Home

Whirlpool SC 8630 User's Manual

image

Contents

1. 1 gm Remove foam shipping blocks and tape from cooktop Untape power cord 2 m Remove pressure regulator hardware package burner grates and caps package from shipping box CAUTION Property Damage Lift entire cooktop up from cutout when repositioning cooktop in countertop opening Failure to do so could scratch countertop m Insert cooktop into countertop cutout Do Not remove protective film from foam tape Center cooktop in cutout Check that front edge of cooktop is parallel to front edge of countertop Check that all required clearances are met and that cooktop is properly positioned Ise a pencil to mark a line along the rear of cooktop on countertop to align cooktop in Step 5 protective 4 mw Remove cooktop Bumer foam rom cutout and place it box tape Jpside down on a cooktop orotected surface remove protective film from foam tape Do Not remove foam tape The foam tape seals cooktop to countertop for proper gas combustion and prevents liquids from leaking under cooktop Numbers correspond to 5 m Insert cooktop into cutout while aligning rear of cooktop with pencil line Check that cooktop is parallel to the front edge of countertop Lift the entire cooktop to make adjustments so that the foam tape can seal properly A WARNING Electrical Shock Fire Hazard Disconnect power supply cord from wall receptacle before servicing cooktop Failure to do so could result i
2. National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 American Gas Association 1515 Wilson Boulevard Arlington Virginia 22209 Tools needed for installation SS ASA N Y Q pipe wrench flat blade screwdriver sd 4 pliers A F adjustable wrench tape measure ruler Gas supply requirements Observe all governing codes and ordinances WARNING Fire Hazard Cooktop must be connected to a regulated gas supply Do Not use an open flame to test for leaks from gas connections New A G A design certified flexible gas line should be used when codes permit Failure to follow these instructions could result in a fire explosion or personal injury A This installation must conform with local codes and ordinances In the absence of local codes installations must conform with American National Standard National Fuel Gas Code ANSI 7223 1 latest edition B m Input ratings shown on the serial rating plate are for elevations up to 2 000 feet For elevations above 2 000 feet ratings are reduced at a rate of 4 for each 1 000 feet above sea level C m The sealed gas cooktop is manufactured for use with NATURAL gas Conversion to L P gas can be made with Kit No 4372174 available from your Whirpool dealer or authorized parts distributor No attempt shall be made to convert the appliance from the gas specified on the serial rat
3. Wait a few minutes for gas to move through the gas line A WARNING Fire Hazard Do Not use an open flame to test for leaks from gas connections Checking for leaks with a flame may result in a fire or explosion 1 1 m Use a brush and liquid detergent to test all gas connections for leaks Bubbles cround connections will indicate a leak If a leak appears shut off gas valve controls and adjust connections Then check connections again NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAME Clean all detergent solution from cooktop 1 2 m Plug the power supply cord into the grounded outlet burner cap burner base ignitor electrode gt gas tube opening 1 3 E Piace trim rings over each burner Find the two locating tabs under the burner cap and mount cap over the slots in the burner base Place burner grates over burners and caps Electronic Ignition System initial lighting Cooktop burners use electronic igniters in place of standing pilots When the cooktop ccntrol knob is pushed in and turned to the LITE position the system creates a spark to ligat the burner This sparking continues until the control knob is turned to the desired sevting OFF OO OO HI LITA Ben LO 1 4 mw Check the operation of the cooktop burners Push in and turn each control knob to LITE position The flame should light within 4 seconds Do Not leave the knob in the LITE position after burner
4. FLOOR WHERE THE COOKTOP IS TO BE INSTALLED MUST BE SEALED Product Dimensions Width 30 Burner box height 3 30 min base cabinet is required If cabinet has a drawer a 3 depth clearance from the countertop to the top of the drawer or other obstruction in base cabinet is required Cabinet and Cutout Dimensions DA cabinet width above cooktop Minimum distance to nearest rear combustible surface depth above cooktop N p ee 19 opening depth 1 min space between adjacent cooktops awe 18 min clearance upper cabinet to countertop 2 1 4 min space to front 26 5 8 min edge of gt opening width i i Recommended z 3 area for 120v N l grounded outlet Wall gas line W on rear cabinet opening l D 22 wall 5 below countertop and centered in ae cabinet Centerline of l a wall and unit Important Observe all l governing codes and ordinances N z Centerli Failure to meet codes Noo ottloor and ordinances could N lead to fire or electric 7 Do Not pinch the shock power supply cord x between the cooktop and cabinet Clearance Dimensions Note 30 min when bottom of wood or metal cabinet is protected by not less than 1 4 flame retardant millboard onesie KN covered with not less than No countertop 28 MSG sheet steel 0 015 ia stainless steel 0 024 aluminum ee Note or 0 020 copper SeGraneee 36 min c
