Home

Westinghouse 52-Inch Instruction Manual

image

Contents

1. 14 Mantenimiento 15 Troubleshooting 14 Soluci n de problemas 15 UL ES XavierII WH09 2 UL ES XavierII WH09 PREPARATION PREPARACI N Before beginning assembly installation or operation of product make sure all parts are present Compare parts with the Parts Reference List Estimated Assembly Time 35 minutes standard installation Tools Required for Assembly Phillips Screwdriver Step Ladder not included Antes de comenzar el montaje la instalaci n o la operaci n de este producto compruebe que contenga todas las piezas requeridas Aseg rese de que las piezas corresponden a la Lista de piezas con letras de referencia Tiempo estimado de montaje 35 minutos instalaci n est ndar Herramientas necesarias para el montaje Destornillador Phill
2. 3 Parts Reference List 4 Lista de piezas con letras de referencia 4 Installation Instructions 6 Instrucciones de instalaci n 6 Operation 14 Operaci n 15 Maintenance
3. OPCI N DE INSTALACI N AL RAS OPCI N DE INSTALACI N AL RAS Si elige la opci n de montaje al ras proceda al paso 6 NORMAL Si instala la varilla vertical incluida con el ventilador proceda al paso 9 OPCI N CON VARILLA VERTICAL M S LARGA Si instala una varilla vertical m s larga que la que se incluye con el ventilador proceda a la p gina 8 paso 11 6 Guide motor wires through the base of the canopy as shown Attach canopy G to motor housing A using three ush mount screws U and lock washers W previously removed Tighten screws securely Deslice los cables del motor a trav s de la base del dosel como se indica Fije el dosel G al alojamiento del motor A con los tres tornillos de montaje al ras U y las arandelas de presi n W que extrajo previamente Apriete los tornillos asegur ndolos G U W 7 Choose a mounting option Elija una opci n de montaje 8 FLUSH MOUNT INSTALLATION For ush mount option raise fan assembly and place onto hook from mounting bracket C into a closed hole on the canopy G This will allow for hands free wiring PROCEED DIRECTLY TO PAGE 9 STEP 14 FOR WIRING OPTIONS Para la opci n de montaje al ras levante el montaje del ventilador col quelo sobre el gancho de la placa de montaje C y cu lguelo en uno de los agujeros cerrados del dosel G De este modo tendr las dos manos libres para hacer el cableado PARA LAS OPCIONES DE CABLEADO PROCEDA DIR
4. From Fan From House connect connect connect connect Attach blue wire only if attaching light kit with fan Wall Control Follow diagram above to make wiring connections for wall control operation NOTE A professional electrician is recommended for this type of installation White common Black hot Blue hot Main ground White common Black hot Green ground From Fan From House connect connect connect Attach blue wire only if attaching light kit with fan Follow diagram above to make wiring connections for fan pull chain control PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION wall control switch not included Blanco com n Negro vivo Azul vivo Principal tierra Blanco com n Interruptor del ventilador vivo Interruptor de la luz vivo Verde de tierra Del Ventilador De La Casa conectar conectar conectar conectar Conecte el cable azul s lo si conecta un juego de luces al ventilador Control de pared Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador con control de pared NOTA Se recomienda que use los servicios de un electricista profesional para este tipo de instalaci n Blanco com n Negro vivo Azul vivo Principal tierra Blanco com n Negro vivo Verde de tierra Del Ventilador De La Casa conectar conectar conectar Conecte
5. Press the light button on the wall control off and on once to reset the light fixture for fans with Remote Controls If you verify the wattage and the lights do not turn on press the light button on the remote control twice to reset the light fixture NOTE If the procedures above do not reset the lights turn off the main power source located at the breaker panel or box and then turn it on again 14 UL ES XavierII WH09 Troubleshooting Guide Operation Turn on the power and check operation of fan The pull chain controls the fan speeds as follows 1 pull high 2 pulls medium 3 pulls low 4 pulls off Speed settings for warm or cool weather depend on factors such as room size ceiling height number of fans and so on The slide switch controls direction forward or reverse Warm weather Forward Fan turns counterclockwise direction A downward air flow creates a cooling effect as shown in illustration A This allows you to set your air conditioner on a higher temperature setting without affecting your comfort Cool weather Reverse Fan turns clockwise direction An upward airflow moves warm air off the ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in Safety Tips when operating in this position NOTE Turn off and wait for fan to stop before changing the setting of the forward reverse slide
