Home

Whirlpool MK2167 User's Manual

image

Contents

1. B A Rail guides B Rails Slide the microwave oven back and into place The mounting holes of the rail flanges and bottom duct flange will align against the bottom front facing of the cutout cabinet opening 6 Secure the microwave oven to the cutout cabinet by installing four short screws into the mounting holes A Mounting holes B Short screws 4 1 Position trim kit frame over the opening so that the lower tabs 3 Secure trim kit frame to cutout cabinet by installing four long rest on the cutout floor as shown wood screws painted into the pilot holes drilled in Step 2 above A Front of trim kit frame B Tabs upper and lower C Cutout cabinet floor 2 Holding the trim kit frame in place use 7 64 drill to drill four pilot holes into the front facing of the cutout cabinet through the mounting hole guides in the upper and lower corners of Installation is now complete Replace any loose items that have the trim kit frame been removed from microwave oven cavity NOTES Save these Installation Instructions for future reference m The holes will be drilled downward from the top and upward from the bottom at an angle of about 45 m To avoid damage to the trim kit frame do not overtighten screws A B A Trim kit frame C Long wood screw 4 painted B Mounting hole guide D Cutout ceiling SECURITE DU FOUR A
2. A Cutout floor B Centerline C Bottom duct D Bottom duct flange E Front facing 3 Align the center arrows on the bottom duct with the centerline drawn in Step 1 above A Bottom duct B Center arrows aligned with centerline 4 Mark the three mounting holes through the bottom duct onto the cutout floor ag o 0 E B A Short screws 3 B Bottom duct mounting holes 5 Using 7 64 drill drill pilot holes into the three holes marked in Step 4 6 Realign and install the bottom duct with three short screws 7 Using 7 64 drill drill pilot holes through the four mounting holes of the bottom duct flange into the bottom front facing of the cutout cabinet opening A B Bez A Bottom duct flange B Mounting holes 1 2 9 Gently return microwave oven to its upright position Position microwave oven near cutout opening AWARNING 4 Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Plug in microwave oven Align the rails with the rail guides on the bottom duct
3. MICRO ONDES Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves a vous et a d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient A DANGER A AVERTISSEMENT Risque possible de d c s ou de blessure grave si vous ne suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions INSTRUCTIONS D INSTALLATION Outillage et pi ces Outillage n cessaire Rassembler les outils et composants n cessaires avant d entreprendre l installation Lire et observer les instructions fournies avec chacun des outils de la liste ci dessous m Perceuse m Foret de 7 64 m Metre ruban m Crayon m Tournevis Phillips Pi ces fournies pas l chelle Tringles 2 Cadre de la trousse de garniture Espace d vacuation
4. MICROWAVE OVEN BUILT IN TRIM KIT INSTALLATION INSTRUCTIONS Built In Trim Kit Models MK2167 MK2160 UL listed for use over any electric or gas built in oven up to 30 76 2 cm wide INSTRUCTIONS D INSTALLATION GARNITURE ENCASTREE POUR FOUR A MICRO ONDES Garniture encastr e pour mod les MK2167 MK2160 Homologation UL pour utilisation au dessus de tous les fours encastr s lectriques ou gaz jusqu 30 76 2 cm de largeur Table of Contents Table des mati res MICROWAVE OVEN SAFETY nine 1 S CURIT DU FOUR MICRO ONDES n nnnsssessnnnnnnnnneerneeeeeee011 101 7 INSTALLATION INSTRUCTIONG ccccssssssssessseseesesesneaes INSTRUCTIONS D INSTALLATION Tools and Pars cece aa ga vei Outillage et pi ces Location Requirements bie Exigences d emplacement Required Cutout Dimensions Dimensions n cessaires de l ouverture d encastrement 8 Trim Kit Frame Dimensions Dimensions du cadre de la trousse de garniture 8 Electrical Requirements Sp cifications lectriques 0 0 ee eee eect eee ceeeeeeeeeeeeeaeeaeeaeeaeeaeeeeeeeaee 9 Prepare Microwave Oven ss Pr paration du four micro ondes 9 Prepare Cutout Cabinet Opening 4 Pr paration de l ouverture d encastrement cceeeeeeeeeeeeeee 10 Install the Microwave Oven Installation du four micro ondes Install Trim Kit Frame nesate iden adan ianiai a Installation du cadre de la trousse de garnit
