Contents
1. 2388 mm L 2 0 h p 1 5 kW 75 6 4000 5 6KW 740 Ibs 975 Ibs 230 VAC Plus 87 2210 230 VAC H 3 mm W 36 927 10 AMP 4 www clearcreekspas com www clearcreekspas com 230 1514 ltrs 26 AMPS 340 kg 443 kg 5 4 9 0 3450 MPM Single Phase 60 Hz A S M i P n g S r h a a t 5 6 0 i H 2 i t See page 4 PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE www clearcreekspas com www clearcreekspas com INSTALLATION Installation Instructions Inspection and Shipping Claim Check for shipping damage upon receipt of the spa Jacuzzi Whirlpool Bath is not responsible for damage to the spa sustained during shipping If damage is evident before unpacking see instructions regarding shipping claims on the outside of the carton and immediately file a claim with the carrier Once the spa has been removed from the carton and before it is permanently installed see below on this page for unpacking instructions check the spa completely for damage Fill the shell with water and operate the system see Operating Instructions to check for leaks which may have resulted from shipping or handling All Jacuzzi Whirlpool Bath spas are factory tested for proper operation and watertight connections prior to shipping If leaks or other problems are detected immediately notify your Jacuzzi Whirlpool Bath dealer or Authorized Service Agent or cal
2. Do not remove the suction grilles They are safety devices and must always be in place on the suction fitting to minimize the potential hazard of hair entanglement or body entrapment The wet surface of the spa is slippery Use care when entering and exiting While the optional spa cover is rigid it is not designed to support any weight Therefore as a safety precaution do not sit stand or lie on it The spa must be installed with adequate access and water drainage system See Installation Instructions When using the electrical equipment basic safety precautions should always be followed This unit is equipped with an earth leakage circuit breaker ELCB located in the electrical cabinet Check at least once a month to be sure this is operational The procedure for testing is described on page 7 of this manual Do not use electrically connected devices such as televi sion radio or stereo speakers lights cooking devices or telephones within 1 5m 5 feet of the spa while the spa is being used Lighting fixtures must not be located directly above or within 1 5m 5 feet of the spa If located with 3m 10 feet of the spa they must be on a circuit protected by an ELCB Do not apply power to the spa unless it is filled with water to the normal water level which is to the water level indicator mark on the skimmer frame Activating the spa when there is an insufficient amount of water can damage the circulation pump and
3. excessive alkalinity above 7 6 pH add dry acid to the spa water Caution Refer to the spa chemical manufacturer s instructions for the initial amount of chemicals to add for the gallonage of your spa Low pH can cause equipment damage as acidic water will dissolve metals while high pH can cause scale or calcium deposits to build up in the system or on the shell After adding chemicals run the filter system for at least 30 minutes before testing water quality again for accurate readings Balancing Total Alkalinity Total alkalinity is the measure of base materials in the water The recommended range for total alkalinity is be tween 80 ppm and 150 ppm If the chemistry of the water is not within this range you will have difficulty adjusting your pH level which will affect your adjustments for the proper amount of free available chlorine If the alkalinity of your spa water is high itis advisable to drain the water from the spa and begin the balancing process over again Purge and sanitize your spa according to instructions in Equip ment Set Up section of the Installation Instructions and cleanthe spa surfaces thoroughly before refilling with fresh water Then re establish water chemistry If the spa is used heavily change the water at least every month WATER QUALITY DEFINITIONS pH A chemical term used in expressing relative acid ity or alkalinity in numeric values with 7 0 usually regarded as neutral and for purposes of
4. or skimmer basket B Filter clogged dirty B Clean or replace C Poor water chemistry C See Chemistry section D Insufficient filtering time D Run filter E Improper maintenance E See Maintenance section F High content of solids in water F Use clarifier or drain and refill spa G Filter motor not operating G 5 Abnormal water usage A Leak in suction line dis A Repair leak charge line or connections B Excessive evaporation and or B Use rigid spa cover lower splashing thermostat setting 6 Low water flow from jets A Normal operation in FILTER A Select JETS mode for maximum mode flow B Normal operation when Water B Turn off Water Rainbow Rainbow on C Low water level C Fill to water levelindicator mark on skimmer filter frame Note The skills and tools necessary for the safe repair of this spa require the services of qualified service personnel Contact your Jacuzzi Whirlpool Bath dealer www clearcreekspas com www clearcreekspas com www clearcreekspas com 17 www clearcreekspas com TROUBLESHOOTING GUIDE PROBABLE CAUSE PROBLEM 6 Low water flow from jets E Continued F 7 No water flow from jets 8 Noisy pump and motor A Leakage of air into suction line Vibrating parts attached to moto Qn Dirty filter Suction or discharge line partially plugged Pump running at subnormal speed Worn or damaged pump seal
5. this manual indicating pure water From 7 to 0 indicates increasing acidity and 7 to 14 indicates alkalinity PPM Parts per million Free Chlorine Chlorine that has not combined with other chemicals and that is available to destroy bacte ria in the spa water TriChlor A form of chlorine used in pool or spa water treatment usually supplied in tablet form Not recom mended because of its higher acidic nature and slow dissolving action Prolonged contact with the spa shell may bleach or permanently mark the shell Sodium DiChlor The type of chlorine that is recommended for spa use as it is available in fast dissolving granular form It is neither excessively acid nor alkaline in character and does not readily dissipate in higher water temperatures Calcium Hypochlorite A granular chlorine prod uct that is inexpensive and effective but not recom mended because it often tends to form calcium depos its on heater parts and plumbing fittings and leaves an unattractive film on the spa at the water line Sodium Hypochlorite A liquid chlorine product that is inexpensive and effective but not recommended because the liquid is readily spilled onto the spa or a surrounding area causing permanent damage Total Alkalinity The measure of amount of alka line materials such as carbonates bicarbonates and hydroxides in the water High alkalinity inhibits the effectiveness of chemicals to change the pH If the alkalinity of your spa