6. s alta sin que afecte su comodidad Clima fr o Atr s El ventilador gira en sentido de las agujas del reloj Una corriente de aire ascendente aleja el aire caliente del rea del ventilador de techo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de seguridad cuando utilice el ventilador en esta posici n NOTA Apague el ventilador y espere a que se detenga antes de cambiar la direcci n de adelante atr s con el conmutador de tipo deslizante Mantenimiento 1 El movimiento natural del ventilador podr a hacer que se aflojen algunas conexiones Verifique las conexiones de soporte las piezas de fijaci n y los accesorios de las paletas dos veces al a o Cerci rese de que est n aseguradas 2 Limpie el ventilador peri dicamente para ayudar a mantener su apariencia nueva con el correr de los a os No use agua para limpiarlo ya que podr a da ar el motor o la madera o causar descarga el ctrica 3 Use s lo un cepillo blando o un trapo sin pelusa para no rayar el acabado El enchapado est sellado con una capa de laca para minimizar la decoloraci n o p rdida del brillo 4 No hay necesidad de aceitar el ventilador El motor tiene cojinetes de lubricaci n permanente Gu a para solucionar problemas PRoBLEMA Si el ventilador no arranca Si el ventilador es rui doso Si el ventilador
7. se vende por separado 4 UL ES XavierII WH09 PARTS REfERENCE LIST LISTA dE PIEZAS CoN LETRAS dE REFERENCIA Part Description Quantity NOTE The reference list below assigns a letter to each part referenced in the assembly instructions Use this reference as both a descriptive listing as well as designation of the parts final location NoTA La siguiente lista asocia una letra de referencia con cada pieza que se menciona en las instrucciones de montaje Adem s de ser un listado descriptivo este recurso indica tambi n la ubicaci n final de las piezas A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE FF Part Description Quantity Pieza Descripci n Cantidad A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA BB CC DD EE FF Pieza Descripci n Cantidad Motor 1 Blade 5 Mounting Bracket attached to canopy 1 Downrod Ball 1 Down Rod 1 Canopy Cover Ring 1 Canopy 1 Coupling Cover Blade Bracket 5 Light Kit 1 Switch Housing 1 Coupling attached to motor 1 Pull Chain amp Fob in hardware bag 2 Blade Balance Kit 1 Motor Gasket in hardware bag 5 Blade Bracket Screws in hardware bag 18 Clamp Pin attached to downrod 1 Cross Pin attached to downrod 1 Blade Bracket Fiber Washers in hardware bag 18 Cross Pin in downrod ball 1 Flush Mount Screw in motor and hardware bag 4 Motor Screw in motor an
8. blade bracket screws P and fabric washers S Fije los soportes para paletas I a las paletas B con los tornillos P y las arandelas de tela S S P Remove one of the screws on the switch housing plate and loosen do not remove the other two Quite uno de los tornillos de la placa del alojamiento del interruptor y a oje los otros dos sin sacarlos del todo 19 F B I 11 UL ES XavierII WH09 20 21 Insert the wires from the motor through the hole in the switch housing and connect the wires in switching housing to the wires from motor using the 9 pin molex plug Pase los cables del motor a trav s del ori cio del alojamiento del interruptor y use el conector molex de 9 pines para conectar los cables del alojamiento del interruptor a los cables del motor Attach the switch housing K to the switch housing plate by placing the keyslot holes from the switch housing onto the two protruding screw heads on the switch housing plate Twist the switch housing until the screwheads engage the keyslots Install screw removed from switch housing plate step 22 into the closed hole in the switch housing Tighten all screws to complete attachment of the switch housing Fije el alojamiento del interruptor K a la placa correspondiente colocando las ranuras bocallaves del alojamiento sobre las dos cabezas de los tornillos que sobresalen en la placa del alojamiento Gire el alojamiento del interruptor hasta que las
