Home

Westinghouse 30-Inch Instruction Manual

image

Contents

1. Fije el conjunto de las paletas al motor usando los tornillos y las arandelas incluidos Apriete los arandelas de tela 2 y las tuercas 3 tornillos asegur ndolos Fije los soportes para paletas a las paletas con los tornillos 1 las 15 ETL ES Roundabout WH12 LIGHT FIXTURE INSTALLATION Install light bulbs Instale las bombillas de luz Locate the indentations on the neck of the glass 2 and align with the protrusions from the light kit 1 Lift the glass up allowing the protrusions to engage the indentations on the glass and twist the glass clockwise to lock into place Localice las marcas en el cuello de la pantalla de vidrio 2 y alin elas con las protuberancias del juego de luces 1 Levante la pantalla permitiendo que las protuberancias calcen en las marcas de la pantalla de vidrio y gire la pantalla en sentido horario para asegurarla en su sitio 16 ETL ES Roundabout WH12 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling Confirm chains are held by lightly pulling both chains in Sujetar las cadenas largas de tiro con las piezas finales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga en la pieza de uni n Aseg rese de que las cadenas est n bien sujetas tirando ligeramente de ambas cadenas en la pieza de uni n 17 ETL ES Roundabout WH12 OPERATION AND MAINTENANCE RIA A AAN Oper
2. su comodidad Clima frio posici n hacia arriba Atr s El ventilador gira en sentido de las agujas del reloj Una corriente de aire ascendente aleja el aire caliente del rea del ventilador de techo como lo indica la ilustraci n B Esto le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de seguridad cuando utilice el ventilador en esta posici n NOTA Apague el ventilador y espere a que se detenga antes de cambiar la direcci n de adelante atr s con el conmutador de tipo deslizante Mantenimiento 1 El movimiento natural del ventilador podr a hacer que se aflojen algunas conexiones Verifique las conexiones de soporte las piezas de fijaci n y los accesorios de las paletas dos veces al a o Cerci rese de que est n aseguradas 2 Limpie el ventilador peri dicamente para ayudar a mantener su apariencia nueva con el correr de los a os No use agua para limpiarlo ya que podr a da ar el motor o la madera o causar descarga el ctrica 3 Use s lo un cepillo blando o un trapo sin pelusa para no rayar el acabado El enchapado est sellado con una capa de laca para minimizar la decoloraci n o p rdida del brillo 4 No hay necesidad de aceitar el ventilador El motor tiene cojinetes de lubricaci n permanente 20 GU A PARA SOLUCIONAR PROBLEMAS PROBLEMA 1 Si el ventilador no arranca 2 Si el ventilador es ruidoso 3 Si
3. wattage to exceed 190 watts the light fixture 1 check to make sure all screws in motor housing are snug not over tightened will either dim the lights to 190 watts or will automatically turn off 2 check to make sure the screws which attach the fan blade holder to the motor are tight i 3 Some fan motors are sensitive to signals from Solid State variable speed controls To restore the light levels make sure the total wattage of the light bulbs DO NOT USe a Solid State variable speed control does not exceed 190 watts and follow the applicable directions below 4 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period For fans with Pull Chains Pull the light fixture s pull chain two times to reset the light All blades are weighed and grouped by weight Natural woods vary in density which could fixture If the power to your fan is controlled by a toggle wall switch it may cause the fan to wobble even though all blades are weight matched The following be necessary to turn the power off and back on at the wall switch am At ellas most ji odani TA fe wobble after each step Wall Controls Press the light button on the wall control check that all blades are screwe firmly into blade holders off and on once to reset the light fixture 2 check that all blade holders are tightened securely to motor 3 Make sure that canopy and mounting bracket are tightened securely to