6. to be captured in the filters may bring about various undesir able water quality conditions These conditions can be corrected with the use of spa treatment chemicals which are available from your Jacuzzi Whirlpool Bath dealer Such conditions include the following Foaming A defoamer is available to minimize foaming of the water This condition is usually caused by the addition of soaps or oils or other fatty substances to the spa water The interaction of these with hot water especially at high pH more alkali will cause the water to foam See Water Quality Definitions Oil Film or Cloudy Water Add clarifier to congeal oil film on the water surface into globules sufficiently large to be trapped by the system s filter Cloudiness is caused by particles that are too small to be trapped in the filter and is also due to the presence of human body oils lotions and cosmetics After adding clarifiers these materials will accumulate on the filter element and clog its pores The addition of clarifier will make the water clearer but clogged filters must be cleaned as prescribed under the section entitled Filter Maintenance in this manual Hard Water Add a de mineralizer to break down or de ionize mineral particles present in the spa water Follow the Filter Maintenance procedure described in this manual to ensure optimum performance of your spa s filtration system Water Chemistry You can ensure better water chemis
7. L THERMOMETER Sr FILTER CARTRIDGE DIRECTIONALLY ADJUSTABLE WHIRLPOOL JET SUCTION COVER www clearcreekspas com www clearcreekspas com OPERATION Operating Instructions Now that your Quantum Plus spais in place you are probably eager to take advantage of its unique designed in features especially the patented Jacuzzi Whirlpool Bath hydromassage performance Besides being a beautiful addition to your indoor decor or outdoor landscaping your Jacuzzi whirlpool spa will provide you with the ultimate in spa pleasure Basic Control Set Up The control set up on your Quantum Plus spa is designed to give you fingertip control of the heater lights air induction Water Rainbow and whirlpool filter pump and blower systems of your unit from inside or outside your spa Follow the basic control set up described below to familiarize yourself with the several functions of the control panels located on the top of h ee CAUTION Do not turn on power to the spa unless it is filled with water to the normal water level See water line indicatormark on skimmer frame When the power is on the built in timer may activate the system even though the SYSTEM is turned off at the control panel If the spa s motor pump is actuated when there is not sufficient water in the unit the circulation pump and heater could be irreparably damaged In addition to damaging the unit operating the spa with insufficient water could cause a fire Using a ga
8. Subnormal voltage Power turned off Selector switch in OFF House circuit breaker tripped no power to system Spa circuit protector tripped High temperature safety switch es tripped ELCB tripped Faulty pump or motor Motor s not connected Jet or jets closed Clogged strainer s or support brackets Low water level Damaged or worn motor bearings Impeller rubbing inside pump Debris inside pump REMEDY E F G H Call an electrician or your power company A Turn on power at service panel B Select other function C Reset circuit breaker D Reset circuit protector E Reset button s on heater after water has cooled see Note if switch continues to trip F Reset ELCB G H Chech motor plug connection on System Control Module 1 Open jet A Clean strainer s B Locate and repair leaks C Tighten fasteners D Add water to normal water level E F G 9 Water leakage at pump shaft A rotating connection between pump and motor 10 Motor will not start A B C Worn or damaged pump seal Power off OFF mode selected House circuit breaker tripped or in OFF position D Spa circuit breakers tripped E ELCB tripped Note The skills and tools necessary for the safe repair of this spa require the services of qualified service personnel Contact your Jacuzzi Whirlpool Bath dealer www clea
9. The Quantum Plus S 4 a a IN Ne S rs Ss Fi N N SJ 2 II www clearcreekspas com IMPORTANT SAFETY INFORMATION READ ALL INSTALLATION INSTRUCTIONS Jacuzzi Whirlpool Bath does not recommend spa water temperatures in excess of 40 C 104 F High water temperatures in excess of 40 C 104 F and prolonged periods of use can raise the internal human body tempera ture excessively and impair the body s ability to regulate its internal temperature Limit your initial use of the spa to 10 15 minutes High body temperatures affect people differently consult your physician about your safety and comfort before using the spa The elderly the infirm and children should not use the spa unattended Infants should not be permitted in the spa at water temperatures over 38 C 100 F Pregnant women and people with heart conditions should consult their phy sicians before using the spa at water temperatures over 38 C 100 F Extra care should be taken when using the spa and con suming alcoholic beverages Alcohol drugs or certain medications such as tranquilizers affect a person s ability to withstand high temperatures and may produce dangerous effects Keep body hair and clothing a minimum of 300mm 12 inches away from suction fitting and skimmers at all times when the spa is operating Hair longer than shoulder length should be secured close to the head or a bathing cap should be worn
10. Time clock controls Maximum whirlpool action filter pump Heater Heater will maintain will turn on with temperature set by filter pump if thermostat is thermostat set TEMP CONTROL KNOB B nd HTR FLTR and FILTER only LIGH functions T w functi ACCESSORY e ons SYSTEM SWITCH r SWITCH Controls AIR Controls JETS a www clearcreekspas com HTR FLTR Filter pump and heater will turn on as necessary to maintain water temperature setting FILTER NDI Filter pump will CAT run continuously OR heater will turn LIG on as necessary to maintain water temperature setting www clearcreekspas com www clearcreekspas com OPERATION Temperature Control Turn on the heater by selecting the HTR FILTER mode on the SYSTEM selector switch With this selection you can verify that the spa s heater is operating by viewing the HEATER ON light on the spa side panel Set the Temp Control knob by rotating it to the desired temperature The temperature will be higher as the knob is rotated clockwise When the water temperature is lower than that set by the heater control the heater and filter motor pump will be activated The heater and filter func tions will automatically turn off when the desired tempera ture is reached When the heater is on the water is also being filtered The heater will also maintain water tempera ture in the JETS mode The heater control is designed to maintain a minimum tempera
11. cific local code compliance prior to installation of the product Jacuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance JACUZZI WHIRLPOOL BATH Jacuzzi Whirlpool Bath National Headquarters P O Drawer J Walnut Creek CA 94596 510 938 7070 Customer Service Call 800 288 4002 Copyright 1987 Jacuzzi Whirlpool Bath C756000 B 11 93 A Printed on Recycled Paper Printed in the U S A www clearcreekspas com