9. from downrod E by removingset screw AA Slide downrod ball D o of downrod and remove pin T A oje la esfera de la varilla vertical D de la varilla vertical E quitando el tornillo AA Deslice la esfera de la varilla vertical D hasta separarla de la varilla vertical y quite el pasador T D T E D AA H Q R Z 12 E L 9 UL ES XavierII WH09 14 15 Carefully lift fan assembly onto mounting bracket C Rotate fan until notch on downrod ball D engages the ridge on the mounting bracket C This will allow for hands free wiring With bracket holding fan assembly make electrical connections using the following step for wiring instructions Make sure that all exposed wiring is secured inside wire nuts BB Levante con cuidado el conjunto del ventilador hasta el soporte de montaje C Gire el ventilador hasta que la muesca de la bola de la varilla vertical D calce sobre la saliente del soporte de montaje C De este modo tendr las dos manos libres para hacer el cableado Con la pieza de montaje sujetando el conjunto del ventilador haga las conexiones el ctricas de acuerdo a las siguientes instrucciones de cableado Aseg rese de que todos los cables expuestos est n asegurados dentro de los conectores tipo tuerca para cables BB C C D BB 13 White common Black hot Blue hot Main ground White common Fan Switch hot Light Switch hot Green ground
10. o limpieza en la unidad apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accidentalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio 16 Antes de realizar la instalaci n es importante comprobar y volver a ajustar todos los tornillos seg n corresponda 3 UL ES XavierII WH09 fEATURES CARACTER STICAS Combo Blades feature two high quality finishes on one blade Select the one that best complements your decor or change the style with just a flip of the blade NOTE Combo Blade finishes vary depending upon model Las aspas del rotor de doble cara presentan dos superficies con un acabado de alta calidad Invirtiendo las aspas puede Ud producir un efecto decorativo adaptado a su ambiente o crear una decoraci n completamente nueva Observaci n las superficies de las aspas de doble cara son distintas en funci n del modelo COMBO BLADE ASPAS dE doBLE CARA DOWNROD INSTALLATION INSTALACI N CoN VARILLA VERTICAL For normal ceilings Para cielorrasos normales VAULTED CEILING INSTALLATION INSTALACI N PARA CIELoRRASoS ABoVEdAdoS fLUSH MOUNT INSTALLATION INSTALACI N AL RAS For low ceilings Para cielorrasos bajos May require a longer downrod sold separately Podr a requerir una varilla vertical m s larga
11. rese de que las cadenas est n bien sujetas tirando ligeramente de ambas cadenas en la pieza de uni n 26 23 24 Find the wire plugs from the light kit and from the motor and slide together Connect the blue wire from the switch housing to the black wire from the light kit and the white wire from the switch housing to the white wire from the light kit Identi que los conectores para cables de salida del artefacto luminoso y del motor y desl celos para unirlos Conecte el cable azul del alojamiento deL interruptor al cable negro del artefacto luminoso y el cable blanco del alojamiento del interruptor al cable blanco del artefacto luminoso Attach light kit to the switch housing using three small screws provided Conecte el artefacto luminoso al alojamiento del interruptor con los tres tornillos peque os incluidos FF 13 UL ES XavierII WH09 AVISo Este ventilador que cumple con las exigencias del Energy Policy Act 2005 incluye un accesorio que limita el vataje total de su l mpara a 190 vatios Si usted instala una combinaci n de bombillas que sobrepasen los 190 vatios o si un sobrevoltaje hace que el voltaje sea superior a 190 vatios la l mpara regular la intensidad a 190 vatios o se apagar Para restablecer el nivel de luminosidad aseg rese que el vataje total de las bombillas no sobrepase los 190 vatios y siga las indicaciones aplicables a continuaci n Para ventiladores con Cadenilla de tiro Jale