4. y el cableado el ctrico los deben efectuar personas calificadas cumpliendo con todos los c digos y las normas aplicables ANSI NFPA 70 1999 incluyendo las de incendio Use esta unidad s lo de la manera en que el fabricante quiere que se haga Si tiene dudas llame al fabricante Despu s de hacer las conexiones empuje con cuidado las conexiones dentro de la caja de empalmes con los conectores de cables mirando hacia arriba Se deben separar los cables el conductor de puesta a tierra y el conductor de puesta a tierra del equipo a un lado de la caja de embutir y el conductor que no tiene puesta a tierra del otro lado de la misma Antes de comenzar a instalar el ventilador apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accidentalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio Tenga cuidado Lea todas las instrucciones y la informaci n de seguridad antes de instalar su ventilador nuevo Revise los diagramas de montaje incluidos Al cortar o perforar una pared o el cielo raso no da e el cableado el ctrico y otras instalaciones de servicios p blicos ocultos Aseg rese de que el sitio para la instalaci n que escoja permita que el ventilador gire libremente sin obstrucciones Deje un espacio m nimo de 7 pies desde le piso hasta el bord
5. D OPTION OPCI N CON VARILLA VERTICAL PARA CIELORRASO NORMAL Si instala la varilla vertical incluida con el ventilador proceda a la p gina 9 paso 6 EXTENDED DOWNROD OPTION Ifinstalling with longer downrod than supplied with fan proceed to page 10 step 8 OPCI N CON VARILLA VERTICAL M S LARGA Si instala una varilla vertical m s larga que la que se incluye con el Install mounting bracket to outlet box in ceiling using the screws and ventilador proceda a la p gina 10 paso 8 washers provided with the outlet box Instale el soporte de montaje a la caja de embutir del cielorraso con la torniller a suministrada con la caja de embutir ETL ES Roundabout WH12 NORMAL DOWNROD OPTION Place downrod assembly 1 into canopy 2 and coupling cover 3 Feed motor wires though the downrod assembly 1 Coloque el conjunto de la varilla vertical 1 dentro del dosel 2 y la cubierta del acoplamiento 3 Pase los cables del motor a trav s del conjunto de la varilla vertical 1 Insert downrod into downrod coupling Make sure to align hole in downrod with the hole in down rod coupling Install cross pin 1 through coupling and downrod Insert keeper pin 2 into cross pin until it snaps into place Tighten set screws 3 in coupling Slide coupling cover 4 over the downrod coupling PROCEEDTO PAGE 12 STEP 11 Inserte la varilla vertical en el acoplamiento de la varilla vertical Aseg rese de que el orificio de la varil
6. ETL ES Roundabout WH12 Roundabout Model GFP Series Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia Net Weight Peso Neto ETL ES Roundabout WH12 pom 10 11 12 13 14 ETL ES Roundabout WH12 ev me marra nom mmm mot vn SAFETY TIPS mn Tr pore ere rom OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR PERSONAL INJURY MOUNT TO OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer Ifyou have any questions contact the manufacturer After making the wire connections gently push connections into outlet box with wire nuts pointing up The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan switch power off at service panel and lock service disconnecting means
7. ION From Fan From House ji G ae rana ack hot BR connect gt t Black hot Blue hot mm Main ground EX connect gt A Green ground Attach blue wire only if attaching light kit with fan Follow diagram above to make wiring connections for fan pull chain control OPCION DE CABLEADO PARA CADENILLA DE TIRO Del Ventilador Blanco com n r eonectar e Blanco com n Negro vivo conectar gt Negro vivo Azul vivo mi Principal tierra ES conectar EA Verde de tierra De La Casa Conecte el cable azul s lo si conecta un juego de luces al ventilador Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador controlado con cadenilla de tiro 13 WALL CONTROL WIRING OPTION From Fan White common 3 connect gt White common Mall Control Black hot mmm connect gt t Fan Switch hot Blue hot com connect 000 Light Switch hot Main ground EER connect Green ground From House Atoch blue wire only if attaching light kit with fan Follow diagram above to make wiring connections for wall control operation Del Ventilador De La Casa Blanco com n conectar gt Blanco com n re Negro vivo mam conectar gt Interruptor del ventilador A Azul vivo mm conectar gt Interruptor de la luz vivo Principal tierra Ese conectar gt A Verde de tierra Conecte el ca
