be ina location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or shutting off gas to the range A Gas supply line B Shutoff valve open position C To range
3. od combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop A 18 45 7 cm upper cabinet to countertop B 13 83 0 cm upper cabinet depth C 30 76 2 cm min opening width D For minimum clearance to the top of the cooktop see NOTE E 30 76 2 cm min opening width F 3 7 6 cm min clearance from both sides of the range to the side wall or other combustible material G Cabinet door or hinges should not extend into the cutout H 3 7 6 cm distance from wall I 1 3 8 cm min from right side cabinet J 8 20 3 cm width K 7 17 8 cm min from floor L 2 5 1 cm min from floor Drill on centerline 11 4 3 1 cm from rear wall for gas supply line Gas lines must be installed within the shaded area to ensure proper alignment of this oven with cabinets Electrical plugs must be installed within the shaded area to ensure proper alignment of this oven with cabinets NOTE 24 61 0 cm minimum when bottom of wood or metal cabinet is covered by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm Stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top
4. of the cooking platform and the bottom of an uncovered wood or metal cabinet qualified electrical installer determine that the ground path is adequate e A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this range be provided e Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Check that the outlet provides 120 volt power and is correctly grounded s oo 812 21 6 cm gas line location Page 2 of 2 Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only For complete details see Installation Ref W10526071A our products we reserve the right to change materials and specifications without notice Instructions packed with product Specifications subject to change without notice 2 13 13
5. rsion for use with LP gas e This range is factory set for use with Natural gas See Gas Conversions section The model serial rating plate located behind the control panel has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP gas conversion Conversion must be done by a qualified service technician No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas without consulting the serving gas supplier See Gas Conversions section TEFLON is a registered trademark of E I Du Pont De Nemours and Company Page 1 of 2 Dimensions are for planning purposes only For complete details see Installation Ref W10526071A Instructions packed with product Specifications subject to change without notice 2 13 13 ELECTRICAL REQUIREMENTS IMPORTANT The range must be electrically grounded in accordance with If codes permit and a separate ground wire is used it is recommended that a local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA G22 1 CABINET OPENING DIMENSIONS Cabinet opening dimensions shown are for 25 64 0 cm countertop depth 24 61 0 cm base cabinet depth and 36 91 4 cm countertop height IMPORTANT If installing a range hood or microwave ho

Download Pdf Manuals

image

Related Search

Related Contents

Sterling Dehumidifier STT 800 User's Manual  Benutzerhandbuch / User Manual Laser-Entfernungs  Antennas Direct Micron  Ektron CMS200 Installation Manual  Manuel d`utilisation Modèle CL-60 Modèle CL-35  Samsung WF7600NAS User Manual  Politiques et techniques de recrutement La sélection des candidats  取扱説明書  APC DC PWR SHELF 60A 48V REAR ACCESS  limit 500 / 600 / 800 installation and user's manual  