12. switch Maintenance 1 Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure 2 Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning This could damage the motor or the wood or possibly cause electrical shock 3 Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed with a lacquer coating to minimize discoloration or tarnishing 4 There is no need to oil your fan The motor has permanently lubricated bearings PROBLEM If fan does not start If fan sounds noisy If fan wobbles If light does not work SUGGESTED REMEDy 1 Check main and branch circuit fuses or circuit breakers 2 Check wire connections as performed in step 14 of installation CAUTION Make sure main power is turned off 3 Make sure forward reverse switch is firmly to one side or the other Fan will not operate when switch is in the middle 4 If the fan still will not start contact a qualified electrician Do not attempt to troubleshoot internal electrical connections yourself 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT U
13. 16 All set screws must be checked and re tightened where necessary before installation SAfETy TIPS CoNSEjoS dE SEGuRIdAd OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS HAGA LO SIGUIENTE LEA Y GUARDE ESTAS INSTRUCCIONES WARNING TO REDUCE THE RISK Of fIRE ELECTRIC SHOCK OR PERSONAL INJURy MOUNT TO OUTLET BOX MARKED ACCEPTABLE fOR fAN SUPPORT AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX MOST OUTLET BOXES COMMONLy USED fOR THE SUPPORT Of LIGHTING fIXTURES ARE NOT ACCEPTABLE fOR fAN SUPPORT AND MAy NEED TO BE REPLACED CONSULT A QUALIfIED ELECTRICIAN If IN DOUBT AdVERTENCIA PARA REduCIR EL RIESGo dE INCENdIo dESCARGA EL CTRICA o LESIoNES PERSoNALES MoNTE EL VENTILAdoR EN uNA CAjA dE EMBuTIR RoTuLAdA AdECuAdA PARA VENTILAdoRES Y uTILICE LoS ToRNILLoS dE MoNTAjE INCLuIdoS CoN LA CAjA dE EMBuTIR LA MAYoR A dE LAS CAjAS dE EMBuTIR uTILIZAdAS NoRMALMENTE PARA ARTEFACToS dE ILuMINACI N No SoN AdECuAdAS PARA VENTILAdoRES Y dEBER AN SER REEMPLAZAdAS SI TIENE PREGuNTAS CoNSuLTE A uN ELECTRICISTA CERTIFICAdo 1 El trabajo de instalaci n y el cableado el ctrico los deben efectuar personas calificadas cumpliendo con todos los c digos y las normas aplicables ANSI NFPA 70 1999 incluyendo las de incendio 2 Use esta unidad s lo de la manera en que el fabricante quiere que se haga Si tiene dudas llame al fabricante 3 Despu s de hacer las conexiones empuje con cuidado las conexiones dentro de la caja de em
14. ECTAMENTE A LA P GINA 9 PASO 14 G C C Remove three ush mount screws U and lock washers W from the top of the motor housing A and save for later use Quite tres tornillos de montaje U al ras y arandelas de presi n W de la parte superior del acoplamiento del motor A y gu rdelos para usarlos m s tarde A U W A 8 UL ES XavierII WH09 10 Re install pin T into extended downrod and slide downrod ball D up to the top of the downrod Re install set screw AA to secure ball to downrod Note Some extended downrods have a pre drilled set screw hole If a pre drilled hole is present in the extended downrod tighten the set screw into the pre drilled hole in the extended downrod If no pre drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball PROCEED STEP 9 Vuelva a instalar el pasador T en la varilla vertical m s larga y deslice la esfera de la varilla D hasta el extremo superior de la misma Vuelva a insertar el tornillo de jaci n AA para asegurar la esfera a la varilla vertical Nota Algunas varillas verticales m s largas tienen un agujero previamente perforado para el tornillo Si la varilla vertical m s larga tiene un agujero previamente perforado ajuste el tornillo en el agujero previamente perforado de la varilla vertical m s larga Si la varilla vertical m s larga no tiene un agujero previamente perforado ajuste el tornillo
15. Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia Net Weight 22 5 LBS Peso Neto 9 2 KGS MR byXavier II TM Table of Contents ndice Safety Information 2 Informaci n de seguridad 2 Preparation 2 Preparaci n 2 Features 3 Caracter sticas
16. SE a Solid State variable speed control 4 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 1 Check that all blades are screwed firmly into blade holders 2 Check that all blade holders are tightened securely to motor 3 Make sure that canopy and mounting bracket are tightened securely to ceiling joist 4 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check to see that the wire connections in the switch housing are connected 2 Check for faulty light bulbs 3 If light kit will still not operate contact a qualified electrician for assistance 15 UL ES XavierII WH09 operaci n Encienda el ventilador y verifique su funcionamiento La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera 1 jal n r pida 2 jalones mediana 3 jalones lenta 4 jalones apagado Las velocidades para clima c lido o fr o dependen de factores como el tama o de la habitaci n la altura del ventilador el n mero de ventiladores etc El conmutador de tipo deslizante controla la direcci n hacia adelante o hacia atr s Clima c lido Adelante El ventilador gira en sentido contrahorario Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustraci n A Esto le permite ajustar el aire acondicionado a una temperatura m