8. Nacional de Protecci n Contra Incendios National Fire Protection Association NFPA y la Sociedad Americana para Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades del c digo local 15 Antes de efectuar tareas de servicio o limpieza en la unidad apague la alimentaci n en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que se encienda accidentalmente Cuando no se puede bloquear el medio de desconexi n del servicio el ctrico fije de manera segura y un dispositivo de advertencia prominente como un r tulo al panel de servicio Antes de realizar la instalaci n es importante comprobar y volver a ajustar todos los tornillos seg n corresponda HERRAMIENTAS NECESARIAS Destornillador Phillips Pinzas de corte Pinzas Escalera mano ETL ES Roundabout WH12 FEATURES CARACTER STICAS DOWNROD VAULTED CEILING INSTALLATION INSTALLATION INSTALACI N CON INSTALACI N PARA VARILLA VERTICAL CIELORRASOS ABOVEDADOS May require a longer downrod For normal ceilings sold separately Para cielorrasos normales Podr a requerir una varilla vertical m s larga se vende por separado ETL ES Roundabout WH12 PREPARING FOR INSTALLATION Unpack and inspect fan carefully to be certain all contents are included Turn off power at fuse box to avoid
9. ation A Turn on the power and check operation of fan The pull chain controls the fan speeds as follows 1 pull high 2 pulls medium 3 pulls low 4 pulls off Speed settings for warm or cool weather depend on factors such as room size ceiling height number of fans and so on The slide switch controls direction forward or reverse U J Warm weather down position Forward Fan turns counterclockwise direction A downward air flow creates a cooling effect as shown in illustration A This allows you to set your air conditioner on a higher temperature setting without affecting your comfort Cool weather up position Reverse Fan turns clockwise direction An upward airflow moves warm air off the ceiling area as shown in illustration B This allows you to set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in Safety Tips when operating in this position a J NOTE Turn off and wait for fan to stop before changing the setting of the forward reverse slide switch Maintenance 1 Because of the fan s natural movement some connections may become loose Check the support connections brackets and blade attachments twice a year Make sure they are secure 2 Clean your fan periodically to help maintain its new appearance over the years Do not use water when cleaning This could damage the motor or the wood or possibly cause electrical shock 3 Use only a soft brush or lint free cloth t
10. b or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this units operation Follow the heating equipment manufacturers guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel All set screws must be checked and re tightened where necessary before installation TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder ETL ES Roundabout WH12 mvm o CONSEJOS DE SEGURIDAD np neee ne ssp s 6 HAGA LO SIGUIENTE LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO DESCARGA EL CTRICA O LESIONES PERSONALES MONTE EL VENTILADOR EN UNA CAJA DE EMBUTIR ROTULADA ADECUADA PARA VENTILADORES Y UTILICE LOS TORNILLOS DE MONTAJE INCLUIDOS CON LA CAJA DE EMBUTIR LA MAYOR A DE LAS CAJAS DE EMBUTIR UTILIZADAS NORMALMENTE PARA ARTEFACTOS DE ILUMINACI N NO SON ADECUADAS PARA VENTILADORES Y DEBER AN SER REEMPLAZADAS SI TIENE PREGUNTAS CONSULTE A UN ELECTRICISTA CERTIFICADO El trabajo de instalaci n
11. ble azul s lo si conecta un juego de luces al ventilador Siga las instrucciones del diagrama anterior para hacer las conexiones de cableado para el ventilador con control de pared ETL ES Roundabout WH12 SECURE TO CEILING The canopy has two mating slots 1 and two mating holes 2 Position both slots on canopy directly under and in line with two screws in the mounting bracket 3 Lift the canopy allowing the two screws to slide into the mating slots Rotate the canopy until both screws from the mounting bracket drop into the slot recesses Tighten screws securely Install two screws into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket El dosel tiene dos ranuras coincidentes 1 y dos orificios coincidentes 2 Coloque ambas ranuras del dosel directamente abajo y en l nea con los dos tornillos del soporte de montaje 3 Eleve el dosel permitiendo que los dos tomillos se deslicen dentro de las ranuras Gire el dosel hasta que ambos tornillos del soporte de montaje caigan dentro de las ranuras Apriete los tornillos asegur ndolos Instale los dos tornillos en los orificios coincidentes del dosel y aj stelos para asegurar el dosel al soporte de montaje 14 ETL ES Roundabout WH12 BLADE INSTALLATION Attach blade brackets to blades using the blade bracket screws 1 Attach blade assembly to motor using the screws and washers provided Tighten screws fabric washers 2 and nuts 3 securely