12. e circuit breakers are in the ON 1 position Locate the HIGH TEMPERATURE SAFETY SWITCHES which are raised buttons on the end of the heater Push both buttons to be sure it is in the reset mode The purpose of both switches is to shut down the spa if the water becomes excessively hot If for some reason the switches are tripped the reset button must be pushed in for the heater to operate again after the water has cooled to about 38 C 100 F Set the built in timer see below Use of the timer allows two modes of operation timed HEATER FILTER and FILTER ONLY With the SYSTEM switch turned OFF HIGH TEMPERATURE SAFETY RESET BUTTON Setting the Timer The built in 7 day timer is located in the System Control Module The tooth like tabs that are located on the dial can be set to activate the filter system for two hour period on any day s of the week First turn the program dial gradually clockwise until the day of the week 7 day timer and time of day on the outer dial is aligned with the triangle marker on the inner dial two o clock position For to the minute setting turn the minute hand clockwise to the exact time of day NOTE Both the correct time and day must be set Next slide one of the tabs outward to the time at which you and the HEATER knob set to the desired tempera ture the timer will activate the heater and filter pump to operate during the time period set on the timer With the SYSTEM switch turned OFF and
13. e luxury and excitement to your spa experi ence The Quantum Plus offers the convenience of two patented front loadskimmer filters for maximum efficiency The unique 4 65m 50 sq feet filtration system designed by Jacuzzi Whirlpool Bath allows easy access from inside the spa to both filter cartridges without having to drain the spa or open the skirt door A standard feature of the Quantum Plus is its two Water Rainbow spouts with flow control which will create a daz zling shimmering waterfall effect while recirculating the water The spa shell is foam insulated to save energy costs and the spais tastefully surrounded by a factory installed redwood skirt The complete equipment pack of the Quantum Plus is TOP VIEW LN a p SICA 1 au E NIE TERA SERIAL NUMBER LOCATION SIDE VIEW alternate heating source and can be used remotely The Quantum Plus is available in several lustrous colors See the Jacuzzi Whirlpool Bath color guide mounted within the perimeter of the spa so the spa is easy OPTIONS to install The spa requires a 230 VAC 50 AMP grounded Gas Heater separate circuit and is equipped with an ground fault circuit Rigid Insulating Cover interruter GFCI An optional gas heateris available as an Pillows PPE EIR ATIONS WHIRLPOOL FILTER MOTOR MOTOR OPERATING ELECTRIC PRODUCT SHIPPING ELECTRICAL MODEL DIMENSIONS PUMP PUMP GALLONAGE HEATER WEIGHT WEIGHT REQUIREMENTS Qauntum 94
14. epairs to the Acrylic 16 Troubleshooting Guide 17 19 Alternate Use of Water Rainbow 20 www clearcreekspas com www clearcreekspas com www clearcreekspas com www clearcreekspas com The Quantum Plus Portable Whirlpool Spa Installation Instructions The Quantum Plus is a sumptuous rectangular whirlpool spa by Jacuzzi Whirlpool Bath designed with full featured elegance to provide the comfort and luxurious spa experi ence you expect from a Jacuzzi whirlpool spa Multi level contours allow for seating and lounging for 7 people A built in step and handrail allow safe entrance and exit from the spa And for a revitalizing hydromassage six fully adjustable color coordinated whirlpool jets and one directionally adjustable jet are located strategically to massage lumbar and upper back regions depending on where you are seated For the ultimate in convenience the Quantum Plus fea tures two clearly labeled control panels one located on either side of the spa and concealed by a streamlined tinted acrylic cover One panel allows push button control of the heater filter whirlpool lights and air blower functions and adjustment of silent air induction The other control panel offers additional air induction adjustment A 7 day timer located on the System Control Module can be set for automatic control of temperature and filtration The Quantum Plus also features two low voltage lights and interchangeable colored lenses adding even mor
15. ether you install your spa indoors or outdoors you can drain it completely by attaching a garden hose to the drain valve located on the suction tee of the spa Simply run the hose to the house sewer line or drain field and open the drain valve Make sure the area surrounding the spa has good drainage to keep water from collecting at the base of the SUPPORT AND DRAINAGE 8 BOND WIRE TO HOUSE ELECTRICAL PANEL OR LOCAL BOND TO BOND BAR spa especially near the equipment area If drainage is poor install a drain line and or gravel drain field see illustration below Indoor Installations Water which splashes on the floor during use of the spa may cause a walking hazard and or structural dam age unless good drainage is provided and proper water proof building materials are used in the area surrounding and beneath the spa Take into consideration also the high room humidity which will exist due to high spa water temperatures Providing natural or forced ventilation of the room will help maintain comfort and minimize mois ture damage to the building Jacuzzi Whirlpool Bath is not responsible for damages resulting from excess mois ture or water spillage Consult an architect or engineer for aid in designing your indoor installation WIRE MESH GRID 8 x 8 x 4 THICK CONCRETE PAD www clearcreekspas com www clearcreekspas com www clearcreekspas com INSTALLATION Equipment Set Up 1 Remove the plastic shee
16. he six fully adjustable whirlpool jets can be adjusted to control the force of the water coming into the spa For stimulating action increase the force of the flow by rotating the jet handles to the left For a more relaxing effect rotate the handles to the right clockwise The directionally adjustable whirlpool jet located on the wall of the spa opposite the lounger side of the spa can be directed toward any location on the body particularly toward any area that feels tense or stiff The jets are located at various heights around the seating area to allow a hydromassage of the upper or lower back The warmth of the water and the stimulating water flow from the jet will pleasantly increase circulation Or for the total whirlpool effect you can adjust all jets so they point in a clockwise or counterclockwise direction to circulate the air and water mixture in a circular motion all about the spa FULLY ADJUSTABLE WHIRLPOOL JET Silent Air Induction The intensity of the whirlpool action is determined by how much air is inducted into the water You have control of this by adjusting the two air induction control knobs locatedon both control panels For maximum air induction rotate each control knob fully counter clockwise to the largest dot For fewer air bubbles decrease the amount of air induction by rotating the control knob clockwise When the knobs are turned to the smallest dot only water is being circulated Water Rainbow beau