17. andela de metal para tornillos para madera 2 Tapa de la estructura del interruptor 1 Bombilla 3 5 UL ES XavierII WH09 A B C D E f G H I J K L O M N P Q R S T U V W X y Z AA CC DD ff BB EE Parts missing or damaged Please visit www westinghouselighting com support Questions or problems installing your fan Please contact your local electrician Hay piezas faltantes o da adas Por favor visite www westinghouselighting com support Tiene preguntas o problemas con la instalaci n de su ventilador Por favor comun quese con su electricista local 6 UL ES XavierII WH09 INSTALLATION INSTALACI N Unpack and inspect fan carefully to be certain all contents are included Quite el envoltorio e inspeccione detenidamente el ventilador para verifi car que todas las piezas est n incluidas Use metal outlet box suitable for fan support must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Turn off power at fuse box to avoid possible electrical shock Apague la alimentaci n en la caja de fusibles para evitar la posibilidad de descarga el ctrica Use una caja de embutir de metal adecuada para soportar un ventilador debe soportar 35 libras Antes de fijar el ventilador a la caja de embutir as
18. cabezas de los tornillos se enganchen en las ranuras bocallaves Inserte el tornillo que extrajo de la placa del alojamiento del interruptor en el paso 22 en el ori cio cerrado de dicho alojamiento Ajuste todos los tornillos para completar la instalaci n del alojamiento del interruptor K 22 NOTE For installation of your ceiling fan without the light kit using the optional switch housing cap continue with step 22 If you are installing your ceiling fan with the light kit proceed to step 23 now NOTA Para instalar su ventilador de techo sin juego de luces usando la tapa opcional para la estructura del interruptor contin e con el paso 22 Si va a instalar su ventilador de techo con juego de luces proceda al paso 23 ahora Attach the switch housing cap using three small screws provided Proceed to page 12 step 26 Conecte la tapa del alojamiento del interruptor con los tres tornillos peque os incluidos Proceda a la p gina 12 paso 26 12 UL ES XavierII WH09 Install light bulbs FF included Instale las bombillas FF de luz incluidas 25 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling Con rm chains are held by lightly pulling both chains in coupling Sujetar las cadenas largas de tiro con las piezas nales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga en la pieza de uni n Aseg
19. d hardware bag 12 Lock Washer in hardware bag 6 Star Washer attached to mounting bracket 4 Screw attached to mounting bracket 4 Set Screw attached to coupling 2 Set Screw attached to downrod ball 1 Wire Nut 3 Wood Screw in hardware bag 2 Metal Washer for wood screws 2 Switch Housing Cap 1 Bulb 3 Motor 1 Aspa 5 Abrazadera de montaje fija al dosel 1 Esfera de la vara 1 Vara 1 Aro de la cubierta del dosel 1 Dosel 1 La Cubierta del Acoplamiento 1 Abrazadera para aspa 5 Juego de luces 1 Estructura del interruptor 1 Acoplador fijo al motor 1 Cadenilla de tiro y remate en la bolsa de herrajes 2 Juego para balancear las aspas 1 Empaque para motor en la bolsa de herrajes 5 Tornillos para la abrazadera de aspa en la bolsa de herrajes 18 Pasador tipo prensa fijo a la vara 1 Pasador transversal fijo a la vara 1 Arandela de fibra para la abrazadera de aspa en la bolsa de herrajes 18 Pasador transversal en la esfera de la vara 1 Tornillo para instalaci n a ras en el motor y la bolsa de herrajes 4 Tornillo para el motor en el motor y la bolsa de herrajes 12 Arandela de presi n en la bolsa de herrajes 6 Arandela en estrella fija a la abrazadera de montaje 4 Tornillo fijo a la abrazadera de montaje 4 Tornillo de fijaci n en el acoplador 2 Tornillo de fijaci n en la esfera de la vara 1 Conector de alambres 3 Tornillo para madera en la bolsa de herrajes 2 Ar