5. as follows for both operation and checking the regulator setting NATURAL GAS Minimum pressure 5 inches W C Maximum pressure 14 inches W C i m Line pressure testing Testing above 1 2 psi 14 inches W C gauge Tne cooktcp and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5kPA Testing at 1 2 psi 14 inches W C gauge or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure tasting of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5kKPA Electrical requirements A WARNING Electrical Shock Hazard e Electrical ground is required on this appliance Do Not ground fo a gas pipe Do Not modify the power supply cord plug If plug will not fit the outlet have a proper outlet installed by a qualified electrician Do Not have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in an electrical shock Do Not use an extension cord with this appliance e Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Failure to follow these instructions could result in serious injury or death If codes permit and a separate grounding wire is used it is
6. recommended that a qualified electrician determine that the grounding path is adequate A 120 volt 60 Hz AC only 15 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity ar necessary In addition to checking that the outlet provides 120 volt power and is correctly grounded the outlet must be checked by a qualified electrician to see if it is wired with correct polarity A wiring diagram is provided in the literature package Recommended grounding method For your personal safety this appliance must be grounded This appliance is equipped wih a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and local codes and ordinances See Figure 1 if a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong wall receptacle installed by a qualified electrician 3 prong grounding type wall receptacle 7 C CH 3 prong t grounding amp plug i grounding prong power supply cord Figure Now start With cooktop in kitchen
7. Installation Instructions Part No 202887 1100 Rev 3 4372169 Rev C IMPORTANT Read and save these instructions BROAN o ao 30 with the homeowner Sealed Burner Cooktop Homeowner Keep Installation Instructions for future reference Save Installation Instructions for local electrical inspector s use Note This cooktop is manufactured for use with Natural gas To convert for use with L P Propane gas requires Kit No 4372174 for use with model SC 8630 EB series only available from your Whirlpool dealer or authorized parts distributor This cooktop is not approved for use with downdraft vent systems Before you start Proper installation is your responsibility Make sure you have everything necessary for correct installation It is the responsibility of the installer to comply with the installation clearances specified on the serial rating plate The serial rating plate can be found on the underside of the cooktop burner box Note This cooktop is manufactured for use with Natural gas To convert for use with L P Propane gas requires Kit No 4372174 available from your Whirlpool dealer or authorized parts distributor De ee Check location where cooktop will be installed The location should be away from strong draft areas such as windows doors and strong heating vents or fans The cooktop should be located for convenient use in the ktchen ALL OPENINGS IN THE WALL OR
8. ge above the cooking surface If cabinets are already installed reduce the hazard of reaching over a heated cooking surface by installing a range hood The range hood should extend a minimum of 5 inches out from the bottom front of the cabinets Reaching over a heated cooking surface could result in a serious burn or other personal injury Electrical Shock Hazard It is the customer s responsibility To contact a qualified electrical installer To assure that electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Failure to do so could result in fire electrical shock or other personal injury Take special care when drilling holes into the wall for electrical wiring Electrical wires may be concealed behind the wall covering Failure to do so could result in fire electrical shock or other personal injury Mobile home installation The installation of this cooktop must conform tc the Manufactured Home Construction and Safety Standards Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installations 1982 Manufactured Home Sites Communities and Setups ANSI A225 1 NFPA 501A 1987 or latest edition or with local codes Copies of the standards listed may be obtained from
9. ible without going out You have just finished installing your new Whirlpool cooktop To get the most efficient use from your new cooktop read your Whirlpool Use amp Care Guide Keep Installation Congratulations Instructions and Guide close to cooktop for easy reference The instructions will make reinstalling your Whirlpool cooktop in another home as easy as the first installation If cooktop does not operate Check that the circuit breaker is not tripped or house fuse blown Check that power supply cord is plugged into wall receptacle Check that gas valves are turned to tne ON position A more detailed troubleshooting checklist is provided in the Use and Care Guide Part No 202887 1100 Rev 3 4372169 Rev C 1994 Whirlpool Corporation If you need assistance The Whirlpool Consumer Assistance Center will answer any questions about operating or maintcining your cooktop not covered in the Installation Instructions The Whirlpool Consumer Assistance Center is open 24 hours a day 7 days a week Just dial 1 800 263 1301 the call is free When you call you will need the cooktop model number and serial number Both numbers can be found on the serial rating plate located on the underside of the cooktop burner box CORPORATION Prepared by Whirlpool Corporation Berton Harbor Michigan 49022 If you need service In the event that your Whirlpool appliance should