17. l Jacuzzi Whirlpool Bath 510 938 7411 for Warranty Service 510 938 7411 Npte Damage or defects which could have been discovered anr repairedprior to installation and which are claimed after final installation of the spa are excluded from our warrenty Unpacking it vertically on a dolly which is wide enough to support the entire width of the spa The skirt is cosmetic not structural and is not designed to support the spa 1 Remove the outer carton by disassembling bracing 4 When the spa has been moved to its final location and plastic bags Leave the inner bag and corrugated place a wooden block approximately 100mm x 100mm wrapping in place on the skirt to protect the product until x 2m 4 x 4 x 72 beside the pan side of the spa so equipment set up it is parallel with the pallet See illustration 2 Remove the box containing skirt panels and the acces 5 Tip the spa over onto its bottom with the block support sory package which contains the Owner s Manual ing the spa filter cartridges and extra lenses and bulbs Set aside skirt panels until equipment set up Set aside the filter Remove the brackets attaching the spa to the pallet cartridges in a dry place until it is time to set up the spa See detail B equipment Store the extra lenses and bulb for later 7 Remove the bolts securing the pallet to the upper part use of the spa shell 3 The spa should be moved on a dolly in its upright 8 Remove the 100m
18. located in the middle of the door Slide the basket out then pull the filter cartridge upward and out of the housing by the loop at the top of the filter Clean the filter by separating the folds of the filter and spraying with fresh water from a garden hose then reinstall the cartridge in the A rigid spa cover available as an option when in place over the spa will help reduce evaporation and control the amount of debris entering the spa when the spa is not 14 www clearcreekspas com www clearcreekspas com housing and replace the basket reversing the above pro cedure Oils will coat the filters resulting in a reduced flow To remove such materials soak the cartridges in a plastic pail containing a commercial filter cleaning solution available from most pool supply stores Follow the manufacturer s instructions for use Another method is to soak the filter cartridges in a plastic pail containing a mild solution of tri sodium phosphate TSP and water An hour of soaking time is usually required to break down oil coatings from the cartridge Use a stronger solution of TSP and water to remove algae Most hardware or paint stores stock TSP Use the same method of cleaning when cartridges become clogged with clay or vegetation Replacement cartridges P N 6199000 are available through your dealer www clearcreekspas com www clearcreekspas com MAINTENANCE Automatic Filtration Maintenance If you plan to be away yo
19. may cause a fire Read manufacturer s safety information provided with all optional equipment Save These Instructions for Future Use Owner s Record Date Purchased Purchased From Installed By Spa Serial Number Model 7700000 See page 2 for location of serial number www clearcreekspas com www clearcreekspas com The Quantum Plus Portable Whirlpool Spa Owner s Manual Model 770000 Contents Installation Instructions 3 6 Inspection and Shipping Claim 3 Unpacking 3 Positioning Your Spa 4 Electrical Requirements 4 Electrical Precautions 4 Outdoor Installation 5 Drainage 5 Indoor Installations 5 Equipment Set Up 6 Operating Instructions 7 11 Basic Control Set Up 7 Setting the Time 8 Controls 9 Temperature Control 10 Setting the Thermostat 10 Note on Determining Water Temperature 10 Normal Operation 11 Whirlpool System 11 Water Rainbow 11 Air Blower 11 Silent Air Induction 11 Filtration 11 Maintenance 12 16 Water Quality and Water Chemistry 12 Filtration 12 Water Chemistry 12 Disinfecting 12 Balancing pH 13 Balancing Total Alkalinity 13 Water Quality Definitions 13 Water Level Drain 14 Skimmer Basket Maintenance 14 Filter Maintenance 14 Automatic Filtration Maintenance 15 Winterizing 15 Factory Installed Redwood Skirt 15 Spa Light 16 Cleaning Your Spa 16 Covering Your Spa 16 R
20. mx 100mm 4 x 4 block and pallet position while still attached to its shipping pallet If the and carefully lower the spa to a horizontal position pallet must be detached before the spa is moved for example to allow it to pass through a door detach it 9 Attach two loose skirt panels included in skirt box from the pallet as instructed below then carefully place 10 Record the spa serial number on the inside front cover of this manual See illustration on page 2 for the serial number location Important Read all the instructions contained in the Owner s Manual before beginning installation SKIRT DETAIL 4 X 4 X 7 BLOCK www clearcreekspas com www clearcreekspas com INSTALLATION Important Read complete instructions before beginning installation Positioning Your Spa Because your Quantum Plus spa is a portable you can locate it just about anywhere you wish on a deck patio or even indoors Just be sure to position it above ground in an area with good drainage and on a level continuous surface which can support the weight of the spa when filled with water and people this weight is approximately 5252 Ibs 92 Ibs per sq ft You must also provide access to the spa s equipment for service and general maintenance SERVICE ACCESS Electrical Requirements Your Quantum Plus as it comes from the factory requires a 230 VAC 50 AMP 4 wire grounded type electri cal service and must be in a se
21. ng the dial all the way counterclockwise 3 Maintain a chemical balance See Water Quality section 4 Keep the spa covered FACTORY INSTALLED REDWOOD SKIRT DOUBLE ROW OF STAPLES DENOTES TOP OF SKIRT 15 www clearcreekspas com www clearcreekspas com MAINTENANCE Spa Light Two lenses one blue and one red are provided with your spa To change the lens simply pull the lens out of the fitting and replace it with the desired colored lens Two replacement bulbs GE Model 912 12W 12V are also included Put them in a safe place for future use When a bulb burns out replace it from the back of the light fitting pulling out the bulb receptacle SPA LIGHT BULB REPLACEMENT NORMAL LOCKING LENS NUT COLORED FILTER LIGHT BULB BULB RECEPTACLE LIGHT BEZEL SHELL Cleaning Your Spa Your Quantum Plus spa shell consists of two layers of plastic materials Its smooth top surface of acrylic is tough and durable and contains concentrated color This is supported by a substantial thickness of fiberglass rein forced polyester resin A catalyst causes a chemical reac tion during manufacture that bonds these layers perma nently into a hard strong material With a minimum amount of care and cleaning your whirlpool spa will look new for years To clean your spa simply use a mild non abrasive liquid detergent isopropyl alcohol or commercially prepared spa cleaner Do not use abrasive cleaners You can