20. dosel y el soporte de montaje est n firmemente asegurados a la viga del cielorraso 4 Si la oscilaci n de la paleta sigue siendo visible es posible que al intercambiar dos paletas adyacentes lado a lado se redistribuya el peso y el funcionamiento sea m s suave 1 Verifique que el conector molex del alojamiento del interruptor est conectado 2 Compruebe si hay l mparas defectuosas 3 Si el conjunto de luces no funciona p ngase en contacto con un electricista calificado Westinghouse Lighting Corporation a Westinghouse Electric Corporation licensee is a registered trademark of Westinghouse Electric Corporation Made in China 2009 Westinghouse Lighting Corporation Westinghouse Lighting Corporation titular de la licencia de Westinghouse Electric Corporation es una marca registrada de Westinghouse Electric Corporation Fabricado en China 2009 Westinghouse Lighting Corporation UL ES XavierII WH09
21. eg rese de que la misma est fijada de manera segura en por lo menos dos puntos a un miembro estructural del cielo raso una caja suelta har a que el ventilador oscile 1 2 4 Install mounting bracket C to outlet box in ceiling using the screws and washers provided with the outlet box Instale el soporte de montaje C a la caja de embutir del cielorraso con la torniller a suministrada con la caja de embutir Remove the screws Y and star washers X from the two mating holes on the canopy G Save these for use in Step 15 Loosen do not remove the screws Y in the mating slots on the canopy G Rotate the mounting bracket C and remove from the canopy G Quite los tornillos Y y las dos arandelas en estrella X de los dos orificios coincidentes del dosel G Gu rdelos para usarlos en el paso 15 Afloje no quite los tornillos Y de las ranuras coincidentes del dosel G Gire el soporte de montaje C y sep relo del dosel G 3 G G Y Y X X Y Y C C 7 UL ES XavierII WH09 5 FLUSH MOUNT INSTALLATION If ush mount option is selected proceed to step 6 NORMAL DOWNROD INSTALLATION If installing downrod supplied with fan proceed to step 9 EXTENDED DOWNROD INSTALLATION If installing with longer downrod than supplied with fan proceed to page 8 step 11 NORMAL DOWNROD INSTALLATION EXTENDED DOWNROD INSTALLATION NORMAL OPCI N CON VARILLA VERTICAL M S LARGA
22. el cable azul s lo si conecta un juego de luces al ventilador Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador controlado con cadenilla de tiro OPCI N DE CABLEADO PARA CADENILLA DE TIRO OPCI N DE CABLEADO PARA CONTROL DE PARED no est incluido el interruptor de pared The canopy G has two mating slots and two mating holes Position both slots on canopy directly under and in line with two screws Y in the mounting bracket C Lift the canopy allowing the two screws to slide into the mating slots Rotate the canopy until both screws from the mounting bracket drop into the slot recesses Tighten screws securely Install two screws Y and star washers X into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket El dosel G tiene dos ranuras coincidentes y dos ori cios coincidentes Coloque ambas ranuras del dosel directamente abajo y en l nea con los dos tornillos Y del soporte de montaje C Eleve el dosel permitiendo que los dos tornillos se deslicen dentro de las ranuras Gire el dosel hasta que ambos tornillos del soporte de montaje caigandentro de las ranuras Apriete los tornillos asegur ndolos Instale los dos tornillos Y y las arandelas en estrella X en los ori cios coincidentes del dosel y aj stelos para asegurar el dosel al soporte de montaje Y C G X Y 10 UL ES XavierII WH09 Check the motor for plastic shi
23. ips y escalera de mano no incluidos 1 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards ANSI NFPA 70 1999 including fire rated construction 2 Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer 3 After making the wire connections gently push connections into outlet box with wire nuts pointing up The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 4 Before you begin installing the fan switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 5 Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams 6 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 7 Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade 8 To reduce the risk of fire electric shock or personal injury this fan must be mounted to an outlet bo