10. ing plate for use with a different gas without consulting the servicing gas supplier Conversion must be done by a qualified service technician using only the kit number specified D m Provide a gas supply line of 3 4 rigid pipe to the cooktop location A smaller size pipe on long runs may result in insufficient gas supply Pipe joint compounds made for use with NATURAL and L P gas must be used permit A G A design certified flexible metal tubing is recommended for connecting this cooktop to the gas supply line Do Not kink or damage the flexible tubing when moving the cooktop A 2 male pipe thread is needed for connection to pressure regulator female pipe threads Panel B shutoff vaive open position to cooktop ee supply line F The supply line shall be equipped with an approved shutoff valve This valve shoulc be located in the same room as the cooktop and should be in a location that allows ease of opening and closing Do Not block access fo shutoff valve The valve is for turning on or shutting off gas to the appliance G a If rigid pipe is used as a gas supply line a combination of pipe i fittings must be used to obtain an in line connection to the cooktop All strains must be removed from the supply and fuel lines so cooktop will be level and in line E m The regulator must be checked at a minimum l inch water column above the set pressure The inlet pressure to the regulator should be
11. learance between the top of the cooking platform and the bottom of an unprotected wood or metal sheet Minimum distance to nearest combustible surface above cooktop Panel A Grounded electrical outlet is required See Electrical requirements Proper gas supply connection must be available See Gas supply requirements Countertop opening dimensions that are shown must be used Given dimensions provide required 0 clearance Important Observe all governing codes and ordinances Failure to meet codes and ordinances could lead to fire or electrical shock WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do Not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do Not try to light any appliance Do Not touch any electrical switch Do Not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier A WARNING Fire Hazard Do Not obstruct the flow of combustion and ventilation air Personal Injury Hazard Avoid installing cabinet stora
12. lights f burners do not light properly turn control krob to the OFF position Check that burner cap is in the proper position Check that power supply cord is plugged in and that the circuit breaker or house fuse has not blown Check that the shutoff valve is in the ON position Check operation again f a burner does not light at this point contact your Whirlpool dealer for assistance en control knob to HI position Check each cooktop burner for proper flame The small inner cone should have a very distinct blue flame approximately 1 2 long Tne outer cone is not as distinct as the inner cone to surface Nau 1 6 m Push in and turn each control knob to the LO or simmer setting The LO setting of each burner has been factory set to the lowest setting available to provide reliable reignition of the burner If it does not stay lit on the LO setting Check LO setting as follows a Turn control to LITE until burner ignites b Quickly turn knob down to LOWEST POSITION c If burner goes out readjust valve as follows Remove the surface burner control knob Insert a flat blade screwdriver into the hollow valve stem and engage the slotted screw inside Flame size can be increased or decreased with the turn of the screw Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame Flame should be as small as poss
13. n serious injury or death CAUTION Product Damage Do Not overtighten screws Overtightening screws could damage cooktop surface 6 m insert one clamp through each slot located on the sides of the burner box Secure cooktop to countertop by hand tightening each screw Do Not overtighten screws T m Install the pressure regulator with the arrow on the regulator pointing up toward unit and in a position where you can reach the access cap 4 WARNING Fire Hazard Do Not make connection too tight The regulator is die cast Overtightening may crack regulator resulting in a gas leak and possible fire or explosion 1 2 nipple flexible connector 1 2 nipple 1 2 adapters manual shutoff valve pressure regulator All connections must be wrench tightened 8 m Assemble the flexible connector from the gas supply pipe to the pressure regulator in order manual shutoff valve 1 2 nipple 1 2 adapter flexible connector 1 2 adapter and 1 2 nipple Panel C sohih 9 m Use pipe joint compound made for use with NATURAL and L P gas to seal all gas connections If flexible connectors are used be certain connectors are not kinked shutoff valve open position to cooktop gt a to gas supply line 1 0 m Open the shutoff valve in the gas supply line
14. need service call the dealer from whom you purchased the appliance or a Whirlpool authorized service company A Whirlpool authorized service company is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service or Repair You can also obtain the service company s name and telephone number by dialing free within the continental United States the Whirlpool Consumer Assistance Center telephone number 1 800 253 1301 A special operator will tell you the name and number of your nearest Whirlpool authorized service company Maintain the quality built into your Whirlpool appliance call a Whirlpocol authorized service company Care cleaning and maintenance If removing the cooktop is necessary for cleaning or maintenance shut off gas supply Disconnect the gas and electric supply Remove the mounting bracket on the right and left side of burner box After disconnecting the gas and electric supply finish removing the unit for servicing and cleaning Reinstall in reverse order and check gas connection for leaks Printed in Canada

Download Pdf Manuals

image

Related Search

Related Contents

Progress Lighting P3821-09 Installation Guide  implementation of pid controller for controlling the liquid level of the  Untitled - QSL.net  Proportional Injector Bomba de dosificación proporcional Pompe à  1. Safety Precautions  Office of Budget and Financial Planning  PayPal Authorization & Capture - 2006 Integration Guide  