22. parate circuit having no other appliance connected in that circuit If you do not have this kind of circuit a qualified electrician should be called in to install the necessary wiring Inadequately sized wiring or locating the spa too far from the main service panel may cause a voltage drop which might cause the unit to malfunction and bring about permanent damage to the spa s electrical system The circuit must also have a ground wire in order to take advantage of the designed in safety features of the spa Bond according to procedure described on the next page Caution Without proper grounding and bonding a system malfunction may cause fatal shock www clearcreekspas com www clearcreekspas com www clearcreekspas com www clearcreekspas com INSTALLATION Electrical Precautions CAUTION Do not apply electrical power to the spa unless it is filled with water to the normal water level which is approximately 7 below the spa rim See location of water level indicator on face of skimmer on page 6 If the spa s motor pumps are actuated when there is not sufficient water in the unit the circulation pumps could be irreparably damaged In addition to damaging the unit operating the unit with insufficient water could cause a fire Do not locate lighting fixtures directly above the spa lighting and electrical receptacles must be located at least 5 ft 1 5m from the spa Lighting located between and 5 ft 1 5m and 10 ft 3m f
23. protect and restore the gloss to a dulled surface by applying a plastic polish specifically designed for use on acrylic fin ishes methylmethacrylate If an acrylic polish is not available an automotive paste wax will do Use a spa cleaner for residue buildup at the water level of the spa surface This may be applied to the acrylic surface with a soft cloth and wiped clean Use sparingly in small amounts to avoid contaminating the spa water If heavily soiled it may be advisable to lower the water level 2 to 3 inches before cleaning then refill to normal level Covering Your Spa An optional rigid spa cover is available to place on top of the spa Use of this cover will help to minimize heat loss and evaporation and thus reduce energy costs The cover is also an attractive and efficient means of preventing debris such as leaves and dirt from entering your spa when not in use Follow the instructions for use and care provided with the spa cover CAUTION While the spa cover is rigid it is not designed to support any weight Therefore as a safety precaution and to preserve the life of your cover you must not sit stand or lie on it nor should you place objects of any kind on top of it Jacuzzi Whirlpool Bath does not guarantee or warrent this cover QUANTUM SPA WITH RIGID INSULATING COVER Repairs to the Acrylic Minor scratches which do not penetrate the color finish acrylic can be removed with 600 grit we
24. r 11 www clearcreekspas com www clearcreekspas com MAINTENANCE Maintenance Water Quality and Water Chemistry Maintaining water quality and water chemistry in your spa is extremely important and should be a regular part of your spa maintenance program as a neglected spa can be a breeding place for dangerous bacteria The water quality of your spa is maintained by a combination of filtration and chemistry The spa s integral filter system helps maintain the water cleanliness and clarity by trapping most solid materials such as body oils hair and other debris resulting from normal use However the most important part of maintaining water chemistry is keeping the proper level of disinfectant in the water at all times This is accomplished by adding chlorine or bromine to the water which will control particles too small to be trapped by the filter such as bacteria and algae and will oxidize any organic materials Follow instructions provided here and with water quality products for the health and safety of spa users as well as to make your spa bathing as enjoyable as possible Filtration The filtration system of your spa will keep your water clear and clean if used properly We recommend that you run your filter system for at least two hours each day The filter cartridge elements will trap most solid materials and debris in the water However the presence of materials such as body oils or other particles which are too small
25. rcreekspas com A Turn on power at service panel B Select FILTER HTR FILTER or JETS mode C Reset circuit breaker D Reset circuit breakers E Reset ELCB 18 www clearcreekspas com www clearcreekspas com www clearcreekspas com TROUBLESHOOTING GUIDE PROBLEM 10 Motor will not start Continued 11 Motor stops 12 Air Blower does not operate PROBABLE CAUSE F Improper or defective wiring G High temperature safety switches tripped H Subnormal voltage 1 Locked shaft or impeller J Motor windings burned out K Defective starting switch inside motor A Motor overload condition B Selector switch failure C Relay failure D Inadequate supply wiring E High temperature safety switches tripped A Power off B ACC switch in OFF C House circuit breaker tripped no power to system D ELCB tripped Faulty motor D E Note The skills and tools necessary for the safe repair of this spa require the services of qualified service personnel Contact your Jacuzzi Whirlpool Bath dealer www clearcreekspas com om REMEDY Reset buttons on heater after water has cooled see Note if switches continue to trip Call an electrician or your power company Let cool for one hour Motor overload protector will reset if problem persists see Note Consult electrician to cor rect wiring to unit Reset bu
26. rden hose fill the spa with water to the Yourspaisprovidedwith a earth leakage circuit breaker waterline indicator mark on the skimmer frame See ELCB At initial start up and at least once a month page 20 for information on using Water Rainbow as a thereafter with power on push the button located on fill spout if desired the spa System Control Module The switch should Atthe house service panel turn on the circuit breaker move to the OFF 0 position Move the switch to the or switch that controls the electrical service to your spa ON 1 position to reset If the interrupter fails to operate in this manner there is a ground current flowing or a Make sure there is no other appliance on that circuit M device malfunctioning indicating the possibility of elec Opentheskirtdoorgiving access tothe System Control tric shock Turn off power and do not use the spa until Module the source of the breakdown has been identified and corrected SYSTEM CONTROL MODULE PLUG IN 7 CONNECTORS OPENING DOOR VOIDS WARRANTY THIS EQUIPMENT REQUIRES QUALIFIED SERVICE 4 PERSONNEL FOR PROPER REPAIR CONTACTYOUR JACUZZI WHIRLPOOL BATH DEALER FOR SERVICE 1 CAUTION DO NOT BREAK DOOR SEAL ted bn NO USER SERVICABLE FARTS BEHIND THIS DOOR www clearcreekspas com www clearcreekspas com www clearcreekspas com www clearcreekspas com OPERATION Basic Control Set Up continued Make sure th