24. la cadenilla de la l mpara dos veces para reiniciarla Si la energ a de su ventilador se controla con un interruptor en la pared puede ser necesario apagar el interruptor y luego encenderlo Para ventiladores con Control de pared Presione el bot n en la pared una vez para apagar y una vez para encender para as reiniciar la l mpara Para ventiladores con Control remoto Si verifica el vataje y la luz no enciende presione el bot n para la luz en el control remoto dos veces para reiniciar la l mpara NoTA Si los procedimientos mencionados no reinician la l mpara desconecte la fuente principal de energ a ubicada en el panel o caja de interruptor y vu lvala a conectar NOTICE This Energy Policy Act 2005 compliant fan includes a device that limits the total wattage of its light fixture to 190 watts By installing a combination of light bulbs that exceeds 190 watts or if an electrical surge causes the wattage to exceed 190 watts the light fixture will either dim the lights to 190 watts or will automatically turn off To restore the light levels make sure the total wattage of the light bulbs does not exceed 190 watts and follow the applicable directions below for fans with Pull Chains Pull the light fixture s pull chain two times to reset the light fixture If the power to your fan is controlled by a toggle wall switch it may be necessary to turn the power off and back on at the wall switch for fans with Wall Controls
25. nos 15 87 kgs 9 ADVERTENCIA No doble los soportes para las paletas durante la instalaci n al motor al balancear o durante la limpieza No inserte objetos extra os entre las paletas mientras giran 10 Fije el soporte de montaje usando s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores 11 ADVERTENCIA Para reducir el riesgo de incendios o choques el ctricos no use este ventilador con un dispositivo de control de velocidad de estado s lido para ventilador o un control de velocidad variable 12 Si esta unidad se instalar sobre una ba era o una ducha debe estar identificada como adecuada para ese tipo de aplicaci n 13 NUNCA coloque un interruptor donde se pueda alcanzar desde una ba era o una ducha 14 Es posible que la operaci n de esta unidad afecte el flujo de aire de combusti n necesario para la operaci n segura de equipo que quema combustible Siga la directrices de seguridad del fabricante de equipo de calefacci n como las publicadas por la Asociaci n Nacional de Protecci n Contra Incendios National Fire Protection Association NFPA y la Sociedad Americana para Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades del c digo local 15 Antes de efectuar tareas de servicio
26. oscila Si la luz no funciona SoLuCI N SuGERIdA 1 Compruebe los fusibles o disyuntores principales y del circuito derivado 2 Compruebe el cableado del bloque de terminales como lo hizo en el paso No 14 de la instalaci n ADVERTENCIA Aseg rese de que la alimentaci n principal est apagada 3 Aseg rese de que el interruptor de tipo deslizante est firmemente situado en una de sus dos posiciones El ventilador no funcionar si el interruptor de tipo deslizante est situado en el medio 4 Si el ventilador no arranca p ngase en contacto con un electricista calificado No intente reparar conexiones el ctricas internas 1 Compruebe para asegurarse de que todos los tornillos del alojamiento del motor est n ajustados no los apriete demasiado 2 Compruebe para asegurarse de que los tornillos que fijan el soporte de la paleta del ventilador al motor est n apretados 3 Algunos motores de ventilador son sensibles a las se ales de los controles de velocidad variable de estado s lido para motores NO USE un control de velocidad variable de estado s lido 4 Permita el rodaje del ventilador durante un per odo de 24 horas La mayor a de los ruidos asociados con el ventilador nuevo desaparecer n despu s de este per odo 1 Verifique que todas las paletas est n firmemente atornilladas a los soportes de las paletas 2 Verifique que todos los soportes de las paletas est n firmemente aseguradas al motor 3 Aseg rese de que el