12. ceiling joist Remote Controls If you verify the wattage and the lights 4 If blade wobble is still noticeable interchanging two adjacent side by side blades can do not turn on press the light button on the remote redistribute the weight and possibly result in smoother operation control twice to reset the light fixture 1 check to see that the wire connections in the switch housing are connected NOTE If the procedures above do not reset the lights 2 check for faulty light bulbs turn off the main power source located at the breaker 3 If light kit will still not operate contact a qualified electrician for assistance 19 ETL ES Roundabout WH12 dotan Nas asia OPERACI N Y MANTENIMIENTO Operaci n Encienda el ventilador y verifique su funcionamiento La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera U J 1 jal n r pida 2 jalones mediana 3 jalones lenta 4 jalones apagado Las velocidades para clima c lido o fr o dependen de factores como el tama o de la habitaci n la altura del ventilador el n mero de ventiladores etc El conmutador de tipo deslizante controla la direcci n hacia adelante o hacia atr s Clima c lido posici n hacia abajo Adelante El ventilador gira en sentido contrahorario Una corriente de aire descendente crea un efecto refrescante como lo indica la ilustraci n A B Esto le permite ajustar el aire acondicionado a una temperatura m s alta sin que afecte
13. cencia de Westinghouse Electric Corporation es una marca registrada de Y Westinghouse Electric Corporation Hecho en China O 2012 Westinghouse Lighting Corporation
14. d a 190 vatios o se apagar Para restablecer el nivel de luminosidad aseg rese que el vataje total de las bombillas no sobrepase los 190 vatios y siga las indicaciones Aplicables a continuaci n Para ventiladores con Cadenilla de tiro Jale la cadenilla de la l mpara dos veces para reiniciarla Si la energ a de su ventilador se controla con un interruptor en la pared puede ser necesario apagar el interruptor y luego encenderlo Para ventiladores con Control de pared Presione el bot n en la pared una vez para apagar y Una Vez para encender para as reiniciar la l mpara Para ventiladores con Control remoto Si verifica el vataje y la luz no enciende presione el bot n para tla luz en el control remoto dos veces para reiniciar la l mpara NOTA Si los procedimientos mencionados no reinician la l mpara desconecte la fuente principal de energ a ubicada en el panel o caja de interruptor y vu lvala a conectar 22 ETL ES Roundabout WH12 23 ETL ES Roundabout WH12 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Lighting Corporation a Westinghouse Electric Corporation licensee 8 is a registered trademark of Westinghouse Electric Corporation Made in China 2012 Westinghouse Lighting Corporation ETL ES Roundabout WH12 Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Lighting Corporation titular de la li
15. de los ruidos asociados con el ventilador nuevo desaparecer n despu s de este per odo Todas las paletas se pesan y agrupan seg n el peso Las maderas naturales var an en densidad y podr an hacer que el ventilador oscile a n cuando todas las paletas est n agrupadas por peso Los siguientes procedimientos deber an eliminar la mayor a de los problemas de oscilaci n Verifique la oscilaci n despu s de cada paso 1 Verifique que todas las paletas est n firmemente atornilladas a los soportes de las paletas 2 Verifique que todos los soportes de las paletas est n firmemente aseguradas al motor 3 Aseg rese de que el dosel y el soporte de montaje est n firmemente asegurados a la viga del cielorraso 4 Sila oscilaci n de la paleta sigue siendo visible es posible que al intercambiar dos paletas adyacentes lado a lado se redistribuya el peso y el funcionamiento sea m s suave 1 Verifique que el conector molex del alojamiento del interruptor est conectado 2 Compruebe si hay l mparas defectuosas 3 Si el conjunto de luces no funciona p ngase en contacto con un electricista calificado 21 AVISO Este ventilador que cumple con las exigencias del energy Policy Act 2005 incluye un accesorio que limita el vataje total de su l mpara a 190 vatio Si usted instala una combinaci n de bombillas que sobrepasen los 190 vatios o si un sobrevoltaje hace que el voltaje sea superior a 190 vatios la l mpara regular la intensida