27. rine or bromine to add and determine how often you need to add it We recommend that you maintain a free chlorine level of 2 0 to 5 0 ppm at all times except when you must exceed that during the initial purge sanitizing procedure or during superchlorination See Water Quality Definitions below Superchlorinate your spa every two weeks with heavy use If using sodium dichlor add 15cc 1 tablesoon for each 565 ltrs 150 gallons of spa water Scrub the surfaces with this solution to remove any oily deposits This will ensure that any bacteria or algae which are resistant to the normal disinfectant level are killed After adding the disinfectant run the filter system and allow the free chlorine level to www clearcreekspas com www clearcreekspas com MAINTENANCE Water Chemistry Disinfecting continued return to the 2 0 to 5 0 ppm range before using the spa again Do not install a rigid cover during this procedure until the disinfectant level is back to normal High concentra tions of chlorine or bromine will damage metallic plated finishes if the cover is in place Balancing pH For good hygiene and longevity maintain the pH of your spa water according to the instructions provided pH is the measure to determine if the spa water is too acid low pH or too alkaline or basic high pH The ideal range for spa water is 7 2 to 7 6 pH For excessive acidity below 7 2 pH add soda ash or sodium bicarbonate to the spa water For
28. rn on circuit breakers at the main electrical panel Select JETS the SYSTEM switch Add 60cc sodium dichlor a fast dissolving granulartype of chlorine to the water and let the whirlpool run for 15 20 minutes only Turn off JETS Turn off circuit breakers Immediately open the drain valve and drain the spa completely CAUTION Leave the rigid cover off the spa during this procedure Do not use the spa during this procedure Drain the spa immediately afterward 8 10 11 12 Close the drain valve and fill the spa with water to approximately 180mm 7 below the spa rim or to water line indicator mark the skimmer frame See illustration on this page Turn on circuit breakers at the main service panel Set the heater thermostat for the maximum tem perature Test the spa for proper operation Operating Instructions Refer to Refer to Water Quality section of the Operating Instructions Test for water quality then add treatment chemicals to ensure proper levels All Jacuzzi Whirlpool Bath spas are factory tested for proper operation and watertight connections prior to shipping If leaks or other problems are detected immediately notify your Jacuzzi Whirlpool Bath dealer or Authorized Service Agent or call Jacuzzi Whirlpool Bath 510 938 7411 510 938 7070 in California for Warranty Service www clearcreekspas com www clearcreekspas com SKIMMERIFILTER a DOOR SKIMMER PANE
29. rom the spa must be on a circuit protected by a ELCB See National Electrical Code 680 6 Do not use electrically connected devices such as television radio telephones stereo speakers lights or cooking devices within 5 ft 3m of the spa when the spa is being used All fixed metal objects located within 5 ft 1 5m of the spa such as fence posts railings door frames green house structures gutters etc must be attached to the bonding bar on the outside of the spa System Control Module using 8 solid copper wire With 8 solid copper wire bond the spa to the house electrical panel or approved local earth electrode An approved earth electrode may be an 8 ft long earth rod a plate electrode or a buried metal water pipe with atleast 10 ft of buried pipe Check your local building code for requirements Bonding lugs are avail able at your local electrical supply store Bond bar location is shown on page 5 Outdoor Installation If you install the spa outdoors we recommend that you provide a concrete pad for it to rest on To do this construct forms for a 8 x 8 x 4 thick level pad Install a 10 gauge wire mesh approximately 6 x 6 steel reinforced grid Attach a 8 solid copper wire to the grid with aground clamp This wire should be long enough to reach the bond bar on the spa System Control Module min 36 but should not be located under the base of the spa Then pour the concrete pad Drainage Wh
30. t covering the spa Use care stepping into the spa with shoes will scratch the acrylic surface Remove any packing materials from the spa Remove each filter cartridge from its plastic bag Pull open each skimmer filter door by the handle lo cated in the middle of the door and remove the skimmer basket Then insert the filter cartridge into the filter housing and re insert the basket so that it fits in place over the filter cartridge and close the skimmer filter door Clean the interior of the spa of any remaining construc tion debris Remove stubborn stains paint or tar with turpentine isopropyl alcohol or paint thinner A mild liquid dishwashing detergent on a damp cloth is fine for cleaning off other dirt Plaster can be removed by scraping with a wooden edge do not use a metal scraper wire brush or other metal tools as they will damage the spa s surface Install the skirt panels which were not installed on the spa at the factory To do this secure with the screws provided in your spa accessory package and follow instructions provided with panels On initial start up it is necessary to purge and sanitize the system Carefully follow the procedure described here to purge and sanitize your spa Remove the spa cover completely Close the drain valve located on the suction tee Fill the spa with water to its normal operating level which is to the water level indicator mark on the skimmer filter frame e Tu
31. t dry sandpaper Restore the glossy finish with an acrylic polish or a compa rable automotive paste wax Major scratches or gouges which penetrate the acrylic surface will require refinishing Ask your Jacuzzi Whirlpool Bath dealer for special instructions www clearcreekspas com 16 www clearcreekspas com www clearcreekspas com www clearcreekspas com TROUBLESHOOTING GUIDE PROBLEM 1 Control Switches do not respond Heater not functioning PROBABLE CAUSE A Actuated too rapidly B No power to the unit B Heater mode not selected No power to heater Thermostat set lower than water temperature D High temperature safety switches tripped REMEDY A Wait 60 seconds system will be restored automatically B Turn on circuit breakers select Heater Filter mode B Check house circuit breaker C D and ELCB Turn to desired temperature Reset buttons on heater after water has cooled see Note if E Abnormally low water flow switches continue to trip F Heater relay not operating E See Remedy 6 below G Heater element failure Flow switch not operating G H Check Flow switch and plug in connection on System Control Module 3 Heater not functioning but A Relay malfunction A heater light on B Element malfunction B C Loose wires 4 Water not clean A Clogged or blocked suction A Clean strainer skimmer basket strainer