5. e NOTES m Depth requirements depend upon receptacle and its location within or outside of recommended region See illustration and chart above m Height dimension is critical 17 43 2 cm minimum 17 43 5 cm maximum m Width measurement has 1 16 2 mm tolerance m 3 7 6 cm minimum dimension is from lower oven cutout ceiling to microwave oven cutout floor m Trim kit frame extends 16 2 7 cm above and below the cutout opening Trim Kit Frame Dimensions 267 68 2 cm 2994 75 6 cm Le 2234 57 8 cm 37 16 1978 8 7 cm 48 6 cm 2 e 5 2 cm 31 2 8 9 cm 12 4 31 1 cm F 13 6 3 0 m 27 68 6 cm trim kit 30 76 2 cm trim kit Electrical Requirements AWARNING Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Observe all governing codes and ordinances Required m A120 volt 60 Hz AC only 15 or 20 amp electrical supply with a fuse or circuit breaker Recommended m A time delay fuse or time delay circuit breaker m A separate circuit serving only this microwave oven GROUNDING INSTRUCTIONS E For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circ
6. ement dans le placard en passant par les quatre trous de montage du rebord de l espace d vacuation inf rieur A B d A Rebord de l espace d vacuation inf rieur B Trous de montage 1 Remettre le four micro ondes l endroit avec pr caution 6 Fixer le four micro ondes l ouverture d encastrement dans 2 Placer le four micro ondes proximit de l ouverture le placard en installant quatre vis courtes dans les trous de d encastrement montage AVERTISSEMENT y Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique B A Trous de montage 3 Brancher le four micro ondes B Vis courtes 4 4 Aligner les tringles avec les rails de guidage sur l espace d vacuation inf rieur Dangu A Rails de guidage B Tringles 5 R ins rer le four micro ondes dans la cavit pour le remettre en place Les trous de montage des extr mit s de tringles et du rebord de l espace d vacuation inf rieur s alignent contre la partie inf rieure avant de l ouverture d encastrement dans le placard 11 1 Placer le cadre de la trousse de
7. garniture sur l ouverture de 3 Fixer le cadre de trousse de garniture l ouverture sorte que les languettes inf rieures reposent sur le plancher d encastrement dans le placard en installant quatre vis bois de l ouverture tel qu illustr longues peintes dans les avant trous perc s l tape 2 ci dessus B A A Avant du cadre de la trousse de garniture B Languettes sup rieure et inf rieure C Plancher de l ouverture d encastrement dans le placard 2 Tout en maintenant le cadre de trousse de garniture en place utiliser un foret de 7 64 pour percer quatre avant trous dans l avant de l ouverture d encastrement dans le placard L installation est maintenant termin e R installer tous les articles travers les rails de guidage des trous de montage dans les qui auraient t retir s de la cavit du four micro ondes angles sup rieurs et inf rieurs du cadre de trousse de Conserver ces Instructions d installation pour une ventuelle garniture r utilisation ult rieure REMARQUES m Les trous sont perc s de haut en bas et de bas en haut un angle d environ 45 m Pour viter d endommager le cadre de la trousse de garmiture ne pas trop serrer les vis A B A Cadre de la trousse C Vis bois longues 4 peintes de garniture D Plafond de l ouverture B Rail de guidage du d encastrement trou de montage W10532204A SP PN W10532205A 261800311939 2012 Whi
8. imales de profondeur consulter le tableau 16 2 7 cm o 15 2cm gt 23 58 7 17 43 2 cm min 17 43 5 cm max m aka uerssessse EOE 16 2 7 cm 3 _4 7 6 cm D C A D passement du cadre de la trousse de garniture B Ouverture pour le four inf rieur C Zone recommand e pour l emplacement de la prise de courant pas moins de 6 15 2 cm jusqu la droite de l axe central de l ouverture d encastrement D Axe central de l ouverture d encastrement Emplacement de la Profondeur minimale prise de courant Dans la zone recommand e 18 45 7 cm avec la prise de courant en affleurement 21 53 2 cm avec la prise de courant sans affleurement Hors de la zone 19 49 5 cm avec la prise de courant recommand e en affleurement 222 57 2 cm avec la prise de courant sans affleurement REMARQUES m Les crit res de profondeur d pendent de dimensions de la prise de courant et de son emplacement selon qu elle se trouve ou non dans la zone recommand e Voir l illustration et le tableau ci dessus m La dimension de hauteur est critique 17 43 2 cm au minimum 17 43 5 cm maximum m La mesure de largeur peut tre modifi e de 1 16 2 mm m La dimension minimale de 3 7 6 cm correspond la distance du plafond de l ouverture d encastrement du four inf rieur au plancher de l ouverture d encastrement du four micro