16. e posterior de la paleta Para reducir el riesgo de incendios choques el ctricos o lesiones personales este ventilador se debe montar sobre una caja de embutir que tenga una marca que indique que es adecuada para soportar un ventilador Adem s debe utilizar los tornillos correspondientes incluidos con la caja de embutir El montaje debe soportar por lo menos 15 87 kgs ADVERTENCIA No doble los soportes para las paletas durante la instalaci n al motor al balancear o durante la limpieza No inserte objetos extra os entre las paletas mientras giran Fije el soporte de montaje usando s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores ADVERTENCIA Para reducir el riesgo de incendios o choques el ctricos no use este ventilador con un dispositivo de control de velocidad de estado s lido para ventilador o un control de velocidad variable Si esta unidad se instalar sobre una ba era o una ducha debe estar identificada como adecuada para ese tipo de aplicaci n UNCA coloque un interruptor donde se pueda alcanzar desde una ba era o una ducha Es posible que la operaci n de esta unidad afecte el flujo de aire de combusti n necesario para la operaci n segura de equipo que quema combustible Siga la directrices de seguridad del fabricante de equipo de calefacci n como las publicadas por la Asociaci n
17. el ventilador oscila 4 Si la luz no funciona ETL ES Roundabout WH12 Si tiene dificultades para hacer funcionar su nuevo ventilador podria ser a causa del armado instalaci n o cableado incorrectos En algunos casos estos errores de instalaci n podr an ser confundidos con defectos Si experimenta alguna falla consulte esta gu a para solucionar problemas Si no puede solucionar el problema consulte a un electricista autorizado y no intente reparar conexiones el ctricas SOLUCI N SUGERIDA 1 Compruebe los fusibles o disyuntores principales y del circuito derivado 2 Compruebe el cableado del bloque de terminales como lo hizo en el paso No 13 14 de la instalaci n ADVERTENCIA Aseg rese de que la alimentaci n principal est apagada 3 Aseg rese de que el interruptor de marcha adelante atr s est firmemente en su posici n El ventilador no funcionar si el interruptor est en el medio 4 Si el ventilador no arranca p ngase en contacto con un electricista calificado No intente reparar conexiones el ctricas internas 1 Compruebe para asegurarse de que todos los tornillos del alojamiento del motor est n ajustados no los apriete demasiado 2 Compruebe para asegurarse de que los tornillos que fijan el soporte de la paleta del ventilador al motor est n apretados 3 NO USE un control de velocidad variable de estado s lido 4 Permita el rodaje del ventilador durante un per odo de 24 horas La mayor a
18. la vertical y el del acoplamiento de la varilla vertical est n alineados Instale el pasador trans versal 1 pas ndolo por el acoplamiento y la varilla vertical Inserte el pasador de retenci n 2 en el pasador transversal hasta que escuche un chasquido que indique que est en la posici n adecuada Ajuste los tornillos de fijaci n 3 en el acoplamiento Deslice la cubierta del acoplamiento 4 sobre el acoplamiento de la varilla vertical PROCEDA A LA P G 12 PASO 11 ETL ES Roundabout WH12 EXTENDED DOWNROD OPTION Loosen downrod ball 1 from downrod 2 by removing set screw 3 Slide downrod ball 1 offof downrod and remove pin 2 Afloje la esfera de la varilla vertical 1 de la varilla vertical 2 quitando el Deslice la esfera de la varilla vertical 1 hasta separarla de la varilla vertical y tomillo 3 quite el pasador 2 10 ETL ES Roundabout WH12 EXTENDED DOWNROD OPTION Re install pin into extended downrod and slide downrod ball up to the top of the downrod Re install set screw to secure ball to downrod Note Some extended downrods have a pre drilled set screw hole If a pre drilled hole is present in the extended downrod tighten the set screw into the pre drilled hole in the extended downrod If no pre drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball PROCEEDTO PAGE 9 STEP 6 Vuelva a instalar el pasador en la varilla vertical m s larga