32. th a rigid spa cover 6 Before using the spa again review the Operating In structions Factory Installed Redwood Skirt Your Quantum Plus spais supplied with a factory installed redwood skirt which completely surrounds the spa The door can be opened for routine maintenance setting the timer and for testing the ELCB before use The skirt is made of kiln dried redwood and can be left natural to weather or you may choose to apply a stain or clear finish Consult your local paint dealer for the appropri ate product NOTE WE RECOMMEND A WATER BASED MATERIAL OIL OR SOLVENT BASED FINISHING MA TERIALS DEGRADE THE SKIRT BACKING MATERIAL It may become necessary to remove one or more of the skirt panels for major service access but all the panels must be securely in place during use of the spa To detach any of the panels first remove all screws from the panel being detached The panels can be re attached to the spa by reversing the above procedure www clearcreekspas com www clearcreekspas com CAUTION Not winterizing will cause irreversible dam age at freezing temperatures to the pump and or plumbing lines Note Ifthe spais to be used during winter in a cold climate see warm climate instructions below In a warm climate where there are occasional freezing temperatures follow this procedure 1 Select the HTR FILTER mode 2 Set the thermostat to its minimum temperature 7 to 10 C 45 to 50 F by turni
33. the HEATER CONTROL knob turned to its lowest set ting the water will be filtered without heat during the time period set on the timer Close the redwood skirt door CIRCUIT BREAKER BUTTONS a MIN Note that the timed www clearcreekspas com www clearcreekspas com TIMER PUSH IN ONE TAB FOR EACH TWO HOUR PERIOD OF OPERATION www clearcreekspas com www clearcreekspas com OPERATION Controls A switch panel giving you convenient control of the whirlpool filter heater filter blower and light is located under the tinted acrylic cover on the rim of the spa ACC Accessory The ACC Accessory switch controls these functions in this sequence 1 OFF To ensure your safety and allow easy operation your 2 AIR spa is equipped with two air activated switches One the SYSTEM switch controls the whirlpool jets heat and filtration The other switch ACC Accessory controls the 4 LIGHT air blower and the light System The SYSTEM switch controls the following four func tions in the continuous sequence indicated THERMOMETER 1 OFF TEMPERATURE 2 JETS READOUT 3 HTR FILTER 4 FILTER The next selection is OFF again Use the JETS function as a reference to indicate your location in the function sequence since that function is the most obvious when operating For best performance and increased equipment life pause a second or two between pushbutton selections BATTERY CONTROL PANEL OFF JETS
34. tiful cascades of shimmering water for an exciting visual effect The Water Rainbow spouts will add the soothing sound of a waterfall to your bathing pleasure as well as providing www clearcreekspas com www clearcreekspas com Activate the waterfall feature by first turning on the JETS HTR FILTER or FILTER function then rotate downward the flow control lever located on the left side of the spout Use this lever to adjust the amount of water flowing through the Water Rainbow spout The waterfall effect will be greatest in the JETS mode Turning off the flow at the fully adjustable jets will dramatically increase the Water Rain bow flow CAUTION water circulating through the Water Rainbow spouts is not fresh water and therefore is not suitable for drinking WATER RAINBOW SPOUT Air Blower The Quantum Plus features a built in air blower and factory drilled air holes in the seats of the spa The blower sends air to a channel located under the spa s seats this air is distributed through the air holes and as the pressurized air is released from the holes tiny bubbles are formed These bubbles travel upward through the water and expand until they reach the surface and burst The exciting visual effect of the bursting bubbles contrib utes to the overall hydromassage experience onata raene everyday Maintain the waterlevel to the indicator mark on the skimmer filter frame See page 8 for instructions on setting time
35. trainers located in the foot well area should be checked at least once a week for collected debris such as leaves hair etc and cleaned as necessary It may not be necessary to remove the strainer to clean it but should you need to remove the center screw with a Phillips type screwdriver and clean the strainer by flushing with water from a hose CAUTION Be sure to replace the suction strainer immediately after cleaning It is a safety device and must be in place over the suction fitting to minimize potential hazard of hair and body entrapment If heavy rains raise the spa water level drain the spa to its normal level occupied In addition its use will reduce energy con sumption Skimmer Basket Maintenance The basket located in each skimmer of the spa should be checked at least once a week for collection of debris such as leaves hair etc and cleaned as necessary To clean the basket remove it from the skimmer by pulling it out then backflush it with a garden hose and re install FRONT ACCCESS SKIMME FILTER SKIMMER BASKET AA WEIR FILTER CARTRIDGE I Filter Maintenance The filters should be checked periodically In normal use check the filters at least once a month Keep the filters clean obstructed filters reduce water quality and inhibit proper system performance removable filter cartridge is located inside each skim mer To remove it pull open the skimmer door by the handle
36. trol heat loss from the water surface and thereby reduce energy consumption You can improve the spa s heat retention by keeping the spa cover in place on the spa while heating the water Note on Determining Water Temperature As spa products generally perform in a narrow range of operating temperatures we recommend that you use a medical clinical type thermometer for an accurate mea surement of spa water temperature Other types of ther mometers generally available such as those used for swimming pools are not sufficiently accurate for determin ing spa water temperatures Take water temperature readings in the HTR FILTER mode when the heater has just turned off the indicator lamp on the control panel will turn off at this time WATER RAINBOW FLOW CONTROL LEVER s 10 www clearcreekspas com www clearcreekspas com www clearcreekspas com OPERATION Normal Operation Whirlpool System You can enjoy the Quantum Plus spa with or without activating the whirlpool Either way bathing in your spa can be pleasurable as well as therapeutic After a busy stressful day you can look forward to soaking in your spa in still water with no turbulence only the gentle warmth of the soothing and relaxing water For a more invigorating spa experience you can take advantage of the built in whirlpool system To do this push the SYSTEM switch button to select the JETS mode Sit or recline in the spa so you are comfortable T