9. inf rieur ug Vis bois longues 6 peintes 4 2 suppl mentaires Vis courtes 14 11 3 suppl mentaires Exigences d emplacement Le four micro ondes peut tre install par dessus un four encastr Si l on installe le four micro ondes par dessus un four encastr s assurer qu il existe un d gagement minimal de 3 7 6 cm entre le sommet de l ouverture d encastrement du four inf rieur et le plancher de l ouverture d encastrement du four micro ondes Le four micro ondes peut aussi tre install seul dans un placard sans four encastr en dessous Pour faciliter l utilisation de l appareil une distance minimale de 36 91 4 cm est recommand e entre le plancher et le plancher de l ouverture d encastrement S assurer que les placards environnants peuvent s ouvrir et se fermer librement Laisser un d gagement d au moins 1 6 4 cm sous le plancher de l ouverture d encastrement 3 7 6 cm pour une installation au dessus d un four encastr et un d gagement d au moins 2 5 1 cm au dessus de l ouverture d encastrement Hs pe og 5 1 cm p t t 4 7 6 cm C D 36 91 4 cm A Placard sup rieur C Ouverture d encastrement B Ouverture d encastrement du inf rieure four a micro ondes D Placards inf rieurs E Plancher Dimensions n cessaires de l ouverture d encastrement Pour conna tre les distances min
10. ondes m Le cadre de la trousse de garniture d passe de 1146 2 7 cm au dessus et au dessous de l ouverture d encastrement Dimensions du cadre de la trousse de garniture 267 68 2 cm 29 2 75 6 cm e 22 4 57 8 cm 376 19 8 7 cm 48 6 cm E 2 6 5 2 cm 312 8 9 cm 12 4 31 1 cm 1 6 3 cm S Trousse de garniture de 27 68 6 cm Trousse de garniture de 30 76 2 cm Sp cifications lectriques AVERTISSEMENT N Xu Risque de choc lectrique Brancher sur une prise 3 alv oles reli e la terre Ne pas enlever la broche de liaison la terre Ne pas utiliser un adaptateur Ne pas utiliser un c ble de rallonge Le non respect de ces instructions peut causer un d c s un incendie ou un choc lectrique Observer les dispositions de tous les codes et r glements en vigueur N cessaire m Une alimentation lectrique de 120 volts 60 Hz CA seulement 15 ou 20 amp res prot g e par un fusible ou un disjoncteur Recommand m Un fusible temporis ou un disjoncteur temporis m Un circuit distinct exclusif ce four micro ondes INSTRUCTIONS DE LIAISON A LA TERRE E Pour tout appareil m nager connect par un cordon de courant lectrique Il faut que le four micro ondes soit reli la terre En cas de court circuit lectrique la liaison la terre r duit le risque de choc lectrique ca
11. ourtes 4 B Plancher du four D Rebords micro ondes E Porte Fixer les tringles au plancher du four micro ondes l aide de quatre vis courtes 3 10 D terminer et marquer l axe central sur le plancher de ouverture d encastrement Positionner l espace d vacuation inf rieur dans l ouverture en faisant reposer le rebord contre l avant inf rieur de l ouverture A B C ee es eu i D E A Plancher de l ouverture d encastrement B Axe central C Espace d vacuation inf rieur D Rebord de l espace d vacuation inf rieur E Avant Aligner les fl ches centrales de l espace d vacuation inf rieur avec l axe central illustr l tape 1 ci dessus A B A Espace d vacuation inf rieur B Fl ches centrales align es avec l axe central D a oll ey Marquer l emplacement des trois trous de montage a travers l espace d vacuation inf rieur sur le plancher de l ouverture d encastrement eg e r B A Vis courtes 3 B Trous de montage de l espace d vacuation inf rieur l aide d un foret de 7 64 percer des avant trous dans les trois trous indiqu s l tape 4 R aligner et installer l espace d vacuation inf rieur avec les trois vis courtes l aide d un foret de 7 64 percer des avant trous dans l avant inf rieur de l ouverture d encastr