27. palmes con los conectores de cables mirando hacia arriba Se deben separar los cables el conductor de puesta a tierra y el conductor de puesta a tierra del equipo a un lado de la caja de embutir y el conductor que no tiene puesta a tierra del otro lado de la misma 4 Antes de comenzar a instalar el ventilador apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accidentalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio 5 Tenga cuidado Lea todas las instrucciones y la informaci n de seguridad antes de instalar su ventilador nuevo Revise los diagramas de montaje incluidos 6 Al cortar o perforar una pared o el cielo raso no da e el cableado el ctrico y otras instalaciones de servicios p blicos ocultos 7 Aseg rese de que el sitio para la instalaci n que escoja permita que el ventilador gire libremente sin obstrucciones Deje un espacio m nimo de 7 pies desde le piso hasta el borde posterior de la paleta 8 Para reducir el riesgo de incendios choques el ctricos o lesiones personales este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador Adem s debe utilizar los tornillos correspondientes incluidos con la caja de embutir El montaje debe soportar por lo me
28. pping stabilizer tabs and remove them if they are present Attach blade assembly to motor using motor screws provided Tighten screws securely Veri que si hay leng etas pl sticas de embalaje para sos tener al motor 1 y desc rtelas Fije el conjunto de las paletas al motor usando los tornillos para el motor incluidos Apriete los tornillos asegur ndolos 17 18 To install the canopy cover ring F peel the backing o the adhesive tape strips on the inside of the cover ring Slide the cover ring up the downrod and secure to the canopy by gently pressing the adhesive tape to the bottom of the canopy CAUTION Be careful and precise when attaching the canopy cover ring to the canopy Removal and or replacing of the cover ring may cause adhesive to mar or peel the painted nish from the surface of the canopy Para instalar el anillo de la cubierta del dosel F quite la parte posterior de las tiras de cinta adhesiva en el interior del anillo de la cubierta Deslice el anillo de la cubierta hacia la parte superior de la varilla vertical y aseg relo al dosel presionando suavemente la cinta adhesiva para que se pegue a la parte inferior del dosel ADVERTENCIA Cuando je el anillo de la cubierta del dosel al dosel h galo con mucho cuidado Al quitar y o volver a colocar el anillo de la cubierta el pegamento puede da ar o despegar la pintura de la super cie del dosel 16 Attach blade brackets I to blades B using the
29. sobre la varilla vertical para asegurar la esfera de la misma CONTIN E CON EL PASO 9 T D AA 11 9 Place downrod assembly E into canopy G canopy cover ring F and coupling cover H Feed motor wires though the downrod assembly E Coloque el conjunto de la varilla vertical E dentro del dosel G el anillo de la cubierta del dosel F y la cubierta del acoplamiento H Pase los cables del motor a trav s del conjunto de la varilla vertical E E G F H Insert downrod E into downrod coupling L Make sure to align hole in downrod with the hole in downrod coupling Install cross pin R through coupling and downrod Insert clamp pin Q into cross pin until it snaps into place Tighten set screws Z in coupling Slide coupling cover H over the downrod coupling PROCEED TO PAGE 9 STEP 13 Inserte la varilla vertical E en el acoplamiento L de la varilla vertical Aseg rese de que el ori cio de la varilla vertical y el del acoplamiento de la varilla vertical est n alineados Instale el pasador transversal R pas ndolo por el acoplamiento y la varilla vertical Inserte el pasador de retenci n Q en el pasador transversal hasta que escuche un chasquido que indique que est en la posici n adecuada Ajuste los tornillos de jaci n Z en el acoplamiento Deslice la cubierta del acoplamiento H sobre el acoplamiento de la varilla vertical PROCEDA A LA P G 9 PASO 13 Loosen downrod ball D
30. x marked suitable for fan support and use the mounting screws provided with the outlet box Mounting must support at least 35 lbs 9 WARNING Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet box marked Acceptable for Fan Support 11 WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control 12 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application 13 NEVER place a switch where it can be reached from a tub or shower 14 The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 15 Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel

Download Pdf Manuals

image

Related Search

Related Contents

  Kenmore Elite 23 cu. ft. Counter-Depth Side-by-Side Refrigerator w/ SmartSense - Stainless Steel Owner's Manual  非接触搬送洗浄装置 - 株式会社ダン科学  

Copyright © All rights reserved.
Failed to retrieve file