19. o avoid scratching the finish The plating is sealed with a lacquer coating to minimize discoloration or tarnishing 4 There is no need to oil your fan The motor has permanently lubricated bearings 18 ETL ES Roundabout WH12 If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these TROUBLESHOOTING GUIDE installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be TROUBLE 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work remedied please consult with your authorized electrician and do not attempt any electrical repairs yourself SUGGESTED REMEDY 1 check main and branch circuit fuses or circuit breakers 2 check wire connections as performed in step 13 14 of installation CAUTION Make sure main power is turned off NOTICE 3 Make sure forward reverse switch is firmly in up or down position This Energy Policy Act 2005 compliant fan includes a device Fan will not operate when switch is in the middle that limits the total wattage of its light fixture to 190 watts 4 If the fan still will not start contact a qualified electrician Do not attempt to troubleshoot internal electrical connections yourself By installing a combination of light bulbs that exceeds 190 watts or if an electrical surge causes the
20. possible electrical shock Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimentaci n en la caja de fusibles para evitar la posibilidad de descarga el ctrica Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Use una caja de embutir de metal adecuada para soportar un ventilador debe soportar 35 libras Antes de fijar el ventilador a la caja de embutir aseg rese de que la misma est fijada de manera segura en por lo menos dos puntos a un miembro estructural del cielo raso una caja suelta har a que el ventilador oscile ETL ES Roundabout WH12 MOUNTING BRACKET INSTALLATION Remove the screws from the two mating holes 1 on the canopy Loosen do not remove the screws in the mating slots 2 on the canopy Rotate the mounting bracket and remove from the canopy Quite los tornillos de los dos orificios coincidentes 1 del dosel Afloje no quite los tornillos de las ranuras coincidentes 2 del dosel Gire el soporte de montaje y sep relo del dosel ETL ES Roundabout WH12 me MOUNTING BRACKET INSTALLATION MOUNTING OPTIONS INSTALACION CON SOPORTE OPCIONES DE MONTAJE DE MONTAJE 5 Choose a MOUNTING OPTION Elija una OPCI N DE MONTAJE NORMAL DOWNRO
21. to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent waming device such as a tag to the service panel Be cautious Read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury this fan must be mounted to an outlet box marked suitable for fan support and use the mounting screws provided with the outlet box Mounting must support at least 35 Ibs WARNING Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet box marked Acceptable for Fan Support WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tu
22. y deslice la esfera de la varilla hasta el extremo superior de la misma Vuelva a insertar el tornillo de fijaci n para asegurar la esfera a la varilla vertical Nota Algunas varillas verticales m s largas tienen un agujero previamente perforado para el tornillo Si la varilla vertical m s larga tiene un agujero previamente perforado ajuste el tomillo en el agujero previamente perforado de la varilla vertical m s larga Si la varilla vertical m s larga no tiene un agujero previamente perforado ajuste el tornillo sobre la varilla vertical para asegurar la esfera de la misma PROCEDA A LA P G 9 PASO 6 11 ETL ES Roundabout WH12 MOUNTING Carefully lift fan assembly onto mounting bracket Rotate fan until notch on downrod ball 1 engages the ridge on the mounting bracket 2 This will allow for hands free wiring With bracket holding fan assembly make electrical connections using the following Levante con cuidado el conjunto del ventilador hasta el soporte de montaje Gire step for wiring instructions el ventilador hasta que la muesca de la bola de la varilla vertical 1 calce sobre la saliente del soporte de montaje 2 De este modo tendr las dos manos libres para hacer el cableado Con la pieza de montaje sujetando el conjunto del ventilador haga las conexiones el ctricas de acuerdo a las siguientes instrucciones de cableado 12 ETL ES Roundabout WH12 WIRING OPTIONS OPCI N DE CABLEADO PULL CHAIN WIRING OPT

Download Pdf Manuals