12. r le courant lectrique dispose d un itin raire direct d acheminement la terre Le four micro ondes est dot d un cordon de courant lectrique qui comporte un fil de liaison la terre avec broche de liaison la terre On doit brancher la fiche sur une prise de courant convenablement install e et reli e la terre AVERTISSEMENT L utilisation incorrecte du dispositif de liaison la terre peut susciter un risque de choc lectrique L utilisateur qui ne comprend pas bien les instructions de liaison la terre ou qui n est pas certain que le four micro ondes soit convenablement reli la terre devrait consulter un lectricien ou un technicien qualifi Ne pas utiliser un c ble de rallonge Si le cordon de courant lectrique est trop court demander un lectricien ou un technicien qualifi d installer une prise de courant proximit du four micro ondes CONSERVEZ CES INSTRUCTIONS a Pr paration du four micro ondes D brancher le four micro ondes avant de poursuivre l installation Retirer les articles l int rieur du four micro ondes le cas ch ant Placer avec pr caution le four micro ondes sur son sommet en orientant la porte vers l avant vers l installateur Aligner les deux tringles sur le plancher du four micro ondes tel qu illustr en s assurant que les rebords sont orient s vers l avant et vers le haut D E A Tringles 2 C Vis c
13. rlpool Corporation 9 12 All rights reserved Used under license in Canada Printed in China Tous droits r serv s Utilis sous licence au Canada Imprim en Chine
14. uit grounding reduces the risk of electric shock by providing an escape wire for the electric current The microwave oven is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper use of the grounding plug can result in a risk of electric shock Consult a qualified electrician or serviceman if the grounding instructions are not completely understood or if doubt exists as to whether the microwave oven is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician or serviceman install an outlet near the microwave oven SAVE THESE INSTRUCTIONS Prepare Microwave Oven Unplug microwave oven before proceeding with installation Remove any loose items inside microwave oven 3 Gently turn microwave oven onto its top with the door facing forward toward installer 4 Align the two rails on the microwave oven bottom as shown making sure the flanges are forward and pointing up N A Rails 2 B Microwave oven bottom C Short screws 4 D Flanges E Door 5 Secure the rails to the microwave oven bottom using four short screws 1 On the cutout floor find and mark the centerline 2 Place the bottom duct in the opening with the flange resting against the bottom front facing of the opening A B C i a ee
15. ure e ceeeeeeeeeee 12 MICROWAVE OVEN SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DANGER follow instructions You can be killed or seriously injured if you don t follow A WARN l N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed W10532204A INSTALLATION INSTRUCTIONS Tools and Parts Tools Needed Gather the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here m Drill m 7 64 drill bit m Measuring tape m Pencil m Phillips screwdriver Parts Supplied not shown to scale Bottom duct Trim kit frame Rails 2 Short screws 14 11 3 extra Long wood screws 6 painted 4 2 extra Location Requirements The microwave oven may be installed over a built in oven If installing over a built in oven make s
16. ure there is a minimum of 3 7 6 cm between the top of the lower oven cutout and the microwave oven cutout floor The microwave oven may also be installed in a cabinet by itself without a built in oven below For best usability we recommend a minimum distance of 36 91 4 cm from the floor to the cutout floor Make sure the surrounding cabinetry has clearance to open and close freely Allow a clearance of at least 1 6 4 0 cm below the cutout floor 3 7 6 cm for installation above a built in oven and a clearance of at least 2 5 1 cm above the cutout opening ge ee SI 5 1 cm t 4 7 6 cm C D Lower cabinets E Floor A Upper cabinet B Microwave oven cutout C Lower oven cutout Required Cutout Dimensions For minimum depth requirements see chart i 16 2 7 cm r 15 2 cm gt B 17 43 2 cm min 17 43 5 cm 23 58 7 cm 16 max i 2 7 cm 3 7 6 aig B D C A Trim kit frame overhang B Cutout for lower oven C Recommended region for receptacle location no less than 6 15 2 cm to the right of cutout centerline D Cutout centerline Receptacle Location Minimum Depth Within recommended region 18 45 7 cm with flush receptacle 21 53 2 cm with non flush receptacle Outside recommended 19 49 5 cm with flush receptacle region 222 57 2 cm with non flush receptacl

Download Pdf Manuals

image

Related Search

Related Contents

LaCie SAFE Mobile Hard Drive 80GB USB 2.0 - Fingerprint Access Control  KOHLER K-7421-NA Instructions / Assembly    form mp75106/15 request / authorisation for repair  Snap Appliance Snap Server 110 250GB  SIE DIE 2G-NMS  AQGY Inscription Mode d`Emploi 2015-2016    FC-DR919Mega  

Copyright © All rights reserved.
Failed to retrieve file