37. try by testing your spa water every day and adjusting the chemical balance frequently Obtain a water quality test kit designed espe www clearcreekspas com www clearcreekspas com cially for spas The test kit must be of the type which allows you to test for the disinfectant chlorine level pH and total alkalinity Make sure that chemicals used in your spa are especially for spa use and not for swimming pools as water quality maintenance of spas and swimming pools is very different Set up a daily program at first to check the disinfectant level pH and total alkalinity of the water to familiarize yourself with the amount of chemicals to add and to deter mine how often to make chemical adjustments during normal use Remember that the more heavily the spa is used the more often you must check the water chemistry When adding any chemicals always run the filter system to ensure complete dilution with the water Do not add chemicals directly into the skimmer opening Disinfecting When filling the spa for the first time follow the purge sanitizing instructions in the Equipment Set Up procedure 12 of the Installation Instructions Add a disinfectant to the water on a regular basis to help control the amount of bacteria algae and organic materials Such bacterial contaminants if not controlled could cause skin rashes or other physical problems To disinfect the spa for normal use first establish the amount of chlo
38. ttons on heater after water has cooled see if switches continue to trip Turn on power at service panel Select other function Reset circuit breaker Reset ELCB www clearcreekspas com www clearcreekspas com 19 www clearcreekspas com Alternate Use of Water Rainbow Spout as Fill Spout You can use your Water Rainbow spout as a fill spout by permanently plumbing it to a fresh water supply if local codes permit Local plumbing codes may require the use of an anti siphon valve for such a connection Do not interconnect water supply with recirculating system of the spa To make the connections necessary to use the Water Rainbow as a fill spout follow this procedure Make sure spa is unplugged and completely drained Unscrew the spout from the 3 4 pipe Cut 3 4 piping as shown in illustration below Cap off the piping by cementing a 3 4 PVC cap where cut has been made Connect permanent plumbing line to the spout WATER RAINBOW SPOUT INSTALL AND CEMENT 3 4 PVC CAP www clearcreekspas com 20 www clearcreekspas com www clearcreekspas com www clearcreekspas com PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT Jacuzzi Whirlpool Bath has obtained applicable code standards listings generally available on a national basis for products of this type Itis the responsibility of the installer owner to determine spe
39. ture of approximately 7 10 C 45 50 F its lowest setting This does not necessarily protect the spa from freezing See page 15 for winterizing procedures Setting the Thermostat You will notice by the indicator light that the heater is on when the water temperature falls below the desired tem perature and will turn off when that temperature has been reached When the spa is not in use you can set the thermostat to a lower temperature then when you wish to use the spa adjust the TEMP CONTROL knob to the desired tempera ture The water temperature will rise at a rate of about 2 C QUANTUM SPA CONTROLS TEMPERATURE CONTROL KNOB THERMOMOTER SYSTEM SWITCH ACCESSORY SWITCH www cleard per hour with the optional spa cover foam insulation and skirt panels in place and if the air temperature is 10 C 50 F orwarmer This rate will necessitate a waiting period before using the spa the length of which will be determined by the temperature of the water before turning on the heater For example if the water in the spa is kept at about 21 C 70 F when the spa is not in use and the desired temperature is 38 C 100 F it will take about 8 5 hours to heat up sufficiently Once you have determined the desired setting on the thermostat knob it is not necessary to change or readjust it again during normal operation unless you decide on a different setting The optional spa cover available for your spa will help con
40. u should maintain minimum water quality by running the filter system To do this set the timer to turn the system on for at least two hours each day This will cause the filter system to turn on at a desired time Set the timer according to instructions on page 8 with the SYSTEM switch OFF If you will be away for an extended period however we recommend that you drain the spa following the procedure described under Winterizing on this page as long periods without maintenance of water quality could be detrimental to the spa Another means of maintaining minimum water quality while away for less than two weeks is to follow the procedure outlined for winterizing your spa in a warm climate We do not recommend using this procedure more than 1 week during the summer when algae build up is most likely Always keep your spa covered when not in use to reduce heat loss and evaporation and to prevent debris from falling in Winterizing In a climate where winter temperatures are below freezing follow this procedure when the spa will NOT be used 1 Select the OFF mode 2 Turn off power to the unit at the house circuit breaker 3 Drain the spa completely by attaching a garden hose to the hose bibb on the suction plumbing Then remove the hose and leave the hose bibb open to completely drain the spa Close the hose bibb 4 Remove the filter cartridges clean them and store them dry 5 Keep water and debris out by covering wi
41. water is high above 150 ppm it is advisable to drain the water from the spa and begin the balancing process over again Low total alkalinity below 60 ppm could be corrosive and damage your spa system Superchlorination also referred to as shock treatment The addition of an above normal level of disinfectant to kill any bacteria or algae that might have become resistant to normal levels of disinfectant www clearcreekspas com www clearcreekspas com 13 www clearcreekspas com MAINTENANCE Water Level Drain The water level in the spa must be maintained at its normal level Evaporation and splashing will cause the water level to drop When concentrations of impurities from evaporation water quality chemicals body oils perfumes dirty feet and winds etc accumulate in the spa and cannot be filtered out it is necessary to drain your spa and refill it with fresh water This should be done every 2 months or more often depending on the amount of use To drain the spa turn all controls to OFF Then turn off circuit breakers at the main electrical panel Connect a garden hose to the hose bibb in the suction plumbing Turn the handle and drain the spa After draining the spa clean the spa shell suction strainers skimmers and filters then close the hose bibb and refill the spa with fresh water Check the pH level and maintain water quality NORMAL WATER LEVEL WATER LEVEL INDICATOR MARK The suction s